Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Forensic Ballistics”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

A new type of shotgun ammunition produces unique wound characteristics.

The Tucson Police Department, Tucson, AZ, has begun using the Polyshok Impact Reactive Projectile (IRP), a new type of shotgun ammunition that includes a lead bead core that travels within single, plastic-encased projectile. On impact, the core is released to distribute over a small area, thereby disintegrating on impact to reduce the likelihood of exit or collateral damage on missed shots. After a brief review of shotgun slug ballistics and wound characteristics and a discussion of the mechanism of the Polyshok IRP, we report the first death in the United States from this ammunition. Findings included a single entrance wound with plastic ammunition components and small lead particles recovered from the body, the combination of which normally would suggest a close-range shooting with birdshot. However, the characteristics of this ammunition create different patterns than are found with slugs or shot, so that a medical examiner unfamiliar with the Polyshok IRP could draw inaccurate conclusions about ammunition and range of fire. Because the single projectile fired from this ammunition is composed of both plastic and lead, plastic components are likely to be found within the wound at any range of fire, unlike traditional shot or slug ammunition. Also, the small size of lead particles found spread through the wound cavity would ordinarily suggest a small-size shot, whereas the external appearance of the wound (a single entrance with no dispersion of shot) and the pattern of tissue destruction are more consistent with the patterns of injury associated with shotgun slugs.

Adult↗

Synchronization of the acoustic evidence in the assassination of President Kennedy.

We have revisited the acoustic evidence in the Kennedy assassination--recordings of the two Dallas police radio channels upon which our original NRC report (Ramsey NF et al., Report of the Committee on Ballistic Acoustics. National Research Council (US). Washington: National Academy Press, 1982. Posted at http://www.nap.edu/catalog/10264.html) was based--in response to the assertion by DB Thomas (Echo correlation analysis and the acoustic evidence in the Kennedy assassination revisited. Science and Justice 2001; 41: 21-32) that alleged gunshot sounds (on Channel 1), apparently recorded from a motorcycle officer's stuck-open microphone, occur at the exact time of the assassination (as established by emergency communications on Channel 2). We have critically reviewed these two publications, and have performed additional analyses. In particular we have used recorded 60 Hz hum and correlation methods to obtain accurate speed calibrations for recordings made on both channels, cepstral analysis to seek instances of repeated segments during playback of Channel 2 (which could result from groove jumping), and spectrographic and correlation methods to analyze instances of putative crosstalk used to synchronize the two channels. This paper identifies serious errors in the Thomas paper and corrects errors in the NRC report. We reaffirm the earlier conclusion of the NRC report that the alleged "shot" sounds were recorded approximately one minute after the assassination.

Acoustics↗

NIST bullet signature measurement system for RM (Reference Material) 8240 standard bullets.

A bullet signature measurement system based on a stylus instrument was developed at the National Institute of Standards and Technology (NIST) for the signature measurements of NIST RM (Reference Material) 8240 standard bullets. The standard bullets are developed as a reference standard for bullet signature measurements and are aimed to support the recently established National Integrated Ballistics Information Network (NIBIN) by the Bureau of Alcohol, Tobacco and Firearms (ATF) and the Federal Bureau of Investigation (FBI). The RM bullets are designed as both a virtual and a physical bullet signature standard. The virtual standard is a set of six digitized bullet signatures originally profiled from six master bullets fired at ATF and FBI using six different guns. By using the virtual signature standard to control the tool path on a numerically controlled diamond turning machine at NIST, 40 RM bullets were produced. In this paper, a comparison parameter and an algorithm using auto-and cross-correlation functions are described for qualifying the bullet signature differences between the RM bullets and the virtual bullet signature standard. When two compared signatures are exactly the same (point by point), their cross-correlation function (CCF) value will be equal to 100%. The measurement system setup, measurement program, and initial measurement results are discussed. Initial measurement results for the 40 standard bullets, each measured at six land impressions, show that the CCF values for the 240 signature measurements are higher than 95%, with most of them even higher than 99%. These results demonstrate the high reproducibility for both the manufacturing process and the measurement system for the NIST RM 8240 standard bullets.

Algorithms↗

Temporal cavity and pressure distribution in a brain simulant following ballistic penetration.

