Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Friction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

Friction of total hip replacements with different bearings and loading conditions.

Metal-on-ultra-high molecular weight polyethylene (UHMWPE) total hip replacements have been the most popular and clinically successful implants to date. However, it is well documented that the wear debris from these prostheses contributes to osteolysis and ultimate failure of the prosthesis, hence alternative materials have been sought. A range of 28 mm diameter bearings were investigated using a hip friction simulator, including conventional material combinations such as metal-on-UHWMPE, ceramic-on-ceramic (CoC), and metal-on-metal (MoM), as well as novel ceramic-on-metal (CoM) pairings. Studies were performed under different swing-phase load and lubricant conditions. The friction factors were lowest in the ceramic bearings, with the CoC bearing having the lowest friction factor in all conditions. CoM bearings also had low friction factors compared with MoM, and the trends were similar to CoC bearings for all test conditions. Increasing swing phase load was shown to cause an increase in friction factor in all tests. Increased serum concentration resulted in increased friction factor in all material combinations, except MoM, where increased serum concentration produced a significant reduction in friction factor.

Biocompatible Materials↗

Friction of ceramic and metal hip hemi-endoprostheses against cadaveric acetabula.

INTRODUCTION: Studies of hip arthroplasty have dealt mainly with total endoprosthesis, while tribology measurement values of hemi-endoprosthetic implants are rare. The small amount of experimental tribological data concerning materials of hemi-endoprosthetic implants in the form of pendulum trials, animal experiments, in vivo measurements on human hip joints and pin on disc studies report friction coefficients between 0.014 and 0.57; the friction coefficients measured in fresh human cadaver hip joints were determined between 0.001 and 0.08. MATERIALS AND METHODS: The HEPFlEx-hip simulator was constructed to test the friction coefficients of unipolar femur head hemi-endoprostheses made of metal or ceramic against fresh cadaveric acetabula. Its plane of movement is uniaxial with a flexion-extension movement of +30/-18 degrees . The force is produced pneumatically dynamic with amounts of 2.5 kN. Newborn calf serum serves as a lubricant. We mounted 20 fresh porcine acetabula and 10 fresh human cadaver acetabula in the HEPFlEx-hip simulator and compared the two unipolar femur head hemi-endoprostheses (metal vs. ceramic). RESULTS: The mean friction coefficients against porcine acetabula were micro=0.017-0.082 for ceramic and micro=0.020-0.101 for metal; against human cadaver acetabula micro=0.017-0.083 for ceramic and micro=0.019-0.118 for metal. The frictional coefficient deltas (metal-ceramic) values of all measurements were Deltamicro=0.004 for porcine acetabula and Deltamicro=0.001 for cadaver acetabula. Box-plots graphics document significantly lower frictional coefficients of the ceramics. CONCLUSIONS: The lower frictional coefficients of ceramic compared to metal against fresh cadaveric acetabula may have a clinical impact on the process of the protrusion of the corresponding femoral head through the acetabulum.

Acetabulum↗

Frictional action at lower limb/prosthetic socket interface.

The frictional action at stump/socket interface is discussed by a simplified model and finite element model analyses and clinical pressure measurements. The friction applied to the stump skin produces stresses within tissue and these stresses may damage the tissues and affect their normal functions. The combination of normal and shear stresses is considered to be a critical factor leading to amputee's discomfort and tissue damage. However, friction at the stump/socket interface has a beneficial action. A simplified residual limb model and a finite element model using real geometry have been developed to analyse the support action of friction. Both results show that the friction plays a critical role both in supporting the load of the amputee's body during the support phase of the gait cycle and in preventing the prosthesis from slipping off the limb during swing phase. Pressure at the below-knee socket during walking were measured with conditions of different friction. The results reveal that a larger pressures was produced at the lubricated interface than at the normal interface. A proper choice of coefficient of friction will balance the requirements of relief of load stress and reduction of slip with the general ability to support loads.

Amputation Stumps↗

Surface sliding friction of negatively charged polyelectrolyte gels.

The friction between two polyelectrolyte gels carrying the same or opposite sign of charges has been investigated using a rheometer. It is found that the friction was strongly dependent on the interfacial interaction between two gel surfaces. In the repulsive interaction case, especially, the friction was extremely low. The friction behavior is attempted to be described in terms of the hydrodynamic lubrication of the solvent layer between two like-charged gel surfaces, which is formed due to the electrostatic repulsion of the two gel surfaces. From the theoretical analysis (hydrodynamic mechanism), the friction behaviors were explained qualitatively, all of the experimental results, nevertheless, could not be understood well. The viscoelastic feature of the gel and the non-Newtonian behavior of water at the friction interface are considered to be important to elucidate the gel friction.

