Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ChIP”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

[Investigations on the shape and size of bone-chips produced during boring and grinding (author's transl)].

Examinations of the shape and size of chips produced during boring and grinding of dry macerated and fresh temporal bone by various drills and grinders at different revolutions show that rose trepans mainly scrape fresh bone, producing large rolled-up chips, but knock off dry macerated bone, producing more compact chips of bizarre shape. In either case the chip waste also contains plenty of fine and finest compact chips which are broken off and splinter during the removal or knocking-off of the chips from solid bone. The size of the chip depends on the size of the drill head. Diamond cutting heads produce fine and finest compact bone chips. Bone milling produces plenty of scrapes even from dry macerated temporal bone. The rate of revolutions (10,000-80,000 per min) had no influence on the shape and size of chips. Clinically the scraped chip seems to be the most favourable in the drilling of bone because it causes least damage. The use of a drill head with sharp-edged, intact cutting surfaces seems important for this, with continuous rinsing during the boring process to prevent soiling of the interspaces between the cutters and to ensure full performance in accordance with their construction.

Humans↗

Distribution of mRNA encoding the FA-CHIP water channel in amphibian tissues: effects of salt adaptation.

A water channel, the frog aquaporin-CHIP (FA-CHIP) was recently cloned from Rana esculenta urinary bladder. The 28.9 kDa encoded protein shows 78.8%, 77.4%, 42.4% and 35.6% identity with rat CHIP28, human CHIP28, rat WCH-CD and gamma-TIP, other members of the new transmembrane water channel family (Aquaporin-CHIP). We have now studied membranes from different frog (R. esculenta) organs employing semiquantitative PCR using FA-CHIP specific primers and an internal standard to quantify the PCR products. The FA-CHIP mRNA was abundantly expressed in the frog urinary bladder, skin, lung and gall bladder, while a lower expression was detected in the colon, liver and oviduct. FA-CHIP mRNA was not detected in the frog kidney, erythrocytes and brain but its expression was observed in the toad (Bufo arenarum) urinary bladder and skin, showing that FA-CHIP is probably a general amphibian water channel. Salt acclimation is known to increase the water permeability of frog and toad epithelia. We have now observed that salt acclimation for 1, 3, 4 or 5 days markedly increased skin and urinary bladder FA-CHIP mRNA expression. It is generally accepted that water permeability is controlled in these tissues by the rate of water channel transfer from subapical vesicles (aggrephores) to the apical membrane. Our results indicate that water permeability is also regulated at the level of the FA-CHIP transcription.

Adaptation, Physiological↗

Integrated polymerase chain reaction chips utilizing digital microfluidics.

This study reports an integrated microfluidic chip for polymerase chain reaction (PCR) applications utilizing digital microfluidic chip (DMC) technology. Several crucial procedures including sample transportation, mixing, and DNA amplification were performed on the integrated chip using electro-wetting-on-dielectric (EWOD) effect. An innovative concept of hydrophobic/hydrophilic structure has been successfully demonstrated to integrate the DMC chip with the on-chip PCR device. Sample droplets were generated, transported and mixed by the EWOD-actuation. Then the mixture droplets were transported to a PCR chamber by utilizing the hydrophilic/hydrophobic interface to generate required surface tension gradient. A micro temperature sensor and two micro heaters inside the PCR chamber along with a controller were used to form a micro temperature control module, which could perform precise PCR thermal cycling for DNA amplification. In order to demonstrate the performance of the integrated DMC/PCR chips, a detection gene for Dengue II virus was successfully amplified and detected. The new integrated DMC/PCR chips only required an operation voltage of 12V(RMS) at a frequency of 3 KHz for digital microfluidic actuation and 9V(DC) for thermal cycling. When compared to its large-scale counterparts for DNA amplification, the developed system consumed less sample and reagent and could reduce the detection time. The developed chips successfully demonstrated the feasibility of Lab-On-a-Chip (LOC) by utilizing EWOD-based digital microfluidics.

Dengue Virus↗

Chip-based P450 drug metabolism coupled to electrospray ionization-mass spectrometry detection.

