Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Hydrocodone”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

Dental therapeutic practice patterns in the U.S. II. Analgesics, corticosteroids, and antibiotics.

This article examines the prescribing practices for peripherally acting and centrally acting analgesics, corticosteroids, and antibiotics following third molar extraction. A nationwide survey involving the prescribing patterns of a random national sample of 850 practicing oral surgeons was performed in 2004. Ibuprofen was the peripherally acting analgesic respondents used most frequently in the previous month, selected by 73.5% of the respondents. The ibuprofen dose prescribed most frequently was 800 mg, followed by doses of 600 mg and 400 mg. The centrally acting analgesic prescribed most frequently was the combination formulation of hydrocodone with acetaminophen, selected by 64.0% of the respondents. Recommendations for oral analgesics to manage postoperative pain relied on the peripherally acting analgesic ibuprofen or the centrally acting analgesic combination formulation hydrocodone with acetaminophen. Routine instructions to use centrally acting analgesics "as needed for pain" suggest that centrally acting analgesics are offered to manage pain that postoperative peripherally acting analgesics and intraoperative long-acting local anesthetics do not control adequately. The frequency with which oral and maxillofacial surgeons administered antibiotics and corticosteroids varied widely based on perceived patient need and dentist expectations.

Acetaminophen↗

Important drugs for cough in advanced cancer.

Cough is a defense mechanism that prevents the entry of noxious materials into the respiratory system and clears foreign materials and excess secretions from the lungs and respiratory tract. In advanced cancer, it is a common symptom that interferes with the patient's daily activity and quality of life. Empiric treatment with antitussive agents is often needed. Two classes of antitussive drugs are available: (1) centrally acting: (a) opioids and (b) non-opioids; (2) peripherally acting: (a) directly and (b) indirectly. Antitussive availability varies widely around the world. Many antitussives, such as benzonatate, codeine, hydrocodone, and dextromethorphan, were extensively studied in the acute and chronic cough settings and showed relatively high efficacy and safety profiles. Benzonatate, clobutinol, dihydrocodeine, hydrocodone, and levodropropizine were the only antitussives specifically studied in cancer and advanced cancer cough. They all have shown to be effective and safe in recommended daily dose for cough. In advanced cancer the patient's current medications, previous antitussive use, the availability of routes of administration, any history of drug abuse, the presence of other symptoms and other factors, all have a role in the selection of antitussives for prescription. A good knowledge of the pharmacokinetics, dosage, efficacy, and side effects of the available antitussives provides for better management.

Antitussive Agents↗

Types of medication errors in North Carolina nursing homes: a target for quality improvement.

BACKGROUND: Medication errors are an important problem in nursing homes, but little is known about the types of medications involved in errors in this setting. Gaining a better understanding of the types of medications commonly involved in medication errors in nursing homes would be an important step toward quality improvement. OBJECTIVES: This study sought to describe the types of medication errors most frequently reported to a statewide repository by North Carolina nursing homes. We also examined whether nursing homes reporting an error involving a drug on the updated Beers list of medications considered potentially inappropriate for use in the elderly were likely to report a greater number of medication errors or more harmful medication errors compared with nursing homes that did not report such an error. METHODS: Medication errors were defined as preventable events that had the potential to cause/lead to or actually caused/led to inappropriate medication use or patient harm. We analyzed summary reports of medication errors submitted to the State of North Carolina by licensed nursing homes for the 9-month period from January 1, 2004, to September 30, 2004, using a Web-based reporting system. Drugs commonly involved in medication errors were summarized for all nursing homes in the state. Errors involving medications on the updated Beers list also were identified. Nursing homes were profiled and compared according to the type of medication error and whether the error reached the patient and/or caused harm. RESULTS: Among the 384 licensed nursing homes included in our analysis, 9272 medication errors were reported. The specific medication involved was documented for 5986 of these errors. The medications most commonly involved in an error were lorazepam (457 errors [8%]), warfarin (349 [6%]), insulin (332 [6%]), hydrocodone and hydrocodone combinations (233 [4%]), furosemide (173 [3%]), and the fentanyl patch (150 [3%]). The medication errors disproportionately included central nervous system agents (16%) and analgesics (11%). Medications considered potentially inappropriate in the elderly were frequently involved in the reported errors (10% of all reported errors), with the greatest number of such errors associated with lorazepam (457 [8%]), alprazolam (130 [2%]), and digoxin (74 [1%]). Nursing homes reporting potentially inappropriate drugs among their 10 most common medication errors also reported a significantly greater mean number of errors compared with nursing homes that did not report such errors (26.9 vs 17.6, respectively; P < 0.001), as well as a significantly greater number of errors that reached the patient (6148 vs 1393; P < 0.001). CONCLUSION: Based on the experience in North Carolina, quality improvement efforts in nursing homes should focus on the medications commonly involved in errors and should continue to discourage or closely monitor the use of medications considered potentially inappropriate in the elderly.

