Determination of SO(2) in Wines Using a Flow Injection Analysis System with Potentiometric Detection.

This paper describes the development and application of a flow injection analysis system manifold comprising a gas diffusion unit and a potentiometric detector to the determination of free and total SO(2) in white and red wines. A homogeneous crystalline iodide double-membrane tubular electrode was used as detector. SO(2) determination based on the Ripper method was carried out by dosing the iodide formed in the oxidation of SO(2) with iodine, followed by the separation of the formed compound through a diffusion Teflon membrane. The results obtained from the analyses of free and total SO(2) in 30 wine samples showed good agreement between the proposed method and the rapid assay method recommended by the UE and OIV. The relative error deviations of the results obtained by both methods were <6%. This procedure is suitable for samples with approximately 3.2-180 mg L(-)(1) SO(2), performing determinations of 75-100 samples h(-)(1).

Journal Article↗

Determination of free (pH 2.2) sulfite in wines by flow injection analysis: collaborative study.

A method for the determination of free sulfite in wine by flow injection analysis (FIA) is described. The method involves liberation of sulfur dioxide from the wine at pH 2.2, with detection by decolorization of a malachite green solution. The method was collaboratively studied, and the results indicated an average reproducibility of 12% for white wine samples (average level 12.1 ppm SO2) and 26% for red wine samples (average level 3.1 ppm). When the FIA method was compared to an aeration/oxidation method, the results indicated a high degree of correlation between the 2 methods. The FIA method has been adopted by AOAC official first action.

Hydrogen-Ion Concentration↗

Amperometric assay of creatinine in urine by flow injection analysis based on conjugated reactions of immobilized enzymes. Simultaneous compensation of endogenous ammonia.

A flow-injection analysis biosensor system was developed for the amperometric assay of creatinine based on coupled reactions of three immobilized enzymes, using an oxygen electrode as the detection device. The ammonia produced by creatinine deiminase-catalyzed hydrolysis of creatinine was further converted into L-glutamate with two sequentially aligned enzyme reactors: glutamate dehydrogenase and glutamate oxidase. Endogenous ammonia was simultaneously compensated with a double peak recording system, where the flow was split after sample injection and rejoined before the glutamate dehydrogenase reactor. The system gave linear calibration in a range of 0.1-2.0 mM for creatinine and the first peak of ammonia, and 0.1-3.0 mM for the second peak of ammonia. One run was completed within two minutes. The system can be readily applied to the assay of creatinine in urine and showed good correlation with that from the currently used Jaffe method.

Amino Acid Oxidoreductases↗

Determination of acid values of fats and oils by flow injection analysis with electrochemical detection.

A new method using a flow injection system with electrochemical detection was developed to determine acid values of fats and oils. VK3 (2-methyl-1,4-naphthoquinone) solution, i.e., ethanol containing 3 mM VK3 and 38 mM LiClO4, was used as the carrier solution. Flow signals were monitored at -0.33 V vs. Ag/AgCl. For preparation of a sample solution, an oil sample was completely dissolved in VK3 solution, or fatty acids were extracted from the sample into this solution. Aliquots (5 microliters) of the sample solution were injected into the flow injection system. Acid values were determined based on flow signals for 14 samples and the results were found to be consistent with those by potentiometric titration. Relative standard deviation was less than 2%. Samples were processed at the rate of 60 h-1. The stability of fish and cod liver oils was followed by measuring acid values for 8 weeks. This method proved to be a simple and rapid means for acid value determination.

Acids↗

Spectrophotometric determination of urinary iodine by flow-injection analysis with on-line catalytic digestion.

A flow-injection technique involving on-line catalytic digestion and spectrophotometric detection has been developed for the determination of iodine in urine. After urine samples are digested by KMnO4-K2Cr2O7-H2SO4 solution, the iodine in the urine catalyzes the reaction of As(III) with Ce(IV). The remaining Ce(IV) is then reacted with brucine and the product is detected with a spectrophotometer at 480 nm. With this technique, we obtained a detection limit for urinary iodine of 0.039 mumol/L, and the linear range was 0.039-7.88 mumol/L with a CV < 3%. Analytical recovery ranged between 92% and 104% (mean 99%). The sampling frequency of the flow-injection technique was 70/h. We applied the method to measure the iodine concentration in a freeze-dried urine reference sample and in collected urine samples, and compared the results with those obtained by the accepted alkaline ashing technique. The proposed technique has the advantages of being simple, rapid, precise, accurate, and sensitive. It can be used to assess iodine-deficient populations as well as those receiving treatment.