Acrylamides↗

Effect of dental tool surface texture and material on static friction with a wet gloved fingertip.

Hand injuries are an important cause of pain and disability among dentists and dental hygienists and may be due to the high pinch forces involved in periodontal work. The pinch forces required to perform scaling may be reduced by increasing the friction between the tool and fingers. The purpose of this study was to determine whether modifying the tool material, surface texture, or glove type altered the coefficient of static friction for a wet gloved finger. Seven tools with varying surface topography were machined from 13 mm diameter stainless steel and Delrin and mounted to a 6-component force plate. The textures tested were a fine, medium and coarse diamond knurled pattern and a medium and fine annular pattern (concentric rings). Thirteen subjects pulled their gloved, wet thumb pad along the long axis of the tool while maintaining a normal force of 40 N. Latex and nitrile gloves were tested. The coefficient of static friction was calculated from the shear force history. The mean coefficients of static friction ranged from 0.20 to 0.65. The coefficient of static friction was higher for a smooth tool of Delrin than one of stainless steel. Differences in the coefficient of static friction were observed between the coarse and medium knurled patterns and the fine knurled and annular patterns. Coefficients of static friction were higher for the nitrile glove than the latex glove for tools with texture. These findings may be applied to the design of hand tools that require fine motor control with a wet, gloved hand.

Biomechanical Phenomena↗

Investigation into the effects of proteins and lipids on the frictional properties of articular cartilage.

The aim of this study was to investigate the effects of the proteins and the lipids on the frictional properties of articular cartilage in the mixed and boundary lubricating regimes. Bovine articular cartilage that had been treated to remove the lipids, and cartilage that had been treated to remove the proteins, from the surface layer were studied in order to investigate differences in their lubricating abilities. Tests were carried out on a sliding friction rig under contact pressures of 0.5 and 4 MPa. The results of the friction tests carried out under the 4 MPa contact pressure showed a slight increase in friction coefficient for both the lipid and the protein deficient cartilage when compared with the control cartilage. These differences were more apparent at the shorter loading times but none of the differences were found to be statistically significant. The tests at the lower contact pressure of 0.5 MPa showed that removing the lipids by washing the surface with detergent increased the friction coefficient at the shorter loading times but had no effect at the longer loading times. Digesting the cartilage with trypsin to remove the proteins from the surface layer had no effect on the friction coefficient at the shorter loading times but reduced the friction coefficient at the longer loading times. Both these results were confirmed with specimens that had both the lipids and the proteins removed from the surface layer.

Animals↗

Relative kinetic frictional forces between sintered stainless steel brackets and orthodontic wires.

The level of kinetic frictional forces generated during in vitro translation at the bracket-wire interface were measured for two sintered stainless steel brackets as a function of two slot sizes, four wire alloys, and five to eight wire sizes. The two types of sintered stainless steel brackets were tested in both 0.018-inch and 0.022-inch slots. Wires of four different alloy types, stainless steel (SS), cobalt chromium (Co-Cr), nickel-titanium (Ni-Ti), and beta-titanium (beta-Ti), were tested. There were five wire sizes for the 0.018-inch slot and eight wire sizes for the 0.022-inch slot. The wires were ligated into the brackets with elastomeric ligatures. Bracket movement along the wire was implemented by means of a mechanical testing instrument, and time dependent frictional forces were measured by a load cell and plotted on an X-Y recorder. For most wire sizes, lower frictional forces were generated with the SS of Co-Cr wires than with the beta-Ti or Ni-Ti wires. Increase in wire size generally resulted in increased bracket-wire friction. There were no significant differences between manufacturer for the sintered stainless steel brackets. The levels of frictional force in 0.018-inch brackets ranged from a low of 46 gm with 0.016-inch Co-Cr wire to a high of 157 gm with 0.016 x 0.025-inch beta-Ti wire. In comparing the data from a previous study by Kapila et al. 1990 performed at OUHSC with the same apparatus, the friction of sintered stainless steel brackets was approximately 40% to 45% less than the friction of the conventional stainless steel brackets.

Analysis of Variance↗

The effect of friction on the bending stiffness of orthodontic beams: a theoretical and in vitro study.

