Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Torque”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

Force and torque production in static multifinger prehension: biomechanics and control. I. Biomechanics.

We studied the coordinated action of fingers during static tasks involving exertion of force and torque on a handheld object. Subjects were asked to keep a handle with an attachment that allowed for independent change of the suspended load (0.5-2.0 kg) and external torque (0.375-1.5 N m) in a vertical position while applying minimal effort. Normal and shear forces were measured from the thumb; normal forces only were measured from the four fingers. EXPERIMENTAL RESULTS: (1) the thumb shear force increased during supination efforts and decreased during pronation efforts; (2) the total moment of the normal finger forces only counterbalanced approximately 50% of the external torque, hence shear forces accounted for approximately one-half of the total torque exerted on the object; (3) the total normal force increased with external torque, and the total force magnitude did not depend on the torque direction; (4) the forces of the 'peripheral' (index and little) fingers depended mainly on the torque while the forces exerted by the 'central' (middle and ring) fingers depended both on the load and torque; (5) there was a monotonic relationship between the mechanical advantage of a finger (i.e., its moment arm during torque production) and the force produced by that finger; and (6) antagonist finger moments acting opposite to the intended direction of the total moment were always observed - at low torques the antagonist moments were as high as 40-60% of the agonist moments. MODELING: A three-zone model of coordinated finger action is suggested. In the first zone of load/torque combinations, activation of antagonist fingers (i.e., fingers that generate antagonist moments) is necessary to prevent slipping. In the second zone, the activity of agonist fingers is sufficient for preventing slips. In the third zone, the performer has freedom to choose between either activating the antagonist fingers or redistributing activities amongst the agonist fingers. The findings of this study provide the foundation for neural network and optimization modeling described in the companion paper [Zatsiorsky et al. (2002) Biol Cybern DOI 10.1007/s00422-002-0320-7].

Adult↗

Insertional torque of the lumbar pedicle screw during surgery.

The purposes of this study were to determine if the intraoperative insertional torque of pedicle screws correlates with the degree of osteoporosis and if insertional torque can be used as a predictor of screw loosening and clinical results in elderly patients. Pedicle screw fixation was performed in 25 patients. Their mean age at the time of surgery was 72.2 years (range 65-79 years). The mean follow-up period was 2.8 years (range 1.0-4.8 years). The insertional torque of the pedicle screws was measured using a Kannon-type torque wrench with a special connector. In the present study, 136 screws were evaluated. The mean insertional torque was 12.2 +/- 5.0 kgf x cm. A negative relation was found between insertional torque and the grade of osteoporosis. Roentgenograms showed the radiolucency of 18 screws in eight patients. Radiolucency appeared as early as 6 months postoperatively. However, there was no significant relation between insertional torque and the presence of screw loosening. Furthermore, there was no significant difference in the clinical results between patients with low insertional torque and those with high insertional torque. This study demonstrated that intraoperative insertional torque is not an objective predictor of screw loosening or clinical results.

Aged↗

Variation in torque production with frequency using medium frequency alternating current.

OBJECTIVES: To investigate the effect of frequency of alternating current on electrically induced torque in healthy subjects, and to establish an optimum frequency for motor stimulation. DESIGN: A repeated-measures design using 12 subjects (part 1) and 3 subjects (part 2). SETTING: A laboratory setting was used. PARTICIPANTS: Participants were volunteers who met the inclusion criteria. INTERVENTIONS: Alternating current with carrier frequencies between 1 and 15kHz, modulated at 50Hz, was applied to each subject on two separate occasions. The frequencies were applied in a different random order on each occasion and different random orders were used between subjects. For part 1 of this study, six frequencies were used: 1, 2, 4, 7, 10, and 15kHz. For part 2, three frequencies were used: 1, 4, and 10kHz. MAIN OUTCOME MEASURES: Part 1: The maximum electrically induced torque, defined as the torque induced at the pain threshold, was recorded for each applied frequency. Part 2: The variation of torque with increasing stimulus intensity was recorded for each applied frequency. RESULTS: Highest electrically induced torque was produced at the lowest frequency examined (1kHz). Torque decreased systematically with increasing frequency over the frequency range examined. The rate of increase in torque with applied stimulus intensity was also found to decrease systematically with increasing frequency in a way that depended strongly on the skinfold thickness of the subject. CONCLUSIONS: Electrical stimulators using an alternating current waveform typically use a carrier frequency in the range of 2kHz to 4kHz for motor stimulation. This study shows that carrier frequencies in this range, modulated at 50Hz, are a compromise between comfort and maximum torque production. For maximum comfort with a low torque, a frequency close to 10kHz is indicated. For maximum torque, a lower frequency of alternating current (1kHz or less) is preferable.

