Search PubMedSearch

SEARCH · Search PubMed

Results for “Proximal Femoral Fractures”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

96 records · Page 6Linked to original sources

Clinical performance of monolithic and veneered zirconia three-unit posterior FDPs: A five-year multicenter randomized controlled trial.

AIM: This randomized controlled clinical study compared monolithic, partially veneered, and fully veneered zirconia FDPs over a 5-year period with respect to survival, technical and biological complications, and patient-reported outcome measures (PROMs). MATERIALS AND METHODS: Sixty-four patients requiring three-unit posterior FDPs were randomly allocated to monolithic (MONO-FDP), partially veneered (PV-FDP), or fully veneered (FV-FDP) groups. All FDPs were fabricated from 4 mol% Y₂O₃ partially stabilized zirconia (4Y-TZP). Follow-up examinations were conducted at baseline, 1, 3, and 5 years. Technical parameters were evaluated using modified USPHS criteria. Periodontal measurements (PPD, BOP, PI) and patient satisfaction were assessed at all time points. RESULTS: A total of 63 FDPs were evaluated at baseline, 57 at 3 years, and 54 at 5 years. Survival at 5 years was 94.7% for MONO-FDPs, 100% for FV-FDPs and 100% for PV-FDPs. Technical complications occurred exclusively in PV-FDP (33%) and FV-FDP (38%) groups and consisted of minor, polishable chipping; no chipping or fractures were recorded in MONO-FDPs (0%) with statistically significant difference between MONO-FDP and the other two groups (p ≤ 0.014). Biological parameters remained stable across all groups, with no significant differences in PPD, BOP, or PI. PV-FDPs and FV-FDPs tended to receive more favorable professional color ratings, whereas PROMs were similar among the groups. CONCLUSIONS: All three FDP designs-monolithic, partially veneered, and fully veneered-fabricated from 4Y-TZP zirconia demonstrated excellent 5-year clinical performance. Technical complications were limited to PV- and FV-FDPs and consisted of minor chipping. Biological outcomes and patient satisfaction were similar across groups. CLINICAL SIGNIFICANCE: The five-year outcomes suggest that veneered, partially veneered, and monolithic FDPs can be used with high clinical reliability; however, restorations incorporating veneering ceramic may present an elevated risk of ceramic chipping.

Humans

Application of Three-Dimensionally Printed Surgical Guides in Precise Sacral Tumor Excision and Defect Reconstruction.

OBJECTIVE: Precise resection of sacral tumors remains technically demanding due to their deep anatomical location and close proximity to critical neurovascular structures. Conventional freehand techniques often result in suboptimal resection margins, excessive blood loss, and compromised lumbopelvic stability. This study evaluated whether patient-specific three-dimensional (3D)-printed guiding templates improve surgical accuracy and perioperative outcomes in sacral tumor resection and reconstruction. METHODS: Nineteen patients undergoing en bloc sacral tumor resection (S1-S3 involvement) with spinopelvic reconstruction (2006-2020) were retrospectively analyzed. Patients were divided into a 3D-printing group (n&#x2009;=&#x2009;10) and a conventional freehand group (n&#x2009;=&#x2009;9). In the 3D-printing group, computer-aided design and 3D-printed templates were used for osteotomy, screw placement, and defect reconstruction. Perioperative metrics, surgical accuracy, and complications were compared between groups using Welch's t-test and the Hodges-Lehmann method; oncologic events during follow-up were recorded descriptively. RESULTS: The 3D-printing group demonstrated significantly shorter operative time (456.5&#x2009;&#xb1;&#x2009;62.36 vs. 574.44&#x2009;&#xb1;&#x2009;114.58&#x2009;min, p&#x2009;=&#x2009;0.012), reduced blood loss (4081.40&#x2009;&#xb1;&#x2009;838.99 vs. 5090.0&#x2009;&#xb1;&#x2009;1059.67&#x2009;mL, p&#x2009;=&#x2009;0.034), and fewer fluoroscopic exposures (4.2&#x2009;&#xb1;&#x2009;0.79 vs. 10.0&#x2009;&#xb1;&#x2009;1.58, p&#x2009;<&#x2009;0.001) compared with the conventional group. Osteotomy accuracy was also superior in the 3D-printing group, with significantly lower angular deviation (3.33&#xb0;&#x2009;&#xb1;&#x2009;0.45&#xb0; vs. 6.79&#xb0;&#x2009;&#xb1;&#x2009;2.16&#xb0;, p&#x2009;=&#x2009;0.0012). Postoperative complication rates were comparable (30% vs. 44.4%, p&#x2009;=&#x2009;0.649), but hospital stay was significantly shorter in the 3D-printing group (10.7&#x2009;&#xb1;&#x2009;2.71 vs. 18.11&#x2009;&#xb1;&#x2009;4.01&#x2009;days, p&#x2009;<&#x2009;0.001). CONCLUSION: Patient-specific 3D-printed guiding templates enhance precision in sacral tumor excision and reconstruction, improving surgical efficiency and perioperative safety. This computer-assisted, template-guided approach represents a valuable advancement for complex sacral oncologic surgery.

