Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Compressive Strength”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

High power light emitting diode (LED) arrays versus halogen light polymerization of oral biomaterials: Barcol hardness, compressive strength and radiometric properties.

The clinical performance of light polymerized dental composites is greatly influenced by the quality of the light curing unit (LCU) used. Commonly used halogen LCUs have some specific drawbacks such as decreasing light output with time. This may result in a low degree of monomer conversion of the composites with negative clinical implications. Previous studies have shown that blue light emitting diode (LED) LCUs have the potential to polymerize dental composites without having the drawbacks of halogen LCUs. Since these studies were carried out LED technology has advanced significantly and commercial LED LCUs are now becoming available. This study investigates the Barcol hardness as a function of depth, and the compressive strength of dental composites that had been polymerized for 40 or 20s with two high power LED LCU prototypes, a commercial LED LCU, and a commercial halogen LCU. In addition the radiometric properties of the LCUs were characterized. The two high power prototype LED LCUs and the halogen LCU showed a satisfactory and similar hardness-depth performance whereas the hardness of the materials polymerized with the commercial LED LCU rapidly decreased with sample depth and reduced polymerization time (20 s). There were statistically significant differences in the overall compressive strengths of composites polymerized with different LCUs at the 95% significance level (p = 0.0016) with the two high power LED LCU prototypes and the halogen LCU forming a statistically homogenous group. In conclusion, LED LCU polymerization technology can reach the performance level of halogen LCUs. One of the first commercial LED LCUs however lacked the power reserves of the high power LED LCU prototypes.

Biocompatible Materials↗

Comparison of quantitative computed tomography-based measures in predicting vertebral compressive strength.

Patient-specific measures derived from quantitative computed tomography (QCT) scans are currently being developed as a clinical tool for vertebral strength prediction. QCT-based measurement techniques vary greatly in structural complexity and generally fall into one of three categories: (1) bone mineral density (BMD), (2) "mechanics of solids" (MOS) models, such as minimum axial rigidity (the product of axial stiffness and vertebral height), or (3) three-dimensional finite element (FE) models. There is no clear consensus as to the relative performance of these measures due to differences in experimental protocols, sample sizes and demographics, and outcome metrics. The goal of this study was to directly compare the performance of QCT-based assessment techniques of varying degrees of structural sophistication in predicting experimental vertebral compressive strength. Eighty-one human thoracic vertebrae (T6-T10) from 44 donors cadavers (F=32, M=12; 85+/-8 years old, max=97 years old, min=54 years old) were QCT scanned and destructively tested in uniaxial compression. The QCT scans were processed to generate FE models and various BMD and MOS measures, including trabecular bone mineral density (tBMD), integral bone mineral density (iBMD), and axial rigidity. Bone mineral density was weakly to moderately predictive of compressive strength (R(2)=0.16 and 0.62 for tBMD and iBMD, respectively). In vitro vertebral strength was strongly correlated with both axial rigidity (R(2)=0.81) and FE strength measurements (R(2)=0.80), and the predictive capabilities of these two metrics were statistically equivalent (p>0.05 for differences between FE and axial rigidity). The results of this study indicate that non-invasive predictive measures of vertebral strength should include some level of structural sophistication, specifically, gross geometric and material property distribution information. For uniaxial compression of isolated vertebrae, which is the current biomechanical testing paradigm for new non-invasive strength assessment techniques, QCT-based FE and axial rigidity measures are equivalent predictors of experimental strength. However, before abandoning the FE method in favor of more simplistic techniques, future work should investigate the performance of the FE method versus MOS measures for more physiologically representative loading conditions, e.g., anterior bending or in situ loading with intervertebral discs intact.

Aged↗

The influence of simulated clinical handling on the flexural and compressive strength of posterior composite restorative materials.

