Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MR”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

Endorectal MR imaging and MR spectroscopic imaging for locally recurrent prostate cancer after external beam radiation therapy: preliminary experience.

PURPOSE: To evaluate endorectal magnetic resonance (MR) imaging and MR spectroscopic imaging for the depiction of locally recurrent prostate cancer after external beam radiation therapy. MATERIALS AND METHODS: Endorectal MR imaging and MR spectroscopic imaging were performed in 21 patients with biochemical failure after external beam radiation therapy for prostate cancer. Two readers independently and retrospectively reviewed MR images and rated the likelihood of recurrent tumor on a five-point scale. Spectroscopic voxels were considered suspicious for malignancy if the choline level was elevated and citrate was absent. Receiver operating characteristic curve analysis was used to assess cancer detection in each side of the prostate with endorectal MR imaging and spectroscopic imaging at different thresholds based on the scores assigned by the two readers and on the number of suspicious voxels in each hemiprostate, respectively. The presence or absence of cancer at subsequent transrectal biopsy was used as the standard of reference. RESULTS: Biopsy demonstrated locally recurrent prostate cancer in nine hemiprostates in six patients. The area under the receiver operating characteristic curve for the detection of locally recurrent cancer with MR imaging was 0.49 and 0.51 for readers 1 and 2, respectively. By using the number of suspicious voxels to define different diagnostic thresholds, the area under the receiver operating characteristic curve for MR spectroscopic imaging was significantly (P < .005) higher, at 0.81. In particular, the presence of three or more suspicious voxels in a hemiprostate showed a sensitivity and specificity of 89% and 82%, respectively, for the diagnosis of local recurrence. Seven hemiprostates demonstrated complete metabolic atrophy at spectroscopic imaging and only postirradiation atrophy at biopsy. CONCLUSION: Preliminary data suggest that MR spectroscopic imaging, but not endorectal MR imaging, may be of value for the depiction of locally recurrent prostate cancer after radiation therapy.

Aged↗

Defining intrahepatic biliary anatomy in living liver transplant donor candidates at mangafodipir trisodium-enhanced MR cholangiography versus conventional T2-weighted MR cholangiography.

PURPOSE: To compare three-dimensional (3D) mangafodipir trisodium-enhanced T1-weighted magnetic resonance (MR) cholangiography with conventional T2-weighted MR cholangiography for depiction and definition of intrahepatic biliary anatomy in liver transplant donor candidates. MATERIALS AND METHODS: One hundred eight healthy liver transplant donor candidates were examined with two MR cholangiographic methods. All candidates gave written informed consent, and the study was approved by the institutional review board. First, breath-hold transverse and coronal half-Fourier single-shot turbo spin-echo and breath-hold oblique coronal heavily T2-weighted turbo spin-echo sequences were performed. Second, mangafodipir trisodium-enhanced breath-hold fat-suppressed 3D gradient-echo sequences were performed through the ducts (oblique coronal plane) and through the entire liver (transverse plane). Interpretation of biliary anatomy findings, particularly variants affecting right liver lobe biliary drainage, and degree of interpretation confidence at both 3D mangafodipir trisodium-enhanced MR cholangiography and T2-weighted MR cholangiography were recorded and compared by using the Wilcoxon signed rank test. Then, consensus interpretations of both MR image sets together were performed. Intraoperative cholangiography was the reference-standard examination for 51 subjects who underwent right lobe hepatectomy. The McNemar test was used to compare the accuracies of the individual MR techniques with that of the consensus interpretation of both image sets together and to compare each technique with intraoperative cholangiography. RESULTS: Biliary anatomy was visualized with mangafodipir trisodium enhancement in all patients. Mangafodipir trisodium-enhanced image findings agreed with findings seen at combined interpretations significantly more often than did T2-weighted image findings (in 107 [99%] vs 88 [82%] of 108 donor candidates, P < .001). Confidence was significantly higher with the mangafodipir trisodium-enhanced images than with the T2-weighted images (mean confidence score, 4.5 vs 3.4; P < .001). In the 51 candidates who underwent intraoperative cholangiography, mangafodipir trisodium-enhanced imaging correctly depicted the biliary anatomy more often than did T2-weighted imaging (in 47 [92%] vs 43 [84%] donor candidates, P = .14), whereas the two MR imaging techniques combined correctly depicted the anatomy in 48 (94%) candidates. CONCLUSION: Mangafodipir trisodium-enhanced 3D MR cholangiography depicts intrahepatic biliary anatomy, especially right duct variants, more accurately than does conventional T2-weighted MR cholangiography.

