The need for phase-encoding flow compensation in high-resolution intracranial magnetic resonance angiography.

PURPOSE: To demonstrate that the time delay between phase and frequency encoding and the presence of pulsatile blood flow in high-resolution time-of-flight (TOF) imaging of the intracranial arteries (especially near the circle of Willis) can distort the appearance of blood vessels and result in a cross-hatch-appearing artifact in surrounding tissue. MATERIALS AND METHODS: Two techniques to reduce the artifact, tri-directional flow compensation (3DFC) and elliptical-centric (EC) phase-encoding order, are investigated in five volunteer studies. RESULTS: 3DFC eliminates the pulsation-related artifacts and the vessel distortion. A residual amplitude variation artifact is observed. EC phase encoding nearly eliminates the pulsatile motion-related artifact, but it does not eliminate vessel distortion. CONCLUSION: The combination of 3DFC and EC phase encoding appears to provide the greatest artifact reduction in the five volunteer studies performed.

Adult↗

Strategies to improve contrast in turboFLASH imaging: reordered phase encoding and k-space segmentation.

TurboFLASH (fast low-angle shot) sequences enable the acquisition of an image in a fraction of a second. However, unique to T1-weighted ultrafast imaging, the magnetization variation during image acquisition can produce artifacts along the phase-encoding direction. In this study, the signal behavior and nature of these artifacts were analyzed with various acquisition schemes to improve image contrast. The magnetization variation during image acquisition and its filtering effect on the image were simulated for three different approaches to T1-weighted turboFLASH imaging: standard turboFLASH with (a) monotonically ascending phase-encoding steps, (b) reordered phase encoding, and (c) k-space segmentation. Each of the modified data acquisition schemes has advantages. However, for subsecond imaging, reordered phase encoding produced improved image contrast over that of standard turboFLASH, and segmented k-space imaging gave superior tissue contrast compared with that of both standard and reordered turboFLASH, with imaging time that permits breath-hold studies.

Computer Simulation↗

Ghost phase cancellation with phase-encoding gradient modulation.

Motion artifacts are a dominant cause of magnetic resonance image quality degradation. Periodic or nearly periodic motion results in image replicates of the moving structures in spin-warp Fourier imaging. The replicates, or ghosts, propagate in the image in the phase-encoding, or y, direction. These ghosted images can be considered to consist of the time-averaged spin density I0 and a ghost mask g. A set of j ghosted images Ij may be acquired in which the ghost mask is intentionally phase shifted by varying amounts relative to I0 with interleaved acquisitions that have shifted phase-encoding orders or by acquiring multiple images during a single readout period in the presence of an oscillating phase-encoding gradient. The resulting complex images Ij have the same time-averaged spin density I0 but have ghost contributions gj that, on a pixel-by-pixel basis, trace part of a circle around I0. The source images Ij can then be used to estimate I0. Simulations and experiments with the phase-encoding gradient modulation method show good general ghost suppression for a variety of quasi-periodic motion sources including both respiratory-type artifacts and flow artifacts. The primary limitation of the method is the need for rapid gradient switching.

Artifacts↗

A simulation study to assess SVD encoding for interventional MRI: effect of object rotation and needle insertion.

Singular value decomposition (SVD) encoding offers great promise to provide high spatial and temporal resolution required for interventional MRI (I-MRI) (1). This study investigates its efficacy when (a) objects are rotated and (b) a small device (ie, a needle) is moved within anatomic structures. It was found that SVD-encoded MRI is biased toward the reference from which encoding vectors are derived, thus providing a potential limitation under conditions in which the object has undergone significant global change. Reference images with partial device insertion may be needed to accurately resolve the device or track the object motion. Theoretically, the differences between the reference and the object being imaged suggest that SVD encoding is suboptimal (in a minimum mean squared error sense). Other encoding/reconstruction algorithms may come closer to achieving the desired advantages in spatial and temporal fidelity.

Biopsy, Needle↗

Can a single-shot black-blood T2-weighted spin-echo echo-planar imaging sequence with sensitivity encoding replace the respiratory-triggered turbo spin-echo sequence for the liver? An optimization and feasibility study.

