Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Pulsatile Flow”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

Bi-directional cavopulmonary shunt: is accessory pulsatile flow, good or bad?

OBJECTIVE: Evaluation of the effect and long-term outcome of accessory pulsatile blood flow versus classical bi-directional cavopulmonary connection (BCPC). METHODS: Retrospective review of the medical and surgical records. RESULTS: Two-hundred and five patients (119 boys, 86 girls) underwent BCPC from 1990 to 1996. Accessory pulsatile flow was present in 68%, flow being maintained through the pulmonary trunc in 46%, systemic-to-pulmonary artery shunt in 13% and mixed in 7%, or patent ductus arteriosus in 2%. Patients with accessory pulsatile flow had lower hospital mortality (3% versus 5%), while mean pulmonary artery pressure (14.1 versus 12.6 mmHg P = 0.050) and increase of oxygen saturation (12.4 versus 8.7, P = 0.034) were significantly higher. The period of artificial ventilation (1.9 day) and ICU stay (6 days) did not differ for both groups. Late mortality was higher following accessory pulsatile flow (6% versus 1%). At late follow-up patients with accessory pulsatile flow had significantly higher oxygen saturation (mean 85 +/- 4%, versus 79 +/- 4%; P < or = 0.005). If subsequent completion of Fontan is considered the optimal palliation and subsequent systemic to pulmonary artery shunt, arteriovenous fistula and transplantation is considered a failure, patients with accessory pulsatile flow had significantly more and earlier completion of the Fontan procedure (mean 1.7 +/- 2.4 years, versus 2.7 +/- 4.4 years; P = 0.008). Survival is not influenced by age at bi-directional cavopulmonary shunt surgery, left or right functional ventricular anatomy or previous palliative surgery. One patient with accessory pulsatile flow developed systemic-to-pulmonary collateral's eventually requiring lobectomy. CONCLUSION: Despite two different initial palliative techniques the outcome was not significantly different. Accessory pulsatile blood flow appeared not to be a contra-indication for a completion Fontan procedure. Moreover, the data suggest that after accessory pulsatile flow can safely be performed, at late follow-up oxygen saturation is higher, while, significantly more and earlier completion of Fontan occurred. Age at bi-directional cavopulmonary shunt, basic left or right ventricular anatomy or previous palliative surgery did not influence survival.

Adolescent↗

Magnetic resonance assessment of the pulmonary arterial trunk anatomy, flow, pulsatility and distensibility.

We used magnetic resonance imaging with cine velocity mapping to study the anatomy of pulmonary bifurcation and to measure volume blood flow, pulsatility of flow and arterial wall distensibility in the central pulmonary arteries of nine healthy volunteers. Multislice, multiplane spin echo images were acquired to display pulmonary bifurcation anatomy. Diameters of the main pulmonary artery (MPA) in systole were 2.56 +/- 0.35 cm and in diastole 2.20 +/- 0.33 cm. Those of the right pulmonary artery (RPA) were 1.57 +/- 0.29 cm and 1.39 +/- 0.23 respectively, and of the left pulmonary artery (LPA) 1.79 +/- 0.26 cm and 1.55 +/- 0.10 cm respectively. A gradient echo sequence with phase shift velocity mapping was then used to measure flow in MPA, RPA and LPA 2 cm on either side of the pulmonary bifurcation. Time averaged flow, calculated from mean velocity and the cross-sectional area of the vessels was 4.99 +/- 1.10 l.min-1 in MPA, 2.23 +/- 0.58 l.min-1 in RPA and 2.31 +/- 0.63 l.min-1 in LPA. The pulsatility index of flow derived from peak forward flow, peak backward flow and time averaged flow were as follows: MPA 4.4 +/- 0.8, RPA 5.1 +/- 0.6 and LPA 4.6 +/- 1.5. Distensibility, calculated from the change in cross-sectional area between diastole and systole and expressed as percentage were as follows: MPA 25.6 +/- 10.7, RPA 21.4 +/- 10.7 and LPA 24.5 +/- 7.8. MRI with velocity mapping accurately characterized anatomy, flow, distensibility and pulsatility of the central pulmonary arteries.