Humans

Physician-Modified Fenestrated Stent-Grafts Planned Using Three-Dimensional Techniques for Complex Aortic Pathology: A Systematic Review and Meta-Analysis.

BACKGROUND: Complex aortic pathology involving the visceral arteries remains a significant therapeutic challenge. Open repair is associated with considerable perioperative risk, particularly in patients with multiple comorbidities, while standard endovascular aneurysm repair (EVAR) is often not feasible because of inadequate proximal sealing zones. Fenestrated and branched endovascular repair (F/BEVAR) represents an established treatment strategy; however, the use of custom-made devices is limited by manufacturing time and availability. Physician-modified stent grafts (PMSGs) have therefore emerged as a pragmatic alternative. Three-dimensional planning techniques have been increasingly used to facilitate accurate graft modification. The aim of this systematic review and meta-analysis was to evaluate the effectiveness and safety of PMSG procedures planned with three-dimensional techniques. Technical success, target vessel patency, early mortality, endoleak occurrence, and reintervention rates were analyzed. METHODS: A systematic search was conducted in the PubMed/MEDLINE and Embase databases. Studies describing the use of physician-modified fenestrated stent grafts planned with three-dimensional tools were included. Meta-analyses were performed using a random-effects model with restricted maximum likelihood estimation. A logit transformation was used for the analysis of proportions. RESULTS: The analysis included five studies involving 172 patients. The estimated weighted mean follow-up duration was 14.9 months. The overall technical success rate was 92.9% (95% confidence interval [CI]: 84.5-96.9%), with low-to-moderate heterogeneity. Target vessel patency was 96.9% (95% CI: 93.6-98.5%). Early mortality was 5.5% (95% CI: 2.1-13.3%). The incidence of endoleaks was 13.3% (95% CI: 5.8-27.4%), with significant heterogeneity among studies. Reinterventions were reported in 6.6% of patients (95% CI: 2.3-17.5%). CONCLUSION: The results indicate that PMSG procedures planned with three-dimensional techniques are associated with a high rate of technical success and preserved patency of target vessels in patients with complex aortic pathology. The observed variability in endoleak and reintervention rates likely reflects differences in anatomical complexity and patient selection among studies. Further prospective studies are needed to confirm long-term outcomes.

Humans

The impact of an intact rotator cuff on the outcomes of reverse shoulder arthroplasty: a meta-analysis of 20,924 patients.

BACKGROUND: While reverse shoulder arthroplasty (rTSA) is commonly utilized for rotator cuff tear arthropathy, indications have expanded to include, primary glenohumeral osteoarthritis (GHOA) with intact cuff. The presence of an intact cuff may influence outcomes after rTSA because preserved cuff musculature can contribute to shoulder stability and force which could potentially improve postoperative function and reduce complication rates. However, studies have reported contradictory results on whether or not an intact cuff would provide better outcomes in patients receiving an rTSA. METHODS: This is a systematic review and Meta-analysis performed according the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. PubMed, Cochrane, Embase, and Google Scholar (pages 1-20) were queried through December 2025. Inclusion criteria consisted of studies comparing the outcomes of rTSA based on whether patients had a diagnosis of GHOA with intact cuff, or had a deficient rotator cuff (ie had a diagnosis of rotator cuff tears without OA, or cuff tear arthropathy). Extracted data included adverse events, improvement in patient reported outcome measures, and improvement in range of motion. RESULTS: Eleven retrospective articles and 1 prospective article met the inclusion criteria with 4,542 in the GHOA with intact cuff group and 16,382 in the cuff-deficient group (cuff tear arthropathy: 15,423 patients; rotator cuff tear: 959 patients). Patients undergoing rTSA for GHOA and intact cuff had a lower rate of revisions (odds ratio [OR] = 0.53; 95% CI: 0.41- 0.68, P < .001; I2 = 0%), overall complications (OR = 0.57; 95% CI: 0.46-0.71, P < .001; I2 = 0%), acromial stress fracture (OR = 0.22; 95% CI: 0.08- 0.59, P = .003; I2 = 0%), infection (OR = 0.43; 95% CI: 0.26- 0.73, P = .002; I2 = 37%), and instability (OR = 0.60; 95% CI: 0.40- 0.90, P = .01; I2 = 0%). In addition, GHOA patients had a better improvement in both American Shoulder and Elbow Surgeons scores (mean difference = 7.17; 95% CI: 2.13- 12.21, P = .005; I2 = 81%) without exceeding the minimal clinically important difference, and external rotation (mean difference = 12.00&#xb0;; 95% CI: 9.63- 14.37, P < .001; I2 = 38%). CONCLUSION: Rotator cuff-deficient patients undergoing rTSA have a higher risk of postoperative complications compared to patients undergoing rTSA for GHOA with an intact cuff. They also showed less improvement in American Shoulder and Elbow Surgeons scores and external rotation. However, the clinical significance of these differences should be interpreted with caution, as not all improvements exceeded established thresholds for clinical importance.