Adverse Drug Reaction Reporting Systems↗

Selective potentiation of opioid analgesia by nonsteroidal anti-inflammatory drugs.

Opioids are often used in conjunction with nonsteroidal anti-inflammatory drugs (NSAIDs) in the treatment of moderate to severe pain. In this study we have examined interactions between these two classes of drugs. NSAIDs are inactive in the radiant heat tail-flick test, an assay of moderate to severe pain in which opioids are effective. In this assay, ibuprofen potentiated the analgesic actions of hydrocodone and oxycodone, shifting their ED(50) values by 2.5-fold and 4.6-fold despite its inactivity when given alone. These opioid/NSAID interactions were dependent upon both the opioid and the NSAID. Neither aspirin nor ketorolac influenced hydrocodone actions in this model and ibuprofen did not potentiate fentanyl or morphine analgesia. Together, these studies demonstrate potent interactions between selected combinations of opioids and NSAIDS and may help explain the clinical utility of combinations. However, the findings also illustrate differences between the drugs within each class.

Analgesics, Opioid↗

Hair analysis for opiates: evaluation of washing and incubation procedures.

Hair analysis of drugs of abuse has been a subject of interest from a clinical, social and forensic perspective for years because of the broad time detection window after intake in comparison to urine or blood. However, the correct and reliable interpretation of opiates findings in an authentic hair sample requires optimalisation and standardisation of decontamination and incubation procedures. Comparing various published methods, we have found some variability in them and no unequivocal recommended procedure for starting with a method directly. Therefore, various combinations of solvents, of various polarity, as washing solvents were tested for removing opiates from the external surface of real hair samples. The yields of opiates from these washings were compared with the yields from the interior of the hair matrix after digestion with various procedures. The opiates after digestion were cleaned up from resulting solution on extraction columns with mixed solid-phase and analysed by GC-MS in standard EI mode after silylation. The efficiencies of neutral (Söerensen buffer, pH 7.4), acid (0.1 M HCl) and basic (1 M NaOH) digestion of the hair matrix were evaluated and the relative recoveries for morphine, codeine, dihydrocodeine and hydrocodone were compared. As it is very problematic to imitate the reference hair sample with a specific amount of analytes incorporated inside, which can be used for calibration to get a close estimate of the quantities of analytes inside the solid authentic sample, the total digestion of a hair sample in basic medium was considered to be a very important reference basis for quantitative determinations. The ratios of hydrolysis of labile 6-acetylmorphine or acetylcodeine were tested and evaluated in practical routine conditions of acid or neutral digestion of hair. Comparing the three methods of incubation of authentic hair samples, the methods using 1 M NaOH or 0.1 M HCl yielded higher recoveries of total equivalents of morphine or codeine, whereas the incubation in Söerensen buffer allowed the reflection of real ratios of labile metabolites and/or parent compounds in an original sample. This method has been shown to be capable of detecting hydrocodone in hair with other opiates concomitantly and to indicate the drug abuse pattern of a person at various time intervals in the past.

