Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Deconvolution”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

Chiroptical detection during liquid chromatography: Deconvolution of overlapping peaks of enantiomers and its applications.

The peaks of enantiomers in liquid chromatography (LC) frequently overlap for different reasons. The experimental curve can be deconvolved, i.e., transformed into the two curves of the enantiomers, without any assumption concerning their peak shapes. Besides the usual photometric UV detection, resulting in absorbance A, polarimetric or circular dichroic detection is required, providing the rotation 90 degree angle alpha or the differential absorbance DeltaA, respectively. The accuracy of the ratio alpha/A or DeltaA/A for the pure enantiomers is essential for the quality of the deconvolution. The determination of these ratios, using the overlapping peaks, and the subsequent computer deconvolution of the latter are discussed in more detail than in the earlier publications, e.g. Ref. 1 concerning this particular method. The computer program developed for this purpose is characterized. A condition is given which limits the availability of ratios and, therefore, the possibility of deconvolution. Several novel examples are described which stem from the following fields of application of deconvolved peaks: actual optical purities during LC (on-line analysis), overall optical purity of a sample, purities of chromatographic peaks, and, finally, enantiomerization during LC.

Journal Article↗

Reblurred deconvolution method for chemical shift removal in F-19 (PFOB) MR imaging.

Perfluorocarbons such as perfluoroctylbromide (PFOB) can be used as contrast agents in the vascular system for fluorine-19 magnetic resonance imaging or as synthetic oxygen carriers. F-19 imaging has been proposed for studying the vascular system, capillary flow, tissue perfusion, and tumor oxygenation. A major difficulty is that F-19 compounds often have complex multipeak spectra. These peaks result in chemical shift artifacts, lower signal-to-noise ratios, and blurred images. Each peak also excites a different section when a section-select gradient is applied. Direct inverse filtering is the simplest deconvolution method for correcting such artifacts; however, two major difficulties present themselves: functional singularity and noise amplification at high frequencies. The use of a new reblurred deconvolution (RED) method appears to overcome these problems. Although this method is based on iterative deconvolution in the spatial domain, the computational overhead is negligible. Since the point spread function and object data are already available in the time domain as FID data, RED appears to be useful for eliminating chemical shift artifacts and suppressing noise amplification while restoring the original image without loss of resolution.

Contrast Media↗

Novel deconvolution method for linear pharmacokinetic systems with polyexponential impulse response.

A novel least-squares deconvolution method for estimating the rate and the extent of drug input into the systemic circulation is presented. The method is based on a polyexponential approximation of the impulse response and a polynomial approximation of the input rate. The method, which is readily implemented on a computer using any multiple linear regression program with a zero-intercept option, is compared to two other deconvolution methods using simulated data with various degrees of random noise added. It appears to have several significant advantages. The method is applied to plasma pentobarbital level data from oral and intravenous administration. The assumptions and limitations of deconvolution methods for analyzing drug input into the blood are discussed.

Absorption↗

A multidimensional deconvolution method for evaluating the absorption of drugs undergoing reversible metabolism and presystemic metabolite formation.

A general multidimensional deconvolution method is developed primarily for application to the bioavailability assessment of drugs with reversible metabolism. The proposed approach involves fitting continuous functions to the experimental data and then applying a numerical deconvolution algorithm to the fitted curves. It is shown how the method may be used to determine the rates and extends of drug absorption and presystemic formation of interconversion metabolites. The proposed method is implemented as a FORTRAN subroutine called DCVSYS for the general multidimensional deconvolution problem involving any continuous functions and as a user-friendly PC-compatible program called NDCREV for evaluating the absorption of drugs undergoing reversible metabolism. The methods and computer programs are demonstrated by application to simulated drug and metabolite concentrations for a drug with reversible metabolism.

Absorption↗

A computational strategy for the deconvolution of NMR spectra with multiplet structures and constraints: analysis of overlapping 13C-2H multiplets of 13C enriched metabolites from cell suspensions incubated in deuterated media.