A chip-based P450 in vitro metabolism assay coupled with ESI-MS and ESI-MS/MS detection is described in this paper. The chips were made of a cyclic olefin polymer using a hot embossing process. The introduction of reagent solutions into the chip was carried out using fused-silica capillaries coupled to two syringes with the flow rate controlled by a syringe pump. Initial experiments described here employed a small commercial guard column in an off-chip format to desalt and concentrate the products of the enzymatic reaction prior to ESI-MS analysis. The system was used both to yield the Michaelis constant (K(m)) of the P450 biotransformation of imipramine into desipramine and to determine the IC50 value of a chemical inhibitor (tranylcypromine) for this CYP2C19-mediated reaction. The results demonstrated that the kinetics of the reaction inside the 4-microL volume within the channels of the cyclic olefin polymer chip provided results in agreement with those reported in the literature using conventional assays. The above reactions were carried out using human liver microsomes, and the metabolites were detected by ESI-MS showing the potential of the chip-based P450 reaction for metabolite screening studies as well as for P450 inhibition assays. A porous monolithic column was subsequently integrated into the chip to perform the reaction mixture cleanup process in an integrated fashion on the chip that is necessary for ESI-MS detection. The miniature monolithic SPE column was prepared in situ inside the chip via UV-initiated polymerization. The results obtained using the integrated system demonstrated the possibility of performing P450 enzymatic reactions in a microvolume reaction chamber coupled directly to ESI-MS detection and required less than 4 microg of HLM protein.

Alkenes↗

Carboxyl terminus of hsc70-interacting protein (CHIP) can remodel mature aryl hydrocarbon receptor (AhR) complexes and mediate ubiquitination of both the AhR and the 90 kDa heat-shock protein (hsp90) in vitro.

The regulation of the aryl hydrocarbon receptor (AhR) protein levels has been an area of keen interest, given its important role in mediating the cellular adaptation and toxic response to several environmental pollutants. The carboxyl terminus of hsc70-interacting protein (CHIP) ubiquitin ligase was previously associated with the regulation of the aryl hydrocarbon receptor, although the mechanisms were not directly demonstrated. In this study, we established that CHIP could associate with the AhR at cellular levels of these two proteins, suggesting a potential role for CHIP in the regulation of the AhR complex. The analysis of the sucrose-gradient-fractionated in vitro translated AhR complexes revealed that CHIP can mediate hsp90 ubiquitination while cooperating with unidentified factors to promote the ubiquitination of mature unliganded AhR complexes. In addition, the immunophilin-like protein XAP2 was able to partially protect the AhR from CHIP-mediated ubiquitination in vitro. This protection required the direct interaction of the XAP2 with the AhR complex. Surprisingly, CHIP silencing in Hepa-1c1c7 cells by siRNA methods did not reveal the function of CHIP in the AhR complex, because it did not affect well-characterized activities of the AhR nor affect its steady-state protein levels. However, the presence of potential compensatory mechanisms may be confounding this particular observation. Our results suggest a model where the E3 ubiquitin ligase CHIP cooperates with other ubiquitination factors to remodel native AhR-hsp90 complexes and where co-chaperones such as the XAP2 may affect the ability of CHIP to target AhR complexes for ubiquitination.

Animals↗

A metal-chelating piezoelectric sensor chip for direct detection and oriented immobilization of polyHis-tagged proteins.

A metal-chelating piezoelectric (PZ) chip for direct detection and controlled immobilization of polyHis-tagged proteins has been demonstrated. The chip was prepared by covalently binding a hydrogel matrix complex of oxidized dextran and nitrilotriacetic acid (NTA) ligand onto an activated alkanethiol-modified PZ crystal. The resulting chip effectively captured Ni2+ ions onto its NTA surface, as disclosed by the resonant frequency shift of the crystal and an X-ray photoelectron spectroscopy analysis. The real-time frequency analysis revealed that the bare NTA chip was nonfouling, regenerable, and highly reusable during continuous repetitive injections of ion solutions and binding proteins. In addition, the chip displayed good long-term reusability and storage stability. The individual binding studies of a polyHis-tagged glutathione-S-transferase and its native untagged form on various metal-charged chips revealed that Co2+, Cu2+, and Ni2+ ions each had different immobilization ability on the NTA surface, as well as their binding ability and selectivity with the tagged protein. As a result, the tagged protein immobilized on the Ni2+-charged chip can actively be bound with its antibody and substrate. Further, the quantitative analyses of the tagged protein in crude cell lysate with a single Ni2+-charged chip and of its substrate with a protein-coated chip were also successfully demonstrated. Therefore, this study initiates the possibilities of oriented, reversible, and universal immobilization of any polyHis-tagged protein and its functional study using a real-time PZ biosensor.

