Conductimetric and potentiometric detection in conventional and microchip capillary electrophoresis.

Potentiometric detection is rarely used in separation methods but is promising for certain classes of analytes which can only with difficulty be quantified by more standard methods. Conductimetric detection of ions is very versatile and has recently received renewed interest spurned by the introduction of the capacitively coupled contactless configuration. Both are useful and complementary alternatives to the established optical detection methods, and to the more widely known electrochemical method of amperometry. The simplicity of the electrochemical methods makes them particularly attractive for microfabricated devices, but relatively little work has to date been carried out with regard to potentiometric and conductimetric detection.

Conductometry↗

A contactless conductivity detector for capillary electrophoresis: effects of the detection cell geometry on the detector performance.

The effect of the gap between the electrodes and of their width on the behavior of a capacitively wired contactless conductivity detector was studied. The results obtained have indicated that the detector response can be qualitatively described by a model based on the concept of the effective electrode width which is a complex parameter determined by the gap between the electrodes, the frequency of the input signal and the conductivity of the test solution. The detector sensitivity and the effect on the separation efficiency depend on the difference between the effective and geometric electrode widths. Higher detection sensitivities have been attained for detectors with wide electrodes operating at lower frequencies, however, better separation efficiencies have been achieved using detectors with narrow electrodes and higher operational frequencies. The noise increases with decreasing gap between the electrodes and increasing frequency, especially with detectors employing narrow electrodes.

Calibration↗

Simultaneous determination of inorganic and organic anions, alkali, alkaline earth and transition metal cations by capillary electrophoresis with contactless conductometric detection.

Simultaneous separation of up to 22 inorganic and organic anions, alkali, alkaline earth and transition metal cations was achieved in less than 3 min in the capillary electrophoresis system with contactless conductometric detector. The sample was injected from both capillary ends (dual opposite end injection) and anionic and cationic species were detected in the center of the separation capillary. The parameters of the separation electrolyte, such as pH, concentration of the electrolyte, concentration of complexing agents and concentration of 18-crown-6 were studied. Best results were achieved with electrolytes consisting of 8 mM L-histidine, 2.8 mM 2-hydroxyisobutyric acid, 0.32 mM 18-crown-6 at pH 4.25 or 9 mM L-histidine, 4.6 mM lactic acid, 0.38 mM 18-crown-6 at pH 4.25. Other electrolytes containing complexing agents such as malic or tartaric acid at various concentrations could also be used. The detection limits achieved for most cations and anions were 7.5 - 62 micro gL(-1) except for Ba2+ (90 micro gL(-1)), Cd 2+, Cr 3+ and F- (125 micro gL(-1)), and fumarate (250 micro gL(-1)). The repeatability of migration times and peak areas was better than 0.4% and 5.9%, respectively. The developed method was applied for analysis of real samples, such as tap, rain, drainage and surface water samples, plant exudates, plant extracts and ore leachates.

Anions↗

Contact conductivity detection of polymerase chain reaction products analyzed by reverse-phase ion pair microcapillary electrochromatography.

We describe the development of an integrated microelectrophoretic system consisting of a contact conductivity detector mounted on-chip for monitoring the separation of double-stranded (ds) DNA fragments produced via the polymerase chain reaction (PCR) using microcapillary electrochromatography as the separation mode. The separation was carried out in a polymer-based microfluidic device, hot-embossed into poly(methylmethacrylate) (PMMA), whose walls were functionalized to produce a C(18)-terminated surface to act as the stationary phase (open channel format). The carrier electrolyte contained the ion-pairing agent, triethylammonium acetate (TEAA) to allow the separation to be carried out using reverse-phase ion-pair capillary electrochromatography (RP-IPCEC). The microelectrophoretic separations were investigated utilizing various solvent strengths (acetonitrile/water) with 25 mM TEAA to observe the effects on the separation efficiency as well as the chromatographic development time and detector performance. The field strength significantly affected the quality of the separation, with no separation observed at 333 V/cm for a low mass dsDNA sizing ladder, but baseline separation achieved using a field strength of 67 V/cm. It was observed that the solvent strength affected the retention behavior of the polyanionic molecules as well as the electroosmotic mobility. Higher acetonitrile compositions in the run buffer resulted in reduced plate numbers, which produced lower chromatographic resolution. The use of conductivity detection allowed mass detection sensitivities in the range of 10(-21) mol with a separation efficiency of 10(4) plates and the performance of the detector independent of the acetonitrile content used in the carrier electrolyte.