A computational strategy for the deconvolution of complex spectra involving scalar multiplet patterns is presented. This approach fits spectra that can be composed of single resonances as well as scalar coupling multiplets for which resonance frequencies, intensities, and lineshape parameters can be optimized. For multiplets, the coupling constant also is optimized. Any external information about the optimizable parameters can be taken into account as external constraints. A lineshape described by absorptive and dispersive Lorentzian and Gaussian contributions and the baseline with up to 40 Fourier and polynomial terms can likewise be optimized. The effectiveness of the procedure is assessed on the basis of computer simulated deconvolutions of a composite of 1J(13C-2H) multiplets arising from a mixture of all possible 13C-2H isotopomers of deuterated L-[3-13C]lactate generated from cell preparations incubated with D-[1-13C]glucose in D2O, which was analyzed previously with a manual deconvolution procedure (R. Willem, M. Biesemans, F. Kayser, W. J. Malaisse, Magn, Reson. Med. 31, 259-267 (1994)). The use of constraints is shown to lead to an improvement in the results. The fitting strategies and the importance of the baseline as an origin of bias are discussed.

Carbon Radioisotopes↗

Iterative blind deconvolution in magnetic resonance brain perfusion imaging.

In first pass magnetic resonance brain perfusion imaging, arterial input functions are used in the deconvolution of the observed contrast concentrations to obtain quantitative hemodynamic parameters. Ideally, arterial input functions should be measured in each imaged voxel to eliminate the effects of delay and dispersion of the contrast agent from the injection site. An approach based on iterative blind deconvolution with the Richardson-Lucy algorithm is proposed for the simultaneous estimation of voxel-specific arterial input functions and voxel-specific tissue residue functions. An extended contrast concentration model was used to separate the first pass bolus from additional recirculation and leakage signals. The extended model was evaluated using in vivo data. Computer simulations examined the feasibility of iterative blind deconvolution in perfusion imaging. Preliminary in vivo results from a patient with fibromuscular dysplasia showed territories with delayed/dispersed arterial input functions that coincided with the location of territories supplied by collateral circulation as described from the complete radiologic examination. Higher flow values and shorter mean transit times compared to conventional methods were obtained in these areas, suggesting that the effects of dispersion were minimized. The in vivo estimated arterial input functions visualized the patient's blood supply patterns as a function of time.

Adult↗

Deconvolution-interpolation gridding (DING): accurate reconstruction for arbitrary k-space trajectories.

A simple iterative algorithm, termed deconvolution-interpolation gridding (DING), is presented to address the problem of reconstructing images from arbitrarily-sampled k-space. The new algorithm solves a sparse system of linear equations that is equivalent to a deconvolution of the k-space with a small window. The deconvolution operation results in increased reconstruction accuracy without grid subsampling, at some cost to computational load. By avoiding grid oversampling, the new solution saves memory, which is critical for 3D trajectories. The DING algorithm does not require the calculation of a sampling density compensation function, which is often problematic. DING's sparse linear system is inverted efficiently using the conjugate gradient (CG) method. The reconstruction of the gridding system matrix is simple and fast, and no regularization is needed. This feature renders DING suitable for situations where the k-space trajectory is changed often or is not known a priori, such as when patient motion occurs during the scan. DING was compared with conventional gridding and an iterative reconstruction method in computer simulations and in vivo spiral MRI experiments. The results demonstrate a stable performance and reduced root mean square (RMS) error for DING in different k-space trajectories.

Algorithms↗

Deconvolution of the circular dichroism spectra of proteins: the circular dichroism spectra of the antiparallel beta-sheet in proteins.

A recently developed algorithm, called Convex Constraint Analysis (CCA), was successfully applied to determine the circular dichroism (CD) spectra of the pure beta-pleated sheet in globular proteins. On the basis of X-ray diffraction determined secondary structures, the original data set used (Perczel, A., Hollosi, M., Tusnady, G. Fasman, G.D. Convex constraint analysis: A natural deconvolution of circular dichroism curves of proteins, Prot. Eng., 4:669-679, 1991), was improved by the addition of proteins with high beta-pleated sheet content. The analysis yielded CD curves of the pure components of the main secondary structural elements (alpha-helix, antiparallel beta-pleated sheet, beta-turns, and unordered conformation), as well as a curve attributed to the "aromatic contribution" in the wavelength range of 195-240 nm. Upon deconvolution the curves obtained were assigned to various secondary structures. The calculated weights (percentages determining the contributions of each pure component curve in the measured CD spectra of a given protein) were correlated with the X-ray diffraction determined percentages in an assignment procedure and were evaluated. The Pearson product correlation coefficients (R) are significant for all five components. The new pure component curves, which were obtained through deconvolution of the protein CD spectra alone, are promising candidates for determining the percentages of the secondary structural components in globular proteins without the necessity of adopting an X-ray database. The CD spectrum of the CheY protein was interesting because it has the characteristic shape associated with the alpha-helical structure, but upon analysis yielded a considerable amount of beta-sheet in agreement with the X-ray structure.