Adult↗

Preload-responsive, pulsatile-flow, externally valved pump: cardiopulmonary bypass.

Currently two pumps are used for cardiopulmonary bypass, the roller pump and the centrifugal or vortex pump. Both are steady-flow pumps. The procedure of cardiopulmonary bypass possesses a finite morbidity and mortality. The degree to which steady flow is responsible for this morbidity and mortality remains to be clarified, but investigators have established the fact that a physiologic degree of pulsatile flow must be achieved before its beneficial results, such as normal systemic resistance and absence of lactate production, can be demonstrated. Availability of a satisfactory pulsatile pump for cardiopulmonary bypass has been a problem in the past but the pump presented here may satisfy this need. It produces physiologic pulsatility with rate dependent ejection time equal to or less than that of humans (413 microseconds minus 1.7 times heart rate), and it is preload-responsive, varying its pumping rate and output with filling pressure. The pump is externally valved to minimize hemolysis, which has been demonstrated in two laboratory studies to be significantly less than with the roller pump. It produces pulsatile flow through membrane oxygenators. The pump is thought to have potential for several clinical applications in addition to (1) pulsatile-flow cardiopulmonary bypass, including (2) left, right, or combined transthoracic QRS synchronized ventricular assist, (3) femoral vein to femoral artery QRS synchronized left ventricular assist, (4) adult or infant ECMO, (5) pulsatile flow hemodialysis. In the latter, spallation and embolization of hemodialysis tubing particles should not be a problem as has proved to be the case with the present hemodialysis pump.

Cardiopulmonary Bypass↗

Sustained pulsatile flow regulates endothelial nitric oxide synthase and cyclooxygenase expression in co-cultured vascular endothelial and smooth muscle cells.

This study addresses the effect of sustained increased pulsatile flow on nitric oxide synthase (NOS) and cyclooxygenase (Cox) expression and activity in co-cultured endothelial cells (EC) and vascular smooth muscle cells (SMC). Using a perfused transcapillary co-culture system which permits the chronic exposure of cultured EC and SMC to physiological shear stresses, co-cultures were exposed to step-wise increases in flow up to: (i) 2 ml/min (low flow: 0.5 dyn/cm2): or (ii) 44 ml/min (high flow: 15 dyn/cm2) and maintained for 72 h before SMC and EC were harvested separately. There was no NOS activity or protein expression in co-cultured SMC under flow conditions. There was a significant increase in eNOS activity in co-cultured EC under high flow conditions, compared to low flow, which correlated with an increase in eNOS expression and mRNA levels. The flow-induced increase in eNOS activity was potentiated by indomethacin treatment, suggesting a modulatory role for a cyclooxygenase product. Prostacyclin levels in co-culture perfusate were significantly elevated under high flow conditions. While both co-cultured EC and SMC expressed cyclooxygenase (Cox-I and Cox-II), they were differentially regulated by pulsatile flow, EC Cox-I and Cox-II protein expression were both decreased. Indomethacin treatment increased the expression of both Cox-I and Cox-II in co-cultured SMC under high flow conditions. We conclude that sustained increases in pulsatile flow maintain elevated eNOS and Cox protein expression and activity in EC while decreasing Cox expression in co-cultured SMC. These data suggest that regulation of these pathways may contribute to flow-induced vascular remodeling in vivo.

Animals↗

Pulsatile flow past aortic valve bioprostheses in a model human aorta.

