Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “INTERFEROMETRY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

Contrast enhancement for electronic speckle pattern interferometry fringes by the differential equation enhancement method.

Electronic speckle pattern interferometry fringe patterns usually have poor contrast so it is important to enhance fringe contrast for the extraction of phase from a single fringe pattern. We present new enhancement methods based on differential equations (called DE enhancement methods) to electronic speckle pattern interferometry fringes. The DE enhancement methods transform the image processing to solve differential equations. With the proposed methods, the visibility of the correlation speckle fringe patterns can be improved significantly. We tested the proposed methods on computer-simulated speckle correlation fringes and experimentally obtained fringes, and we compared the new method with other contrast enhancement techniques. The experimental results illustrate the performance of this approach.

Journal Article↗

Wavefront reconstruction by spatial-phase-shift imaging interferometry.

Common-path imaging interferometers offer some advantages over other interferometers, such as insensitivity to vibrations and the ability to be attached to any optical system to analyze an imaged wavefront. We introduce the spatial-phase-shift imaging interferometry technique for surface measurements and wavefront analysis in which different parts of the wavefront undergo certain manipulations in a certain plane along the optical axis. These manipulations replace the reference-beam phase shifting of existing interferometry methods. We present the mathematical algorithm for reconstructing the wavefront from the interference patterns and detail the optical considerations for implementing the optical system. We implemented the spatial phase shift into a working system and used it to measure a variety of objects. Measurement results and comparison with other measurement methods indicate that this approach improves measurement accuracy with respect to existing quantitative phase-measurement methods.

Journal Article↗

Phase-stepped gauge block interferometry using a frequency-tunable visible laser diode.

Frequency changes induced by bias or temperature modulation of injection diode lasers can provide an economical and effective method of applying phase-stepping interferometry to optical metrology. However, the intrinsic frequency instability of these devices limits their use in gauge block interferometry where precise and repeatable phase steps must be maintained simultaneously on two discontinuous surfaces and over relatively long path lengths. We demonstrate a method using a visible injection diode laser, the frequency of which is locked by using a Fabry-Perot interferometer. Small changes to the length of the Fabry-Perot interferometer shift the frequency of the laser producing proportional and repeatable phase steps to the gauge block interferogram. This method has been successfully implemented with a Fizeau-type gauge block interferometer with a phase measurement resolution of 0.005 lambda. The phase data are then processed to map the surface form of gauge blocks up to 100 mm in length and to objectively assess surface shape parameters.

Journal Article↗

Characterization of chromatic dispersion of optical filters by high-stability real-time spectral interferometry.

Chromatic dispersion of optical filters is characterized by what is believed to be novel broadband spectral interferometry, which is based on dual-wavelength heterodyne measurement of spectral phase. High phase stability is achieved by differential phase detection using two lasers for wavelength-swept probe and phase-tracking reference. The technique provides self-tracking interferometry by passive stabilization of optical phase and allows real-time measurement of spectral phase and group delay with a low phase drift of less than 0.04pi. A fiber Bragg grating and a thin-film filter are characterized by this method.

Journal Article↗

Improved optical profiling using the spectral phase in spectrally resolved white-light interferometry.

In spectrally resolved white-light interferometry (SRWLI), the white-light interferogram is decomposed into its monochromatic constituent. The phase of the monochromatic constituents can be determined using a phase-shifting technique over a range of wavelengths. These phase values have fringe order ambiguity. However, the variation of the phase with respect to the wavenumber is linear and its slope gives the absolute value of the optical-path difference. Since the path difference is related to the height of the test object at a point, a line profile can be determined without ambiguity. The slope value, though less precise helps us determine the fringe order. The fringe order combined with the monochromatic phase value gives the absolute profile, which has the precision of phase-shifting interferometry. The presence of noise in the phase may lead to the misidentification of fringe order, which in turn gives unnecessary jumps in the precise profile. The experimental details of measurement on standard samples with SRWLI are discussed in this paper.

Journal Article↗

Chromatic confocal spectral interferometry.

Chromatic confocal spectral interferometry (CCSI) is a novel scheme for topography measurements that combines the techniques of spectral interferometry and chromatic confocal microscopy. This hybrid method allows for white-light interferometric detection with a high NA in a single-shot manner. To the best of our knowledge, CCSI is the first interferometric method that utilizes a confocally filtered and chromatically dispersed focus for detection and simultaneously allows for retrieval of the depth position of reflecting or scattering objects utilizing the phase (modulation frequency) of the interferometric signals acquired. With the chromatically dispersed focus, the depth range of the sensor is decoupled from the NA of the microscope objective.

Journal Article↗

Real-time heterodyne imaging interferometry: focal-plane amplitude and phase demodulation using a three-phase correlation image sensor.

