Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “dynamic range”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59Linked to original sources

Amperometric detection of insulin at renewable sol-gel derived carbon ceramic electrode modified with nickel powder and potassium octacyanomolybdate(IV).

A renewable three-dimensional chemically modified carbon ceramic electrode (CCE) containing nickel powder and K4[Mo(CN)8] was constructed by sol-gel technique. The electrochemical properties and stability of modified electrode was evaluated by cyclic voltammetry in pH range 4-10. The redox couple of [Mo(CN)8] (4-/3-) was shown both as a solute in electrolyte solution and as a component of a carbon based conducting composite electrode. The apparent electron transfer rate constant (ks) and transfer coefficient (alpha) were determined by cyclic voltammetry and they were about 17.1 and 0.57 s(-1), respectively. The catalytic activity of the modified CCE toward insulin oxidation was investigated at pH range of 3-8 by cyclic votammetry. The modified electrode showed excellent electrocatalytic activity toward insulin electroxidation at physiological pH value. The modified electrode was used for insulin detection chronoamperometrically at pH 7. Under optimized condition in amperometry method, the concentration calibration range, detection limit and sensitivity were 0.5-500 nM, 0.45 nM and 6140 nA/microM, respectively. Flow injection amperometric determination of insulin at pH 7.4, at this modified electrode yielded a calibration curve with the following characteristics, linear dynamic range 100-500 pM; sensitivity 8.1 nA/nM and detection limit 40 pM (based on S/N = 3). The inherent stability at wide pH range, high sensitivity, low detection limit, low cost and ease of preparation are of advantageous of this insulin sensor. This sensor indicates great promise for monitory insulin in chromatographic effluents.

Animals↗

Neural contributions to the perstimulus compound action potential: implications for measuring the growth of the auditory nerve spike count as a function of stimulus intensity.

The perstimulus compound action potential (PCAP), unlike the more familiar compound action potential (CAP), can be recorded in response to asynchronous as well as synchronous auditory nerve activity. When all neurons contribute equally to the PCAP, the area under the PCAP (the PCAP area) is proportional to the number of action potentials fired by auditory nerve neurons (the auditory nerve spike count). The auditory nerve spike count is one proposed code for stimulus intensity, and our goal is to use the PCAP to test this hypothesis. In this study, two independent tests were developed to measure the contributions of neurons to the PCAP as a function of their characteristic frequency (CF). The test results were verified using a model of the auditory periphery designed to calculate the auditory nerve spike count as a function of pure tone intensity and frequency. In nearly all experiments, neurons having CFs that span contiguous three or four octave bands contribute equally to the PCAP. For pure tones that stimulate only those neurons contributing equally to the PCAP, the PCAP area grows over intensity ranges frequently exceeding 80 dB, and in one case equaling 108 dB. These results demonstrate that the auditory nerve spike count, at least for pure tones, is capable of encoding changes in stimulus intensity over the entire dynamic range of the auditory system.

Animals↗

Adaptive neural coding dependent on the time-varying statistics of the somatic input current.

It is generally assumed that nerve cells optimize their performance to reflect the statistics of their input. Electronic circuit analogs of neurons require similar methods of self-optimization for stable and autonomous operation. We here describe and demonstrate a biologically plausible adaptive algorithm that enables a neuron to adapt the current threshold and the slope (or gain) of its current-frequency relationship to match the man (or dc offset) and variance (or dynamic range or contrast) of the time-varying somatic input current. The adaptation algorithm estimates the somatic current signal from the spike train by way of the intracellular somatic calcium concentration, thereby continuously adjusting the neurons' firing dynamics. This principle is shown to work in an analog VLSI-designed silicon neuron.

Adaptation, Physiological↗

Segregation of stimulus phase and intensity coding in the cochlear nucleus of the barn owl.

The cochlear nucleus of the barn owl is composed of two anatomically distinct subnuclei, n. magnocellularis (the magnocellular nucleus) and n. angularis (the angular nucleus). In the magnocellular nucleus, neurons tend to respond at a particular phase of a stimulus sine wave. Phase locking was observed for frequencies up to 9.0 kHz. The intensity-spike count functions of magnocellular units are characterized by high rates of spontaneous activity, a narrow range of intensities over which spike counts changed from spontaneous to saturation levels, and a small increase in spike counts with intensity over that range. In the angular nucleus, neurons showed little or no tendency to respond at a certain sinusoidal phase, although some showed weak phase locking for frequencies below 3.5 kHz. Angular units typically had low spontaneous rates, large dynamic ranges, and large increases in spike counts with intensity, resulting in high saturation levels. The clear difference between the two nuclei in sensitivity to both phase and intensity and the reciprocity in response properties support the hypothesis that each nucleus is specialized to process one parameter (phase or intensity) and not the other.