Gas Chromatography-Mass Spectrometry↗

A field evaluation of five on-site drug-testing devices.

A field study was performed at two police agencies to evaluate the utility and accuracy of five on-site urine analysis drug-testing devices when used to test driving under the influence (DUI) arrestees. The devices evaluated were AccuSign, Rapid Drug Screen, TesTcup-5, TesTstik, and Triage. Standard workplace screening cut-off concentrations were used and samples were tested for marijuana, cocaine and metabolites, amphetamine(s), opiates, and PCP (except opiates 300 ng/mL). Four-hundred arrestees were recruited at each site, informed consent was obtained, and urine specimens were collected from each subject for analysis. Police officers conducted the testing with one device, and trained technicians performed testing with the other four devices. The device used by the officers was rotated. All positive and 5% of the negative samples were confirmed in a laboratory using mass spectrometry. Laboratory cut-off concentrations were 4 ng/mL for carboxy-THC; 50 ng/mL for benzoylecgonine; 100 ng/mL for amphetamines; 50 ng/mL for opiates; and 5 ng/mL for PCP. Approximately one-third (36%) of the subjects tested positive for at least one drug. No randomly selected sample, that tested negative on the devices, tested positive at the laboratory. Based on 800 specimens, the false-negative rate for each device was < 1% for all drug classes. A false positive was defined as testing positive with the device, but the specimen did not contain detectable drug, given the study reporting criteria. For marijuana, benzoylecgonine, and opiates, all devices had < or = 0.25% false-positive rates. For PCP, the false-positive rates were all < or = 1.5%. For amphetamine(s), the false-positive rates were all < or = 1.75%. These rates were adjusted because study confirmation batteries included methylenedioxyamphetamine, methylenedioxymethamphetamine (MDMA), additional over-the-counter sympathomimetic amines, hydromorphone, and hydrocodone. Without the expanded confirmation battery, false-positive rates approached 4% (Triage) for amphetamines and were > or = 2.25% for opiates. Fifty to 90% of the positive amphetamine(s) samples contained MDMA. A similar percentage of the opiate-positive samples contained hydromorphone or hydrocodone. When additional drugs were included in the confirmation testing, it was concluded that the on-site urine analysis drug-testing results were useful in DUI investigations.

Automobile Driving↗

Metaxalone (Skelaxin)-related death.

The case history and toxicological findings of a fatal multi-drug overdose involving metaxalone (Skelaxin) are presented. Gas-liquid chromatography with flame-ionization detection and gas chromatography-mass spectrometry were used to determine the following drug concentrations (mg/L) in aortic blood: 19 mg/L metaxalone; 190 mg/L acetaminophen; 0.28 mg/L hydrocodone; and < 0.1 mg/L diazepam, nordiazepam, amitriptyline, and nortriptyline. The following concentrations of metaxalone were reported in alternate specimens: 17 mg/L in femoral blood; 44 mg/L in bile; 70 mg/kg in liver; 7 mg/L in urine; 202 mg/kg in gastric contents; and 14 mg/L in vitreous humor. These concentrations were determined using both direct extraction and the method of standard addition. The quantitative results obtained by both procedures were in good agreement. Because of the limited information published on metaxalone toxicity, the pathologist assigned the manner and cause of death as accidental acute hydrocodone intoxication. Four additional cases in which metaxalone was present were analyzed for comparison. Two cases were probable drug-related deaths and had metaxalone aorta blood concentrations of 18 and 11 mg/L. The other two cases had therapeutic metaxalone concentrations in the aortic blood of < 0.75 and 2.1 mg/L.

Adult↗

Evaluation of the DRI oxycodone immunoassay for the detection of oxycodone in urine.