Pulsatile flow development past tissue valve prostheses in a model human aorta has been studied using qualitative flow visualization and quantitative laser-Doppler techniques. Experiments were conducted both in steady and physiological pulsatile flow situations and the measurements included the pressure drop across the valve, the instantaneous flow rate as well as the velocity profiles and turbulent stresses downstream to the valves. Our study shows that the velocity profiles with pericardial valves are closer to those measured past natural aortic valves. The porcine valves with a smaller valve opening area produce a narrower and stronger jet downstream from the valve with relatively larger turbulent axial stresses in the boundary of the jet. Our study suggests that the pericardial valves with turbulent stresses comparable to those of caged ball and tilting disc valves are preferable from a hemodynamic point of view.

Animals↗

Casson fluid model for pulsatile flow of blood under periodic body acceleration.

Pulsatile flow of a Casson fluid under the influence of a periodic body acceleration has been studied in this paper. An implicit finite difference numerical procedure has been used to analyze the flow. Applicability of this method has been checked by comparing the obtained results with the analytical solution for Newtonian flow and explicit scheme solution. The agreement between the implicit and explicit scheme solutions and the analytical solution is good (error less than 1%). Flow variables have been computed at three locations in cardiovascular system (wide (femoral) and narrow (arteriole and coronary) tubes). Effects of yield stress, tube radius and pressure gradient combined, body acceleration amplitude and frequency etc., on flow have been studied. The following observations have been made: (i) Initial transient time It changes with yield stress in narrow tubes are insignificant, whereas in wide tubes It decreases with yield stress; (ii) The axial velocity and fluid acceleration variations with yield stress are uniform (changes only quantitatively, profiles shape remain same) in narrow tubes, whereas in wide tubes these variations are non-uniform (profiles change qualitatively as well as quantitatively); (iii) Yield stress effects on wall shear amplitude are insignificant in narrow tubes (congruent to 0.3% in arteriole and congruent to 6% in femoral); and (iv) For Newtonian fluid, mean flow rate does not change with body acceleration amplitude a0 and frequency fb but it increases (decreases) with a0(fb) for Casson fluid.

Acceleration↗

[The numerical simulation of pulsatile flow in a tapered blood vessel].

The tapered blood vessel is associated with the human physiological pulsatile blood flow in this study to address the questions about the developing flow. The geometry model of tapered blood vessel, theoretical models of blood flow, physiological boundary conditions and calculation conditions are proposed. An average blood flow function is established according to the physiological pulsatile flow conditions. The pulsatile flow in a 3-D tapered blood vessel is simulated numerically with the flow function. The distributions of velocity and pressure on different time of the cardiac cycle are obtained. The numerical simulation outcomes are compared with the experimental and analytical results. The characteristics of the pulsatile flow in a tapered blood vessel are discussed in this paper.

Blood Circulation↗

Scaling laws for wall shear stress through stenoses under steady and pulsatile flow conditions.

Most patients with atherosclerosis exhibit isolated stenoses of one or more epicardial coronary arteries. The wall shear stresses produced in high-grade stenosis are important in the understanding of atheromatous plaque rupture and thrombosis. This study is designed to establish a method which can be used to scale the different wall shear stresses obtained under different flow conditions to be normalized and subsequently collapsed on to a single general curve. The simulations include both steady and pulsatile flow. The reduced area percentages of the stenoses studied are 50, 75 and 90 per cent. Scaling laws for steady and pulsatile flow conditions are proposed and presented. It can be found from the results that the scaling analysis for pulsatile flow conditions is more complicated than for steady flow conditions and is restricted to, and only valid at, certain time intervals.

Arteriosclerosis↗

Pulsatile flow artifacts in fast magnetization-prepared sequences.