OBJECTIVES: The aim of this study was to investigate the influence of clinical handling on the flexural and compressive strengths of two commercially available posterior composites. METHODS: Since the manufacturing of test specimens in a truly clinical situation presents many problems, an in vitro model was developed, consisting of a phantom-head set-up in a clinical operatory. Two composite materials, recommended for use in posterior teeth, were used: P50 APC (3M Dental Products) and Herculite XRV (Kerr, Dental Manufacturing). Beam specimens for 3-point bending tests of both materials and cylindrical specimens for compression test of P50 were made both under ideal laboratory circumstances and under simulated clinical circumstances. RESULTS: The difference in mean flexural strength between laboratory prepared and the quasi-clinically prepared specimens was highly significant for both the specimens handled in a clinical manner was 15% of the flexural strength of the P50 specimens made under laboratory conditions, and the difference for Herculite XRV was 29%. No difference in compressive strength could be shown between the laboratory-fabricated and the quasi-clinically made specimens of P50. SIGNIFICANCE: The relative flexural strength of composite materials in a clinical situation may differ significantly from that predicted from mechanical properties measured in vitro.

Bicuspid↗

Prediction of unconfined compressive strength of cement paste containing industrial wastes.

Neural network analysis was used to construct models of unconfined compressive strength (UCS) as a function of mix composition using existing data from literature studies of Portland cement containing real industrial wastes. The models were able to represent the known non-linear dependency of UCS on curing time and water content, and generalised from the literature data to find relationships between UCS and quantities of five waste types. Substantial decreases in UCS were caused by all wastes; except for EAF dust, the effect was nonlinear with the greatest decrease caused initially by approx. 12% plating sludge, 40% foundry dust, 58% other ash, and 72% MSWI fly ash by mass of dry product. It appears that the maximum waste additions used in modelling may approximate the practical limits of waste additions used in modelling may approximate the practical limits of waste addition to Portland cement, i.e., 50% plating sludge or EAF dust, 64% foundry dust, 92% other ash, and 85% MSWI fly ash by mass of dry product. The laboratory was found to be a key predictive variable and acted as a surrogate for laboratory-specific variables related to cement composition, strength and hardening class, product mixing and preparation details, laboratory conditions, and testing details. While the neural network modelling approach has been shown to be feasible, development of better models would require larger data sets with more complete information regarding laboratory-specific variables and waste composition.

Compressive Strength↗

[Compressive strength and deformation of dental cements].

Several dental cements have been tested for compressive strength, modulus of elasticity and plastic strain at fracture. Sylindrical specimens (4 x 6 mm) were compressed to fracture with two different crosshead speeds (2 mm/min, 0.1 mm/min) at two temperatures (23 +/- 1 degrees C and 37 +/- 1 degrees C). The results showed that the zinc phosphate cement had relatively high strength and a very small elastic and plastic strain during compression. The luting type of glass-ionomer cements showed properties near to that of the zinc phosphate cement. The other cements had either lower strength or higher elastic and plastic deformation than the zinc phosphate cement. Several cements showed a marked reduction of the mechanical properties when tested at a low crosshead speed or at 37 degrees C.

Composite Resins↗

Variations in the compressive strength of dental cements stored in ionic or acidic solutions.

The compressive strengths of various dental cements (a zinc polycarboxylate, a zinc phosphate, a glass-ionomer and two resin-modified glass ionomers, RMGICs) have been determined following storage in pure water, 0.9% sodium chloride solution or 20 mmol dm(-3) lactic acid solution for periods of time ranging from 24 h to 3 months. The glass-ionomer cement showed no differences between different storage solutions or at different storage times, whereas the zinc polycarboxylate, zinc phosphate and the resin-modified glass ionomer cements showed significant differences following storage in the solutions for 24 h compared with pure water. The zinc polycarboxylate cement was significantly weaker at 24 h in 0.9% NaCl and lactic acid than in pure water, whereas most of the other cements were significantly stronger in both 0.9% NaCl and lactic acid. One of the RMGICs (Vitremer luting, ex. 3M), however, was significantly stronger only in the NaCl solution, not in the lactic acid. In general, by 1 week, the strengths all reverted to being essentially the same as for specimens stored in pure water for most subsequent storage times, and did not change significantly on storage for up to 3 months. This effect of storage medium on the early strength has not been reported previously and since the media were chosen to model certain characteristics of natural saliva, the changes observed seem likely to occur in vivo. It is concluded that pure water is not the best medium for storing these cements if they are to behave as they do under clinical conditions.

