Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CHROMATOGRAPHY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60Linked to original sources

Nanoliquid chromatography-mass spectrometry of oligosaccharides employing graphitized carbon chromatography on microchip with a high-accuracy mass analyzer.

The nanoLC separations of oligosaccharides using microchip-based columns are described. Mixtures of alditols from mucins and human milk are separated on graphitized carbon. The nanoLC-MS device showed high mass accuracy for the oligosaccharides ranging between 1 and 6 ppm on routine analyses. The high mass accuracy readily allowed identification of oligosaccharide peaks and the determination of their compositions. High retention time reproducibility was exhibited by the microchip LC. Little variation was observed for standard sample either alone or in a complex heterogeneous mixture. The nanoLC-MS exhibits excellent capabilities in profiling mixtures of oligosaccharides.

Carbon↗

Purification of beta-glucocerebrosidase by preparative-scale high-performance liquid chromatography: the use of ethylene glycol-containing buffers for chromatography of hydrophobic glycoprotein enzymes.

beta-Glucocerebrosidase, partially purified by the method of F. S. Furbish et al. (1977, Proc. Natl. Acad. Sci. USA 74, 3560-3563), was shown by sodium dodecyl sulfate-polyacrylamide gel electrophoresis to contain, in addition to the desired enzyme, variable amounts of a very hydrophobic contaminant (apparent Mr 45,000). Purification of the enzyme was accomplished by gel-permeation HPLC on a TSK 3000 SW column (0.7 X 60 cm). Adsorptive losses of protein on the column were minimized by using buffers containing up to 50% ethylene glycol. We have examined the effects of varying the ethylene glycol concentration on the elution times and recoveries of the two major proteins in this preparation. The high reproducibility of the individual chromatograms permitted the use of an automatic sampler and fraction collector to perform multiple, continuous runs for the purification of milligram quantities of enzyme. Multiple runs of a preparative-scale column, TSK G3000 SWG (2.15 X 60 cm), permitted gram-scale purification of beta-glucocerebrosidase without loss in efficiency of separation. Recovery of enzyme activity is greater than 94% with less than 1% contamination by other proteins. Reaction of enzyme prepared in this fashion with rabbit polyclonal antiserum or mouse monoclonal anti-beta-glucocerebrosidase shows the enzyme to be pure and not immunologically related to the 45,000 Mr contaminant. The specific activity of enzyme prepared by this means is 1.6 X 10(6) nmol/h/mg protein. Inclusion of ethylene glycol in buffers was shown to overcome hydrophobic protein interactions with TSK 3000 SW column matrices for both the soluble human lysosomal enzyme alpha-galactosidase A and the plant toxin ricin.

Animals↗

Enzyme-based high-performance liquid chromatography supports as probes of enzyme activity and inhibition: the immobilization of trypsin and alpha-chymotrypsin on an immobilized artificial membrane high-performance liquid chromatography support.

Immobilized artificial membrane (IAM) HPLC supports have been used to immobilize the enzymes alpha-chymotrypsin and trypsin. The enzymes were trapped in hydrophobic cavities on the support and were not covalently attached to the IAM surface. The resulting IAM-enzyme supports retained the hydrolytic activity of the immobilized enzymes: the IAM-trypsin support catalyzed the hydrolysis of N alpha-benzoyl-DL-arginine-p-nitroanilide (BAPNA), and the IAM-alpha-chymotrypsin support (IAM-ACHT) catalyzed the hydrolysis of a number of substrates, including tryptophan methyl ester. The activities of both supports were decreased by known enzyme inhibitors and the activity of the IAM-ACHT was affected by changes in pH and temperature. When a substrate was chromatographed on an IAM-ACHT HPLC, the hydrolytic activity of the immobilized enzyme could be determined from the resulting substrate/product ratios. These data were obtained either directly from the IAM-ACHT chromatogram or from the chromatogram produced by a coupled column system. The results of this study indicate that IAM-immobilized alpha-chymotrypsin and trypsin can be used as chromatographic probes for the qualitative determination of enzyme/substrate and enzyme/inhibitor interactions.

Benzoylarginine Nitroanilide↗

High-performance liquid chromatography of amino acids, peptides and proteins. CXV. Thermodynamic behaviour of peptides in reversed-phase chromatography.

The thermodynamic behaviour of three peptides, bombesin, beta-endorphin and glucagon, was studied under reversed-phase high-performance liquid chromatographic conditions. Experimental data related to the interactive surface contact area (S values) and solute affinity (log k0) were derived over a range of temperatures between 5 and 85 degrees C. These experimental conditions allowed changes in the secondary structure of the solute to be monitored. The influence of the nature of the stationary phase ligand on the relative conformational stability of the three peptides was analysed by acquiring data with n-octadecyl silica (C18) and n-butyl silica (C4) sorbents. Values for the relative changes in entropy and enthalpy associated with the interactive process were also determined. The results provide further insight into the factors involved with the stabilization of secondary structure and the mechanism of the interaction of peptides with hydrophobic surfaces.

Amino Acid Sequence↗

High-performance liquid chromatography of amino acids, peptides and proteins. CXXXIII. Peak tracking of peptides in reversed-phase high-performance liquid chromatography.

A peak tracking algorithm for peptide analysis has been developed based on a normalised spectral overlay method which directly compares the UV spectra of any two chromatographic peaks. Additionally, the algorithm compares the spectrum of each peak in the first chromatogram with the spectra of every peak in the second chromatogram to determine the best cross-match. The sensitivity of the technique was further enhanced by incorporation of the primary and secondary derivative spectra for cross-match normalisation. The utility of the software was demonstrated by its application to the analysis of tryptic digests of porcine growth hormone. Peptide solutes could be identified and tracked in chromatograms generated with various column types, gradient times, mobile phase types and temperatures. These results therefore constitute the initial stages of development of a more robust approach to the optimisation of the resolution, detection and characterisation of peptides and proteins separated by HPLC techniques.

Algorithms↗

Application of gas chromatography-mass spectrometry and gas chromatography-tandem mass spectrometry to the analysis of chemical warfare samples, found to contain residues of the nerve agent sarin, sulphur mustard and their degradation products.

Samples of clothing, grave debris, soil and munition fragments, collected from the Kurdish village of Birjinni, were analysed by GC-MS with selected ion monitoring (SIM) for traces of chemical warfare agents and their degradation products. Positive analyses were confirmed, where possible, by full scan mass spectra, or at low concentrations by additional GC-MS-SIM analysis using chemical ionisation, by higher resolution GC-MS-SIM, and by GC-tandem mass spectrometry using multiple reaction monitoring. Sulphur mustard and/or thiodiglycol were detected in six soil samples; isopropyl methylphosphonic acid and methylphosphonic acid, the hydrolysis products of the nerve agent sarin, were detected in six different soil samples. Trace amounts of intact sarin were detected on a painted metal fragment associated with one of these soil samples. The results demonstrate the application of different GC-MS and GC-MS-MS techniques to the unequivocal identification of chemical warfare agent residues in the environment at concentrations ranging from low ppb to ppm (w/w). They also provide the first documented unequivocal identification of nerve agent residues in environmental samples collected after a chemical attack.

Chemical Warfare Agents↗