Adolescent↗

MR imaging in patients with Crohn disease: value of T2- versus T1-weighted gadolinium-enhanced MR sequences with use of an oral superparamagnetic contrast agent.

PURPOSE: To prospectively compare oral contrast-enhanced T2-weighted half-Fourier rapid acquisition with relaxation enhancement (RARE) magnetic resonance (MR) imaging with T1-weighted gadolinium-enhanced fast low-angle shot (FLASH) MR and standard examinations in the evaluation of Crohn disease. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. Fifty-nine patients with Crohn disease underwent MR imaging after oral administration of a superparamagnetic contrast agent; RARE plain and fat-suppressed sequences and FLASH sequences were performed before and after intravenous injection of gadolinium chelate. References were endoscopic, small-bowel barium, computed tomographic, ultrasonographic, and clinical-biochemical scoring of disease activity. Two radiologists analyzed MR images for presence and extent of Crohn disease lesions, presence of strictures or other complications, and degree of local inflammation. MR findings were correlated with endoscopic, radiologic, and clinical data (kappa statistic and Spearman rank correlation test). RESULTS: T2-weighted MR was 95% accurate, 98% sensitive, and 78% specific for detection of ileal lesions. Agreement between T1- and T2-weighted images ranged from 0.77 for ileal lesions to 1.00 for colic lesions. T2-weighted MR enabled detection of 26 of 29 severe strictures, 17 of 24 enteroenteric fistulas, and all adhesions and abscesses; T1-weighted MR enabled detection of 20 of 29 severe strictures, 16 of 24 enteroenteric fistulas, and all adhesions and abscesses. Complications leading to surgery were found in 12 (20%) patients; these were assessed correctly with either T1- or T2-weighted images. T2-weighted signal intensities of the wall and mesentery correlated with biologic activity (P < .001, r of 0.774 and 0.712, respectively). Interobserver agreement was 0.642-1.00 for T2-weighted and 0.711-1.00 for T1-weighted images. CONCLUSION: T2-weighted MR can depict Crohn disease lesions and help assess mural and transmural inflammation with the same accuracy as gadolinium-enhanced T1-weighted MR. Combination of gadolinium-enhanced T1- and T2-weighted sequences is useful in the assessment of Crohn disease.

Adolescent↗

Determination of left ventricular volume and mass with use of biphasic spin-echo MR imaging: comparison with cine MR.

In this study, the authors compared a new rapid spin-echo magnetic resonance (MR) imaging method, biphasic MR, with cine MR in the determination of left ventricular volume and mass in healthy volunteers. Biphasic spin-echo MR images covering the entire heart were obtained with use of the electrocardiogram R wave and the downslope of the T wave at both end diastole and end systole, respectively. Biphasic MR-determined values correlated well with small standard errors of the estimate (end-diastolic volume = 7.82 cm3, end-diastolic mass = 10.20 g, end-systolic mass = 10.08 g, ejection fraction = 2.62%) and were more reproducible. Cine MR-defined end-systolic volume was significantly larger (P less than .01) and ejection fraction was significantly smaller (P less than .005) than biphasic MR-determined values probably because of the uncertainty in isolating end systole with cine MR. Left ventricular volumes, mass, and ejection fraction are more accurately and reproducibly quantified in a more time-efficient manner with use of biphasic MR than with cine MR because of its significantly shorter image acquisition and reconstruction times.

Adult↗

Carotid and vertebral artery dissections: three-dimensional time-of-flight MR angiography and MR imaging versus conventional angiography.