The purpose of this study was to investigate the effect of friction on the bending stiffness of orthodontic beams. A theoretical and experimental model have been established where tensile and compressive forces are applied to an arch wire to simulate the effect of additional friction during activation and deactivation, respectively. The results show that tensile force increases wire stiffness, and that compressive force increases flexibility. Thus more force will be needed during activation and more force will be lost during deactivation. The amount of force lost increases nearly linearly with increasing friction. During activation, the percentage increase in force due to friction for a given deflection is about equal to the loss of force due to friction during deactivation. Friction affects thin flexible wires more than heavy wires. Careful ligation is recommended in the leveling phase to reduce the negative side effects of friction.

Compressive Strength↗

Coefficient of friction: tribological studies in man - an overview.

BACKGROUND/PURPOSE: Compared to other studies of skin, relatively few studies have focused on the friction of skin. This work reviews existing skin friction, emphasizing test apparatuses and parameters that have added to information regarding the friction coefficient. This review also outlines what factors are important to consider in future friction studies. METHODS: Past studies have utilized numerous designs for a test apparatus, including probe geometry and material, as well as various probe motions (rotational vs. linear). Most tests were performed in vivo; a few were performed in vitro and on porcine skin. RESULTS: Differences in probe material, geometry and smoothness affect friction coefficient measurements. An increase in skin hydration, either through water or through moisturizer application, increases its friction coefficient; a decrease in skin hydration, either through clinical dermatitis or through alcohol addition, decreases the coefficient. Differences are present between anatomical sites. Conflicting results are found regarding age and no differences are apparent as a result of gender or race. CONCLUSION: Skin friction appears to be dependent on several factors - such as age, anatomical site and skin hydration. The choice of the probe and the test apparatus also influence the measurement.

Body Water↗

Friction produced by types of elastomeric ligatures in treatment mechanics with the preadjusted appliance.

The objective was to compare the frictional forces generated by new nonconventional passive elastomeric ligatures (NCL) and conventional elastomeric ligatures (CL) under dry conditions. An experimental model reproducing the right buccal segment of the upper arch and consisting of five stainless steel 0.022-inch preadjusted brackets (from the second premolar through the central incisor) was used to assess both static and kinetic frictional forces produced by NCL and CL. The frictional forces generated by the 0.019 x 0.025-inch stainless steel wire with the two types of elastomeric ligatures were recorded by sliding the wire into the aligned brackets. The friction produced by the 0.014-inch superelastic nickel titanium wire was evaluated both in the presence of aligned brackets and of three-mm misaligned canine bracket. The amount of both static and kinetic frictions were minimal (<10 g) in the NCL group in the presence of aligned brackets with both types of wires, whereas it ranged from a minimum of 95.6 g for the 0.014-inch superelastic nickel titanium wire to a maximum of 590.7 g for the 0.019 x 0.025-inch stainless steel wire when using CL. The amount of both static and kinetic frictions in the presence of a misaligned canine bracket in the NCL group were less than half of that shown by the CL group. A recently developed passive ligature system is able to produce significantly lower levels of frictional forces in vitro when compared with conventional elastomeric modules.

Elastomers↗

[Evaluation of orthodontic friction using a tribometer with alternating movement].

It is essential for orthodontists to control the complex phenomenon of friction. The in vitro techniques, usually dynamometers or tensile testing machines, used to measure the frictional resistance between arch wires and brackets are linear and unidirectional and can be criticised because tooth movements, such as tipping and uprighting, as well everyday oral activities, primarily chewing, are not uni-dimensional but more closely resemble the small amplitude oscillatory phenomena known as fretting. We therefore decided to develop a fretting machine not with linear but with alternating movements better suited to evaluate the frictional behaviour of orthodontic bracket-wire combinations. Once we had completed construction of this device, we proceeded to measure the frictional resistance between one stainless steel bracket (MicroArch GAC) and five wires currently used in orthodontics (Two nickel-titanium shape memory alloys: Neo Sentalloy and Neo Sentalloy with Ionguard GAC--Three titanium-molybdenum alloys: TMA and Low Friction TMA Ormco and Resolve GAC). We were able to set up a classification of the wires according to their coefficient of friction, demonstrating the inefficacy of ion implantation and quantifying the increase in the coefficient of friction which occurs when Resolve wires are placed in the oral environment for approximately one year.

Dental Alloys↗

Frictional behavior of stainless steel bracket-wire combinations subjected to small oscillating displacements.

