Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Liquid-Liquid Extraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

Simultaneous determination of chlorpheniramine and pseudoephedrine in human plasma by liquid chromatography-tandem mass spectrometry.

A sensitive and specific procedure for simultaneous quantitation of chlorpheniramine and pseudoephedrine in human plasma has been developed and validated. Analytes were extracted from plasma samples by liquid-liquid extraction, separated on a Diamonsil C18 column (250 x 4.6 mm i.d.) and detected by tandem mass spectrometry with an atmospheric pressure chemical ionization interface. Diphenhydramine was used as the internal standard. The method has a lower limit of quantitation of 0.2 and 2.0 ng/mL for chlorpheniramine and pseudoephedrine, respectively. The intra- and inter-day relative standard deviation, calculated from quality control (QC) samples were below 4.3% for chlorpheniramine and below 9.5% for pseudoephedrine. The inter-day relative error as determined from QC samples was within 4.7% for each analyte. The overall extraction recoveries of chlorpheniramine and pseudoephedrine were 77 and 61% on average, respectively. The method was successfully applied to pharmaockinetic study of chlorpheniramine and pseudoephedrine in volunteers receiving formulations containing 4 mg of chlorpheniramine maleate and 60 mg of pseudoephedrine hydrochloride.

Anti-Allergic Agents↗

Determination of bisphenol A in human breast milk by HPLC with column-switching and fluorescence detection.

A highly sensitive HPLC method was developed for the determination of xenoestrogenic compound, bisphenol A (BPA) in human breast milk samples. After a two-step liquid-liquid extraction, BPA was derivatized with fluorescent labeling reagent, 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl). The excess fluorescent reagent could be removed effectively using a column-switching system. The separation of DIB-BPA from endogenous materials in milk was carried out on two C(18) columns and fluorescence intensity was monitored at 475 nm with the excitation of 350 nm. A good linearity (r = 0.994) was observed of BPA in the concentration range of 0.2-5.0 ng mL(-1) in breast milk, and the detection limit was 0.11 ng mL(-1) at a signal-to-noise ratio of 3. Intra- and inter-day precision (RSD, %) were less than 8.7 and 10.4, respectively. Twenty-three breast milk samples of healthy lactating women were analyzed for the BPA concentration; the mean value was 0.61 +/- 0.20 ng mL(-1), with no correlation to the lipid content of milk samples.

Benzhydryl Compounds↗

An isocratic HPLC method for the quantitation of eicosanoids in human platelets.

We describe here a modified protocol for the simultaneous quantification of specific eicosanoids formed during stimulation of human platelets in vitro with adenosine diphosphate. The eicosanoids thromboxane B(2) (TXB(2)), arachidonic acid (AA), 12-R-hydroxyeicosatetraenoic acid (12-R-HETE), 12-S-hydroxyheptadecatrienoic acid (12-S-HHTrE) and the internal standard prostaglandin B(1) (PGB(1)) were extracted from human platelets by liquid-liquid extraction using ethyl acetate. This was followed by derivatization and fluorescent detection prior to analysis by reversed phase liquid chromatography. The high-performance liquid chromatographic method consisted of ODS reversed-phase column (3 microm) and a mobile phase of acetonitrile-water (85:15). TXB(2) and AA plasma calibration curves were linear between 6.25 and 125 ng mL(-1) (r(2) > 0.997), whereas for 12-R-HETE and 12-S-HHTrE the curves were linear between 5.0 and 40 ng mL(-1) (r(2) > 0.998). All calibration curve standards had <15% CV (coefficient of variation) and between-run precision, and the percentage relative deviation for replicate (n = 6) quality controls was less than 5.5%. The method was adapted to allow the screening of drugs that may affect either one or both of the lipoxygenase and cyclo-oxygenase pathways.

Calibration↗

Study on the bioavailability of nateglinide-hydroxypropyl-beta-cyclodextrin complex capsule in rabbits by liquid chromatographic-tandem mass spectrometry.

