Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Coriolis Force”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

Infrared and Raman spectra, ab initio calculations of structure and vibrational assignment of 1-fluoro-2-butyne.

The infrared spectra (3500-50 cm(-1)) of the gas and solid and the Raman spectra (3500-50 cm(-1)) of the liquid and solid have been recorded for 1-fluoro-2-butyne, CH3-C-triple bond-C-CH2F. Equilibrium geometries and energies have been determined by ab initio and hybrid DFT methods using a number of basis sets. A vibrational assignment is proposed based on the force constants, relative intensities, depolarization ratios from the ab initio and DFT calculations and on vibrational-rotational band contours obtained using the calculated equilibrium geometries. From calculated energies it is shown that the CH3 group exhibits almost completely free rotation which is in agreement with the observation of Coriolis sub-band structure in two of the degenerate methyl vibrations. The results are compared to the corresponding quantities for some similar molecules.

Coriolis Force↗

Spatial orientation and balance control changes induced by altered gravitoinertial force vectors.

To better understand the mechanisms of human adaptation to rotating environments, we exposed 19 healthy subjects and 8 vestibular-deficient subjects ("abnormal"; four bilateral and four unilateral lesions) to an interaural centripetal acceleration of 1 g (resultant 45 degrees roll-tilt of 1.4 g) on a 0.8-m-radius centrifuge for periods of 90 min. The subjects sat upright (body z-axis parallel to centrifuge rotation axis) in the dark with head stationary, except during 4 min of every 10 min, when they performed head saccades toward visual targets switched on at 3- to 5-s intervals at random locations (within +/- 30 degrees) in the earth-horizontal plane. Eight of the normal subjects also performed the head saccade protocol in a stationary chair adjusted to a static roll-tilt angle of 45 degrees for 90 min (reproducing the change in orientation but not the magnitude of the gravitoinertial force on the centrifuge). Eye movements, including voluntary saccades directed along perceived earth- and head-referenced planes, were recorded before, during, and immediately after centrifugation. Postural center of pressure (COP) and multisegment body kinematics were also gathered before and within 10 min after centrifugation. Normal subjects overestimated roll-tilt during centrifugation and revealed errors in perception of head-vertical provided by directed saccades. Errors in this perceptual response tended to increase with time and became significant after approximately 30 min. Motion-sickness symptoms caused approximately 25% of normal subjects to limit their head movements during centrifugation and led three normal subjects to stop the test early. Immediately after centrifugation, subjects reported feeling tilted 10 degrees in the opposite direction, which was in agreement with the direction of their earth-referenced directed saccades. Postural COP, segmental body motion amplitude, and hip-sway frequency increased significantly after centrifugation. These postural effects were short-lived, however, with a recovery time of several postural test trials (minutes). There were also asymmetries in the direction of postcentrifugation COP and head tilt which depended on the subject's orientation during the centrifugation adaptation period (left ear or right ear out). The amount of total head movements during centrifugation correlated poorly or inversely with postcentrifugation postural stability, and the most unstable subject made no head movements. There was no decrease in postural stability after static tilt, although these subjects also reported a perceived tilt briefly after return to upright, and they also had COP asymmetries. Abnormal subjects underestimated roll-tilt during centrifugation, and their directed saccades revealed permanent spatial distortions. Bilateral abnormal subjects started out with poor postural control, but showed no postural decrements after centrifugation, while unilateral abnormal subjects had varying degrees of postural decrement, both in their everyday function and as a result of experiencing the centrifugation. In addition, three unilateral, abnormal subjects, who rode twice in opposite orientations, revealed a consistent orthogonal pattern of COP offsets after centrifugation. These results suggest that both orientation and magnitude of the gravitoinertial vector are used by the central nervous system for calibration of multiple orientation systems. A change in the background gravitoinertial force (otolith input) can rapidly initiate postural and perceptual adaptation in several sensorimotor systems, independent of a structured visual surround.

Acceleration↗

The influence of gravitoinertial force level on oculomotor and perceptual responses to sudden stop stimulation.

Our goal was to determine whether the vestibular response to vertical, z-axis body rotation in the dark is influenced by the magnitude of gravitoinertial force. We measured the nystagmus and the duration of illusory self-motion elicited in blindfolded subjects by cessation of such rotation during the free-fall, high, and terrestrial force phases of parabolic flight maneuvers. Both measures were significantly lower in zero G than in 1 G, and lower to a smaller extent in 1.8 G. The decreased intensity of nystagmus was due specifically to a decrease in the time constant of slow phase velocity decay with no decrement in peak velocity. This pattern of findings is consistent with the responses we had observed earlier to constant levels of Coriolis, cross-coupled stimulation during parabolic flight maneuvers both in terms of the mode of nystagmus suppression and the effect of G-level. Attenuation of the vestibular response to rotary acceleration in free-fall causes sensory-motor mismatches during natural head movements in orbital flight that may be important factors in the evocation of space motion sickness.

