Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Photons”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

Photon migration of near-diffusive photons in turbid media: a Lagrangian-based approach.

We show that light transport in a turbid medium can be described by a path integral with a quasi-particle Lagrangian. The most probable trajectory over which photons can be found can be obtained from this Lagrangian. This approach extends the diffusion approximation to the near-diffusive regime, in which photons travel only a few transport mean free paths.

Diffusion↗

Photon counting histogram: one-photon excitation.

The photon counting histogram (PCH) analysis is a fluorescence fluctuation method that is able to characterize the brightness and concentration of different fluorescent species present in a liquid sample. We find that the PCH model using a three-dimensional Gaussian observation volume profile is inadequate for fitting experimental data obtained from a confocal setup with one-photon excitation. We propose an imoroved model, which is based on the correction to the observation volume profile for the out-of-focus emission. We demonstrate that this model is able to resolve different species present under a wide range of conditions. Attention is given to how this model allows the examination of the effects of different instrumental setups on the resolvability.

Journal Article↗

Single photon absorptiometry imaging as a screening method for diminished dual photon density measures.

Scanning of the new 5-mm distal-radius site and the mid-radius (33% site) was performed using single photon absorptiometry (SPA) and of the L2-L4 region of the spine using dual photon absorptiometry (DPA) in a group of healthy women (age range 36-66 yr) in order to develop parameters to enable SPA to be used to screen for low DPA measures. The study data were analyzed as follows: 1. Women were classified as either 'intact' or 'post pelvic surgery' and the data for the two groups were separated. 2. Each SPA measurement was scrutinized and the one which produced the lowest score (% young normal [YN]) was entered for data analysis and graphing. The application of these two analytical discriminators represents a new approach in the biomedical literature. The findings were as follows: 1. When women were separated according to whether they were intact or had undergone pelvic surgery, the threshold value for screening using radius measures among intact women was set at 80% YN. 2. The necessary threshold value for the pelvic-surgery group needed to be set higher, at 93% YN. 3. If either the distal density or the mid-shaft density was below its threshold level, DPA was indicated. 4. At these threshold levels, no women with diminished spinal density (less than 83% YN) were omitted from screening procedure. We conclude that by refining our evaluation of each healthy woman according to her pelvic physiology status (intact or post-surgery) and considering whether either of the two SPA measures is below the threshold value, we will be able to screen for diminished DPA density and thereby eliminate a significant number of expensive but uninformative DPA readings.

Adult↗

Synthesis and photonic band calculations of NCP face-centered cubic photonic crystals of TiO2 hollow spheres.

With the help of self-assembly, thermal sintering, selective etching techniques and sol-gel process, the non-close packed (ncp) face-centered cubic (fcc) photonic crystals of titanium dioxide (TiO2) hollow spheres connected by TiO2 cylindrical tubes have been fabricated using silica template. The photonic bandgap calculations indicate that the ncp structure of TiO2 hollow spheres was easier to open the pseudogaps than close packed system at the lowest energy.

Journal Article↗

Extended photon counting histogram and fluorescence intensity distribution analysis approaches for optically biased photon counting statistics.

A gradient potential induced by a strongly focused laser beam can perturb the diffusion dynamics of particles in solutions and result in biased photon counting statistics in fluorescence fluctuation spectroscopy (FFS). In this paper, the theories of the photon counting histogram (PCH) and fluorescence intensity distribution analysis (FIDA) approaches are extended independently to fit the biased experimental data and retrieve the unbiased parameters, i.e., the average number of the sample particles in the focal volume N, their brightness epsilon, and polarizability alpha. The extended theories are tested using Monte Carlo simulations for single- and double-component systems. It is also proved numerically and analytically that the extended PCH and FIDA approaches are completely equivalent. Practical implementations and possible applications of extended PCH and FIDA are discussed.

Journal Article↗

Photonics: tuning holes in photonic-crystal nanocavities.

