Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “sample preparation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59Linked to original sources

An alternative method to amplify RNA without loss of signal conservation for expression analysis with a proteinase DNA microarray in the ArrayTube format.

BACKGROUND: Recent developments in DNA microarray technology led to a variety of open and closed devices and systems including high and low density microarrays for high-throughput screening applications as well as microarrays of lower density for specific diagnostic purposes. Beside predefined microarrays for specific applications manufacturers offer the production of custom-designed microarrays adapted to customers' wishes. Array based assays demand complex procedures including several steps for sample preparation (RNA extraction, amplification and sample labelling), hybridization and detection, thus leading to a high variability between several approaches and resulting in the necessity of extensive standardization and normalization procedures. RESULTS: In the present work a custom designed human proteinase DNA microarray of lower density in ArrayTube format was established. This highly economic open platform only requires standard laboratory equipment and allows the study of the molecular regulation of cell behaviour by proteinases. We established a procedure for sample preparation and hybridization and verified the array based gene expression profile by quantitative real-time PCR (QRT-PCR). Moreover, we compared the results with the well established Affymetrix microarray. By application of standard labelling procedures with e.g. Klenow fragment exo-, single primer amplification (SPA) or In Vitro Transcription (IVT) we noticed a loss of signal conservation for some genes. To overcome this problem we developed a protocol in accordance with the SPA protocol, in which we included target specific primers designed individually for each spotted oligomer. Here we present a complete array based assay in which only the specific transcripts of interest are amplified in parallel and in a linear manner. The array represents a proof of principle which can be adapted to other species as well. CONCLUSION: As the designed protocol for amplifying mRNA starts from as little as 100 ng total RNA, it presents an alternative method for detecting even low expressed genes by microarray experiments in a highly reproducible and sensitive manner. Preservation of signal integrity is demonstrated out by QRT-PCR measurements. The little amounts of total RNA necessary for the analyses make this method applicable for investigations with limited material as in clinical samples from, for example, organ or tumour biopsies. Those are arguments in favour of the high potential of our assay compared to established procedures for amplification within the field of diagnostic expression profiling. Nevertheless, the screening character of microarray data must be mentioned, and independent methods should verify the results.

Cells, Cultured↗

[Studies on the preparation of sample solution for determination of nicotinic acid and nicotinamide in foods by high performance liquid chromatography].

A method for preparation of sample solution for determination of nicotinic acid (NA) and nicotinamide (NAA) in foods by high performance liquid chromatography has been studied. NA and NAA were simultaneously extracted from foods with methanol, then the extracts were cleaned up by use of a Sep-Pak tC18 cartridge. NA and NAA in each sample solution were determined by high performance liquid chromatography. Recoveries of NA and NAA from various foods spiked at levels of 25 and 250 micrograms/g were not less than 70%.

Chromatography, High Pressure Liquid↗

Development and application of new nucleic acid-based technologies for microbial community analyses in foods.

Several challenges still persist in the analysis of microorganisms in foods, particularly in studies of complex communities. Nucleic acid-based methods are promising tools in addressing new questions concerning microbial communities. We have developed several new methods in the field of nucleic acid-based microbial community analyses. These methods cover both sample preparation and detection approaches. The sample preparation method involves simplified DNA purification using paramagnetic beads. As an extension of this method, the same paramagnetic beads are used for both cell separation and DNA purification. This enables full automation. The separate detection of viable and dead bacteria is a major issue in nucleic acid-based diagnostics. We have applied a living/dead dye that binds covalently to DNA and inhibits the PCR from dead cells. In addition, a DNA array-based detection assay has been developed. The assay combines the specificity obtained by enzymatic labeling of DNA probes with the possibility of detecting several targets simultaneously by DNA array hybridization. In combination with 16S rDNA amplification, this is a promising tool for community analyses. Also, we have developed a novel approach for multiplex quantitative PCR. The multiplex PCR has been combined with our DNA array-based detection method. Finally, we are now in the process of adapting a system for monitoring microbial growth and death in real-time through the tagging of bacteria with green fluorescent protein (GFP) combined with fluorescence detection using a high-resolution confocal laser scanner.