In orthodontic treatment, sliding is frequently used to cause tooth movement. Inherent to this technique is the generation of a counteracting frictional force. In this pilot study, a fretting test consisting of reciprocating tangential displacements was used to investigate test parameters influencing frictional forces during sliding processes. Tests were run at a normal load of 2 N and a frequency of 1 Hz for tangential displacement strokes of 200 microm. Stainless steel orthodontic wires with cross-sections of .017 x .025 in (W17) and .018 x .025 in (W18), and brackets with slot sizes of .018 in (B18) and .022 in (B22) were used. A specific centered positioning method was developed to achieve a parallel alignment of the wire and the bracket slot. The experimental results indicated the significant role of the centered positioning method on the friction value. Implementation of the centered positioning method resulted in a friction force ranging from 0.89 N to 0.97 N at a 200 microm displacement amplitude and 1 Hz frequency, corresponding to a coefficient of friction ranging from 0.45 to 0.49 for the B18-W17 and the B22-W17 bracket-wire combinations, respectively. When the centered positioning method was not used, significantly higher values for the coefficient of friction were found for both bracket-wire combinations. The slot-filling, bracket-wire combinations (B18-W18 and B22-W22) resulted in an increased coefficient of friction and therefore are not recommended as sliding systems.

Analysis of Variance↗

Transfer of the horizontal patient: the effect of a friction reducing assistive device on low back mechanics.

Recognizing that the transfer of bedridden patients is associated with a high rate of low back injuries, various devices have been developed to assist with sparing the patient handlers. The purpose of this study was to quantify the friction-reducing ability of three different 'sliding' patient transfer devices together with the subsequent consequences on the low back loads of people performing the transfers. Coefficients of friction of the devices were determined by 'transferring' a standard object and a 'patient' over several surfaces common to a hospital setting. Then three participants performed controlled transfers with the various devices. Electromyography to measure muscle activation levels together with external forces and kinematic positional data were collected during push, pull and twist transfers. Spine loads were estimated with a three-dimensional biomechanical static link-segment model of the human body. Simply sliding a patient on a cotton sheet (control condition) produced a coefficient of friction of 0.45. The assistive devices substantially reduced friction by well over one-half (coefficients of 0.18 - 0.21). However, when using the devices the subjects adopted a variety of postures and techniques, such that there were no consistent influences on trunk inclination, low back compression or muscle activation profiles. Direct measurement of reduced friction between the bed and the patient with a friction-reducing device together with measurement of the back loads when actually transferring a patient formed a proof of principle. Specifically, while the device lowers friction, the transfer technique adopted by the lifter must be proper to reduce low back loading and any subsequent risks of back troubles associated with patient transfers. The direction of hand forces and torso position remains important.

Adult↗

A comparative study of the static and kinetic frictional resistance of titanium molybdenum alloy archwires in stainless steel brackets.

This ex vivo study compared the static and kinetic frictional resistance of eight different archwires tested in a single, stainless steel, zero base 0.022 x 0.028 inch (0.56 x 0.711 mm) slot standard edgewise bracket. The archwires evaluated were 0.019 x 0.025 inch (0.483 x 0.636 mm) in dimension, manufactured from the following alloys: beta titanium (TMA), 'low friction' coloured beta titanium (aqua, honeydew, purple and violet), ion-implanted beta titanium, Timolium and a stainless steel control. Prior to friction testing, bracket and archwire dimensions were measured by direct digital imaging via a desktop computer linked to a binocular light microscope. Frictional force was evaluated using an Instron universal testing machine. All experiments were carried out at room temperature, with no ligation, in the dry state with 20 degrees of added torque. The results demonstrated that static and kinetic friction were statistically significant (P < 0.001) for all archwire types. Ion-implanted and standard TMA archwires were found to have no significant advantage over stainless steel. The archwire alloys may be ranked as follows: stainless steel produced the lowest frictional resistance followed by honeydew, ion-implanted TMA and Timolium, with aqua, purple and violet producing frictional resistance values as high as standard TMA. It was also found that the percentage difference between the archwire and bracket slot dimensions claimed by the manufacturers and those measured in this experiment produced tolerances ranging from +5.37 to -6.67 per cent.

Analysis of Variance↗

The influence of resting periods on friction in the artificial hip.

Insufficient tribologic performance of total joint components is a major cause of prostheses failure. Wear has been studied intensively using testing machines that apply continuous motions. Human locomotion, however, is not well represented by continuous motions alone. Singular events and resting periods are a substantial part of daily activities. Resting does influence adhesion in the artificial joint with possible effects on friction, wear, and loosening. The current study evaluated the effects of resting on the frictional properties of hip prosthesis components. The activity measurements of 32 patients with artificial hip replacements were analyzed for resting durations of the hip. A pin-on-ball screening device was used to determine friction after characteristic resting periods and during continuous oscillating motion. All common articulation pairings were investigated. Prolonged and frequent resting periods of the hip were found for the patients. Initial friction increased with increasing resting duration for all tested materials (between 41% and 191%). The metal-on-metal articulations showed the highest friction level (0.098 for sliding) and the highest increase (191%) in friction with resting duration (0.285 after resting periods of 60 seconds). A high static frictional moment after resting periods might present a risk for aseptic implant loosening. Therefore, large head diameters of metal-on-metal joints should be used with caution, especially when additional unfavorable risk factors such as obesity, weak bone-implant interface, or high activity level are present.