One challenge in photonics is strongly to confine light in small volumes in order to increase light-matter interaction. Akahane et al. propose a new concept for increasing the lifetime of this interaction, based on tailoring of the Fourier spectrum of cavity modes, which they believe is demonstrated by the surprising enhancement (roughly tenfold) of the quality factor Q of the cavity as a result of fine-tuning the mirror-hole geometry in a photonic-crystal nanocavity. Here we question the validity of their concept and argue that the improvement in Q is due to an increase in the impedance wave matching at the cavity edges and to a slow-wave effect. This alternative interpretation opens the way to new cavity designs.

Comment↗

Analysis of efficiency of two-photon versus single-photon absorption of fluorescence generation in biological objects.

Starting from basic absorption cross-section values and breakdown limitations on possible field strengths it is shown that the total exposure required for equivalent fluorescence generation by single-photon absorption (SPA) is at least an order of magnitude lower than by two-photon absorption (TPA). The difference is such that TPA may in fact in many cases offer no advantage over SPA with respect to the damage induced during fluorescence imaging of biological materials.

Absorption↗

[Two-photon laser scanning fluorescence microscopy for functional cellular imaging: Advantages and challenges or One photon is good... but two is better!].

One of the main challenges of modern biochemistry and cell biology is to be able to observe molecular dynamics in their functional context, i.e. in live cells in situ. Thus, being able to track ongoing molecular events with maximal spatial and temporal resolution (within subcellular compartments), while minimizing interference with tissue biology, is key to future developments for in situ imaging. The recent use of non-linear optics approaches in tissue microscopy, made possible in large part by the availability of femtosecond pulse lasers, has allowed major advances on this front that would not have been possible with conventional linear microscopy techniques. Of these approaches, the one that has generated most advances to date is two-photon laser scanning fluorescence microscopy. While this approach does not really provide improved resolution over linear microscopy in non absorbing media, it allows us to exploit a window of low absorbance in live tissue in the near infrared range. The end result is much improved tissue penetration, minimizing unwanted excitation outside the focal area, which yields an effective improvement in resolution and sensitivity. The optical system is also simplified and, more importantly, phototoxicity is reduced. These advantages are at the source of the success of two-photon microscopy for functional cellular imaging in situ. Yet, we still face further challenges, reaching the limits of resolution that conventional optics can offer. Here we review some recent advances in optics/photonics approaches that hold promises to improve our ability to probe the tissue in finer areas, at faster speed, and deeper into the tissue. These include super-resolution techniques, introduction of non paraxial optics in microscopy and use of amplified femtosecond lasers, yielding enhanced spatial and temporal resolution as well as tissue penetration.

Cells↗

Stopping-power ratio for a photon spectrum as a weighted sum of the values for monoenergetic photon beams.

Stopping-power ratios for water to air, Sw,air, have been calculated for 60Co and thin-target bremsstrahlung beams. The Monte Carlo method was used to generate depth-dependent Sw,air values and depth-absorbed-dose distributions in water for monoenergetic photon beams covering the energy range 0.1-50 MeV. An averaging procedure has been developed to derive the stopping-power ratios for a photon spectrum from the monoenergetic data. Values of the Spencer-Attix ratio for delta = 10 keV, SSAw,air (delta = 10 keV), and the Bragg-Gray ratio, SBGw,air, evaluated using the new I values and two different sets of values for the density effect correction, are given at the reference depths recommended in the dosimetry protocols.

Humans↗

Etched distributed Bragg reflectors as three-dimensional photonic crystals: photonic bands and density of states.

The photonic band dispersion and density of states (DOS) are calculated for the three-dimensional (3D) hexagonal structure corresponding to a distributed Bragg reflector patterned with a 2D triangular lattice of circular holes. Results for the Si/SiO(2) and GaAs/Al(x)Ga(1-x)As systems determine the optimal parameters for which a gap in the 2D plane occurs and overlaps the 1D gap of the multilayer. The DOS is considerably reduced in correspondence with the overlap of 2D and 1D gaps. Also, the local density of states (i.e., the DOS weighted with the squared electric field at a given point) has strong variations depending on the position. Both results imply substantial changes of spontaneous emission rates and patterns for a local emitter embedded in the structure and make this system attractive for the fabrication of a 3D photonic crystal with controlled radiative properties.