Arsenic↗

Detection and characterization of phospholipase D by flow injection analysis.

A precisely working automated system for the investigation of phospholipases D (PLDs, EC 3.1.4.4) from plant and microbial sources with flow injection analysis (FIA) has been developed. The two versions of the FIA setup described are based on the oxidation of choline liberated from phosphatidylcholine by PLD action and catalyzed by choline oxidase and the chemiluminescence detection of hydrogen peroxide produced by this reaction. The correlation between this chemiluminescence signal and the PLD activity was linear in the range between 1 and 100 mU/ml PLD. The sampling frequency was 12 samples per hour. This method was used to compare three different PLDs from cabbage and microbial sources with respect to their pH optima, temperature stability, effectors, and v/[S]-characteristics.

Calcium↗

Pulse amperometric detection of salt concentrations by flow injection analysis using ionodes.

A sensitive novel approach of using an amperometric ion detector for the flow injection analysis of salts has been developed. The detection methodology is based on measuring the current associated with the transfer of ions across polarized microinterfaces between the aqueous sample solution and a 2-nitrophenyloctyl ether-poly(vinyl chloride) gel phase, referred to as ionodes. Different sodium salts of fluoride, chloride, bromide, nitrate, and sulfate were investigated. It was found that by employing an amperometric pulse detection mode and pure water as eluent, the detection limit of the ionode detector could be lowered to ppt level of salt concentrations under flowing conditions.

Journal Article↗

Determination of total CO2 in plasma by automated flow-injection analysis.

We describe a procedure for measuring total CO2 in plasma, based on the principles of the flow-injection analysis technique, which makes use of unsegmented fast-flowing reagent streams, as developed by Růziĉka and co-workers. The further methodological design resembles the silicone-rubber membrane technique of Kenny and Cheng. CO2 in the sample is released by reaction with H2SO4. Appropriate amounts of CO2 permeate through the membrane that separates the acid reagent streams and a buffered cresol-red indicator system. The experimental set-up and functioning of this system are described.

Autoanalysis↗

An in situ electrosynthesized amperometric biosensor based on lactate oxidase immobilized in a poly-o-phenylenediamine film: determination of lactate in serum by flow injection analysis.

The electrochemical immobilization of lactate oxidase in a poly-o-phenylenediamine film permits the one-step and all-chemical construction of a lactate amperometric biosensor. The sensor was prepared in situ i.e. in the flow injection analysis (FIA) system by simply injecting a plug of a solution containing the monomer and the enzyme. At a flow rate of 50 microL/min linearity was observed up to 0.2 mM lactate and detection limits of about 2 microM could be easily achieved. Faradaic interferences caused by ascorbate, urate, cysteine and acetaminophen were sufficiently minimized to permit lactate determination in diluted serum by FIA. Results obtained by FIA-amperometric detection compared well (according to a proper t-test at a 95% confidence level) with those obtained by a standard enzymatic colorimetric assay. At a flow rate of 1 ml/min a sample throughput higher than 70 sample h-1 was achieved. After one week of continuous use in the FIA system a 75% decrease in biosensor sensitivity was observed.

Animals↗

Simultaneous spectrofluorimetric determination of selenium (IV) and (VI) by flow injection analysis.

A simple, sensitive, highly selective, automatic spectrofluorimetric method for the simultaneous determination of selenium (IV) and (VI) as selenite-selenate by flow injection analysis (FIA) has been developed. The method is based on the selective oxidation of the non-fluorescent reagent 2-(alpha-pyridyl)thioquinaldinamide (PTQA) in acidic solution (1.5-3.0 M H2SO4) by SeIV to give an intensely fluorescent oxidation product (lambda ex =350 nm; lambda em = 500nm). Selenium (VI) is reduced on-line to SeIV, in a reduction coil installed in a photo-reactor, which is then treated with PTQA and the fluorescene due to the sum of SeIV and SeVI is measured; SeVi is determined from the difference in fluorescence values. Various analytical parameters, such as effect of acidity, flow rate, sample size, dispersion coefficient, temperature, reagent concentration and interfering species were studied. The photo-reduction conditions were optimized, with an FIA procedure, for SeVI on the basis of its reduction efficiency. The calibration graphs were rectilinear for 0.1-2.4 micrograms ml-1 of SeVI and 10 ng ml-1-2.2 micrograms ml-1 of SeIV, respectively. The method was applied to the determination of Se in several Standard Reference Materials (alloy, sediments and tea), as well as in some environmental waters (tap and surface water), food samples (flour and egg), a biological sample (human hair), soil sample and in synthetic mixtures. Up to 25 samples per hour can be analysed with an RSD approximately 0.1-2%.