Biosensing Techniques↗

Construction of a cultivation system of a yeast single cell in a cell chip microchamber.

A novel single cell screening system was constructed using a yeast cell chip in combination with the yeast cell surface engineering [NanoBiotechnology 2005, 1, 105-111]. Enzymes or functional proteins displayed on a yeast cell surface can be used as a protein cluster. To achieve high-throughput screening of protein libraries on the cell surface, a catalytic reaction by a single cell-surface-engineered yeast cell was successfully carried out in the microchamber on the yeast cell chip. After screening, to replicate a target cell for use in measuring of activity, DNA sequencing, and preservation, a novel single cell cultivation system in the yeast cell chip was constructed. To avoid damage of the rapid dry up of medium in the microchamber array, the yeast cell chip was modified with a protection sheet, so that the modified chip was like a micro-culture tank constructed on the yeast cell chip microchamber. As a result, single yeast cell cultivation in the yeast cell chip microchamber was observed, and the modified yeast cell chip was evaluated to be good for a single cell selection. The improvement showed that the single cell screening system coupled with the single cell cultivation using the modified yeast cell chip may be superior to that by a cell sorter for the isolation of a target cell and its practical use.

Cell Count↗

Automated chromatin profiling with spa-ChIP-seq uncovers the impacts of condition variations.

Chromatin immunoprecipitation followed by sequencing (ChIP-seq) is widely used to study the genomic localization of DNA-associated proteins. However, conventional protocols include multiple manual steps that can introduce inconsistency and limit scalability, thereby restricting the inclusion of appropriate replicates and controls. Although the introduction of liquid handling platforms has improved reproducibility, most existing efforts have automated only a subset of the workflow, and extending automation to efficiently map non-histone proteins, such as chromatin regulators, remains challenging. Here, we present a fully automated implementation of our previously developed single-pot ChIP-seq protocol (Texari et al. 2021), named spa-ChIP-seq, which enables scalable processing of 8 to 96 ChIP-seq samples from crosslinked cells to sequencing-ready library in approximately three days with an estimated cost of $70 per sample. Benchmarking spa-ChIP-seq against manual ChIP-seq performed in parallel demonstrates comparable signal-to-noise ratio between the two workflows. Using spa-ChIP-seq, we systematically evaluate multiple parameters including shearing and crosslinking conditions, buffer compositions, and the ratio of antibody to cell-number. We find, for the first time to our knowledge, that weaker genomic localization signals are sensitive to changing the antibody to cell-number ratio, whereas the stronger signals remain unaffected. This finding underscores the importance of maintaining consistent antibody-to-cell-number ratio for comparative studies, such as treatment responses or chromatin-QTL mapping. The spa-ChIP-seq protocol is publicly available, including deck setups, operational parameters, and scripts. We envision that this robust, cost-efficient protocol will facilitate high-throughput, reproducible ChIP-seq analyses, supporting large-scale studies of antibody validation, compound screening, population genomics, and diagnostic frameworks.

Journal Article↗

[On vibration hazards of chipping-hammer operators in an iron foundry. Part 2. Results of the hygienic control].