To evaluate the bioavailability of nateglinide-hydroxypropyl-beta-cyclodextrin (HPCD) complex, a rapid and specific liquid chromatographic-tandem mass spectrometric method was developed and validated to determine nateglinide in rabbit serum. The analyte was extracted from serum samples by liquid-liquid extraction, separated on a Zorbax C(18) column and detected by tandem mass spectrometry with an atmospheric pressure chemical ionization interface. Daidzein was used as the internal standard. The method has a lower limit of quantitation of 0.25 mg/L using 200 micro L serum. The intra- and inter-day relative standard deviations calculated from quality control (QC) samples were below 4%. The inter-day relative error was within 1%. Nateglinide serum concentrations in rabbits given nateglinide-hydroxypropyl-beta-cyclodextrin complex were much higher than those given the free drug. Significant difference was observed in main pharmacokinetic parameters of t(max) and C(max) but not AUC(0-t) between the complex and free drug. It was concluded that the absorption rate of nateglinide-HPCD complex was enhanced, compared with that of nateglinide free drug.

2-Hydroxypropyl-beta-cyclodextrin↗

Rapid high-performance liquid chromatographic measurement of buspirone in human plasma after overdose.

For toxicological purposes, a rapid reversed-phase high-performance liquid chromatographic method was developed for the determination of the anxiolytic drug, buspirone, in human plasma. A liquid-liquid procedure was used to extract this compound from plasma in the presence of an internal standard, quinupramine. The analysis was performed on a Spherisorb S5 C8 analytical column with UV detection at 240 nm. No endogenous compounds were found to interfere. A linear response was observed over the concentration range 5-100 ng/mL. A good accuracy (bias < or =7.9%) was achieved for all quality controls, with intra-day and inter-day variation coefficients equal or less than 7.6%. The limit of quantification was 5 ng/mL. Stability of buspirone in plasma stored at different temperatures was checked. This rapid method (run time <12 min) was used to manage an acute poisoning involving buspirone.

Buspirone↗

Determination of lipoic acid in rat plasma by LC-MS/MS with electrospray ionization: assay development, validation and application to a pharamcokinetic study.

A simple, sensitive and specific LC-MS/MS method for the determination of lipoic acid was developed and validated over the linearity range 5-1000 ng/mL (r2 > 0.99) with 200 microL rat plasma using rosigliatzone as an internal standard (IS). The assay procedure involved a simple one-step liquid-liquid extraction of lipoic acid and IS from plasma into ethyl acetate. The organic layer was separated and evaporated under a gentle stream of nitrogen at 40 degrees C. The residue was reconstituted in the mobile phase and injected onto a Hichrom RPB column (4.6 x 250 mm, 5 microm). Separation of lipoic acid and IS was achieved with a mobile phase consisting of 0.05 M formic acid:acetonitrile (40:60, v/v) at a flow rate of 1.0 mL/min. The API-3000 LC-MS/MS was operated under the multiple reaction monitoring mode (MRM) using the electrospray ionization technique. Positive and negative ion acquisition within the same chromatographic run was used in the present method. For lipoic acid a pseudo-molecular ion transition pair was acquired in negative polarity, whereas for IS the transition pair was acquired in positive polarity. Quantitation was determined for both analyte and IS in MRM scan mode. Absolute recovery of lipoic acid and IS was >70 and 97%, respectively. The lower limit of quantification (LLOQ) of lipoic acid was 5.0 ng/mL. The inter- and intra-day precision in the measurement of quality control (QC) samples 5, 15, 400 and 800 ng/mL were in the range 2.18-5.99% relative standard deviation (RSD) and 0.93-13.77% RSD, respectively. Accuracy in the measurement of QC samples was in the range 87.40-114.40% of the nominal values. Analyte and IS were stable in the battery of stability studies, viz. bench-top, auto-sampler and freeze-thaw cycles. Stability of lipoic acid was established for 1 month at -80 degrees C. The application of the assay to a pharmacokinetic study in rats confirmed the utility of the assay.