To study ballistic brain injury biomechanics, two common civilian full metal jacket handgun projectiles (25-caliber and 9-mm) were discharged into a transparent brain simulant (Sylgard gel). Five pressure transducers were placed at the entry (two), exit (two) and center (one) of the simulant. High-speed digital video photography (20,000 frames/second) was used to capture the temporal cavity pulsation. Pressure histories and high-speed video images were synchronized with a common trigger. Pressure data were sampled at 308 kHz. The 25-caliber projectile had an entry velocity of 238 m/s and exit velocity of 170 m/s. The 9-mm projectile had an entry velocity of 379 m/s and exit velocity of 259 m/s. Kinetic energies lost during penetration were 45.2 J for the 25-caliber projectile and 283.7 J for the 9-mm. Size of temporary cavities and pressures were dependent on projectile size and velocity. The 9-mm projectile created temporary cavities 1.5 times larger in size and lasted 1.5 times longer than the 25-caliber projectile. The 9-mm projectile had pressures three times higher than the 25-caliber projectile. Pressure differences between the center location and surrounding regions were approximately 1.4 times higher and lasted about 1.6 times longer in the 9- mm projectile than the 25-caliber projectile. Collapsing of the temporary cavity drew the brain simulant toward the center of the temporary cavity and created negative pressures of approximately -0.5 atmospheric pressure in the surrounding region. Pressures reached approximately +2 atmospheric pressure when temporary cavities collapsed. These quantified data may assist in understanding injury biomechanics and management of penetration brain trauma.

Biomechanical Phenomena↗

Detachment of the periosteum and soot staining of its underside in contact shots to the cerebral cranium.

Contact gunshot wounds are usually characterized by a muzzle imprint, a powder cavity ("pocket"), the presence of carboxyhemoglobin and often also stellate tears of the skin radiating from the bullet entrance hole. In shots to the cerebral cranium an additional sign may be observed around the bone defect: the periosteum is detached and reflected with soot on the underside. The frequency and possible causes of these periosteal findings are discussed on the basis of 68 contact gunshot wounds from forensic autopsy material and experimental shots fired against the frontal bone of a slaughtered calf.

Animals↗

A finite element model investigation of gunshot injury.

Multiple gunshot suicide can be a controversial subject mainly because of wrong opinions concerning immediate incapacitation or alleged backwards hurling. For the last 20 years, experts in medicine and physics have tried to demonstrate what really happens during a gunshot wound. Different methods have been used to achieve this aim such as basic physics or the use of empirical evidence. In this paper, using a finite element model of the human head, we demonstrate that no incapacitation or backwards hurling can occur from a gunshot fired between the eyes which did not enter the cerebrum.

Adult↗

Gunshot-related transport of micro-organisms from the skin of the entrance region into the bullet path.

The skin defect of a gunshot entrance wound is caused by the retrograde and anterograde displacement of skin particles. In the present study, we investigated whether gunshots to bacterially contaminated skin are associated with the transport of micro-organisms into the bullet path. The shots were fired into composite models of pig skin and gelatin blocks. The outer surface of the skin was covered with a thin layer of a defined bacterial suspension [green fluorescent protein-labelled Escherichia coli in the preliminary test and Staphylococcus epidermidis, DSM 1798, in the main test series]. After the bacterially contaminated fluid had dried, test shots were fired from a distance of 5 and 10 m using calibre .38 Special cartridges with different bullet types (round nose, truncated cone, hollow point and flat nose). Subsequent bacteriological analyses showed that all the bullet tracks in the gelatin serving as tissue simulant contained displaced micro-organisms from the skin surface. The results are presented and discussed with reference to the transport of skin particles into the depth of the wound track.

Animals↗

Tissue defect at the gunshot entrance wound: what happens to the skin?

To investigate the question what happens to the tissue lost at the entrance wound, experimental studies were performed on composite models consisting of dyed pig skin and gelatin blocks. For the test shots to the skin-gelatin preparations, cartridges calibre .38 spec. with different bullet types (round nose, hollow point, flat nose, truncated cone) were used. In all shots, a multitude of coloured skin particles were macroscopically discernible along the bullet tracks. In addition, small cell aggregations could be demonstrated microscopically even in those sections of the bullet paths which did not show skin fragments visible to the naked eye. The distribution of the skin particles showed certain peculiarities depending on the type of projectile.

Animals↗

Gunshot-related displacement of skin particles and bacteria from the exit region back into the bullet path.