PURPOSE: To optimize and assess the feasibility of a single-shot black-blood T2-weighted spin-echo echo-planar imaging (SSBB-EPI) sequence for MRI of the liver using sensitivity encoding (SENSE), and compare the results with those obtained with a T2-weighted turbo spin-echo (TSE) sequence. MATERIALS AND METHODS: Six volunteers and 16 patients were scanned at 1.5T (Philips Intera). In the volunteer study, we optimized the SSBB-EPI sequence by interactively changing the parameters (i.e., the resolution, echo time (TE), diffusion weighting with low b-values, and polarity of the phase-encoding gradient) with regard to distortion, suppression of the blood signal, and sensitivity to motion. The influence of each change was assessed. The optimized SSBB-EPI sequence was applied in patients (N = 16). A number of items, including the overall image quality (on a scale of 1-5), were used for graded evaluation. In addition, the signal-to-noise ratio (SNR) of the liver was calculated. Statistical analysis was carried out with the use of Wilcoxon's signed rank test for comparison of the SSBB-EPI and TSE sequences, with P = 0.05 considered the limit for significance. RESULTS: The SSBB-EPI sequence was improved by the following steps: 1) less frequency points than phase-encoding steps, 2) a b-factor of 20, and 3) a reversed polarity of the phase-encoding gradient. In patients, the mean overall image quality score for the optimized SSBB-EPI (3.5 (range: 1-4)) and TSE (3.6 (range: 3-4)), and the SNR of the liver on SSBB-EPI (mean +/- SD = 7.6 +/- 4.0) and TSE (8.9 +/- 4.6) were not significantly different (P > .05). CONCLUSION: Optimized SSBB-EPI with SENSE proved to be feasible in patients, and the overall image quality and SNR of the liver were comparable to those achieved with the standard respiratory-triggered T2-weighted TSE sequence.

Adenoma, Liver Cell↗

Reactivation of chronic type B hepatitis: the effect on expression of serum HBV-DNA and pre-S encoded proteins.

Hepatitis B markers were studied in seven patients with reactivated liver disease. Reactivation of chronic type B hepatitis, as indicated by the reappearance of hepatitis B e antigen (HBeAg) in the serum, was characterised by the appearance of hepatitis B virus-DNA (HBV-DNA) in the serum. The expression of pre-S 1 encoded protein remained unchanged in five of seven patients, and poly-HSA as a marker for pre-S 2 encoded protein remained detectable in six of seven patients before and after reactivation of chronic hepatitis. The level of serum HBV-DNA correlated well with the level of liver enzymes, which rose from normal to various levels after reactivation of the liver disease. The data suggest that inflammatory activity of the liver disease is not related to the expression of pre-S encoded protein but to viral replication. Possibly pre-C and C-gene encoded antigens, which are produced together with viral nucleic acid and expressed on the surface of HBV-infected liver cells, play the key role in liver damage believed to be mediated by cytotoxic T cells.

Adolescent↗

Homogeneous preparation encoding (HoPE) in multislice imaging.

Fast magnetization preparation techniques acquire a series of echoes after a single magnetization preparation. If these echoes are acquired from different slices using a multislice technique the change in the preparation state of the echoes due to relaxation effects leads to different contrast modification for each slice. Encoding different preparation states along the phase-encoding direction of each slice instead of acquiring each slice in a different preparation state is introduced as a general concept to obtain images of identical contrast and point-spread function. This can be realized either by cycling the slice excitation order several times over the total number of repetitions or by moving the point of time at which the preparation is applied within each repetition. One possible application of this method is chemical shift selective fat saturation imaging. A homogeneous fat suppression across a multislice volume could be achieved using a FLASH sequence at a repetition time of TR = 145 ms, including a single fat saturation preparation. Conventional fat saturated spin-echo imaging at any TR can be accelerated significantly by reducing the number of applied preparations per repetition. A further application of the homogeneous preparation encoding (HoPE) method is described that encodes the spatial self-saturation of the multislice excitation order homogeneously in all slices. Only a reduced number of slices of the total volume are excited in each repetition and the slice excitation order is continuously moved along the imaging volume. This method is applied for time of flight (TOF) imaging. Using a TONE-like series of flip angles for the slice excitations of each repetition homogeneous TOF images can be obtained on the basis of a multislice acquisition.

Abdomen↗

Sensitivity-encoded spectroscopic imaging.

Sensitivity encoding (SENSE) offers a new, highly effective approach to reducing the acquisition time in spectroscopic imaging (SI). In contrast to conventional fast SI techniques, which accelerate k-space sampling, this method permits reducing the number of phase encoding steps in each phase encoding dimension of conventional SI. Using a coil array for data acquisition, the missing encoding information is recovered exploiting knowledge of the distinct spatial sensitivities of the individual coil elements. In this work, SENSE is applied to 2D spectroscopic imaging. Fourfold reduction of scan time is achieved at preserved spectral and spatial resolution, maintaining a reasonable SNR. The basic properties of the proposed method are demonstrated by phantom experiments. The in vivo feasibility of SENSE-SI is verified by metabolic imaging of N-acetylaspartate, creatine, and choline in the human brain. These results are compared to conventional SI, with special attention to the spatial response and the SNR.

