Search PubMedSearch

SEARCH · Search PubMed

Results for “Deep sea”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

92 records · Page 6Linked to original sources

Transcranial Magnetic Stimulation for Patients with Exposure Therapy Resistant Obsessive-Compulsive Disorder (TETRO): Study Protocol for a Multicenter Randomized Controlled Trial.

BACKGROUND: Obsessive-compulsive disorder (OCD) is a disabling mental disorder, characterized by obsessions, compulsions, and substantial morbidity. Approximately 50% of adults with OCD fail to achieve satisfactory outcomes from first-line treatments, such as exposure therapy with response prevention (ERP), with or without medication. This leads to chronic social, educational, and occupational impairment. While invasive procedures such as deep brain stimulation are available for severe, treatment-refractory cases, a need remains for less invasive alternatives. Repetitive transcranial magnetic stimulation (rTMS), a noninvasive intervention, shows promise in reducing OCD symptoms. Unlike in depression, rTMS is not yet reimbursed for OCD in the Dutch healthcare system. OBJECTIVE: This study examines the efficacy and cost-effectiveness of low-frequency (1Hz) rTMS targeting the presupplementary motor area (pre-SMA) compared to sham rTMS as an adjuvant treatment to ERP in adults with OCD with inadequate response to first-line treatment. METHODS: A total of 250 adults with OCD will be enrolled in this multicenter randomized controlled trial. Participants will be randomly assigned to ERP combined with either active or sham 1Hz rTMS over the pre-SMA. Treatment is administered 4 times weekly for at least 5 weeks (20 rTMS-ERP sessions), with optional extension of 1 to 2 weeks, up to 28 rTMS-ERP sessions. Clinical assessments occur at baseline, weekly during treatment, posttreatment, and at 3, 6, and 12 months follow-up. Participants undergo pre- and posttreatment (functional) (MRI) scans, including a symptom provocation task. Blood sampling takes place pre- and posttreatment and at 3-month follow-up. The primary outcome is OCD severity at posttreatment, as measured by the Yale-Brown Obsessive-Compulsive Scale (Y-BOCS). Secondary outcomes include functional improvement, quality of life, and societal costs. Pretreatment symptom profiles, genotype, and brain network topology will be analyzed as predictors of response and relapse risk. Pre-to-post treatment change in blood-based and magnetic resonance (MR)-based neuroplasticity markers will help explore differential mechanisms between ERP alone and combined rTMS-ERP. We expect that the verum rTMS protocol will be cost-effective compared to sham-rTMS. RESULTS: Recruitment started in April 2022, and as of February 2026, 201 participants have been enrolled. Posttreatment assessments are projected to be completed in December 2026, with final one-year follow-up evaluations anticipated by the end of 2027. CONCLUSIONS: To our knowledge, this study is the first adequately powered randomized controlled trial examining efficacy, cost-effectiveness, and mechanism of action of rTMS for OCD as adjuvant therapy to ERP. In case of efficacy and/or cost-effectiveness, it will pave the way for rTMS as insured health care for adults with OCD in the Netherlands, and possibly other European countries. Furthermore, this trial will provide insight into the mechanisms of treatment response to intensive ERP, with and without adjunctive rTMS, as well as potential side effects, individual variability, and long-term outcomes in adults with OCD.

Humans

Artificial intelligence-assisted detection and optical differentiation of colorectal lesions in Lynch syndrome surveillance (CADLY2): a multicentre, open-label, randomised controlled superiority trial.

BACKGROUND: Artificial intelligence (AI)-based computer-aided detection (CADe) systems improve adenoma detection in average-risk colorectal cancer screening. Meanwhile, evidence in Lynch syndrome surveillance is sparse and inconsistent. We assessed the effect of CADe on adenoma detection during Lynch syndrome surveillance. Computer-aided optical diagnosis (CADx) performance for optical differentiation of colorectal lesions was evaluated as a secondary aim. METHODS: CADLY2 was an international, multicentre, open-label, randomised controlled superiority trial at nine specialised hereditary cancer surveillance centres in Belgium, Germany, the Netherlands, and Spain. Adults aged 18 years or older with genetically confirmed Lynch syndrome scheduled for surveillance colonoscopy were randomly assigned (1:1) to high-definition white-light (HD-WL) colonoscopy alone or to HD-WL colonoscopy with computer-aided assistance from CAD EYE (Fujifilm, Tokyo, Japan). CAD EYE was used for CADe during withdrawal and for CADx after lesion detection. Randomisation was done centrally through a secure web-based system using Pocock's minimisation algorithm with a stochastic component and was stratified by centre, sex, previous colorectal cancer, underlying pathogenic variant, and interval since previous colonoscopy. Allocation concealment was ensured through the centralised web-based system. Patients were masked to group allocation until the start of withdrawal in procedures with mild sedation, or until completion of the procedure in procedures with propofol-based sedation. Endoscopists were not masked. The primary outcome was adenoma detection rate, defined as the proportion of patients with at least one histopathologically confirmed adenoma, analysed in the full analysis set (defined as all randomly allocated patients with available data for the primary outcome). The diagnostic performance of the CADx system was evaluated as a secondary outcome. The safety analysis set comprised all randomly allocated patients who underwent a study colonoscopy. This study is registered with the German Clinical Trials Register, DRKS00030695, and is completed. FINDINGS: Between May 9, 2023, and Oct 30, 2025, 757 patients were randomly allocated to HD-WL colonoscopy (377 patients) or to AI-assisted colonoscopy (380 patients); 733 patients were included in the full analysis set (369 HD-WL and 364 AI-assisted). The median age was 49 years (IQR 38-59) in the HD-WL group and 50 years (38-59) in the AI-assisted group; 213 (58%) were female and 156 (42%) male in the HD-WL group, and 207 (57%) were female and 157 (43%) male in the AI-assisted group. The adenoma detection rate was 30·9% (114 of 369 patients) with HD-WL versus 33·8% (123 of 364 patients) with CADe assistance (odds ratio 1·14 [95% CI 0·83-1·57], p=0·41). For CADx differentiation of neoplastic versus non-neoplastic lesions in the paired lesion-level analysis, with histopathology as the reference standard and sessile serrated lesions and traditional serrated adenomas classified as non-neoplastic, CADx sensitivity was 85·9% (95% CI 82·0-89·1) and specificity was 91·4% (89·4-93·0). Three adverse events occurred in the AI-assisted group: two mild post-polypectomy bleedings and one serious pulmonary embolism or deep venous thrombosis unrelated to the procedure. No adverse events occurred in the HD-WL group. INTERPRETATION: CADe-assisted colonoscopy did not show the absolute improvement in adenoma detection rate that was assumed in the prespecified sample-size calculation. CADx did not clearly improve lesion differentiation beyond expert optical diagnosis in expert Lynch syndrome surveillance settings. FUNDING: Third-party research funding of the National Center for Hereditary Tumor Syndromes, University Hospital Bonn.

Humans