Animals↗

The amplitudes of unit events in Limulus photoreceptors are modulated from an input that resembles the overall response.

Light adaptation is a gain-control process that endows photoreceptors with large dynamic range. In invertebrates, this process appears to be mediated by a negative feedback that sets the amplitude of the isolated photon responses (bumps) by modulating an enzyme's rate of catalysis. This paper reports measurements of the feedback dynamics of Limulus from the responses to small modulations in light intensity. The responses show a noise that apparently arises from the random arrival of photons. We use a dynamic noise-analysis technique to extract the cell's frequency-response transfer function for bump amplitude. Its ratio to the transfer function for the summed response of the cell has a simple form at low frequencies. This indicates that the origin of the feedback responsible for the adaptation is at a stage temporally close to the final conductance response. Moreover, the form of the transfer function suggests feedback by a chemical agent which is removed by a single enzymatic-like stage at low light intensity and by several such stages in parallel but with a spread of time constants at high intensity.

Adaptation, Ocular↗

Characterization of a range of fura dyes with two-photon excitation.

Two-photon excitation (TPE) spectra of Fura-2, -4F, -6F, -FF, and Furaptra were characterized using a tunable (750-850 nM) ultra-short pulse laser. Two-photon fluorescence of these dyes was studied in free solution and in the cytosol of isolated rabbit ventricular cardiomyocytes. The TPE spectra of the Ca(2+)-free and Ca(2+)-bound forms of the dyes were measured in free solution and expressed in terms of the two-photon fluorescence cross section (Goppert-Meyer units). The Fura dyes displayed the same Ca(2+)-free TPE spectrum in the intracellular volume of permeabilized and intact cardiomyocytes. Fluorescence measurements over a range of laser powers confirmed the TPE of both Ca(2+)-free and Ca(2+)-bound forms of the dyes. Single-wavelength excitation at 810 nM was used to determine the effective dissociation constants (K(eff)) and dynamic ranges (R(f)) of Fura-2, -4F, -6F, -FF, and Furaptra dyes (K(eff) = 181 +/- 52 nM, 1.16 +/- 0.016 micro M, 5.18 +/- 0.3 micro M, 19.2 +/- 1 micro M, and 58.5 +/- 2 micro M; and R(f) = 22.4 +/- 3.8, 12.2 +/- 0.34, 6.3 +/- 0.17, 16.1 +/- 2.8, and 25.4 +/- 4, respectively). Single-wavelength excitation of intracellular Fura-4F resolved diastolic and peak [Ca(2+)] in isolated stimulated cardiomyocytes after calibration of the intracellular signal using reversible exposure to low (100 micro M) extracellular [Ca(2+)]. Furthermore, TPE of Fura-4F allowed continuous, long-term (5-10 min) Ca(2+) imaging in ventricular cardiomyocytes using laser-scanning microscopy without significant cellular photodamage or photobleaching of the dye.

Animals↗

An evaluation of dynamic lip-tooth characteristics during speech and smile in adolescents.

This retrospective study was conducted to measure lip-tooth characteristics of adolescents. Pretreatment video clips of 1242 consecutive patients were screened for Class-I skeletal and dental patterns. After all inclusion criteria were applied, the final sample consisted of 50 patients (27 boys, 23 girls) with a mean age of 12.5 years. The raw digital video stream of each patient was edited to select a single image frame representing the patient saying the syllable "chee" and a second single image representing the patient's posed social smile and saved as part of a 12-frame image sequence. Each animation image was analyzed using a SmileMesh computer application to measure the smile index (the ratio of the intercommissure width divided by the interlabial gap), intercommissure width (mm), interlabial gap (mm), percent incisor below the intercommissure line, and maximum incisor exposure (mm). The data were analyzed using SAS (version 8.1). All recorded differences in linear measures had to be > or = 2 mm. The results suggest that anterior tooth display at speech and smile should be recorded independently but evaluated as part of a dynamic range. Asking patients to say "cheese" and then smile is no longer a valid method to elicit the parameters of anterior tooth display. When planning the vertical positions of incisors during orthodontic treatment, the orthodontist should view the dynamics of anterior tooth display as a continuum delineated by the time points of rest, speech, posed social smile, and a Duchenne smile.

Adolescent↗

Response properties of neurons in the core of the central nucleus of the inferior colliculus of the barn owl.