PURPOSE: To compare three-dimensional time-of-flight magnetic resonance (MR) angiography, MR imaging, and transfemoral four-vessel angiography in diagnosis and follow-up of cervical artery dissection. MATERIALS AND METHODS: Eighteen patients with 19 extracranial internal carotid artery and five vertebral artery dissections were included in this prospective study. Blind interpretation of MR and angiographic images was made by two independent radiologists. RESULTS: MR angiography was more accurate than MR imaging in diagnosis of carotid dissection, although the difference was not statistically significant. In carotid artery dissection, respective sensitivity and specificity were 95% and 99% for MR angiography and 84% and 99% for MR imaging and in vertebral artery dissection were 20% and 100% for MR angiography and 60% and 98% for MR imaging. CONCLUSION: MR angiography is a reliable, noninvasive method for use in diagnosis and follow-up of extracranial internal carotid artery dissection. In vertebral artery dissection, however, conventional angiography remains useful.

Adult↗

Phenylketonuria: findings at MR imaging and localized in vivo H-1 MR spectroscopy of the brain in patients with early treatment.

PURPOSE: To characterize white matter changes in early-treated phenylketonuria (PKU) with magnetic resonance (MR) imaging and hydrogen-1 MR spectroscopy and to correlate these findings to biochemical control and brain function. MATERIALS AND METHODS: Fifty-one patients aged 12-33 years underwent T1-, T2-, and proton-density-weighted MR imaging and testing of intelligence, visual evoked potentials (VEPs), and neuropsychologic status (29 adult patients only). H-1 MR spectroscopy was performed in eight patients to determine brain metabolite concentrations, including phenylalanine (PHE) concentration, and brain compartmentation. RESULTS: MR imaging revealed a high frequency of supra- and infratentorial abnormalities. MR imaging grade, which was based on areas of high signal intensity on T2-weighted images, showed statistically significant correlation with long-term biochemical control and neuropsychologic test results but not with intelligence quotient or VEPs. H-1 MR spectroscopy revealed normal metabolite levels, except for increased PHE levels. It also showed enlarged cerebrospinal fluid-like compartments in affected white matter, related to plasma and brain concentrations of PHE and MR imaging grades. CONCLUSION: A synergistic use of MR imaging and MR spectroscopy may help elucidate both the pathogenesis of brain dysfunction and clinical treatment policies in PKU.

Adolescent↗

Thoracic aorta: comparison of gadolinium-enhanced three-dimensional MR angiography with conventional MR imaging.

PURPOSE: To evaluate gadolinium-enhanced three-dimensional magnetic resonance (MR) angiography for thoracic aortic disease and to compare this technique with conventional thoracic MR imaging. MATERIALS AND METHODS: One hundred eight consecutive patients underwent 122 thoracic MR examinations, including conventional MR imaging followed by enhanced three-dimensional MR angiography. A gradient-echo sequence was used at 1.5 T (116 examinations) and 1.0 T (6 examinations) during infusion of 0.2 mmol/kg gadopentetate dimeglumine. Two independent readers (A and B), with varied experience in thoracic MR angiography, retrospectively evaluated the images for presence of aortic dissection, aneurysm, arch vessel disease, and protruding atheroma. Correlation with findings of surgery or other imaging modalities was available in 98 cases. RESULTS: Enhanced MR angiography was sensitive (92%-96%) and specific (100%) for acute and chronic aortic dissection (n = 26) and was as useful as conventional MR imaging in the diagnosis of aneurysm (n = 43) and arch vessel disease (n = 7). One of two intramural hematomas were overlooked at MR angiography by reader A, and both were overlooked by reader B. CONCLUSION: Enhanced three-dimensional MR angiography is a rapid and accurate imaging modality in diagnosis of thoracic aortic disease but is insensitive to intramural hematoma.

Adolescent↗

Contrast-enhanced 3D MR DSA of the carotid artery bifurcation: preliminary study of comparison with unenhanced 2D and 3D time-of-flight MR angiography.