Humans

GLP-1 Receptor Agonists and Musculoskeletal Outcomes: A Systematic Literature Review and Meta-Analysis.

INTRODUCTION: Glucagon-like peptide-1 receptor agonists (GLP-1 RAs) are increasingly used for the treatment of type 2 diabetes and obesity, but their effects on musculoskeletal health remain completely misunderstood. OBJECTIVE: This systematic review/meta-analysis aims to synthesise clinical data on the effects of GLP-1 RAs on key relevant bone, muscle, and joint outcomes. METHODS: MEDLINE, Cochrane Central Register of Controlled Trials (CENTRAL) (both via Ovid&#xae; platform) and Embase were searched from inception to March 2025 to identify relevant randomised controlled trials (RCTs) or real-world evidence (RWE) studies to be included. This bibliographic search was completed manually. A random-effect model meta-analysis was performed for any outcome reported in at least 2 studies. Subgroup analyses were performed on the type of GLP-1 RAs, type of comparator used and study design. Sensitivity analyses (i.e., leave-out sensitivity analyses and analyses restricted to the most adjusted effect estimate) were performed to test the robustness of the data. The strength of evidence was assessed using GRADE. This work has been performed in adherence with PRISMA statement. (PROSPERO Record ID: CRD420251024082). RESULTS: From 1148 potentially relevant references, 60 articles (46 RCTs, 13 RWE studies and 1 pharmacovigilance study, comprising 1,250,717 individuals) met our inclusion criteria. Different GLP-1 RAs were represented across the panel of studies, i.e., semaglutide, liraglutide, exenatide, dulaglutide, tirzepatide (dual agonist gastric inhibitory polypeptide [GIP]/GLP-1) and others. No effect on bone outcomes (i.e., bone mineral density [all sites] and fractures [all sites]) were observed when the meta-analytical models included the most adjusted effect size. Regarding muscle outcomes, a significant decrease of lean body mass/fat-free mass was consistently observed with GLP-1 RAs in the global model (k = 28, standardised mean difference [SMD] 0.52, 95% confidence interval [CI] -0.8; -0.23, I2 88%, p-value for heterogeneity <0.0001), which remained robust in all sensitivity analyses. Subgroup analyses showed that the effect was mainly driven by liraglutide and semaglutide, with a decrease in lean body mass/fat-free mass observed when GLP-1 RAs were compared with placebo. No publication bias was found. Regarding joint outcome, models revealed no significant change in The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain, physical function and stiffness. CONCLUSIONS: This meta-analysis is the first to investigate the effects of GLP-1 RAs on a large panel of musculoskeletal health outcomes. While no significant effects were observed on bone- or joint-related outcomes, GLP-1 RAs were associated with reductions in lean body mass/fat-free mass, although the certainty of evidence was low and these changes appeared largely related to weight loss. Whether these changes translate into clinically meaningful impairments in muscle function or physical performance remains uncertain. Further studies in this field, including those looking at muscle function, strength or performance and using multivariate models considering confounding are needed to better reinforce the models and final findings.

Journal Article

Ibuprofen versus acetaminophen for acute mild-to-moderate pain management in pediatric populations: a systematic review and meta-analysis of their efficacy.