We evaluated the performance of the DRI Oxycodone (DRI-Oxy) enzyme immunoassay for the detection of oxycodone and its primary metabolite, oxymorphone, in urine, by testing 1523 consecutive urine specimens collected from pain management patients. All 1523 specimens were tested with the DRI-Oxy assay at a cut-off of 100 ng/mL and then analyzed by gas chromatography-mass spectrometry (GC-MS) for opiates, including oxycodone and oxymorphone. Approximately 29% (435) of the 1523 specimens yielded positive results by the DRI-Oxy assay. Of these 435 specimens, GC-MS confirmed the presence of oxycodone and/or oxymorphone at >100 ng/mL in 433 specimens, an agreement of 99.5%. In addition to oxycodone and/or oxymorphone, 189 of the 433 positive specimens contained other opiates including codeine, hydrocodone, hydromorphone, and morphine. These other opiates were also present in 54% (590/1084) of the oxycodone negative specimens. The DRI-Oxy assay demonstrated no cross-reactivity, yielding negative results, with specimens containing concentrations of codeine, >75,000 ng/mL; hydrocodone, >75,000 ng/mL; hydromorphone, >12,000 ng/mL; and morphine, >163,000 ng/mL. From the presented study, the sensitivity of the DRI-Oxy was 0.991 and the selectivity 0.998. The DRI-Oxy assay provided a highly reliable method for the detection of oxycodone and/or oxymorphone in urine specimens.

Forensic Medicine↗

Comparison of an automated and point-of-care immunoassay to GC-MS for urine oxycodone testing in the clinical laboratory.

OxyContin, a controlled-release formulation of oxycodone, is increasingly abused. Monitoring patient compliance by urine drug testing may deter illegal diversion of OxyContin. Two urine immunoassays were evaluated with a 100 ng/mL cutoff for oxycodone. The Microgenics Corporation Oxycodone DRI on the Bayer ADVIA 1650 and a point-of-care (POC) immunoassay, Monitect Oxycodone POC from Branan Medical Corporation, were compared to gas chromatography-mass spectrometry (GC-MS) with a detection limit of 50 ng/mL free oxycodone. Between-day precision for DRI yielded coefficients of variation from 3.9% to 7.0% at 75 and 125 ng/mL. Fifty-two positive and 52 negative urines were tested. The DRI had a 100% agreement with GC-MS. Two positive specimens had free oxycodone < 50 ng/mL, but oxycodone metabolites, oxymorphone and oxycodone glucuronide > 100 ng/mL, were identified by GC-MS analysis. The POC assay had two false positives and 15 indeterminate (+/-) results. Codeine or hydrocodone was present in all but one of these samples. There was no interference with DRI from morphine, codeine, hydrocodone, hydromorphone, dihydrocodeine, or 6-monoacetyl morphine. Four-hundred and ninety urine samples were subsequently tested with DRI to estimate the oxycodone-positive rate at our hospital, and 47 (9.4%) were positive. The confirmation rate with GC-MS for free oxycodone, not including metabolites, was 93%. The Microgenics DRI offers good performance for oxycodone urine testing and is a better choice for the clinical laboratory than the POC assay. Confirmation of screened positive samples requires a method that can detect total oxycodone and oxymorphone.

Calibration↗

Radioimmunological screening and gas chromatographic determination of morphine and related narcotic analgesics in post mortem blood.

A sensitive, reproducible, and relatively specific procedure is presented for the screening, identification, and quantitation of morphine, hydromorphone, codeine, oxycodone, and hydrocodone in autopsy blood. The drugs are isolated from whole blood by adsorption on an XAD-2 resin slurry and subsequent elution with an organic solvent mixture. Part of the resin extract is screened for morphine and related cross-reacting compounds by a commercially available radioimmunoassay (RIA) and the remainder of the same extract is analyzed by gas chromatography using a nitrogen/phosphorus detector (GC/NP). The procedure has been used frequently in forensic toxicological casework. Since toxic blood concentrations of hydrocodone have not been well documented, the results of toxicological examination of two fatalities involving this drug are presented.