Bacteria↗

Direct determination of stability of protease inhibitors in plasma by HPLC with automated column-switching.

Automated column-switching HPLC methods were developed and utilized for the direct analyses of three hydroxamic acid based metalloprotease inhibitors in rat plasma. These column-switching methods involved the use of a restricted-access media (RAM) precolumn and a column-switching valve, allowing the complete automation of sample preparation and HPLC. The plasma samples were directly injected onto a precolumn packed with SPS/ODS stationary phase and then backflushed onto an ODS analytical column using a 6-port column-switching device. The drug stability in rat plasma was determined using both the automated and traditional HPLC methods. The results obtained from the automated column-switching methods were in good agreement with those from traditional methods that involve sequential protein precipitation, liquid extraction, solvent evaporation, and sample reconstitution. In addition to the elimination of labor-intensive and time-consuming sample preparation procedures, the column-switching methods allowed on-line analyte enrichment and accurate determination of drug stability in plasma with detection limits in the range of 10-20 ng/ml(-1). This work represents, for the first time, a drug stability study in plasma by automated column-switching HPLC technique with the use of a RAM column. Our column-switching methods can be readily adapted to any existing HPLC system with minimal hardware modification.

Animals↗

A rapid, simple and sensitive flow cytometric system for detection of Plasmodium falciparum.

We have established a rapid, simple and sensitive flow cytometric system for the detection of Plasmodium falciparum that involves lysing erythrocytes and staining parasites at the same time using a newly developed hemolysing and staining solution containing dodecyl methyl ammonium chloride and acridine orange. In this system, freed parasites of P. falciparum could be plotted separately from erythrocyte ghosts, white blood cells and platelets on the two-dimensional scattergram of forward-angle light scatter and green fluorescence by flow cytometry with an argon laser. It took only 2-3 min per sample to obtain the scattergram and analyze the data, including the time of sample preparation for flow cytometric analysis. Sample preparation with this method does not require any difficult handling procedures. The threshold of parasite detection was almost equal to that of microscopic examination for cultured P. falciparum. The results of drug-susceptibility assays using this system were also almost identical to those obtained using microscopic examination. In this system, parasites at different erythrocytic stages could be easily distinguished. This system must prove useful and practical for basic laboratory studies of P. falciparum including those requiring the differential measurement of parasites at specific erythrocytic stages.

Acridine Orange↗

Monitoring protein expression in whole bacterial cells with MALDI time-of-flight mass spectrometry.

We report the application of matrix-assisted laser desorption ionization (MALDI) to monitor recombinant protein expression in whole bacteria. This technique is characterized by rapid sample preparation that provides analysis of samples extracted directly from the growth media in less than 10 min. The mass spectrometric method holds several advantages over gel electrophoresis, the conventional method for examining the protein content of cells. Comparisons between the two methods of analysis are presented in terms of increased speed, efficiency, resolution, and mass accuracy. Delayed extraction time-of-flight mass spectrometry identifies posttranslational modifications and other changes in the expected structure which are not recognized by gel electrophoresis. The utility of this method is demonstrated for proteins with molecular masses ranging from 5 to 50 kDa. Low molecular mass proteins (< 10 kDa) can be efficiently analyzed without any treatment of the bacterial broth prior to MALDI sample preparation. The MALDI analysis of higher molecular weight proteins shows enhanced sensitivity when the bacterial solutions are first sonicated.

Bacterial Proteins↗

A non-perturbing scheme for the mineralogical characterization and quantification of inorganic colloids in natural waters.

Although the role played by inorganic colloids in natural waters depends on their composition as well as on their size, the characterization of submicron particles has rarely gone beyond describing the morphology and identifying some of the most abundant particles. The process of quantification has been hampered by a lack of suitable analytical methods. This study demonstrates that it is possible to identify and quantify inorganic particles in the colloidal size range by applying a straightforward methodology based on a well-proved, quantitative, and nonperturbing method of sample preparation (direct centrifugation of the samples on transmission electron microscopy grids) in conjunction with particle analysis using widely available techniques: transmission electron microscopy, energy dispersive X-ray spectroscopy (EDS), and selected area electron diffraction (SAED). The method has successfully been applied to six water samples from basins of contrasting geological characteristics. The method has the advantage of minimizing sample modifications by allowing on site sample preparation, using standard equipment, and it is not particularly time-consuming. Notably, the combination of EDS and SAED information makes it possible to characterize and quantify the most abundant components of the colloidal pool in the majority of the aquatic systems: the different types of aluminosilicates.