PURPOSE: To compare the delineation of stenosis at the carotid artery bifurcation on three-dimensional (3D) magnetic resonance (MR) digital subtraction angiographic (DSA) images with that on two-dimensional (2D) and 3D time-of-flight (TOF) MR angiographic images. MATERIALS AND METHODS: Twenty-six patients with 29 carotid artery bifurcations and symptoms of cerebral ischemia underwent 3D MR DSA. A time-resolved series was generated with 3D MR DSA after the bolus injection of gadodiamide. The resolution for a carotid artery examination was 0.4 x 0.4 x 1.0 mm, with volumes reconstructed at 4.5-second intervals. The 3D MR DSA images were compared with contemporaneously acquired unenhanced 2D and 3D TOF images. Two observers ranked the 2D and 3D TOF MR angiographic and 3D MR DSA images according to the following: (a) stenosis delineation, (b) internal carotid artery delineation, (c) intravascular signal intensity, and (d) diagnostic confidence. RESULTS: The mean ranking for diagnostic confidence was 1.10 (1 = best technique, 3 = worst technique) for 3D MR DSA. Compared with the pooled 2D TOF and 3D TOF ranks, the 3D MR DSA rank was significantly better (P < .01). Similar levels of statistical significance were found for the other criteria. CONCLUSION: Three-dimensional MR DSA improves the delineation of carotid arterial stenosis by virtually eliminating saturation effects and reducing intravoxel dephasing. Surface morphology and nearly occluded vessels ("string sign") were easily identified. Confidence in identifying carotid arterial occlusions was also very high with this technique.

Angiography, Digital Subtraction↗

Vascular and extravascular complications of liver transplantation: comprehensive evaluation with three-dimensional contrast-enhanced volumetric MR imaging and MR cholangiopancreatography.

OBJECTIVE: Our purpose was to evaluate a comprehensive MR imaging strategy for recipients of liver transplants that relies on dynamic interpolated three-dimensional (3D) MR imaging for simultaneous vascular, parenchymal, and extrahepatic imaging. MATERIALS AND METHODS: Twenty-three consecutive adult patients underwent 30 MR imaging examinations between 2 days and 99 months (mean, 15 months) after transplantation using a breath-hold 3D gradient-echo sequence (TR range/TE range, 3.7-4.7/1.8-1.9; flip angle, 12-30 degrees ) with an intermittent fat-saturation pulse and interpolation in the section-select direction to enable pixel size 3 mm or less in all dimensions. Unenhanced and triphasic contrast-enhanced 3D imaging (average dose, 0.13 mmol/kg of gadopentetate dimeglumine) was performed. A subset of patients (n = 13) also underwent MR cholangiopancreatography using half-Fourier single-shot turbo spin-echo imaging. MR imaging examinations were correlated with digital subtraction angiography (n = 8), contrast-enhanced cholangiography (n = 9), sonography (n = 13), and histopathology (n = 14). RESULTS: MR imaging revealed abnormal findings in 27 (90%) of 30 examinations, including vascular disease in nine, biliary complications in four, and evidence of intra- or extra-hepatic hepatocellular carcinoma recurrence in six. Digital subtraction angiography confirmed seven MR angiography examinations but suggested disease overestimation in one. Contrast-enhanced cholangiography confirmed findings of MR cholangiopancreatography in seven cases but suggested disease underestimation in two. CONCLUSION: Dynamic interpolated 3D MR imaging combined with dedicated MR cholangiopancreatography can provide a comprehensive assessment of vascular, biliary, parenchymal, and extrahepatic complications in most recipients of liver transplants.

Adult↗

MR imaging, MR arthrography, and specimen correlation of the posterolateral corner of the knee: an anatomic study.