Adult↗

Manual closing torque in five implant abutment systems: an in vitro comparative study.

STATEMENT OF PURPOSE: A significant percentage of abutment/implant (A/I) assemblies tend to unscrew on functional loading. PURPOSE: This in vitro study evaluated the maximum closing torque generated manually for comparison with recommended closing torque values in 5 implant systems. METHODS: Closing torque generated by 9 operators with 5 manual torque drivers was measured and compared by using a mannequin and torque gauge assembly. RESULTS: Closing torque values were found to be significantly different between operators and between implant systems (P <.0001). Mean closing torque values of 9 operators performing 5 closures for 5 systems ranged from 7 to 14.6 N/cm for habitual closures and from 9.4 to 19.9 N/cm for maximum closures. CONCLUSIONS: The results demonstrated that maximum manual closure did not approach recommended closing torque in any of the system measured. Significant interoperator and intraoperator variability was found in the closing torque with manual drivers, and the driver diameter and grip were probably an important feature in the generation of high closing torque.

Analysis of Variance↗

The effect of the use of a counter-torque device on the abutment-implant complex.

STATEMENT OF PROBLEM: Little is known about the condition of the abutment-screw joint before loading, after the development of the preload. PURPOSE: This study examined the tightening force transmitted to the implant with and without the use of a counter-torque device during the tightening of the abutment screw. MATERIALS AND METHODS: Forty Brânemark implants and 10 CeraOne, Estheticone, Procera, and AurAdapt abutments formed the experimental populations. Samples in each group were further divided into 2 groups, 1 group was tightened with a torque controller without the use of a counter-torque device, whereas the other used the counter-torque device. Samples were positioned in a special holder within the grips of a Tohnichi BTG-6 torque gauge for measuring transmitted forces. RESULTS: There were significant differences (P =. 0001) in the tightening forces transmitted to the implant with and without the use of a counter-torque device when tightening the abutment screws. CONCLUSION: An average of 91% of the recommended preload tightening torque was transmitted to the implant-bone interface in the absence of a counter-torque device. In all abutment systems, less than 10% of the recommended preload tightening torque was transmitted to the implant when the counter-torque device was used.

Dental Abutments↗

A comparative study of removal torque of endosseous implants in the fibula, iliac crest and scapula of cadavers: preliminary report.

This study was undertaken to compare removal torque of endosseous implants in the fibula, iliac crest and scapula of cadavers. The fibulae, iliac crests and scapulae were harvested from the right side of 5 formalin-preserved cadavers. Endosseous implants (Brånemark System) were placed at 3 points of each bone. The removal torque of the implant was measured by a torque gauge manometer (Tohnichi 15 BTG-N). After measurement of the removal torque, the bone was cut at each implant site. The thicknesses of cortical and total bone were measured. The mean removal torques were 46.3 N cm in the fibulae, 15.2 N cm in the iliac crests and 21.4 N cm in the scapulae. There was a statistically significant difference in mean removal torque between the three bones. The total bone thicknesses were 11.7 mm in the fibulae, 9.9 mm in the iliac crests and 8.2 mm in the scapulae. The cortical bone thicknesses were 5.0 mm in the fibulae, 1.6 mm in the iliac crests and 1.8 mm in the scapulae. Significant correlation between the removal torque and the cortical bone thickness was found. However there was no significant correlation between the removal torque and the total bone thickness. In conclusion, the implants inserted in the fibulae showed the highest removal torques as compared to the ones inserted in the iliac crests and the scapulae. Moreover the removal torque was related to the thickness of the cortical bone in the implant sites.