Journal Article↗

Compressive strength of two modern all-ceramic crowns.

This study investigated the compressive strength of all-ceramic crowns manufactured using two recently introduced systems. The mean forces of fracture were 964 N for In-Ceram crowns, 814 N for paint-on IPS Empress crowns, and 750 N for layered IPS Empress crowns, compared with 1,494 N for metal ceramic crowns veneered on a nickel-chromium coping. The results indicate that clinical testing of these all-ceramic crowns is reasonable. Controlled, clinical, long-term evaluation is necessary to assess the safe application of these new crown systems.

Aluminum Oxide↗

The bone mineral content and ultimate compressive strength of lumbar vertebrae.

The bone mineral content of 109 lumbar vertebrae from 36 different subjects was determined by dual photon absorptiometry. The mean age of the subjects was 58.5 years (range, 31 to 79 years). The ultimate strength of the vertebral bodies was determined during axial compression. Bone mineral content and ultimate compressive strength were correlated (r = 0.86) and the strength was found to increase linearly with increasing amounts of bone mineral content. No differences in this correlation were found in the four vertebral levels (L-4) included in the study, but a difference in this correlation was found between specimens taken from male and female subjects. The results make it possible to estimate the strength of a vertebral body from the knowledge of its bone mineral content as determined by dual photon absorptiometry and provide a basis of estimations of normal and abnormal amounts of bone mineral content in the vertebrae of the lumbar spine.

Adult↗

Sustained loading increases the compressive strength of articular cartilage.

INTRODUCTION: When synovial joints are subjected to sustained or repetitive loading, fluid is driven from the articular cartilage so that it is less able to equalise compressive stress between opposing joint surfaces. We test the hypothesis that sustained loading reduces the compressive strength of cartilage-on-bone. METHODS: Forty specimens of articular cartilage-on-bone, approximately 15 mm square, were removed from the patella groove of mature bovine knees. Specimens were loaded on a materials testing machine using a 5 mm-diameter plane-ended indentor. Controlled loading/unloading cycles of 1s duration, and of increasing severity, were applied until failure was evident on the force-deformation graphs. Half of the specimens were 'creep loaded' for 30 at 2 MPa before their strength was assessed. After testing, damage was investigate using ink staining of the cartilage surface, and histology. RESULTS: Sustained loading reduced cartilage thickness by 45% and creep-loaded specimens were 21% stronger (P = 0.01). Most specimens appeared to fail by fissuring of the cartilage surface zone. CONCLUSION: Sustained loading strengthens cartilage by expelling water from it, reducing the tendency of the surface zone to rupture in the manner of an over-inflated car tyre.

Animals↗

Age-related changes in the compressive strength of cancellous bone. The relative importance of changes in density and trabecular architecture.

UNLABELLED: Compressive testing to failure in the weight-bearing axis was done on 255 specimens of cancellous bone that had been machined from forty-four femora from human cadavera. The donors had ranged in age from twenty to 102 years at the time of death. After mechanical testing, the apparent density and trabecular architecture were determined. Linear regression analysis showed that the compressive strength decreased by 8.5 per cent each decade (p < 0.001). Apparent density and volume fraction also decreased significantly with age (p < 0.001). Histomorphometric analysis demonstrated that the surface-to-volume ratio and the mean separation of the trabecular plate increased with age, whereas the mean thickness and connectivity of the trabecular plate decreased. Both bivariate and multivariate analyses demonstrated that age-related changes in apparent density played an important role in the decrease in mechanical strength, accounting for a 92 per cent reduction. Microstructural changes were highly correlated with apparent density and therefore had little independent effect. Thus, similar to the situation with cortical bone, the quantitative changes in aging cancellous-bone tissue, rather than the qualitative changes, influenced the mechanical competence of the bone. CLINICAL RELEVANCE: This study provides information concerning the difference in the properties of human cancellous bone as a function of age. Because of the importance of changes in apparent density, non-invasive means can be used to estimate the mechanical properties of cancellous bone in vivo. Thus, it may be possible to predict the risk of fracture and to explain further some aspects of the mechanics of fracture in the elderly.