Brain↗

Effect of phase-encoding direction upon magnetic resonance image quality of the heart.

In order to optimize overall cardiac image quality on MR images experienced observers were asked to rank and rate MR images of the heart. The effect of phase-encoding direction and use of cardiac triggering with and without respiratory gating was examined in three orthogonal imaging planes. Results indicate that use of both respiratory and cardiac gating yields the best images. Adequate images of the heart can be obtained without respiratory gating. The quality of images of the heart can be optimized by proper selection of the direction of the phase-encoding gradient. These are improved by using horizontal phase encoding in the sagittal plane and vertical phase encoding in transverse and coronal planes.

Heart↗

Hydrogen ultrathin phase-encoded spectroscopy (HUPSPEC).

This paper describes a new clinical spectroscopy pulse program, hydrogen ultrathin phase-encoded spectroscopy. This sequence combines high spatial resolution with magnitude hydrogen spectroscopy. A linear volume is spatially frequency encoded with a conventional readout gradient and phase encoded spectrally by incrementing the timing of acquisition. The pulse sequence is implemented on a whole-body MRI scanner and supports several standard scanner options, including autoprescanning, offset of the center of field of view in the frequency-encoding direction, and oblique imaging. Some preliminary experimental experience is reported, demonstrating the possibility of observing the spectral linewidths of fat and water in marrow, and of observing the spectral linewidths of fat and water in marrow, and of observing multiline spectra. Combination of the technique with water suppression methods in a sequence called WASHUP is also discussed.

Adult↗

Reduced phase encoding in spectroscopic imaging.

The effect of different spatial-encoding (k-space) sampling distributions are evaluated for magnetic resonance spectroscopic imaging (MRSI) using Fourier reconstruction. Previously, most MRSI studies have used square or cubic k-space functions, symmetrically distributed. These studies examine the conventional k-space distribution with spherical distribution, and 1/2 k-space acquisition, using computer simulation studies of the MRSI acquisition for three spatial dimensions and experimental results. Results compare the spatial response function, Gibbs ringing effects, and signal contamination for different spatial-encoding distribution functions. Results indicate that spherical encoding, in comparison with cubic encoding, results in a modest improvement of the response function with approximately equivalent spatial resolution for the same acquisition time. For spin-echo acquired data, reduced acquisition times can readily be obtained using 1/2 k-space methods, with a concomitant reduction in signal to noise ratio.

Adenosine Triphosphate↗

High speed 1H spectroscopic imaging in human brain by echo planar spatial-spectral encoding.

We introduce a fast and robust spatial-spectral encoding method, which enables acquisition of high resolution short echo time (13 ms) proton spectroscopic images from human brain with acquisition times as short as 64 s when using surface coils. The encoding scheme, which was implemented on a clinical 1.5 Tesla whole body scanner, is a modification of an echo-planar spectroscopic imaging method originally proposed by Mansfield Magn. Reson. Med. 1, 370-386 (1984), and utilizes a series of read-out gradients to simultaneously encode spatial and spectral information. Superficial lipid signals are suppressed by a novel double outer volume suppression along the contours of the brain. The spectral resolution and the signal-to-noise per unit time and unit volume from resonances such as N-acetyl aspartate, choline, creatine, and inositol are comparable with those obtained with conventional methods. The short encoding time of this technique enhances the flexibility of in vivo spectroscopic imaging by reducing motion artifacts and allowing acquisition of multiple data sets with different parameter settings.

Artifacts↗

Echo-time reduction for submillimeter resolution imaging with a 3D phase encode time reduced acquisition method.

To achieve optimal image quality and highest spatial resolution for inner ear imaging with a 3D gradient echo sequence, it is necessary to minimize susceptibility dephasing effects by using very short TE. Fractional RF pulses and echoes can yield short TE for moderate spatial resolution; however, for voxel size of less than 1 mm, TE is limited by the phase encode gradients. We present a method to obtain very short effective TE by using short triangular shaped phase encode gradients to sample the central portions of k-space and progressively longer trapezoidal gradients for the outer portions of k-space. A 3D pulse sequence employing the modified phase encoding scheme for both in-plane and slice phase encoding directions was implemented and tested on phantoms and in vivo. The effective TE equals the minimal TE used for the central k-space portions. Submillimeter resolution (0.35 x 0.35 x 0.7 mm3) images of the inner ear were obtained with effective TE of 3.2 ms and were compared with standard 3D images with TE of 8 ms. With this pronounced TE reduction, the susceptibility artifacts at air/fluid interfaces are significantly reduced.