Adult↗

Effect of stiffness and movement speed on selected dynamic torque characteristics of hydraulic-actuation joystick controls for heavy vehicles.

The purpose of this work was to quantify the effects of joystick stiffness and movement speed on the dynamic torque characteristics of hydraulic-actuation joystick controls, as found in off-road vehicles, as one of the initial steps towards the development of a joystick design protocol. Using a previously developed mathematical model in which a hydraulic-actuation joystick is assumed to rotate about two axes where the rotation origin is a universal joint, the dynamic torque characteristics incurred by an operator were predicted. Utilizing a laboratory mock-up of an excavator cab environment, three actuation torque characteristics (peak torque, angular impulse and deceleration at the hard endpoint) were quantified for nine unskilled joystick operators during the use of a commonly used North American hydraulic-actuation joystick. The six different experimental conditions included combinations of three joystick stiffnesses and two movement speeds. The highest instantaneous input torque over the course of the joystick movement (not including the hard endpoint) was evaluated using the peak torque value. Angular impulse provided an indication of the sustained exposure to force. The third indicator, deceleration at the hard endpoint, was included to provide a description of impact loading on the hand as the joystick came to a sudden stop. The most important result of this work is that the dynamic torque characteristics incurred during hydraulic-actuation joystick use are substantial. While the peak torque values were not very different between the fast and slow motion conditions, the high decelerations even for slow movements observed at maximum excursion of the joystick indicate that the dynamics do matter. On the basis of deceleration at the hard endpoint and peak torque, the joystick movements that require the highest values for a combination of torque variables are the side-to-side ones. This suggests that less stiff balance and return springs should be considered for these directions than for forward and backward movements. However, if the design does not minimize acceleration, it is important that the spring stiffness not be too low since deceleration at the joystick hard endpoint will be very high causing the operator to incur large palm and finger impacts.

Adult↗

Eccentric knee flexor torque following anterior cruciate ligament surgery.

The purposes of this study were to compare eccentric knee flexor torque and muscle activation in the limbs of normal (NOR) subjects and in subjects who had undergone unilateral ACI, autograft surgical reconstruction (INJ) and to assess the effect of movement speed on EMG/ torque ratios and eccentric-concentric actions. Fourteen subjects (7 NOR and 7 INJ) were tested for knee eccentric flexor torque and EMG activity at four isokinetic speeds (15 degrees, 30 degrees, 45 degrees and 60 degrees.s-1). Results revealed that post-surgical limbs (ACL) produced significantly less (P < 0.05) eccentric torque and flexor EMG activity at 60 degrees.s-1 than uninjured (UNI) contralateral limbs. Eccentric torque rose significantly as speed increased from 45 degrees to 60 degrees.s-1 for surgical group uninjured limbs and NOR group left and right limbs. Eccentric flexor torque increased with speed for both groups and approximated equality with concentric extensor torque at 60 degrees.s-1 for INJ group ACL and UNI limbs. Concentric flexor muscle EMG/torque ratios were 30-191% greater than eccentric muscle actions across groups and speeds. The results suggest that ACL dysfunction may result in reduced eccentric flexor torque at rapid movement speeds, that eccentric flexor torque increases with movement speed and may have the capacity to counter forceful extensor concentric torque, and that eccentric muscle actions produce less muscle activation per unit force than concentric actions which may reflect reduced energy cost.

Adult↗

Relating agonist-antagonist electromyograms to joint torque during isometric, quasi-isotonic, nonfatiguing contractions.