Fast magnetization-prepared magnetic resonance imaging sequences allow clinical acquisitions in about 1 second, with the preparation phase providing the desired contrast. Pulsatile flow artifacts, although reduced by rapid acquisition, can degrade image quality. The authors explore the causes of aortic pulsatile flow artifacts in inversion-recovery-prepared acquisitions of the abdomen, taking into consideration various parameters. The flow signal within an 8-mm-thick section was simulated and subsequently Fourier transformed to determine the location and extent of flow artifacts. Results of simulations were validated with abdominal images of human subjects. Recording all encodings within one cardiac cycle reduced pulsatile flow artifacts in nonsegmented acquisitions with sequential phase-encoding order, regardless of the location of magnetization preparation within the cardiac cycle. In segmented acquisitions, however, the sequential order always increased flow artifacts. To reduce the artifacts in short TI acquisitions, the magnetization should be prepared during diastole. In clinical acquisitions, flow artifacts were further reduced by modifying the phase-encoding scheme.

Aorta, Abdominal↗

Flow-induced wall shear stress in abdominal aortic aneurysms: Part II--pulsatile flow hemodynamics.

In continuing the investigation of AAA hemodynamics, unsteady flow-induced stresses are presented for pulsatile blood flow through the double-aneurysm model described in Part I. Physiologically realistic aortic blood flow is simulated under pulsatile conditions for the range of time-average Reynolds numbers 50< or =Re(m) < or =300. Hemodynamic disturbance is evaluated for a modified set of indicator functions which include wall pressure (p(w)), wall shear stress (tau(w)), Wall Shear Stress Gradient (WSSG), time-average wall shear stress (tau(w)*), and time-average Wall Shear Stress Gradient WSSG*. At peak flow, the highest shear stress and WSSG levels are obtained at the distal end of both aneurysms, in a pattern similar to that of steady flow. The maximum values of wall shear stresses and wall shear stress gradients are evaluated as a function of the time-average Reynolds number resulting in a fourth order polynomial correlation. A comparison between numerical predictions for steady and pulsatile flow is presented, illustrating the importance of considering time-dependent flow for the evaluation of hemodynamic indicators.

Aorta, Abdominal↗

Achievement of physiologic pulsatile flow on cardiopulmonary bypass with a 24 French cannula.

In 1990, the NIH formally recognized the need for investigation of the problem of damaging the effects of cardiopulmonary bypass, issuing RFA HL-90-12-H, which emphasized production of neurologic defects in the very young and the elderly. The authors were at that time involved in comparison of pulsatile flow to steady flow cardiopulmonary bypass in large ungulates. The world literature recognizes five damaging effects of steady flow cardiopulmonary bypass that can be mitigated by pulsatile flow: metabolic acidosis, interstitial fluid accumulation, elevated systemic vascular resistance, arteriovenous shunting, and impaired brain oxygenation. To maximize the beneficial effect of pulsatile flow, however, it is necessary that its morphology be physiologic. It has been stated in the past that this goal may not be possible using standard size aortic cannulas. The purpose of this publication is to describe a method by which this feat has been achieved in 150 pound ungulates undergoing prolonged cardiopulmonary bypass.

Animals↗

Clinical evaluation of pulsatile flow mode of Terumo Capiox centrifugal pump.