Adult↗

Comparative metabolism of codeine in man, rat, dog, guinea-pig and rabbit: identification of four new metabolites.

The metabolism and excretion of codeine and its metabolites in untreated urine of man, rat, dog, guinea-pig and rabbit have been examined. Metabolites were identified by gas chromatography mass spectrometry operated in the chemical ionization mode (methane). Concentrations of codeine and metabolites were measured by selected ion monitoring. Both codeine and norcodeine were detected in the urine of all species but a new metabolite, hydrocodone, was found only in the urine from man, guinea-pig and dog. Additional metabolites (presumably resulting from the metabolism of hydrocodone) were also detected in man and guinea-pig. Overall recoveries of drug and metabolites from untreated urine were low for all species.

Adult↗

Activation of G-proteins by morphine and codeine congeners: insights to the relevance of O- and N-demethylated metabolites at mu- and delta-opioid receptors.

Phenotypic differences in analgesic sensitivity to codeine (3-methoxymorphine) results from polymorphisms in cytochrome P450-2D6, which catalyzes O-demethylation of codeine to morphine. However, O-demethylation reportedly is not required for analgesic activity of the 7,8-saturated codeine congeners dihydrocodeine, hydrocodone, and oxycodone. This study determined the potency and efficacy of these compounds and their demethylated derivatives to stimulate mu- and delta-opioid receptor-mediated G-protein activation using agonist-stimulated guanosine 5'-O-(3-[(35)S]thio)triphosphate ([(35)S]GTP gamma S) binding. Results showed that 7,8-saturated codeine congeners were more efficacious than codeine in activating mu-receptors, but only dihydrocodeine was more efficacious at delta-receptors. Hydrocodone and oxycodone were approximately 10-fold more potent than codeine and dihydrocodeine at either receptor. Morphine-like compounds with a 3-hydroxy group were approximately 30- to 100-fold more potent than their 3-methoxy analogs at the mu-receptor, and these compounds generally exhibited greater efficacy (e.g., morphine produced 2-fold greater maximal stimulation than codeine). Removal of the N-methyl group did not affect efficacy or potency of codeine congeners to activate mu-receptors, whereas this modification generally increased efficacy but decreased potency of morphine congeners. At the delta receptor, morphine congeners showed greater potency and structure-dependent differences in efficacy compared with codeine congeners, whereas removal of the N-methyl group had effects similar to those observed at the mu-receptor. These results demonstrate that 7,8-saturated codeine congeners are more efficacious than codeine, which may explain their lack of requirement for 3-O-demethylation in vivo. Nonetheless, because all 7,8-saturated codeine congeners were significantly less potent than their morphine derivatives, further research is needed to understand the relationship between metabolism and in vivo activity of these compounds.

Animals↗

Comparison of the antinociceptive response to morphine and morphine-like compounds in male and female Sprague-Dawley rats.

Male rats are more sensitive to the antinociceptive effects of morphine than female rats. This difference is seen across several rat strains using a variety of nociceptive stimuli. However, the literature in regard to sex differences in antinociceptive responses to mu-opioids other than morphine is less consistent. The present study was designed to examine whether there is a structure-activity rationale that determines which mu-opioids will show a differential antinociceptive response between male and female rats. A series of morphinans closely related in structure to morphine, namely, codeine, heroin, hydrocodone, hydromorphone, oxymorphone, and oxycodone, were examined for their antinociceptive activity in male and female Sprague-Dawley rats and compared with the structurally unrelated mu-opioid agonists methadone and fentanyl. Antinociception was measured by the warm-water tail-withdrawal assay. The results show that morphine is more potent in males compared with females > hydromorphone = hydrocodone = oxymorphone, but there was no observable sex difference in the antinociceptive potency of codeine, heroin, oxycodone, methadone, or fentanyl. The potency to stimulate guanosine 5'-O-(3-[35 S]thio)triphosphate ([35S]GTPgammaS) binding and binding affinity of the various morphinans was compared in rat glioma C6 cells expressing the rat mu-opioid receptor; relative efficacy was also compared by stimulation of [35S]GTPgammaS binding in slices of rat brain thalamus. The presence of a sex difference in antinociceptive responsiveness was not related to drug potency, efficacy, or affinity. Consequently, it is likely that differential metabolism of the opioid, possibly by glucuronidation, determines the presence or absence of a sex difference.