This paper describes an experimental study which relates simultaneous elbow flexor-extensor electromyogram (EMG) amplitude to joint torque. Investigation was limited to the case of isometric, quasi-isotonic (slowly force-varying), nonfatiguing contractions. For each of the flexor and extensor muscle groups, the model relationship between muscle group torque contribution and EMG amplitude was constrained to be a sum of basis functions which had a linear dependence on a set of fit parameters. With these constraints, the problem of identifying the EMG-to-torque relationship was reduced to a linear least squares problem. Surface EMG's from elbow flexors and extensors, and joint torque were simultaneously recorded for nonfatiguing, quasi-isotonic, isometric contractions spanning 0-50% maximum voluntary contraction. Single-/multiple-channel unwhitened/whitened/adaptively whitened EMG amplitude processors were used to identify an EMG-to-torque relation, and then estimate joint torque based on this relation. Each unwhitened multiple-channel EMG-to-torque estimator had a standard error (SE) approximately 70% of its respective single-channel estimator. The adaptively whitened multiple-channel joint torque estimator had an SE approximately 90% of the unwhitened multiple-channel estimator, providing an estimation error approximately 3% of the combined flexion/extension torque range. The experimental studies demonstrated that higher fidelity EMG amplitude processing led to improved joint torque estimation.

Adult↗

Effect of contraction history on torque deficits by stretches of active rat skeletal muscles.

Effects of contraction history on torque deficits by stretches of active skeletal muscles were examined. After three contractions using maximal and submaximal activation (80 and 20 Hz) at an ankle position of 40 degrees (i.e., long muscle length) and with maximal activation at 120 degrees (i.e., short muscle length), the isometric and stretch torques (15 stretches) of rat plantar flexor muscles (bout 1) were measured. Controls were unconditioned. Stretches (i.e., ankle rotation from 90 degrees to 40 degrees, velocity: 50 degrees. s-1) were imposed on maximal isometric contractions at 90 degrees (i.e., preloaded stretches). All groups performed a second bout following 2 hours of rest after bout 1. After maximal contractions at long muscle length, preload torque at 90 degrees and stretch torque at 40 degrees for stretch 1 of bout 1 were 25% and 18% lower than the other groups. However, for all groups, bout 1 ended and bout 2 began and ended with similar isometric and stretch torques. Stretches early in bout 2, with preloads similar to stretches in bout 1, had greater stretch torques resulting in larger torque deficits. Torque deficits, possibly caused by damage to muscle structures and excitation-contraction uncoupling, were not prevented by a history of isometric contractions. Different contraction histories can result in similar isometric torques but different stretch torques.

Animals↗

The torque-velocity relation of elite soccer players.

AIM: The purpose of this study was to describe the torque-velocity (T-V) relationship during concentric and eccentric contractions of the lower limb muscles in professional soccer players. METHODS: Soccer players (n=10) that were training systematically for at least 5 years were compared with moderately active individuals (n=13), that were not engaged in any systematic physical activity program in the last 5 years. Peak torque, and angle-specific torque at knee angles of 0.52 rad and 1.04 rad were evaluated during maximal concentric and eccentric contractions at 0.52 rad x sec(-1), 1.04 rad x sec(-1), 1.57 rad x sec(-1), 2.09 rad x sec(-1), 3.14 rad x sec(-1), 4.19 rad x sec(-1) and 5.23 rad x sec(-1) angular velocities. RESULTS: During concentric contractions, inverse hyperbolic relationships were fitted for the two groups [T = T(max) + (a x b)/(b + V)], with values for a and b of 1.4 and 347.6 for the control group, respectively, and 1.9 and 605.4 for the soccer players, respectively. When torque was measured at 0.52 rad, the torque-velocity relationship presented a plateau at low velocities in the two groups investigated. When torque was measured at 1.04 rad, the torque-velocity relationship presented a plateau at low velocities in the control group, in which force did not increase significantly as velocity was decreased. The plateau was not observed in soccer players. Peak torque and torque measured at 1.04 rad were higher in the soccer players than in the control group in all velocities investigated. However, the biggest difference was found in lower velocities of contraction. CONCLUSION: Soccer players produced a higher muscle torque in the lower limb than moderately active individuals, and this difference was bigger when the velocities were low.