OBJECTIVE: We sought to evaluate the anatomy of the posterolateral aspect of the knee with anatomic dissection, MR imaging, MR arthrography, and sectional anatomy. MATERIALS AND METHODS: We assessed the posterolateral corner of the knee during dissection of one gross anatomic specimen. MR imaging and MR arthrography were performed in seven additional knee specimens. T1-weighted spin-echo MR images were obtained in the standard imaging planes as well as in the coronal oblique plane. The specimens underwent T1-weighted spin-echo MR imaging after administration of intraarticular contrast material and were sectioned into planes corresponding to those of the MR images. RESULTS: At anatomic dissection, the following posterolateral structures were identified: the arcuate ligament (medial and lateral limbs), fabellofibular ligament, popliteofibular ligament, popliteus tendon and its two posterior attachments to the lateral meniscus, fibular collateral ligament, direct and anterior arms of the tendon of the long head of the biceps femoris muscle, and direct and anterior arms of the tendon of the short head of the biceps femoris muscle. Correlation of MR imaging and anatomic findings showed that the popliteofibular ligament and oblique popliteal ligament were found in 57% and 100% of specimens, respectively. At least one of the two limbs of the arcuate ligament was identified in 71% of specimens. The fabellofibular ligament was not identified on MR images in any of the specimens. The anteroinferior and posterosuperior popliteomeniscal fascicles were identified in all specimens. CONCLUSION: The posterolateral corner of the knee comprises complex and variable anatomic structures. Recognition of these variations is important in the assessment of MR images of the knee.

Arthrography↗

MR imaging and proton MR spectroscopic studies in Sjögren-Larsson syndrome: characterization of the leukoencephalopathy.

BACKGROUND AND PURPOSE: Sjögren-Larsson syndrome (SLS) is a neurocutaneous syndrome caused by a genetic enzyme deficiency in lipid metabolism. Our purpose was to characterize the nature of the cerebral involvement in SLS. METHODS: MR imaging was performed in 18 patients (aged 5 months to 45 years) and repeated in 14. Single-voxel proton MR spectra were acquired from cerebral white matter and gray matter in 16 patients, with follow-up studies in 11. LCModel fits were used to determine brain metabolite levels. RESULTS: MR imaging showed retardation of myelination and a mild persistent myelin deficit. A zone of increased signal intensity was seen in the periventricular white matter on T2-weighted images. Proton MR spectroscopy of white matter revealed a prominent peak at 1.3 ppm, normal levels of N-acetylaspartate, and elevated levels of creatine (+14%), choline (+18%), and myo-inositol (+54%). MR imaging and proton MR spectroscopy of gray matter were normal. In the two patients examined during the first years of life, abnormalities on MR imaging and proton MR spectroscopy gradually emerged and then stabilized, as in all other patients. CONCLUSION: Abnormalities on MR imaging and proton MR spectroscopy emerge during the first years of life and are similar in all patients with SLS, but the severity varies. The changes are confined to cerebral white matter and suggest an accumulation of lipids, periventricular gliosis, delayed myelination, and a mild permanent myelin deficit.

Adolescent↗

Dopamine D2 receptor binding subunits of Mr congruent to 140,000 and 94,000 in brain: deglycosylation yields a common unit of Mr congruent to 44,000.

