Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Analytic Sample Preparation Methods”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6Linked to original sources

Quantitative determination of helicid in rat plasma by liquid chromatography-electrospray ionization mass spectrometry and its application to preliminary pharmacokinetic studies.

A sensitive and selective liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) method was developed for the identification and quantification of helicid in rat plasma. The method was based on simple liquid-liquid extraction (LLE). A Kromasil C18 column (150mmx2.00mm, 3.5microm) was used as the analytical column, while a mixture of acetonitrile and 500microM ammonium chloride was used as the mobile phase. MS detection was performed using a single quadrupole mass spectrometer in a negative selected ion monitoring (SIM) mode. The deprotonated molecules [M+Cl](-) at m/z 319.00 and 363.05 were used to quantify helicid and bergeninum (internal standard, I.S.), respectively. The lower limit of quantification of helicid was 1ng/ml. The method was linear in the concentration range of 1-1000ng/ml. The intra-day and inter-day precisions (R.S.D.%) were within 10.0% for the analyte. Helicid proved to be stable during all sample storage, preparation and analytical periods. The method was successfully applied to a pharmacokinetic study in rats after intragastric administration of helicid with a dose of 50mg/kg. Only 50microl of rat plasma at each sampling time was needed for analysis. The proposed method enables unambiguous identification and quantification for the preliminary pharmacokinetic studies of helicid.

Animals↗

Sampling hazelnuts for aflatoxin: uncertainty associated with sampling, sample preparation, and analysis.

The variability associated with the aflatoxin test procedure used to estimate aflatoxin levels in bulk shipments of hazelnuts was investigated. Sixteen 10 kg samples of shelled hazelnuts were taken from each of 20 lots that were suspected of aflatoxin contamination. The total variance associated with testing shelled hazelnuts was estimated and partitioned into sampling, sample preparation, and analytical variance components. Each variance component increased as aflatoxin concentration (either B1 or total) increased. With the use of regression analysis, mathematical expressions were developed to model the relationship between aflatoxin concentration and the total, sampling, sample preparation, and analytical variances. The expressions for these relationships were used to estimate the variance for any sample size, subsample size, and number of analyses for a specific aflatoxin concentration. The sampling, sample preparation, and analytical variances associated with estimating aflatoxin in a hazelnut lot at a total aflatoxin level of 10 ng/g and using a 10 kg sample, a 50 g subsample, dry comminution with a Robot Coupe mill, and a high-performance liquid chromatographic analytical method are 174.40, 0.74, and 0.27, respectively. The sampling, sample preparation, and analytical steps of the aflatoxin test procedure accounted for 99.4, 0.4, and 0.2% of the total variability, respectively.

Aflatoxins↗

Improvements in the sample preparation for the determination of ruthenium in catalysts by different spectrometric techniques.

The sample preparation steps of two analytical methods for the determination of ruthenium in carbon supported catalysts with flame atomic absorption spectrometry (FAAS) or UV-vis spectrophotometry, were carefully optimised. As a first step, the carbon support is ignited in air at 450 degrees C then the residue is fused with potassium hydroxide and potassium nitrate to convert ruthenium into ruthenate anion RuO4(2-). The melt is dissolved in water with potassium persulphate and potassium hydroxide as stabilisers. Ruthenium may be directly estimated by measuring the UV-vis molecular absorption of ruthenate at the isosbestic point of the ruthenate-perruthenate mixture or by FAAS. In the latter case, an aliquot of the sample solution is added to the concentrated hydrochloric acid to obtain hexachlororuthenate RuCl6(2-), that is nebulized into the flame after proper dilution. This novel procedure allows to determination of ruthenium without the sensitivity loss (-66%) which occurs in the alkaline media resulting from the fusion. The relative standard deviation is 1.1% for FAAS and 1.3% for UV-vis, at 5% Ru (n = 7). The detection limit (3sB) is 0.07% Ru for FAAS and 0.02% Ru for UV-vis. Both methods were applied to the analysis of a commercial sample and a statistical comparison was carried out.

Catalysis↗

Sampling foods for mycotoxins.