Acetonitriles↗

A microchip electrophoresis system with integrated in-plane electrodes for contactless conductivity detection.

We present a new approach for contactless conductivity detection for microchip-based capillary electrophoresis (CE). The detector integrates easily with well-known microfabrication techniques for glass-based microfluidic devices. Platinum electrodes are structured in recesses in-plane with the microchannel network after glass etching, which allows precise positioning and batch fabrication of the electrodes. A thin glass wall of 10-15 microm separates the electrodes and the buffer electrolyte in the separation channel to achieve the electrical insulation necessary for contactless operation. The effective separation length is 34 mm, with a channel width of 50 microm and depth of 12 microm. Microchip CE devices with conductivity detection were characterized in terms of sensitivity and linearity of response, and were tested using samples containing up to three small cations. The limit of detection for K+ (18 microM) is good, though an order of magnitude higher than for comparable capillary-based systems and one recently reported example of contactless conductivity on chip. However, an integrated field-amplified stacking step could be employed prior to CE to preconcentrate the sample ions by a factor of four.

Cations↗

High-voltage contactless conductivity detection of metal ions in capillary electrophoresis.

The detection of alkali, alkaline earth and heavy metal ions with a high-voltage capacitively coupled contactless conductivity detector (HV-C(4)D) was investigated. Eight alkali, alkaline earth metal ions and ammonium could be separated in less than 4 min with detection limits in the order of 5 x 10(-8) M. The heavy metals Mn2+, Pb2+, Cd2+ Fe2+, Zn2+, Co2+, Cu2+ and Ni2+ could also be successfully resolved with a 10 mM 2-(N-morpholino)ethanesulfonic acid/DL-histidine (MES/His)-buffer. Zn2+, Co2+, Cu2+ and Ni2+ showed an indirect response. The detection limits for the heavy metals were determined to range from about 1 to 5 microM.

Cations↗

Ionic aspects of excitation in rod outer segments.

The current status of the problem of ionic mechanisms underlying excitation of vertebrate photoreceptors is reviewed. Evidence is presented that the ionic dark current of retinal rods is sustained by the action of a ouabain-sensitive Na-K exchange pump driven by oxidative metabolism. The photoreceptors are depleted of K when the pump is stopped by ouabain. Considerations of cell membrane topology, kinetics of the light response, and signal amplification indicate that the light-induced suppression of the ionic dark current is mediated by a diffusible internal chemical transmitter substance. The desensitizing effect of low CA2+ Ringer's on the light responses of vertebrate rods, along with other indirect evidence, suggests that the transmitter substance may be calcium ions released from the internal membranous disks of the outer segments.

Animals↗

Characterization of electrostatic binding sites of extracellular polymers by linear programming analysis of titration data.

Electrostatic binding sites of extracellular polymeric substances (EPS) were characterized from titration data using linear programming analysis. Test results for three synthetic solutions of given solutes comprising amino, carboxyl, and phenolic groups indicated that this method was able to identify the electrostatic binding sites. For the six sites with pK(a) between 3 and 10, the estimated pK(a) deviated 0.11 +/- 0.09 from the theoretical values, and the estimated concentrations deviated 3.0% +/- 0.9% from the actual concentrations. Two EPS samples were then extracted from a hydrogen-producing sludge (HPS) and a sulfate-reducing biofilm (SRB). Analysis of charge excess data in titration from pH 3 to 11 indicated that the EPS of HPS comprised of five electrostatic binding sites with pK(a) ranging from 3 to 11. The pK(a) values of these binding sites and the possible corresponding functional groups were pK(a) 4.8 (carboxyl), pK(a) 6.0 (carboxyl/phosphoric), pK(a) 7.0 (phosphoric), pK(a) 9.8 (amine/phenolic), and pK(a) 11.0 (hydroxyl). EPS of the SRB comprised five of similar binding sites (with corresponding pK(a) values of 4.4, 6.0, 7.4, 9.4, and 11.0), plus one extra site at pK(a) 8.2, which was likely corresponding to the sulfhydryl group. The total electrostatic binding site concentration of EPS extracted from HPS were 10.88 mmol/g-EPS, of which the highest concentration was from the site of pK(a) 11.0. The corresponding values for the EPS extracted from SRB were 16.44 mmol/g-EPS and pK(a) 4.4. The total concentrations of electrostatic binding sites found in this study were 20- to 30-fold of those reported for bacterial cell surface, implying that EPS might be more crucial in biosorption of metals than bacterial cell surface in wastewater treatment and in bioremediation.