The ligand-binding subunit of the porcine striatal dopamine D2 receptor was identified by photoaffinity labeling with [125I]N-azidophenethylspiperone ([125I]NAPS). Upon photolysis, [125I]NAPS covalently incorporated into a broad band of apparent Mr congruent 140,000 with an appropriate pharmacological profile for D2 receptors as assessed by autoradiography after sodium dodecyl sulfate-polyacrylamide gel electrophoresis. Smaller subunits of apparent Mr congruent 94,000 and 34,000 were specifically labeled by [125I]NAPS with an appropriate D2 receptor profile and were similar to the major ligand-binding subunits of photoaffinity-labeled canine striatal D2 receptors. Photoaffinity labeling in the absence or presence of multiple protease inhibitors did not alter the migration pattern of the Mr congruent to 140,000/94,000 subunits upon denaturing electrophoresis in either the absence or presence of thiol-reducing/alkylating reagents. In order to investigate the possible basis for the existence of these high molecular weight forms of the D2 receptor, we assessed the carbohydrate nature of photolabeled D2 ligand-binding subunits by the use of lectin affinity chromatography and specific exo- and endoglycosidase treatments. Both photoaffinity-labeled D2 receptor proteins from porcine striatum (Mr congruent to 140,000 and 94,000) were glycoproteins as indexed by their absorption and specific elution from wheat germ agglutinin lectin resins. The exoglycosidase neuraminidase altered the electrophoretic mobility of both the Mr congruent to 140,000 and 94,000 labeled subunits to a single band of apparent Mr congruent to 51,000. Prior removal of sialic acid residues did not alter the reversible binding characteristics of [3H]spiperone to D2 receptors. Complete removal of receptor-associated N-linked carbohydrate by the endoglycosidase glycopeptidase F (peptide-N4[N-acetyl-beta-glucosaminyl]asparagine amidase) produced a further increase in the mobility of the Mr congruent to 51,000 subunit to apparent Mr congruent to 44,000. The porcine Mr congruent to 34,000 photolabeled peptide is an N-linked glycoprotein as assessed by lectin affinity chromatography and susceptibility to digestion by glycopeptidase F to a peptide of apparent Mr congruent to 23,000.(ABSTRACT TRUNCATED AT 400 WORDS)

Affinity Labels↗

Basilar and distal vertebral artery occlusive disease: correlation of MR imaging and MR angiography.

The purpose of this study is to evaluate the correlation of brain lesions seen on magnetic resonance imaging with vascular occlusive disease of the basilar and distal vertebral arteries as documented on MR angiography. The clinical findings are also correlated with the findings on MR imaging and MR angiography. The clinical records of twenty-one patients with proven occlusive disease of the distal vertebral and/or basilar arteries were retrospectively reviewed. All the patients were imaged utilizing either the Siemens Magnetom 1.5 T SP 4000 and the Siemens 1.0 T Impact systems. Dual MR angiographic techniques were employed including two-dimensional (2D) and three-dimensional time-of-flight. The 2D sequences utilized fast low angle shot gradient echo sequences. The 3D sequences utilized fast image steady-state precession gradient echo sequences. Gadolinium contrast was utilized for increased angiographic detail in one patient. Magnetization transfer contrast was used in three patients. The individual partitions as well as the maximum intensity pixel projection images were evaluated in each case. The most extensive brain lesions were seen in the group of patients with severe basilar and/or combined vertebrobasilar disease. One-half of these patients showed non-specific scattered foci of T2 lengthening similar to the findings found in a group of patients with noncritical stenosis. MR imaging invariably demonstrated more lesions than were clinically suspected. Even though the brain lesions tended to be more extensive in patients with severe vascular disease, the amount of brain tissue damage was not an adequate parameter to document the degree of vascular narrowing. The degree of vascular narrowing was useful in therapy planning. Such data was obtained by the MR angiograms, but not by MR imaging. MR angiography is a useful complementary examination when lesions in the basilar and distal vertebral vascular territories are diagnosed on MR imaging. MR angiography can differentiate critical from noncritical stenosis and can thus play a key role in the therapeutic decision making process.

Adult↗

MR angiography with three-dimensional MR digital subtraction angiography.