It is difficult to obtain precise and accurate estimates of the true mycotoxin concentration of a bulk lot when using a mycotoxin-sampling plan that measures the concentration in only a small portion of the bulk lot. A mycotoxin-sampling plan is defined by a mycotoxin test procedure and a defined accept/reject limit. A mycotoxin test procedure is a complicated process and generally consists of several steps: (1) a sample of a given size is taken from the lot, (2) the sample is ground (comminuted) in a mill to reduce its particle size, (3) a subsample is removed from the comminuted sample, and (4) the mycotoxin is extracted from the comminuted subsample and quantified. Even when using accepted test procedures, there is uncertainty associated with each step of the mycotoxin test procedure. Because of this variability, the true mycotoxin concentration in the lot cannot be determined with 100% certainty by measuring the mycotoxin concentration in a sample taken from the lot. The variability for each step of the mycotoxin test procedure, as measured by the variance statistic, is shown to increase with mycotoxin concentration. Sampling is usually the largest source of variability associated with the mycotoxin test procedure. Sampling variability is large because a small percentage of kernels are contaminated and the level of contamination on a single seed can be very large. Methods to reduce sampling, sample preparation and analytical variability are discussed.

Food Analysis↗

Detecting mycotoxins in agricultural commodities.

It is difficult to obtain precise and accurate estimates of the true mycotoxin concentration of a bulk lot when using a mycotoxin-sampling plan that measures the concentration in a small portion of the bulk lot. A mycotoxin-sampling plan is defined by a mycotoxin test procedure and a defined accept/reject limit. A mycotoxin test procedure is a complicated process and generally consists of several steps: (a) a sample is taken from the lot, (b) the sample is ground (comminuted) in a mill to reduce particle size, (c) a subsample is removed from the comminuted sample, and (d) the mycotoxin is extracted from the comminuted subsample and quantified. Even when using accepted test procedures, there is variability associated with each step of the mycotoxin test procedure. Because of this variability, the true mycotoxin concentration in the lot cannot be determined with 100% certainty by measuring the mycotoxin concentration in a sample taken from the lot. The variability for each step of the mycotoxin test procedure, as measured by the variance statistic, is shown to increase with mycotoxin concentration. Sampling is usually the largest source of variability associated with the mycotoxin test procedure. Sampling variability is large because a small percentage of kernels are contaminated and the level of contamination on a single seed can be very large. Methods to reduce sampling, sample preparation, and analytical variability are discussed.

Aflatoxins↗

Forensic applications of chemical imaging: latent fingerprint detection using visible absorption and luminescence.

Chemical imaging technology is a rapid examination technique that combines molecular spectroscopy and digital imaging, providing information on morphology, composition, structure, and concentration of a material. Among many other applications, chemical imaging offers an array of novel analytical testing methods, which limits sample preparation and provides high-quality imaging data essential in the detection of latent fingerprints. Luminescence chemical imaging and visible absorbance chemical imaging have been successfully applied to ninhydrin, DFO, cyanoacrylate, and luminescent dye-treated latent fingerprints, demonstrating the potential of this technology to aid forensic investigations. In addition, visible absorption chemical imaging has been applied successfully to visualize untreated latent fingerprints.

Aza Compounds↗

Analytical methods for the determination of acrylamide in food products: a review.

In early 2002, the Swedish National Food Administration reported high acrylamide levels in heat-treated carbohydrate-rich foods. Consequently, intensive activity began examining the many different types of food, and thousands of analyses have been undertaken world wide. Measurement data have been published in many different types of media. Within this flood of publications, there are only a limited number of articles concerned with the technical aspects of the measurements. This review focuses on the state-of-the-art in the analysis of acrylamide in foodstuffs. It covers information on methods from peer-reviewed articles and other sources (e.g. a survey carried out among official and private laboratories of the Member States of the European Union). Alternative methods are presented and discussed alongside the more common measurement techniques for acrylamide in foodstuffs. Special attention is given to sample preparation. The greatest differences between the analytical methods was for acrylamide extraction and clean-up. The influence of different extraction techniques or extraction solvents/solvent mixtures on the measurement results has not yet been fully investigated. There is also a lack of understanding about the sample clean-up. Since both might have a large impact on the results of the analysis, this review should also be considered as a basis for further investigations.