Colloids↗

Urinary organic acid screening by solid-phase microextraction of the methyl esters.

We developed a new sample preparation method for profiling organic acids in urine by GC or GC-MS. The method includes derivatisation of the organic acids directly in the aqueous urine using trimethyloxonium tetrafluoroborate as a methylating agent, extraction of the organic acid methyl esters from the urine by solid-phase microextraction, using a polyacrylate fiber with a thickness of 85 microm and transfer of the methyl esters into the GC or the GC-MS instrument. Desorption of the analytes takes place in the heated injection port. The proposed sample preparation is very simple. There is no need for any evaporation step and for the use of an organic solvent. The risk of contamination and the loss of analytes are minimized. The total sample preparation time prior to GC or GC-MS analysis is about 40 min, and therefore more rapid than other sample preparation procedures. The urinary organic acids are well separated by GC and 29 substances are identified by GC-MS.

Borates↗

Application of the combination of isotope ratio monitoring with isotope dilution mass spectrometry to the determination of glucose in serum.

Isotope ratio monitoring combined with n((13)C)/n((12)C) isotope dilution mass spectrometry (IRM/IDMS) provides results of low uncertainty of the order of 0.1% if it is applied to the analysis of simple mixtures as found in organic chemistry, even if only low (13)C spike additives to the sample are used. If the method is applied to the analysis of systems that require large-scale sample preparation prior to the measurement, such as the determination of glucose in serum, the results obtained exhibit a higher uncertainty that is comparable to that of the conventional gas chromatography/isotope dilution mass spectrometry (GC/IDMS) method. The reason for this observation is that the small contribution that the IRM/IDMS method makes to the uncertainty budget of the result is superimposed on a large contribution due to the sample preparation. It appears therefore that the IRM/IDMS method has no advantage over the conventional GC/IDMS method. However, if a series of measurements is carried out, and if a suitable experimental design is chosen, the IRM/IDMS method can provide valuable additional information. The influence of sample preparation on each individual result can be quantified as its deviation from the average value of all results of the series. From these data conclusions can be drawn for an improvement in sample preparation.

Algorithms↗

Detection of antibodies to HTLV-III in commercially available immunoglobulin preparations.

Samples of 96 polyvalent and virus-specific immunoglobulin batches commercially available in West-Germany were tested by enzyme-linked immunoassay and immunoblot for the presence of anti-HTLV-III antibodies. 37% of the polyvalent and 87% of the virus-specific batches were positive. It was concluded that these preparations are still safe and because of their reportedly low titer neutralizing antibodies possibly beneficial in certain cases, such as newborns of HTLV-III positive mothers or after accidental exposure to infectious material in clinics or laboratories.

Acquired Immunodeficiency Syndrome↗

Thrombospondin-1, a natural inhibitor of angiogenesis, is present in vitreous and aqueous humor and is modulated by hyperglycemia.

Negative regulators of angiogenesis play a major role in maintaining vascular homeostasis. Thrombospondin-1 (TSP1) is a natural inhibitor of angiogenesis. This report examines the presence of TSP1 in ocular samples and determines whether its production is altered in diabetes. Western blot analysis detected a 140 kDa antiangiogenic fragment of TSP1(gp140) in vitreous samples prepared from normal human and rat eyes. Intact TSP1 was detected in aqueous humor samples prepared from normal rat and bovine eyes. In contrast, TSP1 was virtually absent in vitreous and aqueous humor samples prepared from diabetic rat eyes. Furthermore, production of TSP1 by microvascular endothelial cells in culture was sensitive to high concentrations of glucose. Retinal blood vessels appeared nonuniform and dilated in diabetic animals when compared to control animals. These results demonstrate that TSP1 and its antiangiogenic fragment are present in aqueous humor and vitreous of normal rat eyes and are dramatically reduced in diabetes. Thus, TSP1 may play a role in ocular vascular homeostasis and its absence may contribute to vascular dysfunctions associated with diabetes.