Analgesics, Opioid↗

Pharmacokinetic drug interactions of morphine, codeine, and their derivatives: theory and clinical reality, Part II.

Pharmacokinetic drug-drug interactions with codeine, dihydrocodeine, hydrocodone, oxycodone, and buprenorphine are reviewed in this column. These compounds have a very similar chemical structure to morphine. Unlike morphine, which is metabolized chiefly through conjugation reactions with uridine diphosphate glucuronosyl transferase (UGT) enzymes, these five drugs are metabolized both through oxidative reactions by the cytochrome P450 (CYP450) enzyme and conjugation by UGT enzymes. There is controversy as to whether codeine, dihydrocodeine, and hydrocodone are actually prodrugs requiring activation by the CYP450 2D6 enzyme or UGT enzymes. Oxycodone and buprenorphine, however, are clearly not prodrugs and are metabolized by the CYP450 2D6 and 3A4 enzymes, respectively. Knowledge of this metabolism assists in the understanding for the potential of drug-drug interactions with these drugs. This understanding is important so that clinicians can choose the proper dosages for analgesia and anticipate potential drug-drug interactions.

Codeine↗

6-oxo-morphinane oximes: pharmacology, chemistry and analytical application.

The permanent therapeutic importance of morphine derivatives in pain treatment has inspired continual synthetic efforts to modify the rigid pentacyclic systems in search for new selective analgesic agents. As a result, several morphinane oximes have been synthesized recently, which have the additional advantage of possessing an oxime group that can provide a method for selective determination of opiate alkaloids in biological matrices. The oximes of hydrocodone and oxycodone have stronger analgesic effect than the parent ketones and they also proved to be effective in preventing the respiratory depressant and hypotensive actions of fentanyl. In this work a review is given on the present status of oxime pharmacology, chemistry and analysis and also the oxime and O-methyl oxime formation of 6-oxo-morphinanes with therapeutic interest (codeinone, oxycodone, hydrocodone and 14-OH-codeinone). The oxime formation was monitored by reversed-phase HPLC and the chromatographic properties of oxime isomers have been characterized. The assignation of the individual isomers isolated by preparative HPLC was performed by (1)H NMR spectroscopy based on the chemical shift differences of the 5-H signals. In this way the isomeric ratio in the oxime products could also be determined. It was found that in the case of Delta(7)-6-oxo-morphinanes, depending on the substituents, the formation of the Z-isomer highly dominates (73-96%) over that of the E-isomer. However, for the saturated 7,8-(dihydro) derivatives the E-isomer is definitely preferred (>98%). In conclusion of a survey on the theoretical background of oxime isomerism, the conformational differences between the saturated and unsaturated morphinane systems were found responsible for the different E/Z ratios. On the basis of the isomeric ratio and the on-line CD and UV spectra of the pure isomers, the molar ellipticities and absorbancies of the isomers were calculated by a parameter estimation method.

Chromatography, High Pressure Liquid↗

Identifying appropriate subjects for abuse liability studies using prestudy pharmacological testing.