A method of real-time heterodyne imaging interferometry using a three-phase correlation image sensor (3PCIS) is proposed. It simultaneously demodulates the amplitude and phase images of an incident interference pattern at an ordinary frame rate with good accuracy, thus overcoming the trade-off among measurement time, spatial resolution, and demodulation accuracy suffered in conventional interferometry. An experimental system is constructed with a 64x64 3PCIS camera operated at 30 frames/s and a two-frequency He-Ne laser with a beat frequency of 25 kHz. The results obtained for a scanning mirror and heated silicone oil confirm the proposed method.

Journal Article↗

Statistical interferometry based on a fully developed speckle field: an experimental demonstration with noise analysis.

A novel interferometric method named statistical interferometry is proposed and studied. In the method, in contrast to the conventional deterministic interferometry, the complete randomness of the two interfering light fields, i.e., the random interference of the fully developed speckle fields, plays an essential role and is used as a standard of phase in a statistical sense. Preliminary experiments were conducted to verify the validity of the method, followed by a computer simulation. As an experimental result, the accuracy of the measurements of an out-of-plane displacement was confirmed up to lambda/800 by comparison with the heterodyne interferometer. The method has the advantage of simplicity of the optical system required, while at the same time providing high accuracy.

Journal Article↗

Probe transit effect in interferometry of fast moving samples.

When a fast moving transparent sample (with a speed close to c) is probed with a laser pulse, some artifacts can occur from data analysis. These artifacts are connected to the transit time of the probe through the sample and can mask the presence of a steep gradient of refractive index in the sample. We study this problem in the case of interferometry. In fact, the problem can affect the femtosecond interferometry of the media under ultrafast ionization by a propagating laser pulse. Two algorithms are introduced: the first based on the phase difference and the second based on visibility. Both algorithms allow for the reconstruction, under suitable assumptions, of an approximated refractive index profile from the distorted fringes.

Journal Article↗

Highly sensitive direct characterization of femtosecond pulses by electro-optic spectral shearing interferometry.

We report what is to our knowledge the first experimental demonstration of spectral shearing interferometry by use of an electro-optic temporal phase modulator to generate the spectral shear. This approach achieves far better sensitivity than nonlinear optical pulse characterization techniques, including other versions of spectral shearing interferometry. Temporal phase modulation is conceptually simple and is implemented easily with telecommunication components. The technique is versatile, and a wide range of pulse durations can be measured with minimal changes in the setup. We demonstrate the accurate characterization of a 156-MHz train of 1540-nm pulses with durations ranging from 750 fs to more than 30 ps after various amounts of chirping, at average powers below 1 microW.

Journal Article↗

Coherent measurement of short laser pulses based on spectral interferometry resolved in time.

We propose a new method for measuring the phase and the amplitude of a short laser pulse that is based on shearing interferometry in the spectral domain combined with time gating. The method has several features in common with spectral interferometry for direct electric-field reconstruction, in particular, fast and direct reconstruction of the phase. Accurate measurement of the phase added to an 80-fs pulse by a block of F4 glass demonstrates the technique.

Journal Article↗

Tunable-optical-filter-based white-light interferometry for sensing.

We describe tunable-optical-filter-based white-light interferometry for sensor interrogation. By introducing a tunable optical filter into a white-light interferometry system, one can interrogate an interferometer with either quadrature demodulation or spectral-domain detection at low cost. To demonstrate the feasibility of effectively demodulating various types of interferometric sensor, experiments have been performed using an extrinsic Fabry-Perot tunable filter to interrogate two extrinsic Fabry-Perot interferometric temperature sensors and a diaphragm-based pressure sensor.

Journal Article↗

Spiral interferometry.

We present a surprising modification of optical interferometry. A so-called spiral phase element in the beam path of a standard microscope results in an interferogram of phase samples, for which the interference fringes have the shape of spirals instead of closed contour lines as in traditional interferograms. This configuration overrides the basic problem of interferometry, i.e., that elevations and depressions cannot be distinguished. Therefore a complete sample profile can be reconstructed from a single exposure, promising, e.g., high-speed metrology with a single laser pulse. The method is easy to implement, it does not require a spatially separated reference beam, and it is optimally stable against environmental noise.

Journal Article↗

Random depth access full-field heterodyne low-coherence interferometry utilizing acousto-optic modulation and a complementary metaloxide semiconductor camera.

With analog scanning, time-domain low-coherence interferometry lacks precise depth information, and optical carrier generation demands a linear scanning speed. Full-field heterodyne low-coherence interferometry that uses a logarithmic complementary metal-oxide semiconductor camera, acousto-optic modulation, and digital depth stepping is reported, with which random regions of interest, lateral and axial, can be accessed. Furthermore, nanometer profilometry is possible through heterodyne phase retrieval of the interference signal. The approach demonstrates inexpensive yet high-precision functional machine vision offering true digital random access in three dimensions.

Journal Article↗

Noninvasive picoliter volume thermometry based on backscatter interferometry.