UNLABELLED: Ibuprofen and acetaminophen are the most widely used analgesics in pediatric practice for the management of acute mild-to-moderate pain. Despite their widespread use, the comparative analgesic efficacy of these two agents in children remains a subject of ongoing debate, with existing evidence largely derived from heterogeneous clinical settings and small individual trials. Therefore, this study aimed to systematically review and meta-analyze randomized controlled trials comparing the analgesic efficacy of ibuprofen versus acetaminophen in pediatric populations with acute mild-to-moderate pain. A systematic literature search was conducted up to May 2026 in PubMed, Scopus, and Web of Science. The review was conducted and reported in accordance with the PRISMA-Children and Adolescents (PRISMA-C) 2026 reporting guideline. Eligible studies were randomized controlled trials comparing ibuprofen with acetaminophen in children and adolescents (defined as individuals aged 0 to&#x2009;<&#x2009;18&#xa0;years) with acute pain, reporting at least one extractable efficacy outcome. Continuous outcomes were synthesized as standardized mean differences (Hedges' g) using random-effects models; dichotomous outcomes were pooled as risk ratios (RRs) with 95% confidence intervals. Risk of bias was assessed using the Cochrane RoB 2 tool and certainty of evidence was evaluated using the GRADE framework. Eight randomized controlled trials enrolling 1325 participants were included. Three pediatric trials contributed to the primary continuous pain outcome meta-analysis (n&#x2009;=&#x2009;196 analyzable participants), yielding a pooled SMD of&#x2009;-&#x2009;0.28 (95% CI&#x2009;-&#x2009;0.57 to 0.00; p&#x2009;=&#x2009;0.052; I2&#x2009;=&#x2009;0%), indicating a small effect favoring ibuprofen that did not reach conventional statistical significance. Given the small number of contributing studies (k&#x2009;=&#x2009;3), the I2 statistic should be interpreted with caution as it has limited power to detect heterogeneity in this context. For the dichotomous pain freedom outcome (2 trials, n&#x2009;=&#x2009;114), no significant difference was observed (pooled RR 1.03, 95% CI 0.53-1.99; p&#x2009;=&#x2009;0.93; I2&#x2009;=&#x2009;0%). A prespecified sensitivity analysis including an adult soft-tissue injury trial attenuated the pooled effect toward the null (SMD&#x2009;-&#x2009;0.15, 95% CI&#x2009;-&#x2009;0.38 to 0.09; p&#x2009;=&#x2009;0.23; I2&#x2009;=&#x2009;36.6%). Narrative synthesis of additional studies generally demonstrated comparable analgesic efficacy between the two agents across postoperative and outpatient pediatric settings. The overall certainty of evidence was rated as low for both primary outcomes, primarily due to imprecision and indirectness. CONCLUSION: Current evidence from randomized controlled trials does not demonstrate a superiority of ibuprofen over acetaminophen for acute mild-to-moderate pain management in children. Both agents appear to provide clinically meaningful analgesia across heterogeneous pediatric pain settings. The clinical choice between agents should be guided by individual patient factors, including contraindications to NSAIDs, the inflammatory nature of the pain etiology, and patient-specific characteristics. The low certainty of evidence underscores the need for adequately powered, methodologically rigorous trials to definitively establish the comparative efficacy of these two analgesics in the pediatric population. WHAT IS KNOWN: &#x2022; Ibuprofen and acetaminophen are the two most widely used non-opioid analgesics for acute mild-to-moderate pain in children, and both are recommended as first-line agents by major international guidelines. &#x2022; Prior meta-analyses in mixed pediatric-adult populations have suggested a modest analgesic advantage of ibuprofen over acetaminophen, but pediatric-specific evidence has remained limited and methodologically heterogeneous. WHAT IS NEW: &#x2022; This systematic review and meta-analysis, restricted to randomized controlled trials in pediatric populations, found that ibuprofen showed a small effect favoring pain reduction compared with acetaminophen (SMD&#x2009;-&#x2009;0.28, p&#x2009;=&#x2009;0.052), although this did not reach conventional statistical significance. &#x2022; The analgesic advantage of ibuprofen may be more pronounced in pain etiologies with a significant inflammatory component (e.g., fractures). At the same time, both agents appear broadly equivalent in most other acute pediatric pain settings, supporting individualized analgesic selection based on clinical context and patient-specific factors.

Humans