Adult↗

Accuracy of a manual torque application device for morse-taper implants: a technical note.

PURPOSE: The objective of this study was to compare torques applied by new and used manual torque devices for Morse-taper implants. MATERIAL AND METHODS: Fifteen ITI manual torque devices were tested. Those in group 1 (n = 5) were new (ie, never used), those in group 2 (n = 5) had been used 50 to 200 times, and those in group 3 (n = 5) had been used 500 to 1,000 times. The torques applied by each device were measured for 35 Ncm and 15 Ncm targets in an experimental setup by a custom-made wrench with strain gauges connected to a data acquisition system. The strain-gauge signals were simultaneously delivered to a computer at a sample rate of 10,000 Hz and converted to torque units. RESULTS: New devices applied higher torques than used devices for the 35-Ncm torque target (P < .05). The torques applied by group 3 devices were approximately 1.5 Ncm lower than those of other groups for the 35-Ncm target and approximately 1 Ncm lower for the 15-Ncm target. DISCUSSION AND CONCLUSION: ITI manual torque devices deliver consistent torque output, although a slight decrease occurs as a consequence of clinical use.

Dental Implantation, Endosseous↗

Differences in quadriceps femoris muscle torque when using a clinical electrical stimulator versus a portable electrical stimulator.

BACKGROUND AND PURPOSE: There have been conflicting views and evidence reported in the literature concerning differences in muscle torque-generating capacities between clinical ("plug-in") console devices whose power source is provided by an electrical outlet (60 Hz, alternating current-driven) and portable electrical muscle stimulators (smaller, battery-operated stimulators). The purpose of this study was to compare the torque-generating capacity of the quadriceps femoris muscle during neuromuscular electrical stimulation (NMES) between a clinical neuromuscular electrical stimulator (VersaStim 380) and a portable neuromuscular electrical stimulator (Empi 300PV). SUBJECTS: Forty volunteer subjects with no known knee, neurological, or cardiovascular pathology (22 male, 18 female) participated in the study. METHODS: All subjects were tested with the clinical and portable stimulators on 2 separate days. Peak isometric torque of the quadriceps femoris muscle was measured using a Biodex dynamometer. Peak isometric quadriceps femoris muscle torque achieved during NMES and the average quadriceps femoris muscle torque integral produced over 10 NMES contractions were measured for each stimulator. Subjects also rated the amount of pain they experienced during the 10 NMES contractions using a numeric pain scale. Paired t tests were used to compare mean differences in measured variables between stimulator conditions. RESULTS: There were no differences in the peak torque or numeric pain ratings during the electrically stimulated contractions between stimulator conditions. The Empi 300PV produced a greater average torque integral compared with the VersaStim 380 during 10 electrically stimulated contractions (Empi 300PV=988.6-/+330.4 N.m-s, Versastim 380=822.7-/+292.6 N.m-s). DISCUSSION AND CONCLUSION: The portable Empi 300PV stimulator produced comparable levels of average peak torque at comparable levels of discomfort to those produced by the VersaStim 380 clinical stimulator. The Empi 300PV maintained greater amounts of torque production during a 10-contraction training session compared with the VersaStim 380. Based on these data, we believe that the Empi 300PV has the potential to produce adequate levels of torque production for NMES quadriceps femoris muscle performance training. Further study is needed to determine the effectiveness of using the Empi 300PV for quadriceps femoris muscle performance training.

Adult↗

Clinical meaning of the torque between stance leg and ground for the analysis of gait mechanism.