Coriolis Force↗

Ground simulation of the G-excess illusion.

Objective. To observe the subjects' perception of orientation following certain head movements or change of simulator cab attitude in hypergravity (HG), and assess the feasibility of simulating G-excess illusion on the ground by a centrifuge-like Spatial Disorientation (SD) simulator. Method. 1.6 G force field was generated by planetary rotation of the simulator. Perception of orientation of the cab were collected from twelve male pilots' report following their heads pitch movements in pitch plane or cab attitude changes in roll plane under 1.6 G. Result. While making a pitch-up head movement, the pilots experienced a 63.8 degrees +/- 48.3 degrees pitch-up attitude change of the cab in pitch plane, and when the cab was tilted left 20 degrees, pilots experienced a tilt-left perception of 48.6 degrees +/- 39.4 degrees in roll plane. Conclusion. Although there's strong Coriolis effects onboard the SD simulator under 1.6 G, most pilots experienced the G-excess illusion. It demonstrated that it was feasible to use the centrifuge-like device to generate this kind of illusion on the ground.

Adult↗

Infrared and Microwave Spectra and Force Field of DBO: The Coriolis Interaction between the nu1 and nu2 + nu3 States.

The nu1 and nu3 bands of D11BO and the nu1 band of D10BO were observed by using an infrared diode laser spectrometer. The DBO molecule was generated by an ac discharge in a mixture of BCl3, D2, O2, and He. As inferred previously, a strong Coriolis interaction was in fact found to take place between the nu1 and nu2 + nu3 states, and an analysis of the observed nu1 spectra, which explicitly took into account this Coriolis interaction, predicted the pure rotational transition frequencies of DBO in the nu1 state. Pure rotational lines were then detected by microwave spectroscopy, confirming the validity of the infrared assignment. In the microwave experiment DBO molecules were generated by a discharge in a mixture of B2D6 and O2. The three fundamental bands and a hot band of D11BO, as well as the nu1 and nu3 bands of D10BO, were subsequently recorded in emission with a Fourier transform infrared spectrometer. DBO molecules were generated by the reaction of D2 with HBO at temperatures above 800 degreesC in a ceramic tube furnace. All of the observed spectra were simultaneously subjected to a least-squares analysis to obtain molecular parameters in the ground, nu1, nu2, nu3, and nu2 + nu3 states. The results thus obtained improved the force field and molecular structure of the HBO/DBO molecules reported in a previous study (Y. Kawashima, Y. Endo, and E. Hirota, 1989, J. Mol. Spectrosc. 133, 116-127). Copyright 1998 Academic Press.

Journal Article↗

Sensation and action during active and passive movement.

In order to determine the cause of active or passive sensation and action, we studied the effect of perception on gaze and posture control. Normal adults and a patient with bilateral labyrinthine loss underwent whole body rotation seated in a chair (120 degrees/s) or standing on a platform (60 degrees/s), while tilting their head with their vision normal or covered. Eye movements were recorded by a CCD video camera and body sways by a force platform. In normal subjects, gaze and posture became ataxic when head tilting with their vision covered, but they remained skilled under conditions of normal vision. The patient with bilateral labyrinthine loss did not undergo the effect of head tilting with no vision. It seems likely that sensation and action, whether they are skilled or ataxic, are controlled by the perception of an outer world which is integrated from visual and vestibular inputs and functions as a vector in the head.

Adult↗

Evidence for positive force feedback during involuntary aftercontractions.

We examined the involuntary isotonic muscle aftercontraction which follows a 1-min voluntary contraction at 60% of maximum voluntary force. Aftercontractions provide a unique paradigm for investigating the automatic postural control of the upper limb in man. Previous work has shown that the strength of these contractions in m. deltoid is linearly dependent on the inclination of the subject's body in the gravitational field. The current experiments were designed to test if this was due to the gravitational loading on the arm as this also changes with body inclination. The subject sat with the head stationary to prevent changes in vestibular orientation. Aftercontractions in m. deltoid were evoked with the normal weight of the arm present and also with arm loadings equal to 0, 25, 50 and 75% of this value. These reductions were produced by a counter lever apparatus. The results showed that the EMG amplitude of this involuntary contraction depended linearly on the loading of the arm. This is interpreted as being the result of positive load feedback. Aftercontraction EMG amplitude at 100% load was 2.7 times greater than at 0% load. The results are discussed in the context of recent work on positive load feedback in man and animals.

Adult↗

Artificial gravity as a countermeasure in long-duration space flight.