The central nucleus of the inferior colliculus (ICC) is particularly important for the processing of interaural time differences (ITDs). In the barn owl, neuronal best frequencies in a subnucleus of the ICC, the ICCcore, span the animal's entire hearing range (approximately equal to 200-10 000 Hz). This means that low-frequency ITD-sensitive ICCcore neurons in the owl can be directly compared to ITD-sensitive mammalian ICC neurons with similar best frequencies as well as to the high-frequency ITD-sensitive neurons usually studied in owls. This report represents a first attempt to systematically describe important physiological properties of ICCcore neurons in the barn owl, with particular attention to the low-frequency region (< 2 kHz). Responses were obtained from 133 neurons or small clusters of neurons; recording sites were confirmed by histological reconstruction of electrode tracks based on electrolytic lesions. Iso-intensity frequency response functions were typically approximately equal to 1 octave wide in the low-frequency range and approximately equal to 1/3 octave wide in the high-frequency range. Most neurons were ITD-tuned; both noise and pure tone stimuli yielded periodic ITD tuning curves with several equivalent response maxima. In most cases ITD tuning curves had a response peak within the barn owl's physiological ITD range. ITD tuning widths were inversely correlated with neuronal best frequency. None of the ICCcore neurons studied were sensitive to interaural level differences. Monaural inputs to ICCcore cells were typically binaurally balanced, i.e. they exhibited similar response thresholds, dynamic ranges, slopes and saturation levels, for both left and right ear monaural stimulation.

Acoustic Stimulation↗

Real-time polymerase chain reaction estimation of bone marrow tumor burden using clonal immunoglobulin heavy chain gene and bcl-1/JH rearrangements in mantle cell lymphoma.

OBJECTIVE: In mantle cell lymphoma (MCL), detection of minimal residual disease in bone marrow (BM) samples by qualitative polymerase chain reaction (PCR) is insufficient to predict relapse. The aim of this study was to evaluate whether a quantitative estimation of tumor burden in consecutive BM samples from MCL patients was feasible and of clinical value. MATERIALS AND METHODS: In combination with standard qualitative PCR, we developed a sensitive and accurate real-time PCR for detection of bcl-1/JH (joining region) rearrangement and used a recently described real-time PCR analysis of clonal immunoglobulin rearrangement. To assess clinical utility, we quantified tumor cells in 27 BM samples from three MCL patients undergoing combined CHOP (cyclophosphamide, doxorubicin [hydroxydaunomycin], vincristine [Oncovin], prednisone) and anti-CD20 antibody treatment and three MCL patients undergoing up-front autologous stem cell transplantation. RESULTS: The approach is capable of detecting tumor cells over a wide range of BM contamination compared to qualitative PCR analysis alone. Tumor burden in consecutive BM samples decreases during therapy and either increases or stabilizes at low levels in patients who relapse or remain in continuous clinical remission, respectively. CONCLUSIONS: Dynamic range estimation of BM tumor burden is feasible in MCL patients undergoing therapy using clonal immunoglobulin heavy chain gene and bcl-1/JH rearrangement-based real-time PCR.

Antibodies, Monoclonal↗

Digital radiography with a large-area, amorphous-silicon, flat-panel X-ray detector system.

RATIONALE AND OBJECTIVES: To investigate the image quality of a digital radiography system with an amorphous-silicon, large-area, digital flat-panel detector. METHODS: A flat-panel detector based on a matrix of amorphous silicon was integrated into a projection radiography system. The scintillator consisted of a layer of structured cesium iodide. The active matrix size of 30002 pixels together with a pixel size of 143 microm provided a large image area of 43 x 43 cm2. Basic image quality parameters such as detective quantum efficiency (DQE) and modulation transfer function (MTF) were measured and compared with those obtained with conventional systems. RESULTS: The measurement of DQE yielded a high value of 70% at zero spatial frequency. At a system dose equivalent to 400 speed, the DQE of the digital system was a factor of two larger than the DQE of a storage phosphor or screen-film system within the entire spatial frequency range between zero and the Nyquist limit of 3.5 line pairs per millimeter. The flat-panel detector furthermore has an MTF that is superior to that in regular screen-film systems and also provides a substantially larger dynamic range. CONCLUSIONS: This new technology demonstrates its potential to provide equal or superior image quality to conventional screen-film systems and to reduce patient exposure to radiation dose. The advantages of digital radiography systems, based on a flat-panel detector as an instant image display, facilitation of work flow in the radiology department, and digital networking and archiving, are well in sight.

Humans↗

Marking hypoxia in rat prostate carcinomas with beta-D-[125I]azomycin galactopyranoside and.