Acrylamide↗

Two-layer sample preparation: a method for MALDI-MS analysis of complex peptide and protein mixtures.

The analytical performance of matrix-assisted laser desorption/ionization (MALDI) mass spectrometry for direct analysis of peptide and protein mixtures is strongly dependent on the sample and matrix preparation. A two-layer sample preparation method is demonstrated to be very effective for analyzing complex mixtures. In this method, the first layer on the MALDI probe is the densely packed matrix microcrystals formed by fast solvent evaporation of a matrix solution. A mixture solution containing both matrix and sample is then deposited onto the first layer to form uniform analyte/matrix micrococrystals. It is found that the addition of matrix to the second-layer sample solution proves to be critical in analyzing mixtures of peptides and proteins covering a broad mass range. The effect of solvent conditions for preparing the second-layer solution is discussed. The application of this method is demonstrated for the analysis of cow's milk where milk proteins as well as peptide fragments produced from proteins by indigenous proteinases are detected. Direct analyses of peptides and proteins from a bacteria extract and crude egg white are also illustrated.

Amino Acid Sequence↗

Chromatography as a reference technique for the determination of clinically important steroids.

Chromatographic methods (paper chromatography, thin layer chromatography, high performance liquid chromatography, gas chromatography and gas chromatography-mass spectrometry) for the determination of clinically important steroids in biological specimens are reviewed. The emphasis is on the use of gas chromatography, gas chromatography-mass spectrometry and high performance liquid chromatography as reference rather than routine techniques. Chromatographic methods are compared with colorimetric, fluorimetric and radioimmunoassay procedures in terms of simplicity of operation, cost and ability to analyse large numbers of specimens. The importance of correct specimen collection and storage are discussed. Sample preparation techniques for the various analytical methods are described. These include extraction of free and conjugated steroids from serum, plasma, urine and saliva by solvent partition, with polymer-based resins such as Amberlite XAD-2, DEAE-Sephadex and Sephadex resins bonded with various other function groups and, more recently, with chemically bonded reversed-phase silicas.

Chromatography↗

SPME-GC-pyrolysis-AFS determination of methylmercury in marine fish products by alkaline sample preparation and aqueous phase phenylation derivatization.

Characterization of a cost-efficient analytical method based on alkaline sample digestion with KOH and NaOH, followed by aqueous phase phenylation derivatization with NaBPh4 and solid phase microextraction (SPME) for the determination of methylmercury in typical fish-containing food samples commercially available in Hungary, is reported. The sample preparation procedure along with the applied SPME-GC-pyrolysis-AFS system was validated by measuring certified reference materials (CRM) BCR-464, TORT-2, and a candidate CRM BCR 710. To carry out an estimation of average Hungarian methylmercury exposures via marine fish and/or fish-containing food consumption, 16 commercially available products and 3 pooled representative seafood samples of-according to a previous European survey--the three most consumed fish species in Hungary, herring, sardines, and hake, were analyzed. Methylmercury concentrations of the analyzed samples were in the range 0.016-0.137 microg of MeHg g(-1) dry weight as Hg.

Chromatography, Gas↗

Simultaneous quantification of cryptotanshinone and its active metabolite tanshinone IIA in plasma by liquid chromatography/tandem mass spectrometry (LC-MS/MS).

A rapid and sensitive method for the simultaneous determination of cryptotanshinone and its active metabolite tanshinone IIA in rat plasma was developed and well validated, using high-performance liquid chromatographic separation with tandem mass spectrometric detection. This method entailed a single step of liquid-liquid extraction with ethyl acetate from a small volume of plasmas. The analytes and internal standard diazepam were baseline separated on a Shim-pack VP-ODS analytical column. Detection was performed on a triple quadrupole tandem mass spectrometer equipped with electrospray ionization source operated under selected reaction monitoring (SRM) mode. The method was linear in the concentration range of 1-100 ng/ml for both tanshinone IIA and cryptotanshinone. The intra- and inter-day precisions (R.S.D.%) were within 10.2% for both analytes. Deviation of the assay accuracies was within +/-12.0% for both analytes. Both analytes were proved to be stable during all sample storing, preparation and analytic procedures. The method was successfully applied to a pharmacokinetic study after an oral administration of cryptotanshinone to rats with a dose of 20 mg/kg. With the lower limits of quantification at 1.0 ng/ml for tanshinone IIA and 0.2 ng/ml for cryptotanshinone, this method was proved to be sensitive enough and reproducible for the pharmacokinetics study of both tanshinones.