Animals↗

A validated HPLC determination of the flavone aglycone diosmetin in human plasma.

Diosmetin, 3',5,7-trihydroxy-4'-methoxy flavone, is the aglycone of the flavonoid glycoside diosmin that occurs naturally in foods of plant origin. Diosmin exhibits antioxidant and anti-inflammatory activities, improves venous tone and it is used for the treatment of chronic venous insufficiency. Diosmin is hydrolyzed by enzymes of intestinal micro flora before absorption of its aglycone diosmetin. A specific, sensitive, precise, accurate and robust HPLC assay for the determination of diosmetin in human plasma was developed and validated. Diosmetin and the internal standard 7-ethoxycoumarin were isolated from plasma by liquid-liquid extraction and separated on a C8 reversed-phase column with methanol-water-acetic acid (55:43:2, v/v/v) as the mobile phase at 43 degrees C. Peaks were monitored at 344 nm. The method was linear in the 10-300 ng/mL concentration range (r > 0.999). Recovery for diosmetin and internal standard was greater than 89.7 and 86.8%, respectively. Intra-day and inter-day precision for diosmetin ranged from 1.6 to 4.6 and from 2.2 to 5.3%, respectively, and accuracy was better than 97.9%.

Chromatography, High Pressure Liquid↗

Simultaneous determination of ropivacaine and antipyrine by high performance liquid chromatography and its application to the in vitro transplacental study.

A simple and reliable RP-HPLC method has been developed for the simultaneous determination of ropivacaine and antipyrine in perfusate samples. Samples were analyzed on an ODS column with UV detection at 210 nm after liquid-liquid extraction. The mobile phase consisted of potassium dihydrogenphosphate (25 mM, adjusted to pH 5.0 with phosphoric acid)-acetonitrile (79:21, v/v). The method has been validated to be precise, accurate and linear. It has been applied to the investigation of placental transfer of ropivacaine via a dually perfused cotyledon model of human placenta in vitro.

Amides↗

Determination of abacavir in human plasma by high-performance liquid chromatography with ultraviolet detection and the analytical error function.

A rapid and simple high-performance liquid chromatography method has been developed for the determination of the HIV-1 reverse transcriptase inhibitor abacavir in human plasma. It included a single liquid-liquid extraction procedure with a mixture of ethyl acetate-diethyl ether prior to reversed-phase chromatography on a C18 column and C18 precolumn insert. Ultraviolet detection was set at 285 nm. The mobile phase consisted of water-acetonitrile (83:17, v/v) and the flow rate was kept at 1 mL/min. The total run time for a single analysis was 10 min. The method has been validated over the range 50-2500 ng/mL. The assay was linear over the entire concentration range (r2 = 0.9993). Intra- and inter-day precision and accuracy were less than 8.1 and -5.2%, respectively. The extraction recovery was greater than 94.3%. Abacavir was stable under the relevant storage conditions tested. After the validation, the analytical error function was established as standard deviation (SD; ng/mL) = -1.072 + 0.037C (C = theoretical concentration value). The method developed and its associated analytical error function will be suitable for pharmacokinetic studies and monitoring of HIV-1 patients.

Acetonitriles↗

HPLC determination and pharmacokinetic studies of salvianolic acid B in rat plasma after oral administration of Radix Salviae Miltiorrhizae extract.

A precise and reproducible HPLC method has been established and validated for determination of salvianolic acid B (SalB) in rat plasma after oral administration of Radix Salviae Miltiorrhizae extract. Liquid-liquid extraction was adopted for the sample preparation. Separation was accomplished on a C(18) column with a linear gradient elution consisting of acetonitrile and aqueous phosphoric acid. Ultraviolet detection was at 280 nm. The method was validated over the concentration range 10.8-259.4 microg/mL using 1 mL of plasma. The assay was linear over this concentration range with a coefficient of variation less than 7%. The extraction recovery of SalB was within the range 71-83% with RSD 11%. The mean recovery of the internal standard was 84% (n = 6) with RSD of 5.6%. This method is suitable to determine SalB in plasma and to investigate the pharmacokinetics of SalB.