Transversal torque between the stance leg and the ground was measured in 169 test persons with normal gait (91 women, 78 men; ages 15-79 years) using three-dimensional force plates. Taking the average of six to ten single steps produces reproducible person- and group-specific data. This permits the isolation and study of individual solutions to specific problems of locomotion, so-called gait mechanisms. The relatively great torque during the double-stance phase is caused mainly by the medially directed, short-term impact peak at heel strike, with the stride length as lever arm. Double-stance torque is therefore determined by motion dynamics and does not help in understanding individual gait mechanisms. Torque measured during the single-stance phase is, in comparison, rather small and is interindividually relatively variable. Experimentally measured torque is considered in terms of various hypotheses concerning the creation of torque in the human gait. Men obviously tend, for reasons of equilibrium and stability, to compensate the various torques. Better than the more known vertical, sagittal, and frontal force components, the remaining torque represents the individual problem solution and therefore permits the study of specific gait mechanisms, both physiological and pathological. Using the characteristic gait of patients with hemiplegia as an example, it is shown that pathological torque observed systematically on the nonaffected side in such patients is a quantitative measure of the trunk rotation necessary to move the plegic side forward. Measurement of this torque therefore permits precise determination of the degree of damage, as well as quantitative control and objective documentation of the rehabilitation progress.

Adolescent↗

The development of goal-directed reaching in infants. II. Learning to produce task-adequate patterns of joint torque.

Nine young infants were followed longitudinally from 4 to 15 months of age. They performed multi-joint reaching movements to a stationary target presented at shoulder height. Time-position data of the hand, shoulder, and elbow were collected using an optoelectronic measurement system. In addition, we recorded electromyographic activity (EMG) from arm extensors and flexors. This paper documents how control problems of proximal torque generation may account for the segmented hand paths seen during early reaching. Our analysis revealed the following results: first, muscular impulse (integral of torque) increased significantly between the ages of 20 (reaching onset) and 64 weeks. That is, as infants got older they produced higher levels of mean muscular flexor torque during reaching. Data were normalized by body weight and movement time, so differences are not explained by anthropometric changes or systematic variations in movement time. Second, while adults produced solely flexor muscle torque to accomplish the task, infants generated flexor and extensor muscle torque at shoulder and elbow throughout a reach. At reaching onset more than half of the trials revealed this latter kinetic profile. Its frequency declined systematically as infants got older. Third, we examined the pattern of muscle coordination in those trials that exhibited elbow extensor muscle torque. We found that during elbow extension coactivation of flexor and extensor muscles was the predominant pattern in 67% of the trials. This pattern was notably absent in comparable adult reaching movements. Fourth, fluctuations in force generation, as measured by the rate of change of total torque (NET) and muscular torque (MUS), were more frequent in early reaching (20-28 weeks) than in the older cohort (52-64 weeks), indicating that muscular torque production became increasingly smoother and task-efficient. Our data demonstrate that young infants have problems in generating smooth profiles of proximal joint torques. One possible reason for this imprecision in infant force control is their inexperience in predicting the magnitude and direction of external forces. That infants learned to consider external forces is documented by their increasing reliance on these forces when performing voluntary elbow extensions. The patterns of muscle coordination underlying active elbow extensions were basically the same as during the prereaching phase, indicating that the formation of functional synergies is based on a basal repertoire of innervation patterns already observable in very early, spontaneous movements.

Child Development↗

Statistical evaluation of torque angles in reference to straight-wire appliance (SWA) theories.