Adult↗

Implementation of a fast gradient-echo SVD encoding technique for dynamic imaging.

In the paper, the results of a fast gradient-echo implementation of the singular value decomposition (SVD) encoding technique for dynamic imaging are presented. The method used is an adaptation with several critical modifications of a keyholetype approach previously proposed but not implemented. The method was tested by imaging the events following injection of a contrast agent into a phantom, producing a series of dynamic image updates. It is demonstrated that, for this type of application, the SVD encoding technique adequately follows dynamic changes with even a small number of encodes. The result is compared qualitatively to that obtained by standard Fourier-based keyhole imaging and is shown to provide improved spatial resolution of dynamic events when updating with the same number of encodes.

Algorithms↗

Velocity encoding using ghost artifacts.

Motion artifacts represent a significant limitation of MRI, and an ideal solution to that problem has proved elusive. However, in this paper, motion artifacts are not considered as the usual enemy and are not suppressed; on the contrary, they are deliberately created to encode flow information. In MRI, velocity is encoded readily into the phase of a pixel. However, if the pixel contains overlapping signals, the phase of one of these signals now has consequences on both the magnitude and phase of the resulting pixel. It is shown here that an overlap of information may be used to encode velocity both in the phase and in the magnitude of an image, making the velocity-encoding process faster. The overlap of information is obtained by superposing ghosting artifacts of different orders and information is retrieved about complex intensity and velocity in two dimensions using the equivalent of two images instead of the usual three images. The price to pay to do so is some loss of simplicity in the equations involved, an increase in reconstruction computing time requirements, and a factor of 4 decrease in signal-to-noise ratio in the velocity measurements.

Artifacts↗

Analysis of localized quadratic encoding and reconstruction.

Localized quadratic (LQ) encoding is a method of collecting multislice MRI data sets with greatly overlapping excited slices in such a way that the slice overlap can be deconvolved. This results in reconstructed data with resolution equal to the center-to-center slice spacing, regardless of the amount of excited slice overlap. LQ encoding is analyzed using the modulation transfer function of the encoding and reconstruction process. This allows analysis of many aspects of the technique in a well established theoretical framework. Many different characteristics of the method are explored, including excited slice profiles, required RF magnitudes and specific absorption rate, signal to noise ratio, signal dynamic range, reconstruction artifacts, sensitivity to motion, saturation and inflow effects, modulation transfer function shifting, and off-resonance artifacts. It is suggested that this technique is best suited for applications currently using multiple thin-slab three-dimensional encoding.

Absorption↗

A comparison of phase encoding ordering schemes in T2-weighted GRASE imaging.

Gradient and spin echo (GRASE) imaging is an echo train imaging sequence that combines gradient and RF refocusing. This combination introduces phase modulations into the echo train. If the phase encoding order is linear with echo time, these modulations cause severe ghosting artifacts. Changing the order of phase encoding can greatly reduce these artifacts. Several phase encoding orders for T2-weighted sequences are compared in this paper, linear, partially randomized, standard GRASE ordering, and k-banded (kb) GRASE ordering. Different possible implementations of GRASE and kbGRASE are also considered. Computer simulation is used to compare resolution and artifact levels. Phantom and volunteer images are presented. The linear order is most sensitive to ghosting artifacts associated with chemical shift, susceptibility differences and static field inhomogeneities. The standard GRASE order is least sensitive to these but most vulnerable to artifacts associated with short T2 signals, kb-GRASE is a good intermediate between linear and standard GRASE and generally shows the lowest artifact levels. The partially randomized order gives the most diffuse artifacts. Computer simulations show that spatial resolution and contrast with all phase encoding orders are similar.

Artifacts↗

Acceleration mapping by Fourier acceleration-encoding: in vitro study and initial results in the great thoracic vessels.

Acceleration mapping can be conducted by replacing the bipolar gradient pulse of a velocity mapping sequence by a tripolar pulse. However, since the acceleration encoding pulse is longer, the image quality is altered by the requirement of a long echo time. Since Fourier encoding velocity imaging has been shown to be robust, this velocity mapping method was transformed into an acceleration mapping method. Four steps of the tripolar acceleration encoding gradient pulse were applied successively; acceleration was then obtained by Fourier transform after zero-filling. The accuracy of the method was assessed with a phantom giving a pulsatile flow. Acceleration maps of the ascending aorta and pulmonary artery were obtained in 10 healthy volunteers. The acceleration values measured were in the range of known physiologic values. The feasibility of Fourier encoding acceleration imaging was also demonstrated in four patients.

Adolescent↗