Flow Injection Analysis↗

Semiautomatic determination of furanic aldehydes in food and pharmaceutical samples by a stopped-flow injection analysis method.

A kinetic study of the reactions of 5-hydroxymethyl-2-furfuraldehyde and furfural with 2-thiobarbituric acid (TBA) by a stopped-flow flow injection analysis technique has been undertaken. A semiautomatic method for the analytical determination of these furanic aldehydes is proposed on the basis of reaction with TBA. The proposed stopped-flow method was successfully applied to several commercial pharmaceutical preparations and food samples. The procedure is faster than the earlier procedure for determination of these compounds in foods and pharmaceuticals.

Calibration↗

Use of ionomer membranes to enhance the selectivity of electrode-based biosensors in flow-injection analysis.

The use of ionomer membranes to enhance the selectivity of potentiometric enzyme electrodes in flow-injection measurement arrangements is examined. The ionomer membranes employed are permeable to analyte substrates but relatively impermeable to detectable ions that would normally interfere with the measurement of the substrates if the enzyme electrodes were in direct contact with the sample. As a model system, the selectivity of enzyme electrodes prepared with nonactin-based ammonium-sensitive polymeric membranes is evaluated. In the preferred configuration, a thin hydrophilic anion-exchange membrane is incorporated within a flow-through dialysis unit upstream from the enzyme-electrode detector. As the sample passes through the dialysis unit, neutral or anionic analyte molecules (urea or glutamine) move through the membrane while the permeation of endogenous ammonium ions and other cations in the sample is retarded. A flowing recipient buffer on the other side of the membrane carries the analyte substrate to the enzyme-electrode detector. Enhancements in selectivity for analyte substrates over endogenous ammonium and potassium ions are greater than or equal to 9-fold when compared to enzyme-electrode flow-injection analysis (FIA) systems assembled without the ionomer membrane unit. The analytical utility of the proposed system is demonstrated by the accurate measurements of urea in blood serum and L-glutamine in hybridoma bioreactor media.

Biosensing Techniques↗

Determination of urinary glucose by a flow injection analysis amperometric biosensor and ion-exchange chromatography.

A practical biosensor system has been developed for the determination of urinary glucose using a flow-injection analysis (FIA) amperometric detector and ion-exchange chromatography. Glucose oxidase was immobilized onto porous aminopropyl glass beads via glutaraldehyde activation to form an immobilized enzyme column. On the basis of its negative charge at pH 5.5, endogenous urate in urine samples was effectively retained by an upstream anion-exchange resin column. The biosensor system possessed a sensitivity of 160 +/- 2.4 RU microM-1 (RU or relative unit is defined as 2.86 microV at the detection output) for glucose with a minimum detection level of 10 microM. When applied for the determination of urinary glucose, the result obtained compared very well with that of the widely accepted hexokinase assay. The immobilized glucose oxidase could be reused for more than 1000 repeated analyses without losing its original activity. The reuse of the acetate anion-exchange column before replacement would be about 25-30 analyses. Acetaminophen and ascorbic acid were also effectively adsorbed by the acetate anion exchanger. The introduction of this type of anion exchanger thus greatly improved the selectivity of the FIA biosensor system and fostered its applicability for the determination of glucose in urine samples.

Adult↗

The glutamate biosensor and its application to flow injection analysis system.