In previous studies, it was shown that there is a gunshot-related transport of skin particles and microorganisms from the entrance region into the depth of the bullet path. The present study deals with the question of whether gunshots may also cause a retrograde transport of skin particles and microorganisms from the bullet exit region back into the bullet path. For this purpose, we used a composite model consisting of rectangular gelatin blocks and pig skin. The skin pieces were firmly attached to the gelatin blocks on the side where the bullet was to exit. Prior to the test shots, the outer surface of the pig skin was contaminated with a thin layer of a defined bacterial suspension. After drying the skin, test shots were fired from a distance of 10 m using cartridges calibre .38 spec. with different bullet types. Subsequent analyses showed that in all shots with full penetration of the composite model, the bullet path contained displaced skin particles and microorganisms from the skin surface at the exit site. These could be regularly detected in the distal 6-8 cm of the track, occasionally up to a distance of 18 cm from the exit hole. The distribution of skin particles and microorganisms is presented and the possible mechanism of this retrograde transport is discussed.

Animals↗

The determination of firing distance applying a microscopic quantitative method and confocal laser scanning microscopy for detection of gunshot residue particles.

In this study, we applied a microscopic quantitative method based on the use of sodium rhodizonate to verify the presence of residues and their distribution on the cutis of gunshot wounds. A total of 250 skin samples were selected from cases in which the manner of death (accidental, suicide, and homicide) and the shooting distance could be reliably determined. The samples were examined under a light microscope, in transmitted bright field illumination and phase contrast mode, and with confocal laser scanning microscopy. In all skin specimens the area of each histological section was directly measured by an image analysis system. Both the number and the size of powder particles were measured. The distribution of gunshot residues (GSR) in the epidermal and subepidermal layers was also analyzed. The evaluation of the microscopic entrance wounds demonstrated different findings related to the range of fire. The data derived from the evaluation of both macroscopic and microscopic features demonstrated that the amount and the spatial distribution of GSR deposits in the skin surrounding entrance wounds strictly correlate with shooting distance.

Case-Control Studies↗

Statistical inference and forensic evidence: evaluating a bullet lead match.

This experiment tested the ability of undergraduate mock jurors (N=295) to draw appropriate conclusions from statistical data on the diagnostic value of forensic evidence. Jurors read a summary of a homicide trial in which the key evidence was a bullet lead "match" that was either highly diagnostic, non-diagnostic, or of unknown diagnostic value. There was also a control condition in which the forensic "match" was not presented. The results indicate that jurors as a group used the statistics appropriately to distinguish diagnostic from non-diagnostic forensic evidence, giving considerable weight to the former and little or no weight to the latter. However, this effect was attributable to responses of a subset of jurors who expressed confidence in their ability to use statistical data. Jurors who lacked confidence in their statistical ability failed to distinguish highly diagnostic from non-diagnostic forensic evidence; they gave no weight to the forensic evidence regardless of its diagnostic value. Confident jurors also gave more weight to evidence of unknown diagnostic value. Theoretical and legal implications are discussed.

Female↗

A pilot study to measure the compressive and tensile forces required to use retractable intramuscular safety syringes.

BACKGROUND: A pilot study was conducted at the Tampa Veterans Administration Patient Safety Center. The objective was to determine the forces required to operate retractable safety syringes to evaluate potential adverse occupational health and patient safety issues. METHODS: Four brands (100 each) of retractable syringes were tested, using a digital force gauge, in air and in a simulated patient material (SPM). Compressive and tensile forces were measured while activating the retraction mechanism and withdrawing saline into the syringe barrel, respectively. RESULTS: The mean compressive force was greater in SPM than in air in all 4 devices. There was a statistically significant compressive force difference between activation in air and SPM in devices 1 and 2 (P </= .05). The tensile forces for all devices were lower than the compressive forces. Analysis of variance was used to compare the groups, and the results showed that the means were significantly different (P < .001). CONCLUSION: This pilot study has implications for device selection, training for users, design issues for manufacturers, and patient safety, as well as potential for future needlestick and ergonomic injuries. We recommend replication of this study with a computer-controlled force testing apparatus, and by testing multiple needle and syringe sizes.

Accidents, Occupational↗

Care of the critically ill patient with penetrating head injury.

Patients who have penetrating head injury all too often present with some of the most devastating and challenging intracranial injuries. The mechanisms of injury and associated neuropathology affect every body system and require a multidisciplinary approach. Evidence-based guidelines have been developed to offer some direction to clinicians involved in their care. Much remains scientifically unsubstantiated, however. Optimal management of critically ill patients who have penetrating head injury requires clinical expertise and care of the highest quality.