Circular Dichroism↗

Reference deconvolution in the frequency domain.

Reference deconvolution, i.e., using the lineshape distortions of a reference signal with known ideal shape to deduce a correction function for the whole spectrum, is normally performed in the time domain. As a disadvantage, reference signals of higher multiplicity cannot be employed because of mathematical instabilities. In this work we show that these difficulties can be circumvented by carrying out reference deconvolution in the frequency domain. The computational demands of this approach are higher, but not prohibitive, because the width of the correction function is only a fraction of that of the whole spectrum. An iterative algorithm was implemented that yields the optimum widths of the correction function and of the ideal reference signal. Singular value decomposition was found to produce better results than LU decomposition of the design matrix. The feasibility of the deconvolution method and of the algorithm are demonstrated using both synthetic and experimental data.

Algorithms↗

Deconvolution in 3-D optical microscopy.

Fluorescent probes are becoming ever more widely used in the study of subcellular structure, and determination of their three-dimensional distributions has become very important. Confocal microscopy is now a common technique for overcoming the problem of out-of-focus flare in fluorescence imaging, but an alternative method uses digital image processing of conventional fluorescence images--a technique often termed 'deconvolution' or 'restoration'. This review attempts to explain image deconvolution in a non-technical manner. It is also applicable to 3-D confocal images, and can provide a further significant improvement in clarity and interpretability of such images. Some examples of the application of image deconvolution to both conventional and confocal fluorescence images are shown.

DNA↗

An algorithm and computer program for deconvolution in linear pharmacokinetics.

The procedure of deconvolution to evaluate the rate and the extent of input from absorption data and data from intravenous administration is the most fundamental and least assumptive method of accurately evaluating drug absorption in linear pharmacokinetics. It is shown for linear systems that if the absorption response and the response from an intravenous infusion or bolus administration are both well approximated by a polyexponential function, then the rate of absorption can be expressed as a sum of exponentials. An algorithm and computer program are presented whereby the absorption function is uniquely defined from the model-independent parameters of the polyexponential expressions fitted to the absorption data and data from intravenous administration. Fitting a sum of exponentials to data has become a routine procedure in pharmacokinetics. The method presented therefore makes the previously complex task of deconvolution a simple procedure. The deconvolution approach is discussed in relation to conventional methods of evaluating drug absorption and appears to have some distinct advantages over these methods. The method is tested using simulated data and demonstrated using pentobarbital and cimetidine data from human subjects.

Absorption↗

A polyexponential deconvolution method. Evaluation of the "gastrointestinal bioavailability" and mean in vivo dissolution time of some ibuprofen dosage forms.

A new deconvolution algorithm (DCON) suitable for pharmacokinetic applications is presented. It requires that both the impulse and input responses, typically systemic drug levels, be well described by polyexponential equations. DCON has a wider range of applications than an earlier method (DECONV) from which it is derived. A FORTRAN program is provided, making implementation of the technique a simple matter. DCON is demonstrated to evaluate the "GI bioavailability," defined as the rate and the extent of gastrointestinal drug release, of various ibuprofen dosage forms. The GI drug release kinetics exemplifies a pharmacokinetic system which cannot be evaluated using the previous deconvolution algorithm (DECONV) because of an initial zero drug level response. This limitation is not found in DCON. It is also demonstrated how the mean in vivo dissolution time MDT can be evaluated by deconvolution.

Biological Availability↗

Impulse response model in reconstruction of insulin secretion by deconvolution: role of input design in the identification experiment.

Insulin secretion rate (ISR) in vivo can be reconstructed by deconvolution of plasma concentration of C-peptide (CP), a peptide co-secreted with insulin but not extracted by the liver and exhibiting linear kinetics. Deconvolution requires the knowledge of the CP impulse response. A two exponential model is usually chosen to describe the CP impulse response but three exponential and one exponential models have also been used. The purpose of this paper is to investigate the role of the CP impulse response model order in reconstructing ISR by deconvolution in three standard physiological/clinical situations: ultradian oscillations, rapid pulses, and biphasic response to a glucose stimulus. By resorting to simulation, we first show that, in each situation, the validity of impulse response models with different orders depends on the input chosen in the impulse response identification experiment. Real data are then used which support the simulation results.