Acetonitriles↗

Metabolic studies on the total phenolic acids from the roots of Salvia miltiorrhiza in rats.

Phenolic acids are the main active constituents of Salvia miltiorrhiza Bunge. The metabolism of total phenolic acids from the roots of Salvia miltiorrhiza in rats was investigated. A sample preparation method combining the solid-phase extraction with liquid-liquid extraction was established to separate metabolites from the biological matrix. HPLC-UV and HPLC-MS methods were employed to analyze the metabolites. Five metabolites (M1-M5) were identified by HPLC-MS analysis and comparison with those of the reference standards. The fi ve metabolites were characterized as danshensu (M1), caffeic acid (M2), ferulic acid (M3), isoferulic acid (M4) and methylized ferulic acid (M5), respectively. The possible metabolic pathway of the phenolic acids is proposed.

Animals↗

Simultaneous analysis of piperacillin and tazobactam in rabbits: application to pharmacokinetic study.

A simple and rapid assay is developed for the simultaneous analysis of piperacillin and tazobactam in rabbit serum and tissue cage fluid (TCF). To eliminate endogenous interferences, a wavelength switch technique was applied, in which the programmable UV detector changed the monitoring wavelength from 218 to 254 nm at 10 min. After liquid-liquid extraction, sample analyses were performed on a C(18) column by gradient elution; the mobile phase consisted of acetonitrile and phosphate buffer (0.014 m, pH 2.4). Owing to the limited amount of rabbit TCF available, a cross-validation of a proxy matrix was evaluated. The relative standard deviation of the between- and within-batch precision of both compounds was less than 5.1%; the relative error of the between- and within-batch accuracy was less than 7.3%. The recoveries of both compounds in serum and TCF were larger than 80%. This assay was successfully applied to simultaneously analyze piperacillin and tazobactam in rabbit serum and TCF samples.

Animals↗

Determination of amphetamine in dog plasma by gas chromatography with mass selective detection.

This paper describes the validation of an analytical method for the determination of amphetamine in beagle dog plasma by gas chromatography coupled to mass spectrometry (GC-MS). d-Amphetamine-d(6) was used as the internal standard. The method consisted of a rapid single-step liquid-liquid extraction and derivatization of amphetamine with 2,2,2-trichloroethyl chloroformate, followed by sensitive GC-MS detection. This is the first report utilizing the combination of trichloroethyl chloroformate as a derivatization reagent and a deuterated amphetamine analog as an IS for the quantification of amphetamine in plasma. The method was validated in terms of specificity, curve fit, precision, accuracy, recovery and stability, and was acceptable according to FDA draft guidelines for validation of bioanalytical methods. The limit of detection was 0.65 ng/mL. The calibration range was 5-150 ng/mL. The validated method was successfully employed for the quantitation of amphetamine in dog plasma samples for pharmacokinetic profiling.

Amphetamines↗

A validated HPLC method with electrochemical detection for simultaneous assay of 5-aminosalicylic acid and its metabolite in human plasma.

A high-performance liquid chromatographic method was developed, validated and applied to the simultaneous determination of 5-aminosalicylic acid (5-ASA) and its acetylated metabolite (acetyl-5-ASA) in human plasma. The method involves liquid-liquid extraction with methanol followed by isocratic reversed-phase chromatography on a Kromasil KR100 C(18) column with electrochemical detection. The recovery, selectivity, linearity, precision and accuracy of the method were evaluated from spiked human plasma samples. The effects of mobile phase composition, buffer concentration, mobile phase pH and concentration of organic modifiers on retention of 5-ASA, acetyl 5-ASA and internal standard were investigated. Limits' of detection were 5 ng/mL for 5-ASA and 10 ng/mL for acetyl-5-ASA, respectively. The method can be used for supporting therapeutical drug monitoring and pharmacokinetic studies.