The Terumo Capiox centrifugal pump system possesses an automatic priming function in which the motor repeatedly stops and runs intermittently to eliminate air bubbles in the circuit through the micropores of the hollow-fiber membrane oxygenator. By modifying this mechanism, we have developed a pulsatile flow mode. In this mode, maximum and minimum pump rotational speeds can be independently set every 20 rpm in the range of 0 to 3,000 rpm. The duration of the pump run at maximum and minimum speeds can also be independently set every 0.1 s in the range of 0.2 to 15 s. In a clinical trial, after obtaining the desired flow rate, 2.4 L/min/m2 in nonpulsatile flow mode, a pulsatile flow mode of 60 cycles/min (with 1 cycle being maximum speed for 0.4 s and minimum speed for 0.6 s) was obtained by adding and subtracting 500 rpm to and from the rotational speed in nonpulsatile flow mode. Pulse pressures in the femoral artery and in the circuit just proximal to the perfusion cannula (6.5 mm Sarns high flow cannula with metal tip) were measured in 5 patients who underwent pulsatile cardiopulmonary bypass (CPB) for a coronary artery bypass graft (CABG), and compared to pulse pressures obtained by intraaortic balloon pumping (IABP) in 3 patients and by the pulsatile mode of the 3M Delphin pump in 3 patients. The platelet count, free hemoglobin, and beta-thromboglobulin (beta-TG) were measured and compared with measurements from another 5 patients who underwent nonpulsatile CPB. Although the pulse pressure measured in the circuit was 180 mm Hg on average, the pressure in the femoral artery was only 15 to 40 mm Hg with a mean of 20 mm Hg. In the same patients, 60 to 80 mm Hg pulse pressure was obtained with IABP. The pulse pressure obtained with the Delphin pump was not more than that obtained with the Terumo pump. There were no significant differences in percents of preoperative levels of platelet counts (pulsatile, 87.6 +/- 15.8% and nonpulsatile, 72.4 +/- 40.6%), free hemoglobin (pulsatile, 18 +/- 8 mg/dl and nonpulsatile, 25 = 7 mg/dl), and beta-TG (pulsatile 298 +/- 28 ng/ml and nonpulsatile, 312 +/- 143 ng/ml). In conclusion, although the pulsatile mode of the Terumo centrifugal pump did not exhibit any adverse effects hematologically, the pulse pressure obtained was unsatisfactorily small, mainly because of dumping caused by the perfusion cannula.

Angina Pectoris↗

An experimental study of pressure losses in pulsatile flows through rigid and pulsating stenosis.

The time-dependent pressure curves of a pulsatile flow across rigid and pulsating stenoses were investigated experimentally in a laboratory simulator of the outflow tract of the heart right ventricle. The experiments were performed within the range of physiological conditions of frequency and flow rate. The experimental setup consisted of a closed flow system which was operated by a pulsatile pump, and a test chamber which enabled checking different modes of stenosis. Rigid constrictions were simulated by means of axisymmetric blunt-ended annular plugs with moderate-to-severe area reductions. The pulsating stenosis consisted of a short starling resistor device operated by a pulsating external pressure which was synchronized by the pulsatile flow. It was found that the shape of the time-dependent pressure curve upstream of the stenosis was different in the case of rigid stenosis than in the pulsating one. Potential clinical applications of the work may relate to diagnosis of the type of stenosis in the congenital heart disease known as Tetralogy of Fallot.

Biomechanical Phenomena↗

Assessment of ventricular filling volumes with an automated color Doppler method: validation in a pulsatile flow model.

OBJECTIVE: Determination of ventricular filling volumes with the use of Doppler echocardiographic measurements critically depends on the presence of a circular-shaped flow area and a flat velocity profile across it because evaluation of flow volume is usually based on echocardiographic measurements of its diameter and pulsed Doppler recordings within the center of this area. The approach may be limited at the mitral and tricuspid ring levels as a result of their noncircular shape and because nonflat velocity profiles are present. The purpose of this study was to examine in a pulsatile flow model simulating ventricular inflow conditions the accuracy of an automated method based on the analysis of color Doppler flow velocities for evaluation of flow volumes. MATERIALS AND METHODS: A recently-developed automated Doppler method that takes into account the velocity distribution across a region of interest was examined in a pulsatile flow model by using flows with waveforms characteristic for ventricular inflow through tubes with elliptically-shaped cross-sectional areas. Color Doppler imaging was performed against flow direction along the major and minor axes of the tubes with major diameters ranging between 3 and 5 cm and major-to-minor diameter ratios of 1.5 and 2.0. RESULTS: A close correlation was found between flow volumes measured by the Doppler technique for registrations along the minor or major axis of the ellipses and actual values (r = 0.99, standard error of the estimate = 0.44 to 1.98 mL), with a systematic underestimation or overestimation, respectively, depending on the diameter ratio. Averaging of the data derived from 2 orthogonal measurements by using the geometric mean value yielded an excellent agreement between Doppler data and actual flow volumes. CONCLUSION: This automated color Doppler method enables reliable determination of flow volumes in a pulsatile flow model simulating ventricular inflow conditions with the use of 2 orthogonal imaging views. The data indicate that the method may improve the noninvasive evaluation of ventricular filling volumes.