Using the on-chip refractive index (RI) detector based on backscatter interferometry, sensitive, small volume, noninvasive thermometry can be performed. The current optical configuration for the on-chip interferometric backscatter detector (OCIBD) is quite simple and consists of an unfocused laser, an unaltered chip with a hemispherical channel and a photodetector. Alignment is straightforward with the only requirement being that the beam fully fills the channel. The interaction of an unfocused laser beam with the uncoated etched channel with a curvature within the silica plate (chip) produces fringes whose positional changes scale with respect to the refractive index (RI), n, of the fluid in the channel. Due to the inherently high value of dn/dT for most fluids and the high sensitivity of OCIBD to RI changes, the measurement of small temperature variations in sub-nanoliter volumes is possible. Performing OCIBD with a 75 microm diameter laser beam on a silica chip that contains an etched channel with a 40 microm radius facilitates noninvasive thermometry on a N-(2-hydroxyethyl)piperazine-(2-ethanesulfonic acid) (HEPES) solution in a 188 x 10(-12) L probe volume with a temperature resolution of 9.9 x 10(-4) degrees C, at the 99% confidence level.

HEPES↗

Noninvasive fluid flow measurements in microfluidic channels with backscatter interferometry.

The ability to measure fluid velocity within picoliter volumes or on-chip noninvasively, is important toward fully realizing the potential of microfluidics and micrototal analysis systems, particularly in applications such as micro-high-performance liquid chromatography (HPLC) or in metering mixing where the flow rate must be quantified. Additionally, these measurements need to be performed directly on moving fluids in a noninvasive fashion. We presented here the proof of principle experiments showing nonintrusive fluid flow measurements can be accomplished on-chip using a pump and probe configuration with backscattering interferometry. The on-chip interferometric backscatter detector (OCIBD) is based on a fiber-coupled HeNe laser that illuminates a portion of an isotropically etched 40 microm radius channel and a position sensitive transducer to measure fringe pattern shifts. An infrared laser with a mechanical shutter is used to heat a section of a flowing volume and the resulting refractive index (RI) change is detected with the OCIBD downstream as a time-dependent RI perturbation. Fluid velocity is quantified as changes in the phase difference between the shutter signal and the OCIBD detected signal in the Fourier domain. The experiments are performed in the range of 3-6 microL/h with 3sigma detection limits determined to be 0.127 nL/s. Additionally, the RI response of the system is calibrated using temperature changes as well as glycerol solutions.

Equipment Design↗

Evaluation of double-exposure holographic interferometry for biomechanical measurements in vitro.

Double-exposure holographic interferometry is a nondestructive testing technique for measuring displacement and strain in a test object. A standard hologram contains three-dimensional information about an object. However, the holographic interferogram has additional information, as a series of interference bands overlaid on the three-dimensional image of the object contains information about object deformation. Interferograms were produced for intact cadaveric femora and cadaveric femora with implanted titanium alloy and cobalt-chromium alloy femoral components. A force was applied to the femoral head to simulate single leg stance, and changes in specimen deformation were observed as additional incremental loads were applied. We have observed that the femur behaves as a bending beam and that the holographic technique allows the position of maximal deflection to be identified and the magnitude of femoral displacement from the load axis to be determined at any point within the field of view. The effects of the modulus of the implanted stem on the bending characteristics of the composite structure were clearly seen in the interferograms. This communication presents a photographic analysis of the double exposure interferograms recorded, as well as a critique of the technique for biomechanical measurements in vitro.

Biomechanical Phenomena↗

Determination of the dynamics of restored teeth by 3D electronic speckle pattern interferometry.

BACKGROUND AND OBJECTIVES: The difficulties typically encountered in studying the effects of restorations on tooth reinforcement are often due to the 3-dimensional (3D) nature of deformation. Therefore, electronic 3D-Speckle-Interferometry (3D-ESPI) was used to assess the impact of different restorative materials on the deformation of teeth. STUDY DESIGN/MATERIALS AND METHODS: Small and large MOD-preparations in extracted premolars were restored with gold inlays, ceramic inlays, composite resin inlays, amalgam, or composite resin. The restorations and cusps were loaded (90 N) and the deformation was assessed by 3D-ESPI. RESULTS: Teeth with small restorations were deformed only slightly and the differences between the materials were minimal (P>0.05). In contrast, teeth with large restorations displayed material-specific deformation patterns: (a) all materials led to decreased deformation as compared with unfilled teeth, (b) elastic materials caused only local deformation, (c) non-adhesive materials resulted in translation of the restoration and marginal discrepancies, (d) adhesive inlays brought about increased deformation of the luting resin composite, (e) loading of the cusps caused higher deformation than loading of the restorations, and (f) bonded restorations stabilized the cusps. CONCLUSIONS: The results show that the deformation pattern of restored teeth is material-specific but the extent of deformation is primarily limited by the remaining tooth substance.

Adult↗