We previously reported that the working and health conditions of vibrating tool operators in an iron foundry were investigated in 1975 and vibration hazards were observed to occur frequently in workers operating chipping-hammers powered by compressed air. After that, we instituted medical treatment for the afflicted workers and improvement of working conditions in the foundry, and have performed annual medical examinations for four years. In this paper, the course of hygienic control and the change in the medical findings of twenty-four chipping-hammer operators are reported. 1. The following measures were taken to improve the working conditions of chipping-hammer operators and therapy for patients (Table 1): (1) The operating time of vibrating tools, including chipping-hammer, was limited to two hours per day. The casting process was improved to diminish the flashes that are the objects of chipping-hammer operation. For the purpose of reducing the vibration transmitted to the operator, a servo-arm that has a servomechanism for the chipping-hammer was developed and introduced. (2) Infrared lamps in the foundry and air curtains at the doorway were installed for keeping the chipping-hammer operating area warm. A warm room was set up in the foundry for providing warmth during rest periods and protective clothing against the cold was provided. (3) Workers who displayed health disturbances by medical examinations were treated during the cold season from November to April by periodic visits to the clinic or extended hospitalization, or transferred to job without vibration exposure, according to their stage of disease. Preventive treatment with vasodilator and bubble bath was performed in winter for the chipping-hammer operators. 2. In order to estimate the effect of these countermeasures, annual medical examinations were conducted in March 1975, March 1976, April 1977 and March 1978. Such subjective symptoms as Raynaud's phenomenon, finger numbness, finger listlessness, heavy-headedness, forgetfulness, irritability and hearing disorder showed a tendency for improvement, but other complaints did not (Tables 2-4). The improvement of Raynaud's phenomenon is considered to be due not merely to the countermeasures but also to reducing the chance of provocation and therefore the countermeasures should not be overestimated as a factor of recovery of vibration hazards. Of the functional tests, a tendency for improvement was recognized in sensory functions and peripheral circulatory functions, but not in motor functions (Tables 5, 6). However, the course of recovery was not fast and some advanced cases, especially those using chipping-hammers for more than ten years, showed less improvement after hospital treatment (Table 7, Fig. 1). This indicates the importance of hygienic control which enables vibration hazards patients to have early diagnosis and treatment. Furthermore, in order to eradicate the vibration hazards in the cast metal industry, a drastic reform of the finishing process is considered to be necessary.

Adult↗

Hepatitis gene chip in detecting HBV DNA, HCV RNA in serum and liver tissue samples of hepatitis patients.

OBJECTIVE: To study the preparation of diagnostic gene chip for detecting hepatitis B virus (HBV) and hepatitis C virus (HCV) and its accuracy in detecting HBV DNA and HCV RNA in serum and liver tissues. METHODS: The probes, which depend on the conservative gene fragment of hepatitis virus, was designed, synthesized and spotted on the modified glass. The probes and some other control probes were assembled on the diagnostic microarray of hepatitis virus. The gene of hepatitis virus, purified from blood or tissue, was labeled with fluorescence and hybridized to the microarray. The hybridized microarry was scanned with microarray scanner and the diagnostic result was analyzed from the scanning data. Fourty patients with hepatitis B virus and 40 healthy people or 40 patients with hepatitis C virus were subjected to detection of HBV DNA and HCV RNA with the hepatitis virus gene chip by the double-blind method. Paraffin liver specimens obtained from 99 cases of posthepatitic cirrhosis were used to detect HBV DNA. The liver tissues and serum from 15 cases of chronic hepatitis B were used to detect HBV DNA. Simultaneously, HBsAg and HBcAg were detected in the serum by fluorescence microparticle quantitation, HBV DNA and HCV RNA in the serum by PCR, and HBcAg in liver tissues by immunocytochemistry or HBV DNA by in situ molecular hybridization. RESULTS: Chip detection of serum specimens showed that 30 patients were HBV DNA positive and 10 HBV DNA negative in the 40 patients with HBV positive, 25 patients were HCV RNA positive and 15 patients were HCV RNA negative in the 40 patients with HCV positive, and all were HBV and HCV negative in the 40 healthy people. In 15 patients with HBV marker positive who were subjected to liver biopsy, 15 patients were detected HBV DNA positive in serum by gene chip, 15 patients HBcAg positive in liver tissues by immunocytochemistry, 14 patients HBV DNA positive in liver tissues by in situ molecular hybridization, and 14 patients HBV DNA positive in liver tissues by gene chip. Paraffin liver tissues specimens from the 99 patients with posthepatitis B cirrhosis showed that 67 patients were detected HBcAg positive by immunocytochemistry, 53 patients HBV DNA positive by in situ molecular hybridization, and 46 patients HBV DNA positive by gene chip. In the 46 patients, 40 patients were detected HBV DNA and HBcAg positive by in situ molecular hybridization and immunocytochemistry, 6 patients only HBcAg positive, and 33 patients HBcAg negative. CONCLUSIONS: The designed diagnostic gene chip can be used to simultaneously detect serum HBV DNA and HCV RNA, but the positive rate of HCV RNA diagnosed by this chip is lower. The gene chip can detect HBV DNA in serum and in liver tissue.