Bacteria↗

Separation of phenolic acids by capillary electrophoresis with indirect contactless conductometric detection.

A new method for the electrophoretic separation of nine phenolic acids (derivatives of benzoic and cinnamic acids) with contactless conductometric detection is presented. Based on theoretical calculations, in which the mobility of the electrolyte co- and counterions and mobility of analytes are taken into consideration, the electrolyte composition and detection mode was selected. This approach was found to be especially valuable for optimization of the electrolyte composition for the separation of analytes having medium mobility. Indirect conductometric detection mode was superior to the direct mode as predicted theoretically. The best performance was achieved with 150 mM 2-amino-2-methylpropanol electrolyte at pH 11.6. The separation was carried out in a counter-electroosmotic mode and completed in less than 6 min. The LODs achieved were about 2.3-3.3 microM and could be further improved to 0.12-0.17 microM by using a sample stacking procedure. The method compares well to the UV-Vis detection.

Benzoates↗

EOF measurement by detection of a sampling zone with end-channel amperometry in microchip CE.

A simple method for EOF measurement by detection of sampling zones with end-channel amperometry in microchip CE is developed. This method is based on the principle of the Kohlrausch regulating function (KRF). A dilute electroactive ionic species is added to the BGE as a continuously eluting electrophore which is used as a probe. When a BGE-like sample at a different concentration is injected, a peak of sampling zone appears and the migration time is related to EOF. In a microchip CE with hybrid PDMS/glass channel, a cathodic EOF of the hybrid glass/PDMS microchip was measured by end-channel amperometry; the effects of sample concentration and different probes on EOF rate were discussed. The present method was applied to monitor EOF rates in glass and in PDMS microchips. There was no significant difference between the values of EOF rates measured by the present method and the current-monitoring method. Detection of nonelectroactive analytes K(+), Na(+), and Li(+) can also be accomplished by the indirect amperometric method. Hence, the effective mobility of analyte can be accurately obtained.

Conductometry↗

Fabrication and characterization of semicircular detection electrodes for contactless conductivity detector - CE microchips.

This study uses simple and reliable microfabrication techniques to fabricate CE biochips, integrating a novel contactless conductivity detector in a miniaturized detection system in a microfluidic biochip. The off-channel electrodes are deposited around side channels by Au sputtering and patterned using a standard "lift-off" process. A vacuum fusion bonding process is employed to seal the lower substrate containing the microchannels and the electrodes to an upper glass cover plate. The variations in the capacitance between the semicircular detection electrodes in the side channels are measured as different samples and ions pass through the detection region of the CE separation channel. Samples of Rhodamine B, commercial sports drinks, mineral waters, and a red wine, respectively, are mixed in different buffer solutions, separated, and successfully detected using the developed device. The semicircular detection electrodes for the contactless conductivity detector have microscale dimensions and provide a valuable contribution to the realization of the lab-on-a-chip concept.

Conductometry↗

Use of micromolded carbon dual electrodes with a palladium decoupler for amperometric detection in microchip electrophoresis.

The fabrication and evaluation of micromolded dual carbon ink electrodes and their integration with a fabricated palladium decoupler for use in microchip electrophoresis is described. As opposed to previous work involving carbon-based dual electrodes with microchip electrophoresis, this approach results in electrodes that are amenable to mass production in a manner where the decoupler/electrode alignment is fixed and reproducible. In this work, electrode sizes and spacings were optimized to result in dual carbon electrodes that are 1 microm in height and separated by 100 microm. Fluorescence microscopy was used to investigate leakage around the electrode/channel interface as well as to investigate what effect the dual electrodes have on band broadening phenomena. The performance of the microelectrodes was demonstrated by the separation and selective dual electrode detection of neurotransmitters in the presence of ascorbic acid. It was also found that addition of SDS to the buffer system improved both the LODs and collection efficiencies. This approach, which is the first involving carbon-based dual electrodes with an on-chip palladium decoupler, will be useful for separating and detecting neurotransmitters that are either collected by in vivo sampling or released from cells on-chip.

Ascorbic Acid↗