Inconsistency in torque data on diverse straight-wire appliance (SWA) attachments calls for reassessment of the SWA theories. This study evaluates the SWA theories and suggests predictive torque models. A custom-made torque angle gauge was used on models from 54 ideal occlusion subjects (34 orthodontically treated and 20 untreated cases). This study is in close agreement with Andrews' mean torque values except those for the upper incisors. No agreement is found with Ricketts' torque data. A SD of +/- 5 degrees is characteristic for all teeth. Therefore, the maximal arch wire in a 0.018-inch slot that will not produce deleterious effects is 0.016 X 0.022 inches using Andrews' data and 0.016 X 0.016 inches with Ricketts' data. Neither the setup procedure nor the morphometric parameters predict individual torque data. Intertooth torque correlations indicate that the first premolar in each arch is the tooth of choice for predictive purposes, with unpredictability in the upper arch. Intertooth torque correlations demonstrate a systematic arrangement defined as follows: (1) a lower torque value for a known tooth indicates a lower value for a predicted tooth, (2) neighboring teeth show the strongest coefficient of correlation, and (3) intertooth torque correlations are ranked according to dental fields, showing a similar genetic pattern to tooth morphology.

Adolescent↗

Variations in soleus H-reflexes as a function of plantarflexion torque in man.

The purpose of this study was to evaluate the effects of the levels of voluntary isometric contraction on the Hoffman reflex in human soleus and medial gastrocnemius (MG) muscles. H-reflexes were recorded in sixteen healthy adults at each of 16 isometric plantarflexion (pf) torque levels ranging from 0-100% of their maximum voluntary isometric contraction (MVC) and were elicited at two intensities of stimulation: (i) supramaximal for M-response and (ii) a submaximal stimulus that produced an H-reflex in soleus that was 50% of maximum H-reflex at rest. The H-reflex peak-to-peak amplitudes were linearly related to pf torque levels ranging from 0 to 50% MVC at both supramaximal and submaximal stimulus intensities. The slope of this relationship was higher for the submaximal stimulation. Beyond 60% of MVC, the soleus H-reflex amplitude showed no further increase with increasing pf torque for both stimulus intensities. Thus, beyond 50-60% of MVC the soleus H-reflex does not provide an accurate measure of soleus motor neuron pool excitability. Further experimental results showed that the H-reflex amplitude at a given torque level depended on whether torque was increasing or decreasing. When torque was increasing, the amplitude of the H-reflex was larger than when the same torque was maintained at a constant level. In contrast, if the torque was decreasing, amplitude of the reflex was lower than when torque was increasing. Therefore, variations in H-reflex amplitudes at a given torque level may be more closely correlated to the direction of the ongoing contraction than to the actual muscle force being produced at the time the H-reflex is elicited.

Adult↗

Peak torque occurrence in the range of motion during isokinetic extension and flexion of the knee.

The purpose of this study was to 1) assess the knee angles of hamstring and quadriceps peak torques at slow (60 degrees.sec-1) and moderate (180 degrees.sec-1) isokinetic velocities in healthy adult males (N = 143) and females (N = 106), 2) determine if velocity has an effect on these peak torque angles, and 3) determine if subject's age, sex, and muscle strength have an effect on the results. The Cybex II dynamometer was used to record the measurements. At 60 degrees.sec-1, the mean peak torque for the hamstrings occurred at 33 degrees for men and 37 degrees for women (p < 0.001) (0 degree = full extension). At 180 degrees.sec-1, the corresponding angles were 40 and 44 degrees (p < 0.01). In both groups the increase was 7 degrees (p < 0.001). At 60 degrees.sec-1, the peak torque angle of the quadriceps was 54 degrees in both groups. At 180 degrees.sec-1, the angle occurred significantly later in men (11 degrees later) and in women (10 degrees later) (p < 0.001 for both). Subject's age (18 to 40 years) did not affect the results. In female hamstrings, the knee angle of peak torque had a highly significant (p < 0.001) negative correlation to muscle strength; that is, in female hamstrings, the peak torque angles occurred later in the range of motion when muscle strength decreased. This possibly explained the difference observed between men and women in the peak torque angles of hamstrings. In conclusion, people involved in isokinetic testing of muscular performance should be aware that the peak torque occurs later in the range of motion with increasing angular velocity, especially when testing weak muscle groups. In high angular velocities this may become a problem since the limb may pass the optimal joint position for muscular performance, and the recorded peak torque may not represent the subject's maximal torque capacity.

Adult↗