Drug abuse liability testing usually involves a subject population of individuals who are current or former drug abusers. To determine whether choosing subjects from a wider and more diverse population of nondrug abusers results in subjective response patterns that are pharmacologically associated with drug abuse liability, a series of studies were conducted using the prescription opiate hydromorphone and the barbiturate secobarbital to prescreen subjects before their acceptance into large multidrug, multidose abuse liability studies. The results of these prescreening studies show that there were some subjects who were not able to report consistently and reliably relevant drug effects, even though they received pharmacologically active doses as measured by objective indexes such as pupil diameter for the opiate study and psychomotor impairment for the barbiturate study. To test the consistency of these results, several of the subjects from the hydromorphone screening were retested with hydrocodone. The results demonstrate that subjects who were unable to report positive subjective effects of hydromorphone were also unable to respond appropriately to hydrocodone, and subjects who responded appropriately to hydromorphone in the prescreening study consistently responded to another opiate. Using this prescreening methodology has allowed sensitive and reliable data on the abuse liability of benzodiazepine agonists and partial agonists, barbiturates, carbamate compounds, amphetamines, selective serotonin reuptake inhibitors and prescription opiate compounds to be generated using a nondrug abusing population. In conclusion, due to the relative heterogeneity of a population of nondrug abusers compared with a drug abusing population, it is necessary to prescreen subjects for their ability to detect and report subjective drug effects, and to distinguish the effects of an active drug from those of placebo. Selecting subjects from this population has several advantages over selecting subjects from the drug abusing population that outweigh any inconvenience of this simple prescreening methodology.

Adult↗

A comparison of crushed ice and continuous flow cold therapy.

Crushed ice was compared to continuous flow cold therapy for control of postoperative pain after arthroscopic patellar tendon autograft anterior cruciate ligament (ACL) reconstruction. With all other variables held constant, cold was administered by either continuous flow (group 1) or crushed ice (group 2). The cold therapy was constant for 3 days, then as needed in days 4 through 7. Data were collected by investigator evaluations and patient diaries. Pain was assessed by visual analog scale (VAS) and categorical pain scale (Likert). Eighty-seven patients were included (52 continuous flow and 35 crushed ice). Continuous passive motion averaged 54 hours for group 1 and 43 hours for group 2 (P<.05). Knee motion at one week averaged more (5 degrees/88 degrees) for group 1 (flexion range: 48 degrees-155 degrees) than for group 2 (6 degrees/77 degrees) (flexion range: 25 degrees-125 degrees) (P=.03). Likert pain scores for group 2 patients were always statistically greater than group 1 patients from the first hour through postoperative day 6 (P<.01). The average VAS pain was always greater for group 2 and statistically greater for postoperative day 1 (P<.01). Hydrocodone bitartrate with acetaminophen use in group 2 was greater than in group 1 for postoperative days 1 (P<.001) and 2 (P=.035). The respective cold modality VAS measured performance was 9.1 for group 1 and 7.8 for group 2 (P<.01). During postoperative days 4 through 6, group 1 patients applied their cold modality for 47.9 hours but group 2 patients applied their cold modality for 29.5 hours (P<.01). Compared to crushed ice, continuous flow cold therapy lowered VAS and Likert pain scores more, reduced hydrocodone bitartrate with acetaminophen use, was used more often, increased continuous passive motion, increased 1-week knee flexion, and was given significantly higher performance ratings by patients. Continuous flow cold is superior to crushed ice for outpatient ACL reconstruction pain and should not be considered an equivalent modality.

Adult↗

Nanogram level quantitation of oxycodone in human plasma by capillary gas chromatography using nitrogen-phosphorus selective detection.

A sensitive and specific capillary gas chromatographic assay is reported for the quantitation of oxycodone in human plasma. The technique involves a single extraction of oxycodone and internal standard (hydrocodone) from plasma by toluene containing 1% isopropanol. Separation is achieved on a methyl silicone (HP-1) fused-silica capillary column (25 m x 0.2 mm I.D., 0.33 microns film thickness) and detection is by nitrogen-phosphorus selective mode. The minimum quantifiable limit is 1.8 ng/ml using 2 ml of plasma. The method is applicable to characterize the plasma profile of oxycodone in humans after a single oral 5-mg oxycodone hydrochloride tablet.

Chromatography, Gas↗