Journal Article↗

Direct measurement of the photon statistics of a triggered single photon source.

We studied intensity fluctuations of a single photon source relying on the pulsed excitation of the fluorescence of a single molecule at room temperature. We directly measured the Mandel parameter Q(T) over 4 orders of magnitude of observation time scale T by recording every photocount. On time scale of a few excitation periods, sub-Poissonian statistics is clearly observed and the probablility of two-photons events is 10 times smaller than Poissonian pulses. On longer times, blinking in the fluorescence, due to the molecular triplet state, produces an excess of noise.

Journal Article↗

Experimental reconstruction of photon statistics without photon counting.

Experimental reconstructions of photon number distributions of both continuous-wave and pulsed light beams are reported. Our scheme is based on on/off avalanche photo-detection assisted by maximum-likelihood estimation and does not involve photon counting. Reconstructions of the distribution for both semiclassical and quantum states of light are reported for single-mode as well as for multi-mode beams.

Journal Article↗

Femtosecond laser-induced two-photon polymerization of inorganic-organic hybrid materials for applications in photonics.

Investigations of two-photon polymerization of inorganic-organic hybrid materials initiated by femtosecond Ti:sapphire laser pulses are performed. First applications of this technique for the fabrication of three-dimensional microstructures and photonic crystals in inorganic-organic hybrid polymers with a structure size down to 200 nm and a periodicity of 450 nm are discussed.

Journal Article↗

Narrow frequency and sharp angular defect mode in one-dimensional photonic crystals from a photonic heterostructure.

By combining two one-dimensional defective photonic crystals (PCs), we obtained a photonic heterostructure with narrow frequency and a sharp angular defect mode. The key to obtaining such a structure is to design the two sub-PCs to make the frequencies of their defect modes the same at one incident angle and different at all other incident angles. Filters designed on the basis of this heterostructure possess not only a narrow-frequency passband but also a sharp angular pass breadth. Optimization of the practical design is also suggested.

Journal Article↗

Improved air-silica photonic crystal with a triangular airhole arrangement for hollow-core photonic bandgap fiber design.

We propose an improved photonic crystal (PC) cladding design for existing air-guiding photonic bandgap (PBG) fibers whose cladding airholes are arranged in a triangular lattice pattern. By increasing the sizes of concentrated silica regions in the cladding PC, we can have a larger degree of freedom in controlling the cladding bandgap regions. We predict that a fiber made from this type of cladding would perform better in terms of the PBG-guiding wavelength range, radiation loss owing to finite cladding size, and the ability to avoid surface mode problems.

Journal Article↗

1.5 microm photon-counting optical time-domain reflectometry with a single-photon detector based on upconversion in a periodically poled lithium niobate waveguide.

Optical time-domain reflectometry (OTDR) is one of the most powerful tools in the characterization of optical fiber links. We demonstrate a photon-counting OTDR system at 1.5 microm with a single-photon detector, which combines frequency upconversion in a periodically poled lithium niobate waveguide and a silicon avalanche photodiode. The system exhibits high sensitivity, good spatial resolution, and short measurement time.

Journal Article↗

Limitations arising from two-photon absorption of solvent in pulsed-laser thermal lens detection: determination of the two-photon absorption coefficient of ethanol at 266 nm.

Two-photon absorption of the solvent under pulsed-laser excitation at 266 nm produces a high background thermal lens signal interfering with the analyte signal. Discrimination of both solvent and analyte signals along with calibration of the photothermal response has allowed the determination of the two-photon absorption coefficient of ethanol. The obtained value, 3.0x10(-10) cm W-1, is close to the literature values obtained from transmittance measurements using picosecond or femtosecond laser pulses.

Absorption↗