Diagnostic Imaging↗

The evaluation of a synthetic long bone structure as a substitute for human tissue in gunshot experiments.

Our goal was to compare experimental gunshot wounds in our non-biological bone model with similarly created wounds in swine bones, and evaluate the results. The design of the synthetic (polyurethane) bone was patterned after human bone structure, with a compact outer layer covering a porous inner layer. Ordnance gelatin, as substitute bone marrow, was injected into the bone's hollow core. To simulate the periostium, the bone was covered with a layer of latex. Then the bone was embedded in gelatin used to simulate surrounding soft tissue. For comparison, fresh swine bones were also embedded in gelatin, and fired upon under the same guidelines. All gunshots were high-speed filmed. In our experimental study, gunshot wounds to swine bones, and to our synthetic, non-biological bones were compared. The results (the comparison between the biological swine bones and the non-biological model bones) in regard to the following points are absolutely equal: the loss of velocity and energy after striking bone, bone fragmentation, bullet deformation, and the penetrating wound channel. Continuing studies with our synthetic bone model will bring about an even greater understanding of the mechanisms of "bullet-bone interaction". For this reason, we have extended our variety of bone models to include other skeletal structures such as skull, spine, pelvis and flat bones for further gunshot experiments.

Animals↗

Gunshot residue patterns on skin in angled contact and near contact gunshot wounds.

The goal of this study was the reproduction of shape and pattern of gunshot residues in near contact and contact gunshot wounds by a series of experimental gunshots on a skin and soft tissue model. The aim was to investigate the shape and direction of soot deposits with regard to the muzzle according to different muzzle-target angles, firing distances, type of ammunition and weapon and barrel length. Based on a review of the literature and on the results of the experiments the authors could make the following statements of gunshot residues in angled contact and close contact gunshot: (1) gunshot residues on the target surface can be differentiated in a "inner" and "outer powder soot zone"; (2) the outer powder soot zone is much less visible than the inner powder soot zone and may lack on human skin; (3) with increasing muzzle target distance both inner and outer powder soot halo increase in size and decrease in density; (4) in angled shots the inner powder soot halo shows an eccentric, elliptic shape which points towards the muzzle, regardless of ammunition, calibre and barrel length; (5) the outer powder soot points away from the muzzle in angled contact and close contact shots.

Animals↗

Popliteal artery bullet embolism in a case of homicide: a case report and review of the tangible literature.

Bullet embolism is a well known but a relatively rare phenomenon in common medicolegal autopsy practice. We present a homicide case of a bullet embolism to the left popliteal artery with interesting trajectory of projectile through the chest wall and right heart ventricle into the aortic lumen. Since in our presented case obvious homicidal manner of death was in question, discovery of bullet was an obligatory part of investigation in order to positively identify the responsible firearm. Detection of the missile transported through the circulation requires very thorough autopsy examination, especially if X-ray equipment is not available. As in all other cases in which initial bullet trajectory is changed in the body, the very important part of the medicolegal autopsy in cases accompanied with missile embolism, is to determine direction of the first part of the bullet's trajectory, because this indicates the position of the axis of the weapon barrel in the moment of firing (if there was no external ricochet), taking into consideration the posture of the victim and the location of the shooting person in the same moment. A review of the tangible literature is given.

Aorta, Thoracic↗

Three dimensional visualization and comparison of impressions on fired bullets.

Currently, optical devices, such as microscopes and CCD cameras, are utilized for identification of bullets and tool marks in the field of forensic science. While these optical methods are easily manageable and effective, they are under great influence of illumination condition. In other words, appearances of striations through these optical devices have possibility to be changed by lighting condition. Besides these appearance-based approaches, we can utilize three dimensional (3D) geometric data of tool marks that are free from lighting condition. In this study, we focused on 3D geometric data of landmark impressions on fired bullets for identification. We obtained the 3D surface data of tool marks by a confocal microscope and reconstructed virtual impressions on a PC monitor from the geometric data. Furthermore, the 3D data are exploited to numerical matching of two surface shapes. We also visualized the difference of two shapes. In order to do this, two surface models are aligned automatically. In this process, pairings of correspondent points on both surfaces are determined. Distance analysis between these pairs leads to a shape comparison. Since comparison results are visualized, they are intuitive and easily perceptive.

Algorithms↗