Abietanes↗

A new method for measurement of (-)-sophocarpine, a candidate therapeutic for viral myocarditis, in plasma: application to a toxicokinetic study in beagle dogs.

The naturally occurring alkaloid (-)-sophocarpine (SC) has been developed as a novel anti-coxsackieviral agent for potential treatment of viral myocarditis. However, there is currently no rapid, sensitive method available for ascertaining systemic exposure during the course of SC toxicity studies. The development and full validation of the first rapid and sensitive method, based on liquid chromatography with tandem mass spectrometry (LC/MS/MS), for determination of SC in plasma is reported here. This new assay increases sample throughput by using minimal sample clean-up procedures and short chromatographic analysis times. The bio-matrix effect on the ionization of SC and the internal standard, (-)-stepholidine, was investigated for method development and validation, and two organic solvents (methyl tert-butyl ether and ethyl acetate) were found for sample preparation that led to low matrix effects. The new analytical method was used to analyze plasma samples obtained from a repeated-dose toxicity study of SC in beagle dogs. The results of the toxicokinetic analysis indicated that the systemic exposure to SC was proportional to the dose, and that no significant accumulation of SC was observed after 3 months of repeated treatments with intravenous SC at 7.5, 15, or 30 mg/kg/day. This sensitive and specific LC/MS/MS technique can form the basis for accurate quantification of SC in various biological fluids for preclinical and clinical pharmacokinetic evaluation.

Alkaloids↗

Simultaneous quantification of chlorogenic acid and caffeic acid in rat plasma after an intravenous administration of mailuoning injection using liquid chromatography/mass spectrometry.

A simple, rapid and sensitive method was developed for the simultaneous quantification of chlorogenic acid (CGA) and caffeic acid (CA) in rat plasma using a high-performance liquid chromatography system coupled to a negative ion electrospray mass spectrometric analysis. The plasma sample preparation was a simple deproteinization by the addition of two volumes of acetonitrile followed by centrifugation. The analytes and internal standard ferulic acid were separated on an Intersil C8-3 column (5 mm; 250 x 2.1 mm) with acetonitrile/0.05% triethylamine solution (70:30, v/v) as mobile phase at a flow rate of 0.2 mL/min with an operating temperature of 30 degrees C. Detection was performed on a quadrupole mass spectrometer equipped with an electrospray ionization (ESI) source operated in selected ion monitoring (SIM) mode. Negative ion ESI was used to form deprotonated molecules at m/z 353 for chlorogenic acid, m/z 179 for caffeic acid, and m/z 193 for the internal standard ferulic acid. Linear detection responses were obtained for CGA concentrations ranging from 0.005 to 2.0 microg/mL and for CA concentrations ranging from 0.010 to 2.0 microg/mL and the lower limits of quantitation (LLOQs) for CGA and CA were 0.005 and 0.01 microg/mL, respectively. The intra- and inter-day precisions (RSD%) were within 9.0% for both analytes. Deviation of the assay accuracies was within +/-10.0% for both analytes. Their average recoveries were greater than 88.0%. Both analytes were proved to be stable during all sample storage, preparation and analytic procedures. The method was successfully applied to the pharmacokinetic study of CGA and CA following an intravenous dose of 5 mL/kg mailuoning injection to rats.

Animals↗

Applications of ion chromatography in the semiconductor industry. II. Determination of basic airborne contaminants in a cleanroom.

Since the geometry of semiconductors and integrated circuits has been shrunk to well below sub-micron dimensions, there is a great demand for precise and reliable analytical techniques to measure and monitor the contaminants in all areas related to the fabrication process. Special concerns about the air cleanliness in a Fab lead to the necessity for developing analytical techniques to perform this task. In this research, basic airborne contaminants in a cleanroom were adsorbed onto a collection tube, subsequently extracted with deionized water and analyzed by ion chromatography. Such a method is capable of simultaneously measuring the concentrations of ammonia and cations (e.g., sodium, potassium, calcium, magnesium, etc.) present in the cleanroom air samples. The optimal sample preparation method was determined and the analyte concentrations at various locations in the cleanroom were measured. The results showed significant variations from one location to another. The long-term fluctuations in the contaminant levels were also significant. Data obtained using this method compared well with data from inductively coupled plasma analysis of the same materials.