We have developed a time-resolved, contrast-enhanced, volume-imaging technique for magnetic resonance (MR) angiography, known as three-dimensional (3D) MR digital subtraction angiography (DSA). This technique greatly improves MR angiogram quality because it combines the injection of a contrast agent with the ability to image the temporal passage of this agent and, thereby, obviates the need for timing scans or other complicated synchronization schemes. Three-dimensional MR DSA also represents a potential improvement in the sense that, relative to DSA and computed tomography (CT) angiography, the contrast agent is less toxic. Additionally, unlike CT angiography, images may be acquired during the passage of the contrast agent. Therefore, 3D MR DSA shows the sequential passage of contrast through the arterial and venous system, followed by uptake in various organs. Unlike conventional DSA, 3D MR DSA imaging acquires full volume datasets, which allows subsequent reprojection and reformatting. Because images are obtained at approximately 2-6 s time intervals using a temporal aperture on the order of several seconds, motion (such as respiration) causes only a temporary disruption of image quality, similar to that observed in MR fluoroscopy. These temporal characteristics also make the proposed sequence insensitive to variations in the shape and timing of the contrast-pass curve. Although the individual time-resolved images will have somewhat decreased signal-to-noise ratio (SNR) relative to nontime-resolved scans collected in the same acquisition time, the SNR improvement due to the gadolinium appears to accommodate this trade-off. Additionally, if motion between successive images is small, then the full suite of temporal processing schemes, previously investigated in connection with DSA and time-resolved two-dimensional (2D) MR, such as mask mode subtraction, simple matched filtering and Eigen filtering, can be used to obtain composite images. These derived images generally have an increased SNR or negligible venous signal if an arterial-phase image is not obtained in the early time-resolved images. In summary, 3D MR DSA will significantly advance MR angiography because of the following intrinsic advantages: (1) improved signal-to-noise, (2) scan orientation may be chosen independently of the direction of blood flow, (3) uniform vascular signal, even from regions of complex flow, (4) minimization of motion artifacts, (5) greatly reduced sensitivity to variation in the shape and timing of the contrast bolus, (6) ability to be reformatted or reprojected, and (7) ability to apply a variety of temporal postprocessing techniques.

Angiography, Digital Subtraction↗

MR of hypoxic encephalopathy in children after near drowning: correlation with quantitative proton MR spectroscopy and clinical outcome.

BACKGROUND AND PURPOSE: Quantitative MR spectroscopy has a proved role in the investigation of hypoxia caused by near drowning. To date, no studies have addressed the MR imaging changes that may also accompany this condition. The purpose of this study was to describe the MR imaging findings in children with hypoxic encephalopathy caused by near drowning and to compare these findings with the results of qualitative and quantitative proton MR spectroscopy and clinical outcome. METHODS: Twenty-two children (6 months to 11 years old) admitted to the pediatric intensive care unit after near drowning incidents underwent cerebral MR imaging and quantitative proton MR spectroscopy. Clinical and imaging studies were reviewed retrospectively, and subjects were grouped according to outcome: good result, persistent vegetative state, and death. Images were scored for edema, basal ganglia changes, and cortical changes, and were compared with MR spectra and outcome at days 1 to 2, 3 to 4, and 5 or more. RESULTS: Six patients had a good outcome, four remained in a persistent vegetative state, and 12 died. Generalized/occipital edema correlated with poor outcome. Indistinct lentiform nuclei margins on T1-weighted images were a frequent finding (78%). Basal ganglia T2 hyperintensity correlated with poor outcome, progressing from a patchy/peripheral distribution to diffuse high intensity. Patchy high T2 signal in the cortex or subcortical lines were specific but insensitive for poor outcome, as were brain stem infarcts. CONCLUSION: MR images in children with hypoxic encephalopathy after near drowning show a spectrum of changes. The most sensitive prognostic result may be achieved by combining MR imaging with qualitative and quantitative MR spectroscopic data.

Brain Diseases↗

MR imaging of perinatal brain damage: comparison of clinical outcome with initial and follow-up MR findings.

BACKGROUND AND PURPOSE: The purpose of our study was to determine whether MR studies in the neonatal period are predictive of the neuroradiologic sequelae and clinical outcome in premature and term infants with perinatal brain injury. METHODS: Thirty subjects (15 premature and 15 term infants) with abnormalities revealed by initial MR studies were reexamined approximately 1 year after birth with both MR imaging and a neurologic assessment. All initial MR studies were performed between 35 and 45 weeks corrected age in premature infants and within 28 days of life in term infants. The initial MR studies were evaluated for deep gray matter involvement, hemispheric parenchymal change, intracranial hemorrhage, and periventricular signal and/or morphologic changes. These MR findings were compared with the follow-up MR findings and with the neurologic outcome. RESULTS: The development of cerebral palsy in premature infants was related to the following initial MR findings: subependymal hemorrhage associated with parenchymal destruction, periventricular signal alteration with irregularity of the ventricular wall, and widespread cerebral infarction. These MR findings were predictive of the subtypes of cerebral palsy. In term asphyxiated infants, T2 signal alterations of the deep gray matter rather than T1 shortening and diffuse involvement of the hemispheres were predictive of an unfavorable outcome. Both in term and premature infants, focal hemispheric parenchymal lesions alone (including infarction and intracerebral, subdural, intraventricular, and subarachnoid hemorrhage) did not produce poor outcomes. CONCLUSION: MR studies performed at or near term in either premature or term infants with perinatal brain damage are effective in predicting both late neuroradiologic and clinical outcome.