Echocardiography, Doppler, Color↗

Comparison of theory and experiment in pulsatile flow in cat lung.

A mathematical model of pulsatile flow in cat lung based on existing morphometric and elastic data is presented and validated by experimental results. In the model, the pulmonary arteries and veins were treated as elastic tubes, whereas the pulmonary capillaries were treated as two-dimensional sheets. The macro- and microcirculatory vasculature was transformed into an analog electrical circuit. Input impedances of the pulmonary blood vessels of every order were calculated under normal physiological conditions. Pressure-flow relation of the whole lung was predicted theoretically. Experiments on isolated perfused cat lungs were carried out. The relation between pulsatile blood pressure and blood flow was measured. Comparison of the theoretically predicted input impedance spectra with those of the experimental results showed that the modulus spectra were well predicted, but significant differences existed in the phase angle spectra between the theoretical predictions and the experimental results. This latter discrepancy cannot be explained at present and needs to be further investigated.

Animals↗

Flow characteristics past jellyfish and St. Vincent valves in the aortic position under physiological pulsatile flow conditions.

Thrombus formation and hemolysis have been linked to the dynamic flow characteristics of heart valve prostheses. To enhance our understanding of the flow characteristics past the aortic position of a Jellyfish (JF) valve in the left ventricle, in vitro laser Doppler anemometry (LDA) measurements were carried out under physiological pulsatile flow conditions. The hemodynamic performance of the JF valve was then compared with that of the St. Vincent (SV) valve. The comparison was given in terms of mean systolic pressure drop, back flow energy losses, flow velocity, and shear stresses at various locations downstream of both valves and at cardiac outputs of 3.5 L/min, 4.5 L/min, and 6.5 L/min respectively. The results indicated that both valves created disturbed flow fields with elevated levels of turbulent shear stress as well as higher levels of turbulence in the immediate vicinity of the valve and up to 1 diameter of the pipe (D) downstream of the valve. At a location further downstream, the JF valve showed better flow characteristics than the SV in terms of velocity profiles and turbulent shear stresses. The closure volume of the SV valve was found to be 2.5 times higher than that of the JF valve. Moreover, the total back flow losses and mean systolic pressure drop also were found to be higher in the SV than the JF valve.

Aortic Valve↗

Pulsatile flow simulator for comparison of cardiac output measurements by electromagnetic flow meter and thermodilution.

This study examined a pulsatile flow simulator for the purpose of evaluating two measurement devices, an extracorporeal flow probe with an electromagnetic flow meter and several thermodilution catheters. We measured the performance of these devices in a range of low to high flows. Using either saline or blood as a perfusate, we obtained different results with these fluids (p less than 0.001). Each catheter behaved in a linear manner, although variation occurred among the catheters with both saline (minimum slope 1.090, maximum slope 1.190) and blood (minimum slope 1.107, maximum slope 1.154). An increase in rate and stroke volumes of the simulator did not demonstrate an identifiable trend in error. The thermodilution catheters were most accurate at 5.0 L/min irrespective of rate, stroke volume, or perfusate used. In contrast, the electromagnetic flow meter accurately represented flows across the wide range of outputs examined (2.4 to 10.7 L/min). (Slope with saline 1.091, slope with blood 1.080) Throughout the range of flow, the flow meter gave a calibration line 5% higher with blood than with saline. The results indicate that accurate measurement of pulsatile blood flow can be achieved in vitro with an electromagnetic flow meter using saline as a perfusate, provided a correction factor is determined and applied to convert values for saline to accurate values for blood.

Blood Flow Velocity↗