Air Pollutants↗

Analysis of N7-(benzo[a]pyrene-6-yl)guanine in urine using two-step solid-phase extraction and isotope dilution with liquid chromatography/tandem mass spectrometry.

Analysis of urinary N7-(benzo[a]pyren-6-yl)guanine (BP-6-N7Gua), a DNA adduct induced by benzo[a]pyrene, may serve as a risk-associated biomarker for exposure to polyaromatic hydrocarbons (PAHs). In this study a highly sensitive and specific analytical method, incorporating on-line sample preparation coupled with isotope-dilution liquid chromatography and tandem mass spectrometry (LC/MS/MS), was developed to quantitate this adduct in human urine. In order to achieve accurate quantitation, 15N5-labeled BP-6-N7Gua was synthesized to serve as the internal standard, and a two-step solid-phase extraction (SPE) procedure using C8 and SCX cartridges was used for sample cleanup. BP-6-7-N7Gua was analyzed using positive ion LC/MS/MS operated in multiple reaction monitoring (MRM) mode. The [M+H]+ ions at m/z 402 and 407 and the common fragment ion of [M+H]+ at m/z 252 were monitored for quantification. The recovery of this analyte after two-step SPE was 90%, and the limit of detection was 2.5 fmol/mL in 10 mL of urine. This highly specific and sensitive method for BP-6-N7Gua in urine may be applied to assess exposure to PAHs in coke-oven workers for future molecular epidemiology studies on health effects of PAHs.

Benzopyrenes↗

Influence of sample preparation on analytical results: drug analysis [GC/MS] on hair snippets versus hair powder using various extraction methods.

The comparison of aqueous extraction methods and hair extraction by organic solvents performed on hair powder as well as on hair snippets of the same sample revealed different qualities of the procedures. Qualitative and quantitative results by the same derivatization step and GC/MS detection demonstrated, that the risk of missing a drug substance is higher using hair snippets than after drug extraction on pulverised hair. Drug recovery for opiates, cocaine and benzoylecgonine from hair was found to be best in aqueous solvents or in methanol extracts. The results are discussed under the aspects of solid-phase extraction, the hair sample representing an inhomogenous material. The localisation of drug molecules in hair, the hair swelling and penetration behavior of the particular extraction medium as well as the partition coefficient of solvent/hair phase for a particular drug substance are considered to influence the results.

Gas Chromatography-Mass Spectrometry↗

Detection of multiple anions by thin-layer chromatography.

A novel detection method for 21 different anions by thin-layer chromatography is presented. Anions on the target plate form salts with amine in a developing solvent and are visualized after staining with citric acid-acetic anhydride reagent as white spots contrasting against a pale red-pink background. This method has particularly high sensitivity for anions of chlorate, sulfate, phosphate, chromate and dichromate (0.02-0.05 microg). The method is demonstrated to efficiently detect toxic arsenite in curry sauce as an example application. The proposed method offers highly efficient indirect detection for a wide range of anions, and serves as a purification procedure for the preparation of anionic sample solutions for other analytical methods.

Anions↗

[X-ray fluorescence analysis of Kaolin concentrate].

An X-ray fluorescence technique was developed for the analysis of Al2O3, SiO2 and impurities in Kaolin concentrate. Two standard series, one for dual series of Al2O3-SiO2 and the other for all of the impurities, were prepared, respectively, from spectral pure agents based on the estimates of analyte content ranges and matrix effects in Kaolin concentrate. Powderd sample after determination of loss of ignition was pressed into disc by means of a little powderd sample preparation method modyfied in this paper. All analyte contents were calculated directly from the calibration curves without any matrix correction. In contrast to fusion technique the method has no the effects of flux impurities and dilute ration on the determination of minor and micro components in Kaolin concentrate. Errors of the results are < 1% for major component Al2O3, SiO2 and total, and < 5% for most and < 10% for few of the impurities.

English Abstract↗