Adult↗

Cortical mineral content of the radius assessed by peripheral QCT predicts compressive strength on biomechanical testing.

Our aim was to evaluate the role of cortical bone in resistance to compression in the human radius. Thirty-three left cadaver forearms were scanned on an XCT 960 Stratec CT scanner. Cortical density and cortical thickness were measured at the junction of the middle and distal third of the radius. Subsequently, 2-cm-high cylindrical specimens, centrated on the level of the CT slice, were cut. After removal of the endosteal trabecular bone, the specimens were submitted to compressive testing, using an Instron machine, and load deformation curves were obtained. Maximal stress (load corrected for cross-sectional area) showed a significant relationship with the density (r = 0.78) as well as with the thickness (r = 0.74) of the cortex. The closest correlation involved the maximal load and the mineral content of the cortex specimens (r = 0.87). We conclude that the mineral content of these radius cortex specimens, measured using peripheral QCT, predicts their compressive strength on biomechanical testing.

Aged↗

Unconfined compressive strength prediction for the ordinary Portland cement-steel slag-silica fume ternary system based on response surface methodology.

This research was undertaken to address environmental concerns associated with industrial solid waste and to reduce cement consumption in geotechnical engineering. It specifically investigates the feasibility of using steel slag (SS) and silica fume (SF) as partial substitutes for ordinary Portland cement (OPC) in soil stabilization. The effects of SS, SF, OPC, and initial moisture content on the unconfined compressive strength (UCS) of stabilized soil were investigated through single-factor experiments and response surface methodology (RSM). The results show that SS and SF can synergistically enhance the strength of stabilized soil, although their interaction effect was not statistically significant within the investigated ranges. Compared with soil stabilized solely with OPC, the addition of 18 % SS and 10 % SF reduced OPC consumption by 3 % without compromising strength. Microstructural and compositional analyses further revealed that SS mainly supplied calcium- and silica-bearing components, while SF provided highly reactive silica and micro-filling effects, jointly promoting hydration reactions and improving the compactness of the stabilized soil matrix. As a result, more hydration products were formed in the OPC/SS/SF-stabilized soil than in the OPC-stabilized soil, which contributed to pore filling and strength enhancement. This study provides useful guidance for the sustainable utilization of industrial solid waste and the low-carbon development of soil stabilization materials.

Construction Materials↗

Study of resin-bonded calcia investment: Part 1. Setting time and compressive strength.

This study was carried out to develop a new titanium casting investment consisting of calcia as the refractory material and a cold-curing resin system as the binder. The setting time of the investment was investigated under different N,N-dimethyl-p-toluidine (DMPT) contents in methyl methacrylate monomer (MMA) and benzoyl peroxide (BPO) contents in calcia without any sintering agent. The effects of the sintering agents, which were calcium fluoride (CaF2) and calcium chloride (CaCl2), on the compressive strength of the investments were investigated at room temperature before and after heating to two different temperatures. The shortest setting time (68 minutes) of the investment was obtained at 0.37 DMPT/BPO (1.5 vol% /1.0 mass%) ratio by mass. The highest strength (16.5 MPa) was obtained from the investment which contained 2 mass% CaF2 and was heated to 1,100 degrees C. It was found that the developed calcia investment containing 2 mass% CaF2 has a possibility for use in titanium castings.

Alloys↗

Changes in compressive strength on ageing in glass polyalkenoate (glass-ionomer) cements prepared from acrylic/maleic acid copolymers.