Long-duration exposure to weightlessness results in bone demineralization, muscle atrophy, cardiovascular deconditioning, altered sensory-motor control, and central nervous system reorganizations. Exercise countermeasures and body loading methods so far employed have failed to prevent these changes. A human mission to Mars might last 2 or 3 years and without effective countermeasures could result in dangerous levels of bone and muscle loss. Artificial gravity generated by rotation of an entire space vehicle or of an inner chamber could be used to prevent structural changes. Some of the physical characteristics of rotating environments are outlined along with their implications for human performance. Artificial gravity is the centripetal force generated in a rotating vehicle and is proportional to the product of the square of angular velocity and the radius of rotation. Thus, for a particular g-level, there is a tradeoff between velocity of rotation and radius. Increased radius is vastly more expensive to achieve than velocity, so it is important to know the highest rotation rates to which humans can adapt. Early studies suggested that 3 rpm might be the upper limit because movement control and orientation were disrupted at higher velocities and motion sickness and chronic fatigue were persistent problems. Recent studies, however, are showing that, if the terminal velocity is achieved over a series of gradual steps and many body movements are made at each dwell velocity, then full adaptation of head, arm, and leg movements is possible. Rotation rates as high as 7.5-10 rpm are likely feasible. An important feature of the new studies is that they provide compelling evidence that equilibrium point theories of movement control are inadequate. The central principles of equilibrium point theories lead to the equifinality prediction, which is violated by movements made in rotating reference frames.

Coriolis Force↗

Rapid PCR amplification of DNA utilizing Coriolis effects.

A novel polymerase chain reaction (PCR) method is presented that utilizes Coriolis and centrifugal effects, produced by rotation of the sample disc, in order to increase internal circulatory rates, and with them temperature homogenization and mixing speeds. A proof of concept has been presented by testing a rapid 45-cycle PCR DNA amplification protocol. During the repeated heating and cooling that constitutes a PCR process, the 100 microL samples were rotated at a speed equivalent to an effective acceleration of gravity of 7,000 g. A cycle time of 20.5 s gave a total process time of 15 min to complete the 45 cycles. A theoretical and numerical analysis of the resulting flow, which describes the increased mixing and temperature homogenization, is presented. The device gives excellent reaction speed efficiency, which is beneficial for rapid PCR.

Coriolis Force↗

Individual differences in susceptibility to motion sickness among six Skylab astronauts.

One of the Skylab experiments dealt with motion sickness, comparing susceptibility in the workshop aloft with susceptibility preflight and postflight. Tests were conducted on and after mission-day 8 (MD 8) by which time the astronauts were adapted to working conditions. Stressful accelerations were generated by requiring the astronauts, with eyes covered, to execute standardized head movements (front, back, left, and right) while in a chair that could be rotated at angular velocities up to 30 rpm. The selected endpoint was either 150 discrete head movements or a very mild level of motion sickness. In all rotation experiments aloft, the five astronauts tested (astronaut 1 did not participate) were virtually symptom free, thus demonstrating lower susceptibility aloft than in preflight and postflight tests on the ground when symptoms were always elicited. Inasmuch as the eyes were covered and the canalicular stimuli were the same aloft as on the ground, it would appear that lifting the stimulus to the otolith organs due to gravity was an important factor in reducing susceptibility to motion sickness even though the transient stimuli generated under the test conditions were substantial and abnormal in pattern. Some of the astronauts experienced motion sickness under operational conditions aloft or after splashdown, but attention is centered chiefly on symptoms manifested in zero gravity. None of the Skylab-II crew (astronauts 1 to 3) was motion sick aloft. Astronaut 6 of the Skylab-III crew (astronauts 4 to 6) experienced motion sickness within an hour after transition into orbit; this constitutes the earliest such diagnosis on record under orbital flight conditions. The eliciting stimuli were associated with head and body movements, and astronaut 6 obtained relief by avoiding such movements and by one dose of the drug combination 1-scopolamine 0.35 mg + d-amphetamine 5.0 mg. All three astronauts of Skylab-III experienced motion sickness in the workshop where astronaut 6 was most susceptible and astronaut 4, least susceptible. The higher susceptibility of SL-III crewmen in the workshop, as compared with SL-II crewmen, may be attributable to the fact that they were based in the command module less than one-third as long as SL-II crewmen. The unnatural movements, often resembling acrobatics, permitted in the open spaces of the workshop revealed the great potentialities in weightlessness for generating complex interactions of abnormal or unusual vestibular and visual stimuli. Symptoms were controlled by body restraint and by drugs, but high susceptibility to motion sickness persisted for 3 days and probably much longer; restoration was complete on MD 7. From the foregoing statements it is clear that on and after MD 8 the susceptibility of SL-II and SL-III crewmen to motion sickness under experimental conditions was indistinguishable. The role played by the acquisition of adaptation effects prior to MD 8 is less clear and is a subject to be discussed.

Acceleration↗