A micro-enzyme electrode was fabricated by cross-linking L-glutamate oxidase with glutaraldehyde on aminopropyl-platinized platinum wire. A flow injection analysis system with glutamate sensor was used for L-glutamate determination. The peak current is linearly related to the L-glutamate concentration in the range of 0.02-2.0 mM, with good performance, accuracy (CV = 0.4%), fast response (< 60s), and stability (> 20 days). The system was applied to determine the concentration of L-glutamate in a fermentation broth. The recovery rate was in the range of 98.7-107.5%.

Amino Acid Oxidoreductases↗

Improved flow injection analysis (FIA) method for determining selenium in biological samples, and the effect of captopril administration on selenium levels and glutathione peroxidase activity in rat.

An improved flow injection analysis (FIA) method has been developed for the determination of trace selenium in biological samples, and this method has been applied to investigate the effect of captopril, an antihypertensive drug having a thiol group, on selenium concentrations in the rat blood, liver and urine. After oral administration of captopril, selenium levels in the blood decreased, while those in the liver increased significantly. However, no pronounced effect was observed on the urinary excretion rate. The glutathione peroxidase activities in the blood and the liver were comparable to the changes in the selenium levels.

Administration, Oral↗

Flow-injection analysis for malondialdehyde in plasma with the thiobarbituric acid reaction.

A simple, precise, and rapid method to measure plasma malondialdehyde (MDA) was developed by use of solvent extraction--flow-injection analysis. The reagent solution, containing thiobarbituric acid (TBA), 5 g/L in 100 mL/L phosphoric acid, and extraction solvent (methylisobutyl ketone, MIBK) were propelled with a double-plunger micropump at a flow rate of 0.3 mL/min, and 20 microL of sample was introduced into the reagent stream. After TBA-MDA reactant was extracted into MIBK, the organic phase was continuously separated by a successive phase-separation system equipped with two phase separators, and the absorbance of the TBA-MDA reactant was measured at 532 nm. This approach resulted in excellent sensitivity, a CV of < 1.5%, a good correlation with the conventional manual method, and a sampling frequency of 7 samples/h, suggesting that this semiautomated method is suitable for measuring plasma MDA.

Animals↗

Colorimetric determination of free and total cholesterol by flow injection analysis with a fiber optic detector.

A flow injection method for the determination of total and free cholesterol is presented. Cholesterol esterase and cholesterol oxidase are immobilized on aminoalkyl glass beads. The beads are packed into a tubular glass reactor. The cholesterol esters traversing through the esterase reactor are cleaved to cholesterol and fatty acids. The oxidase reactor converts cholesterol to cholest-4-en-3-one and hydrogen peroxide is generated. The sample stream is merged with reagent streams consisting of a peroxidase solution and a solution of 2,2'-azino-bis-(3-ethyl-benzthiazoline-6-sulfonic acid) diammonium salt, and a hydrogen peroxide-dependent color reaction takes place in a short coiled reactor. The signal is monitored by means of fiber optic instrumentation. Cholesterol concentration can be related to the absorption of the oxidized dye form at a wavelength of 425 nm. The working range is 0.5-0.8 mmol l-1, and the sample throughputs are 60 and 30 h-1 for free and total cholesterol, respectively.

Cholesterol↗

Development of a flow injection analysis (FIA) immunosensor for the detection of Escherichia coli.

A flow injection immunoanalysis (FIA) system has been developed for the detection of Escherichia coli in artificially contaminated food samples. Anti-E. coli antibodies were covalently immobilized onto porous aminopropyl glass beads via glutaraldehyde activation to form an immunoreactor. After adsorption of the cells onto anti-E. coli antibody bound glass beads, 4-methylumbelliferyl-beta-D-glucuronide was injected into the system which was then hydrolyzed by the adsorbed E. coli cells containing beta-D-glucuronidase, an enzyme which is very specific to E. coli and to a few other strains of Shigella. Fluorescent 4-methylumbelliferone released from the enzymatic reaction was then detected by a fluorometer. Owing to the specificity of the antibody towards E. coli, the FIA system was very selective for detection of E. coli whereas Shigella boydii, another GUD-positive bacterium, did not give any response. The FIA system was successfully used for detecting as low as 5 x 10(7) CFU/ml E. coli in less than 30 min and was reusable for at least 300 repeated assays. The immunoreactor yielded reproducible results during 3 months of experimentation if stored overnight at 4 degrees C in carrier buffer containing 0.05 to 0.25% Tween 20.

Escherichia coli↗