DNA, Viral↗

The human aquaporin-CHIP gene. Structure, organization, and chromosomal localization.

Aquaporin-CHIP is the first known molecular water channel. Originally identified in red cells and renal tubules, transcripts and proteins related to AQP-CHIP are also expressed in diverse epithelia with distinct developmental patterns. Northern analyses of RNA from several tissues revealed transcripts of 3.1 kilobases and other sizes. The nucleotide sequences of human kidney AQP-CHIP cDNAs are identical to the human bone marrow AQP-CHIP cDNA. The 17-kilobase human AQP-CHIP structural gene was isolated, and restriction maps were constructed and partially sequenced. The TATA consensus sequence is located 87 bp 5' to the translation initiation site, and sequences surrounding the polyadenylation consensus were determined. Four exons were identified corresponding to amino acids 1-128, 129-183, 184-210, and 211-269, separated by introns of 9.6, 0.43, and 0.80 kilobases. Genomic Southern analyses indicated the existence of a single AQP-CHIP gene which was located at human chromosome 7p14 by in situ hybridization. Sequence comparisons of AQP-CHIP and cDNAs of similar proteins from diverse species suggested a common evolutionary origin. At least three of these proteins are now known to function as membrane water pores and are referred to as the "Aquaporins." These genomic AQP-CHIP DNA sequences should permit molecular characterization of the complex patterns of AQP-CHIP expression.

Animals↗

Demonstration of aquaporin-CHIP in peritoneal tissue of uremic and CAPD patients.

Aquaporin-CHIP is a 28 kD channel forming integral membrane protein. It acts as an osmotically driven, water-selective pore. The presence of aquaporin-CHIP has been demonstrated in the proximal tubule in the kidney and in the pleura, as well as in other tissues. During peritoneal dialysis a dissociation between the transport of water and sodium using hyperosmolar solutions has been reported, suggesting the presence of ultrasmall pores. Water channels, like aquaporin-CHIP, could be the morphological equivalent of these pores. We investigated the possible presence of aquaporin-CHIP in cryo-sections of peritoneal tissue using affinity purified human anti-CHIP IgC (P. Agre, Baltimore, MD). Peritoneal biopsies (omenta) were obtained at catheter insertion in 2 uremic patients with end-stage renal disease, and at catheter reimplantation of 1 patient treated with continuous ambulatory peritoneal dialysis (CAPD) for two years. Peritoneal tissue obtained at autopsy from 1 patient who had been on CAPD for four years, but in whom CAPD had been discontinued for five months, was also studied. Aquaporin-CHIP antiserum specific staining was found in the endothelial cells of the peritoneal capillaries in all patients. No obvious difference in the intensity of staining was seen between uremic and CAPD patients. This demonstration of aquaporin-CHIP in human peritoneal endothelial cells supports the hypothesis of the existence of ultrasmall pores within the peritoneal membrane. These water channels facilitate the transcellular transport of water, induced by an osmotic gradient, in the absence of sodium transport. It may be the explanation for the dissociation of water and sodium transport that occurs during hyperosmolar solutions. Aquaporin-CHIP is present in human peritoneal endothelial cells in both uremic and CAPD patients. Aquaporin-CHIP may be the morphological equivalent of the ultrasmall pores within the peritoneal membrane.

Aquaporin 1↗

Development of a new hybrid technique for rapid speciation analysis by directly interfacing a microfluidic chip-based capillary electrophoresis system to atomic fluorescence spectrometry.