Activity Cycles↗

Quantitative depth profiling in glow discharge spectroscopies - A new deconvolution technique to separate effects of an uneven erosion crater shape.

An algorithm is presented as a concept for the quantification in direct current and radiofrequency glow discharge (GD) modes for GD optical emission spectroscopy. The algorithm is divided into excitation and sputtering part and thus it is possible to distinguish between the different excitation processes and to consider equivalent sputtering crater formations in both modes. Intensity-time profiles are affected corresponding to the method by several effects. One important effect is that sputtering occurs at a single time in different depths because of curved crater bottoms, this is usually called crater effect. The main purpose is to introduce an iterative deconvolution technique which for the quantification numerically takes into account the curved sputtering crater bottom. Input data for the deconvolution technique are the calibrated mass-time profile, the partial densities of the sample constituents and the measured final shape of the sputtering crater. Using a relatively simple model for ion sputtering the deconvolution technique improves iteratively the calculated layer structure by means of information on crater formation. The mathematical handling is illustrated for the quantification of a depth profile of a multilayer sample of ten 100 nm layers. The resulting concentration-depth profile reflects excellently the real elemental distribution of the multilayer system.

Journal Article↗

Deconvolution method for accurate determination of overlapping peak areas in chromatograms.

A method is described for deconvoluting chromatograms which contain overlapping peaks. Parameters can be selected to ensure that attenuation of peak areas is uniform over any desired range of peak widths. A simple extension of the method greatly reduces the negative overshoot frequently encountered with deconvolutions. The deconvoluted chromatograms are suitable for integration by conventional methods.

Chromatography↗

Quantitative scintigraphy with deconvolutional analysis for the dynamic measurement of hepatic function.

A mathematical technique known as deconvolutional analysis was used to provide a critical and previously missing element in the computations required to quantitate hepatic function scintigraphically. This computer-assisted technique allowed for the determination of the time required, in minutes, of a labeled bilirubin analog (99mTc-disofenin) to enter the liver via blood and exit via bile. This interval was referred to as the mean transit time (MTT). The critical process provided for by deconvolution is the mathematical simulation of a bolus injection of tracer directly into the afferent blood supply of the liver. The raw data required for this simulation are obtained from the intravenous injection of labeled disofenin, a member of the HIDA family of radiopharmaceuticals. In this study, we perform experiments which document that the simulation process itself is accurate. We then calculate the MTT under a variety of experimental conditions involving progressive hepatic ischemia/reperfusion injury and correlate these results with the results of simultaneously performed BSP determinations and hepatic histology. The experimental group with the most pronounced histologic findings (necrosis, vacuolization, disorganization of hepatic cords) also have the most prolonged MTT and BSP half-life. However, both quantitative imaging and BSP testing are able to identify milder degrees of hepatic ischemic injury not reflected in the histologic evaluation. Quantitative imaging with deconvolutional analysis is a technique easily adaptable to the standard nuclear medicine minicomputer. It provides rapid results and appears to be a sensitive monitor of hepatic functional disturbances resulting from ischemia and reperfusion.

Animals↗

An iterative method for the deconvolution of microcalorimeter thermograms.

An iterative method for the deconvolution of microcalorimetry thermograms suitable for small digital computers is presented. The method employs a measured impulse response function directly as the deconvolution kernel, thus explicit system simulation is not required. Data are presented showing the performance of the method and the exchange of signal-to-noise ratio for time resolution that is made when deconvolution techniques are employed. An improvement in the system time resolution of fifty times is demonstrated with measured data.

Algorithms↗

WENDEC: a deconvolution program for processing hormone time-series.

The estimation of the glandular secretory rate from time-series of hormone concentration in plasma can be formulated as a deconvolution problem. In particular, the paper addresses the analysis of frequently sampled data collected in order to study spontaneous pulsatile secretion. Standard deconvolution methods do not allow for the non-negativity constraint and the presence of high-frequency components in the secretory rate. In order to overcome the intrinsic ill-conditioning of the problem, the maximum entropy method is used to obtain a probabilistic representation of the prior knowledge concerning the unknown secretory signal, thus leading to a White Exponential Noise (WEN) model. The deconvolution problem is then posed within a Bayesian framework and solved by means of Maximum-A-Posteriori estimation. The program that implements the algorithm handles non-negativity constraints, provides confidence intervals, and is computationally and memory efficient.

Algorithms↗