Animals↗

Development and validation of a direct, non-destructive quantitative method for medroxyprogesterone acetate in a pharmaceutical suspension using FT-Raman spectroscopy.

A simple linear regression method was developed and statistically validated for the direct and non-destructive quantitative analysis--without sample preparation--of the active pharmaceutical ingredient (API) medroxyprogesterone acetate (MPA) in an aqueous pharmaceutical suspension (150 mg in 1.0 ml) using FT-Raman spectroscopy. The linear regression was modelled by plotting the highest peak intensity of the vector normalized spectral band between 1630 and 1590 cm-1 against different MPA standard suspension concentrations. At this band, no spectral interferences from additives in the suspension are observed. The validated model was used for the quantification of a commercial suspension (150 mg in 1.0 ml) of the commercialized preparations. The same standards and samples were used, respectively, for the development and validation of a simple linear regression model and for the quantitative determination by means of HPLC-with sample preparation-as described for the related substances of MPA in the Ph. Eur. IV. The quantification results obtained by the FT-Raman method corresponded with the claimed label concentration (150.01+/-0.96 mg/ml (n=6)). Applying the HPLC method, however, a systematic error was observed (157.77+/-0.94 mg/ml (n=6)). The direct FT-Raman method hence appears the most reliable for the quantification of the MPA component in suspension, compared to the HPLC method that requires sample preparation. The latter method provides a systematic error because the exact volume or density of a suspension sample is unknown. A precise isolation of fixed volumes from a suspension is rather unfeasible because of the continuous sagging of the suspended particles and their sticking to the used materials in the isolation process.

Chromatography, High Pressure Liquid↗

Development of a laboratory robotic system for automated bioanalytical methods--II. A robot computer program for guarding totally automated bioanalytical methods.

The application of fully automated, unattended sample preparation performed by a laboratory robot for the analysis of drugs in biological samples requires the prevention of system failures which may arise in the on-line coupled chromatographic system or in other components of the robotic system. A computer program has been developed which can help to detect such problems. The control program for the robotic sample preparation contains a number of safety measures to intercept robotic or human errors. A routine is implemented, guarding for chromatographic malfunctions and errors in dispensing liquids by the robot. After detection of trouble, sample preparation is interrupted.

Algorithms↗

Characterization of amyloid structures at the molecular level by solid state nuclear magnetic resonance spectroscopy.

Solid state nuclear magnetic resonance (NMR) spectroscopy is particularly useful in structural studies of amyloid fibrils because solid state NMR techniques have unique capabilities as site-specific, molecular-level structural probes of noncrystalline materials. These techniques provide experimental data that strongly constrain the secondary, tertiary, and quaternary structures of amyloid fibrils, permitting the development of experimentally based structural models. Examples of techniques that are applicable to amyloid samples prepared with isotopic labeling of specific sites and to samples prepared with uniform isotopic labeling of selected residues are presented, illustrating the utility of the various techniques and labeling schemes. Information regarding the preparation of amyloid samples for solid state NMR measurements is also included.

Amyloid↗

Assay of riboflavin in sample wines by capillary zone electrophoresis and laser-induced fluorescence detection.

To routinely assay the concentration of riboflavin (RF) in wines, a rapid and sensitive method was developed and evaluated. The method is based on a simple sample preparation, capillary zone electrophoretic separation and laser-induced fluorescence detection (CZE-LIF). Sample preparation required only dilution and filtration. Under optimized conditions, the limit of detection of riboflavin was 0.5 micro g/L, using a hydrodynamic sample introduction of 10 s at 54 mbar. The method was fully validated: the recovery of RF in wines was >95%. The concentrations of RF within the three sample types of Italian wines investigated here ranged from 69 to 151 micro g/L with a mean value (+/-SD) of 112 +/- 25 micro g/L, from 74 to 193 micro g/L with a mean value of 115 +/- 45 micro g/L, and from 156 to 292 micro g/L with a mean value of 226 +/- 40 micro g/L, for white, rosé, and red wines, respectively. Such an accurate and highly sensitive CZE-LIF method represents a powerful improvement over previous methods in terms of sensitivity, simplicity, and efficiency. It is well suited to satisfy the demands for accurate and sensitive detection with minimal sample preparation and cleanup.