This paper represents the first study on direct interfacing of microfluidic chip-based capillary electrophoresis (chip-CE) to a sensitive and selective detector, atomic fluorescence spectrometry (AFS) for rapid speciation analysis. A volatile species generation technique was employed to convert the analytes from the chip-CE effluent into their respective volatile species. To facilitate the chip-CE effluent delivery and to provide the necessary medium for subsequent volatile species generation, diluted HCl solution was introduced on the chip as the makeup solution. The chip-CE-AFS interface was constructed on the basis of a concentric "tube-in-tube" design for introducing a KBH4 solution around the chip effluent as sheath flow and reductant for volatile species generation as well. The generated volatile species resulting from the reaction of the chip-CE effluent and the sheath flow were separated from the reaction mixture in a gas-liquid separator and swept into the AFS atomizer by an argon flow for AFS determination. Inorganic mercury (Hg(II)) and methylmercury (MeHg(I)) were chosen as the targets to demonstrate the performance of the present technique. Both mercury species were separated as their cysteine complexes within 64 s. The precision (relative standard deviation, RSD, n = 5) of migration time, peak area, and peak height for 2 mg.L(-1) Hg(II) and 4 mg.L(-1) MeHg(I) (as Hg) ranged from 0.7 to 0.9%, 2.1 to 2.9%, and 1.5 to 1.8%, respectively. The detection limit was 53 and 161 microg.L(-1) (as Hg) for Hg(II) and MeHg(I), respectively. The recoveries of the spikes of mercury species in four locally collected water samples ranged from 92 to 108%.

Electrophoresis, Microchip↗

The three-dimensional structure of human erythrocyte aquaporin CHIP.

Water-permeable membranes of several plant and mammalian tissues contain specific water channel proteins, the 'aquaporins'. The best characterized aquaporin is CHIP, a 28 kDa red blood cell channel-forming integral protein. Isolated CHIP and Escherichia coli lipids may be assembled into 2-D crystals for structural analyses. Here we present (i) a structural characterization of the solubilized CHIP oligomers, (ii) projections of CHIP arrays after negative staining or metal-shadowing, and (iii) the 3-D structure at 1.6 nm resolution. Negatively stained CHIP oligomers exhibited a side length of 6.9 nm with four-fold symmetry, and a mass of 202 +/- 3 kDa determined by scanning transmission electron microscopy. Reconstituted into lipid bilayers, CHIP formed 2-D square lattices with unit cell dimensions a = b = 9.6 nm and a p422(1) symmetry. The 3-D map revealed that CHIP tetramers contain central stain-filled depressions about the fourfold axis. These cavities extend from both sides into the transbilayer domain of the molecule leaving only a thin barrier to be penetrated by the water pores. Although CHIP monomers behave as independent pores, we propose that their particular structure requires tetramerization for stable integration into the bilayer.

Aquaporin 1↗

Examination of rat salivary glands for the presence of the aquaporin CHIP.

The aquaporin CHIP, AQP-CHIP, is a 28-kDa integral membrane protein that functions as a water channel in kidney and red blood cells. We have examined rat salivary glands for the presence of this molecule. In Northern blot analyses an AQP-CHIP cDNA hybridized to rat kidney mRNA approximately 20-fold more than to mRNA from the rat parotid gland. Western blot analyses, using antisera against human AQP-CHIP, showed that AQP-CHIP was present in crude membranes from rat salivary glands to a much lesser extent than in rat kidney membranes. A 2.8 kb cDNA encoding AQP-CHIP was also isolated from an adult rat parotid gland cDNA library. Immunolocalization studies using thin and ultrathin cryosections and light and electron microscopy, however, revealed that no glandular epithelium was labeled. In contrast, significant immunolabeling was present in microvascular endothelial cells. Non-fenestrated endothelia of capillaries and venules exhibited labeling on both their apical and basolateral membranes. The present study demonstrates that AQP-CHIP is not involved directly in fluid secretion from salivary epithelial cells. Further, this study provides strong evidence that AQP-CHIP is an endothelial cell water channel found within salivary gland tissue which may contribute to water permeability in the capillary beds.

Animals↗

Analysis of ligase chain reaction products amplified in a silicon-glass chip using capillary electrophoresis.

Ligase chain reaction (LCR) is a useful molecular technique for detecting known point mutations. We report the first example of the use of a disposable silicon-glass micro-chip for LCR and the first application of capillary electrophoresis (CE) to analyze samples amplified by LCR in a chip. Silicon-glass chips were manufactured using conventional photolithography and anodic bonding. The chips provide three distinct advantages for LCR: excellent thermal conductivity, a micro reaction volume ( < 10 microliters), and reproducible, low-cost manufacturing. Investigation and quantitation of amplification efficiency of LCR in a chip or in a tube requires an analytical technique that is faster and more convenient than the conventional slab gel methods. Slab gel electrophoresis uses relatively large amounts of sample and is labor-intensive and time-consuming, and thus is unsuitable for the separation and detection of LCR products. In contrast CE requires sample volume (original LCR products) of less than 1 microliter and is therefore well-suited to analysis of the micro-volume reaction mixture from chips. We combined CE with a sensitive laser induced fluorescence (LIF) detection system for the rapid separation and quantitative detection of LCR products amplified from the lacI gene in a silicon-glass chip. Comparative studies were made with LCR between tubes and silicon-glass chips. CE-LIF analysis is ideally suited to examination of micro-LCR amplification with high throughput. The technologies may find medical uses in disease diagnosis and research.