Aminosalicylic Acids↗

Quantitative analysis of docetaxel in human plasma using liquid chromatography coupled with tandem mass spectrometry.

An assay for the quantitative determination of docetaxel in human plasma is described. Docetaxel was extracted from the matrix using liquid-liquid extraction with ter-butylmethylether, followed by high-performance liquid chromatographic analysis using an alkaline eluent. Paclitaxel was used as internal standard. Positive ionization electrospray tandem mass spectrometry was performed for selective and sensitive detection. The method was validated according to the FDA guidelines on bioanalytical method validation. The validated range for docetaxel was from 0.25--1000 ng/mL using 200 microL plasma aliquots. The method requires only a limited volume (200 microL) of human plasma and the method can be applied in studies requiring a low lower limit of quantitation of 0.25 ng/mL. The assay was applied successfully in several clinical and pharmacological studies with docetaxel.

Administration, Oral↗

Validation and application of a high-performance liquid chromatography--tandem mass spectrometry assay for mosapride in human plasma.

A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of mosapride (I), a novel and potent gastroprokinetic agent that enhances the upper gastrointestinal motility by stimulating 5-HT(4) receptor. The analyte and internal standard, tamsulosin (II), were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on a reversed-phase Waters symmetry C(18) column with a mobile phase of 0.03% formic acid-acetonitrile (10:90, v/v). The protonated analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 422.3 -->198.3 and m/z 409.1 -->228.1 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 0.5-100.0 ng/mL for mosapride in human plasma. The lower limit of quantitation was 500 pg/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A run time of 2.0 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.

Benzamides↗

High-throughput determination of atrasentan in human plasma by high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry.

Atrasentan (A-147627) is an endothelin antagonist receptor being developed at Abbott Laboratories for the treatment of prostate cancer. A quick and sensitive method for the determination of atrasentan in human plasma has been developed and validated using high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry. A dual-column, single mass spectrometer system is used to provide a reliable and routine means to increase sample throughput. The analytical method involves liquid-liquid extraction and internal standard (A-166790). The plasma samples and internal standard are acidified with 0.3 M hydrochloric acid prior to being extracted into 1:1 (v/v) hexanes--methyl t-butyl ether. The organic extract was evaporated to dryness using heated nitrogen stream and reconstituted with mobile phase. Atrasentan and internal standard were separated with no interference in a Zorbax SB-C(18) analytical column with 2.1 x 50 mm, 5 microm, and a Zorbax C(8) guard column using a mobile phase consisting of 50:50 (v:v) acetonitrile--0.05 M ammonium acetate, pH 4.5, at a flow rate of 0.30 mL/min to provide 4 min chromatograms. For a 250 microL plasma sample volume, the limit of quantitation was approximately 0.3 ng/mL. The calibration was linear from 0.30 to 98.0 ng/mL (r(2) > 0.995). A significant advantage of the method is the ability to employ parallel HPLC separations with detection by a single MS/MS system to provide sensitivity and selectivity sufficient to achieve robust analytical results with a lower limit of quantitation of 0.30 ng/mL and high throughput.

Antineoplastic Agents↗

Rapid, simple and highly sensitive LC-ESI-MS/MS method for the quantification of tamsulosin in human plasma.

A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of tamsulosin (I), a highly selective alpha1-adrenoceptor antagonist used for the treatment of patients with symptomatic benign prostatic hyperplasia. The analyte and internal standard, mosapride (II) were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on a reverse phase Waters symmetry C18 column with a mobile phase of 0.03% formic acid-acetonitrile (30:70, v/v). The protonated analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 409.1 solidus in circle 228.1 and m/z 422.3 solidus in circle 198.3 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 0.1-50.0 ng/mL for tamsulosin in human plasma. The lower limit of quantitation was 100 pg/mL with a relative standard deviation of less than 10%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A run time of 2.0 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.

Adrenergic alpha-Antagonists↗