Previous studies have shown that glass-ionomers made from acrylic/maleic copolymers stored in water reach a maximum strength at about 1 week, and after 4 months have become significantly weaker. This finding, which contrasts with the behaviour of glass-ionomers based on poly(acrylic acid), was originally attributed to hydrolytic instability. This interpretation has been tested in the current work. Specimens of glass-ionomer prepared from acrylic/maleic acid copolymer have been stored for up to 4 months in different media, namely deionized water, dry air and vegetable oil, then tested for compressive strength. Specimens were in the form of cylinders of dimensions 6 mm high x 4 mm diameter, and storage temperature was 37 degrees C. Data were analysed using two-way analysis of variance (ANOVA) and in all three media specimens became weaker at 4 months than they had been at 1 week (P < 0.05). However, for the specimens stored in dry air and in water, the 1-week values were not the maximum. The fact that there was a loss of strength under all conditions led to the conclusion that it is not, after all, due to hydrolysis.

Acrylates↗

The compressive strength of nonprecious versus precious ceramometal restorations with various frame designs.

This study was designed as a comparative analysis of the compressive strengths of precious versus nonprecious metals with various framework designs used in clinical restorations. One hundred thirty-five statistically uniform ceramometal restorations were fabricated. The restorations were cemented to the die and then subjected to stroke-control compression forces in an Instron loading machine. Simulated clinical failure was recorded by the Instron load cell recorder in pounds of load.

Chromium Alloys↗

Biomechanical behavior of hydroxyapatite as bone substitute material in a loaded implant model. On the surface strain measurement and the maximum compression strength determination of material crash.

Many investigators have advocated that hydroxyapatite ceramics may be extremely prospective bone substitute material mainly through evidence with its given biocompatibility towards bone and demonstrated continuity between living bone and hydroxyapatite. Its mechanical brittleness and strength, however, have been the most serious considerations. In this paper, a study has been performed using animal experiments, massive hydroxyapatite ceramics are implanted into rectangular bone defect created by operation at the load-bearing area in close contact with tibia plateau. The changes of surface strain at the hydroxyapatite implantation of retrieved tibiae are measured at any week after implantation when the compressive stress were applied in the direction of long axis in order to clarify the mechanical behaviors of hydroxyapatite living bone complex. The compression strength of hydroxyapatite implant crash was also determined at each week after implantation. Results revealed that the hydroxyapatite living bone complex has been proven to have sufficient flexibility such that it shows no hysteresis in stress versus strain relationship up to 200 kg of applied load. The strain pattern on the surface of hydroxyapatite implant develops quite similar to that of natural cortical bone. The material crash of hydroxyapatite implant tolerates up to 500 kg of load at 52 weeks after implantation. These characteristics suggest that it achieves normal skeletal function in the points of biomechanical properties in vivo.

Animals↗

Effect of porosity reduction by compaction on compressive strength and microstructure of calcium phosphate cement.

Hydroxyapatite (HA) calcium phosphate cements (CPCs) are attractive materials for orthopedic applications because they can be molded into shape during implantation. However their low strength and brittle nature limits their potential applications to principally non-load-bearing applications. Little if any use has been made of the HA cement systems as manufacturing routes for preset HA bone grafts, which although not moldable pastes, are resorbable, unlike HA sintered ceramic. It is known that the strength of cements can be increased beyond that attainable from slurry systems by compaction, and this study investigates whether compaction significantly alters the specific surface area and pore-size distribution of CPC prepared according to the method of Brown and Chow. Compaction pressures of between 18 and 106 MPa were used to decrease the porosity from 50 to 31%, which resulted in an increase in the wet compressive strength from 4 to 37 MPa. The Weibull modulus was found to increase as porosity decreased; in addition the amount of porosity larger than the reactant particle size increased as porosity decreased. It is proposed that this was caused by a combination of voids created by the aqueous solvent used in fabrication and shrinkage that occurs on reaction. The specific surface area was unchanged by compaction.

Biocompatible Materials↗

Effects of phase transformations of silicas and calcium sulfates on the compressive strength of gypsum-bonded investments at high temperatures.

The effects of transformations of silicas and calcium sulfates on high temperature compressive strength were investigated in commercial and experimental investment materials containing fused quartz as silica. The strength is only slightly affected by the alpha leads to beta transformation of cristobalite and not by the quartz alpha leads to beta transformation. The state of the calcium sulfates is the main factor influencing variations in the strength at a particular temperature.

Calcium Sulfate↗