Aged↗

Subjective scaling of smooth surface friction.

1. Six men and four women, 30-51 yr of age, were asked to use the tip of the washed and dried index finger to stroke six different featureless, flat surfaces mounted on a three-dimensional force platform. The six surfaces were rosin-coated glass, glass, satin-finished aluminum, poly-vinyl chloride (PVC) plastic, Teflon, and nyloprint (polyamide plastic). The subjects were requested to indicate where the sensation produced by each surface should be placed on an unidimensional scale represented by an 18cm line labeled at one end by the words "most slippery" and at the other end by the words "most sticky." The coefficients of friction for each surface and for each subject were subsequently assessed by asking each subject to stroke the surfaces as if they were assessing its slipperiness for 5 s. 2. The finger forces normal and tangential to the stroked surfaces were digitized at 250 Hz and stored on a laboratory computer. The ratio of the mean tangential force to the mean perpendicular force during stroking was used to calculate the mean coefficient of kinetic friction. The mean friction for all subjects ranged from 0.43 for the nyloprint surface to 2.79 for the rosin-coated glass. Correlation coefficients calculated between the subjective estimates of friction and the measured coefficients of friction for each subject individually resulted in a mean correlation of 0.85 (n = 10, P < 0.001). 3. These data indicate that subjects can accurately scale relative differences in the friction of macroscopically smooth, flat surfaces, by modulating the tangential force applied to the finger while keeping the normal force relatively constant. The fact that subjects maintained a relatively constant normal force and instead varied the tangential force across different surfaces suggests that receptors sensitive to these tangential forces are important in the perception of smooth surface friction.

Adult↗

A study of frictional forces between orthodontic brackets and archwires.

The differences in magnitude of static and kinetic frictional forces generated by 0.022 x 0.030-inch stainless steel (Dentaurum) and polycrystalline ceramic (Transcend) brackets in combination with archwires of different sizes (0.018 inch and 0.019 x 0.025 inch) and materials (stainless steel, nickel-titanium, and beta-titanium) at a constant ligature force were investigated. A friction-testing assembly using the Instron machine was used. In all cases, the static frictional force was greater than the kinetic frictional force. There were no significant differences in the frictional forces generated by stainless steel and polycrystalline ceramic brackets. Beta-titanium archwires produced greater frictional forces than the other two materials. Increasing the archwire diameter increased the frictional force.

Analysis of Variance↗

Scale effects on the attachment pads and friction forces in syrphid flies (Diptera, Syrphidae).

To test the role of constructional and dimensional factors in the generation of friction force by systems of setose attachment pads, six species of syrphid fly (Platycheirus angustatus, Sphaerophoria scripta, Episyrphus balteatus, Eristalis tenax, Myathropa florea and Volucella pellucens) were studied using light and scanning electron microscopy. Flies were selected according to their various body mass and attachment pad dimensions. Such variables as pad area, setal density, the area of a single setal tip and body mass were individually measured. A centrifugal force tester, equipped with a fibre-optic sensor, was used to measure the friction forces of the pads on a smooth horizontal surface made of polyvinylchloride. Friction force, which is the resistance force of the insect mass against the sum of centrifugal and tangential forces, was greater in heavier insects such as Er. tenax, M. florea and V. pellucens. Although lighter species generated lower frictional forces, the acceleration required to detach an insect was greater in smaller species. The area of attachment pads, setal tip area and setal density differed significantly in the species studied, and the dependence of these variables on body mass was significant. The frictional properties of the material of the setal tips were not dependent on the dimensions of the fly species. Similar results were obtained for the frictional properties of the pulvillus as a whole. Thus, the properties of the secretion and the mechanical properties of the material of the setal tips are approximately constant among the species studied. It is concluded that differences in friction force must be related mainly to variations in the real contact area generated by the pad on the smooth surface. The real contact area can be estimated as the summed area of the broadened setal tips of the pad in contact with the surface. The real contact area depends on such morphological variables as setal density and the area of a single setal tip. Although individual variables vary among flies with different dimensions, they usually compensate such that smaller setal tip area is partially compensated for by higher setal density.

Animals↗