Electrophoresis, Capillary↗

Method to determine 4-oxo-retinoic acids, retinoic acids and retinol in serum and cell extracts by liquid chromatography/diode-array detection atmospheric pressure chemical ionisation tandem mass spectrometry.

Retinoic acid isomers, 4-oxo-retinoic acid isomers and retinol are present in the serum of mammals. In this study a high-performance liquid chromatography (HPLC) separation, sample preparation and tandem mass spectrometry (MS/MS) method was established for quick and easy sample preparation and sensitive determination of retinoids such as all-trans-4-oxo-retinoic acid, 13-cis-4-oxo-retinoic acid, 13-cis-retinoic acid, 9-cis-retinoic acid, all-trans-retinoic acid and retinol in serum and cell extracts. Serum samples were simply treated with three times the volume of isopropanol, dried under vacuum, taken up in the HPLC solvent and immediately put into the autosampler for an automated single-run HPLC analysis. With this MS/MS method we were able to detect 7 pg and quantify 20 pg of all-trans-retinoic acid, 4-oxo-all-trans-retinoic acid and retinol directly on-column and were able to determine a concentration as low as 0.2 ng/mL in ethanolic standards and in biological samples. This method allows ultra-sensitive detection, excellent selectivity and a very simple sample preparation to determine retinoic acids, 4-oxo-retinoic acids and retinol in serum and cell extracts for the study of endogenous retinoids.

Atmospheric Pressure↗

Simplified technique for histochemical determination of three fiber types in equine skeletal muscle.

For determination of 3 muscle fiber types in equine skeletal muscle, a comparison of 2 preincubation buffers, each followed by myosin adenosine triphosphatase staining, was made. Serial sections of the muscle samples (n = 75) were preincubated in an acid buffer (pH 4.6) or a formaldehyde-glycine buffer (pH 7.25) and then were stained for myosin adenosine triphosphatase. Differentiation of muscle fibers into type I, IIA, and IIB was identical with both techniques; however, in the samples prepared at pH 4.6, type I fibers were black; type IIA, light gray; and type IIB, dark gray. In the samples prepared at pH 7.25, types I, IIA, and IIB fibers were white, light gray, and dark gray respectively. The formaldehyde-glycine preincubation buffer (at pH 7.25) gave more consistent results, was easier to prepare, and retained cytoarchitecture better, compared with the samples prepared at pH 4.6.

Adenosine Triphosphatases↗

Sources of variation in the computer-assisted motion analysis of rat epididymal sperm.

Random and nonrandom factors associated with sample preparation and the automated analysis (CellSoft) of rat cauda epididymal sperm motion were studied. Random factors included inherent system variation at both the individual cell level and at the multiple cell level. Repeated analyses of identical tracks across grey level revealed a statistical interaction between grey settings and curvilinear velocity. However, in multiple track analyses, grey level was seen to be a factor only at higher settings. Nonrandom factors included time after sample preparation, dilution medium, and sample preparation procedures. Using a nicked preparation of the entire cauda epididymis from Long-Evans rats, the effects of time were studied on sperm suspended in 1) phosphate-buffered saline + 10 mg BSA/mL, 2) TEST yolk buffer, and 3) Medium 199. In PBS/BSA, the percent motile sperm estimate decreased (50% to 30%) over an hour, while the curvilinear velocity increased (127 to 142 microns/sec). Both sperm motion parameters were maintained in the TEST yolk buffer and in the Medium 199, although at lower values for the latter. Evaluation of the relative contribution of several factors, nested within sample, to the overall variance of three separate motion endpoints revealed that there was a large variation from field to field, negligible variation between overall CellSoft analyses of 200 cells or more, low variation at the preparation aliquot level, and moderate variation at the animal level. In planning experiments to test for effects on sperm motion endpoints, consideration of the relative contribution of the individual study factors to the overall variance of the parameter estimates will result in more sensitive experimental designs.

Animals↗