Base Sequence↗

Automatic bio-sampling chips integrated with micro-pumps and micro-valves for disease detection.

The present study reports a microfluidic system using the concept of membrane-movement to design and fabricate micro-pneumatic valves and pumps to form a bio-sensing diagnostic chip. The automatic bio-sampling system includes a micro-diagnostic chip fabricated by using MEMS (micro-electro-mechanical systems) technology and an automatic platform comprising of a control circuit, a compressed air source and several electromagnetic valve switches. The control circuit is used to regulate the electromagnetic valve switches, causing thin PDMS membranes to deflect pneumatically by the compressed air and generate valving and pumping effects. The micro-diagnostic chip allows for the quick detection of diseases. Compared to large-scale systems, the new microfluidic system uses smaller amounts of samples and reagents and performs fast diagnosis in an automated format. Instead of using traditional pneumatic micro-pumps, the current study adopts a new design called "spider-web" micro-pumps to increase the pumping rate, and more importantly, improve the uniformity of flow rates inside multiple micro-channels. Experimental data show that for disease diagnosis, the bio-sensing chips integrated with the micro-pneumatic valves and the peristaltic micro-pumps could successfully perform diagnosis tests. Small amounts of samples and reagents could be injected into the diagnosis chips using the micro-pumps and the micro-pneumatic valves could effectively control the movement of the samples and reagents. In order to demonstrate the functionality of the developed device, detection of hepatitis C virus (HCV) and syphilis has been performed using the bio-sampling chips. Experimental data show that fluorescence signals from the microfluidic system were comparable to the ones using conventional testing methods. The developed chip could be easily extended for multiple disease detection. The automatic bio-sensing chips could provide a useful tool for fast disease detection and be crucial for a micro-total-analysis system.

Biosensing Techniques↗

Rapid and onsite BOD sensing system using luminous bacterial cells-immobilized chip.

A BOD monitoring system based on a bio-chip which immobilized luminous bacterium in micrometer-order holes were arrayed and fabricated by micro-machine techniques, was developed. The acrylic chip (3 cmx3 cm) comprises nine micro-holes (diameter: 700 microm or 1 mm, depth: 100 microm) arranged in a three by three array. Cells of the marine luminous bacterium, Photobacterium phosphoreum IFO 13896, which was grown at 15 degrees C for 15 h, were immobilized with 3% or 15% sodium alginate gel. BOD standard solutions or actual sample solution (approximately 10 microl) was fallen onto the cell-arrayed chip, and then the chip was incubated at 25 degrees C for 25 min. After incubation, bioluminescence from the each hole was gray-scaled and measured by a chemi-imager or newly developed onsite-type-monitoring system using a digital camera and a mobile-type personal computer. BOD values less than 16 ppm could detect by the chip, in particular, linear relationship at the concentrations between 0 and 16 ppm could be observed when luminous cells were immobilized with 3% sodium alginate gel. Steady bioluminescence was observed on the chip in the presence of BOD standard solution (GGA solution) which contained mineral elements. Furthermore, simultaneous detection of BOD values in various samples could be employed in the single chip. These results showed that the monitoring system with bio-chip could achieve high-through-put and onsite BOD detection. Our newly developed onsite-type BOD detection system which was used a digital camera and a (mobile) laptop computer was applied to measure and detect organic pollution due to biodegradable substances in wastewater treatment system. The same performance as the chemi-imager system was obtained for data of bioluminescence. The obtained BOD values showed a similar correlation with that of the conventional method for BOD determination (BOD5). These results suggested for successful achievement of high-though-put and onsite detection of BOD in practical.

Biosensing Techniques↗