Asphyxia Neonatorum↗

Evaluation of the rotator cuff and glenoid labrum using a 0.2-Tesla extremity magnetic resonance (MR) system: MR results compared to surgical findings.

The purpose of this investigation was to evaluate the diagnostic capabilities of magnetic resonance imaging (MRI) performed using a dedicated-extremity MR system in detecting lesions of the rotator cuff and glenoid labrum. This retrospective study compared the MR results obtained in 47 patients that underwent MRI using a 0.2-Tesla extremity MR system (E-scan) to the surgical findings. MR images of the shoulder were obtained as follows: shoulder coil, T1-weighted, coronal-oblique and axial images; short Tau inversion recovery (STIR), coronal-oblique images; and T2-weighted, coronal-oblique, sagittal-oblique, and axial images. The MR examinations were interpreted by three highly experienced, musculoskeletal radiologists. Open surgical (N = 26) or arthroscopic (N = 21) procedures were performed within a mean time of 33 days after MRI. The surgical findings revealed rotator cuff tears in 28 patients and labral lesions in 9 patients. For the rotator cuff tears, the sensitivity, specificity, positive predictive value, and negative predictive value were 89%, 100%, 100%, and 90%, respectively. For the labral lesions, the sensitivity, specificity, positive predictive value, and negative predictive value were 89%, 95%, 80%, and 97%, respectively. The findings indicated that there was good agreement comparing the MR results obtained using the low-field extremity MR system to the surgical findings for determination of lesions of the rotator cuff and glenoid labrum. Notably, the statistical values determined for the use of this MR system were comparable to those reported in the peer-reviewed literature for the use of whole-body, mid- and high-field-strength MR systems.

Adolescent↗

Assessment of the rotator cuff and glenoid labrum using an extremity MR system: MR results compared to surgical findings from a multi-center study.

PURPOSE: To conduct a multi-center assessment of the use of a 0.2-T, extremity MR system (E-scan; General Electric Lunar Corp. and Esaote, Genoa, Italy) for identifying tears of the rotator cuff and glenoid labrum. MATERIALS AND METHODS: A retrospective study was performed involving 160 patients (age range, 15-84 years old) from five facilities in the United States, comparing shoulder MR imaging to surgical findings. MR imaging of the shoulder was conducted as follows: shoulder coil; T1-weighted spin echo, coronal-oblique and axial images; short Tau inversion recovery (STIR), coronal-oblique images and axial images; and T2-weighted spin echo, coronal-oblique and sagittal-oblique images. The MR examinations were interpreted in an independent, prospective manner by two radiologists with extensive musculoskeletal MRI experience. Arthroscopic (N = 103) or open surgical (N = 57) procedures were performed within a mean of 53 days after MR imaging. RESULTS: Surgical findings demonstrated rotator cuff tears in 131 patients and labral tears in 60 patients. For the rotator cuff, the sensitivity, specificity, positive predictive value, and negative predictive value were 90%, 93%, 98%, and 68%, respectively. For the labrum, the sensitivity, specificity, positive predictive value, and negative predictive value were 55%, 100%, 100%, and 82%, respectively. CONCLUSIONS: There was good agreement when MR results obtained using the extremity MR system were compared to surgical findings for identifying rotator cuff tears, while the sensitivity of MR imaging for determining labral tears was relatively poor. Nevertheless, these findings were comparable to those reported in the peer-reviewed literature for MR systems operating at mid-, and high-field-strengths.

Adolescent↗