UNLABELLED: The purpose of this study was to determine, with a rodent tumor model, if microelectrode measurements of unmodulated tumor oxygenation predict for the avidity of hypoxic markers to tumor tissue. METHODS: The rapidly growing, anaplastic variant of the Dunning rat prostate carcinoma cell line (R3327-AT) was implanted subcutaneously on the upper backs of Fischer X Copenhagen rats. Approximately 100 measurements of PO2 were obtained from tumors of 5-10 g in animals that were restrained and then subjected to different anesthetic procedures. Values of median PO2 (in mm Hg) and percentage of measurements <5 mm Hg obtained from individual tumors were used to define tumor oxygenation status. The radiodiagnostic hypoxic markers beta-D-iodinated azomycin galactopyranoside (IAZGP) and [99mTc]HL-91 were simultaneously administered to 26 animals whose tumor oxygen levels had been measured. Six hours after marker administration, the animals were killed; tumor, blood, and muscle tissues were sampled; and percentage injected dose per gram (%ID/g*), tumor/blood ratio (T/B), and tumor/muscle ratio (T/M) parameters were determined. Parameters of marker avidity to individual tumors were linearly correlated with microelectrode measurements of tumor oxygenation to determine the significance of inverse associations. RESULTS: The median PO2 of 41 tumors varied from 2.0 to 20.9 mm Hg, with an average value of 7.5 +/- 1.4 mm Hg. Six tumors had unusually high values; that is, >10 mm Hg, and when these were excluded from the analysis, the average median PO2 of the remaining 35 was 4.3 +/- 0.7 mm Hg. When electrode measurements of tumor oxygenation were obtained under conditions of halothane anesthesia with the animals breathing O2, carbogen, or air, median PO2 values increased significantly (P = 0.001). When animals were deeply anesthetized by intraperitoneal injection of ketamine-xylazine, median PO2 values were not significantly different (P = 0.13) from those obtained while the animals were restrained and breathing air. There was no inverse correlation of significance between the electrode measurements of median PO2 and the avidity of beta-D-IAZGP nor [99mTc]HL-91 in this tumor model. The range of median PO2 values in these tumors was at least 3 mm Hg, and the range of hypoxic marker avidity was less than twofold. CONCLUSION: These data demonstrate that microelectrode measurements of rat tumor oxygenation did not correlate with the avidity of the two hypoxic markers, at least in this tumor model. The larger dynamic range of tumor oxygen measurements obtained with microelectrodes might be biased to low values by their necrotic fractions, the zones within solid tumors that contain dead cells and debris that will not be labeled by bioreducible hypoxic markers. Hypoxic marker avidity to individual tumors will have to be validated by other assays that can predict for their radiosensitivity.

Anesthesia↗

Time-based analysis of silver-stained proteins in acrylamide gels.

Silver staining of proteins after PAGE often remains the method of choice in many laboratories. Nevertheless, it is known that quantification of protein levels is keenly restricted to a small range of protein concentrations leading to an over- or underestimation of protein amounts. To overcome this, a time-based analysis method was developed to avoid the saturation effect of the silver-staining reaction, thus resulting in an improved dynamic range of the gel image produced and therefore better quantification of proteins. Instead of the well-known end-point image analysis, gray intensities of time series images of a developing gel are determined and times until a threshold gray value is reached are calculated. These times are used to calculate a new grayscale image which can be analyzed using commercial image processing software.

Animals↗

Screening analysis of pesticide residues in plant foodstuffs by capillary gas chromatography using the DFG multiresidue method S19: a comparison of customary detection by ECD/NPD with the novel atomic emission detector (AED).

Over a period of 7 months nearly 240 plant foodstuffs taken fresh from the market were analysed for pesticide residues using the Deutsche Forschungsgemeinschaft (DFG) multiresidue method (MRM) S19. The analysed foodstuffs were a representative cross-section of different fruits and vegetables offered on sale on the German market. With the slightly modified MRM S19, up to 400 pesticides and metabolites amenable to gas chromatography (GC) can be determined. The screening analysis was performed with the combination GC-electron-capture detector (ECD)/nitrogen-phosphorus detector (NPD) as well as with the combination GC-atomic emission detector (AED) in parallel. Results obtained from both screening systems agree over the whole concentration range observed. With so-called "problem foodstuffs" the combination GC-AED is clearly more suitable. Confirmation of positive results was performed by GC-mass spectrometry (MS) analysis. On account of its higher selectivity and its wide linear dynamic range down to the lowest detectable concentrations, the GC-AED system produces more reliable quantitative results compared to those obtained from the GC-ECD/NPD system.

Chromatography, Gas↗

Development of highly selective and stable potentiometric sensors for formaldehyde determination.

Two types of biosensors selective to formaldehyde have been developed on the basis of pH-sensitive field effect transistor as a transducer. Highly or partially purified alcohol oxidase (AOX) and the permeabilised cells of methylotrophic yeast Hansenula polymorpha (as a source of AOX) have been used as sensitive elements. The response time in steady-state measurement mode is in the range of 10-60 s for the enzyme-based sensors and 60-120 s for the cell-based sensor. When measured in kinetic mode the response time of all biosensors developed was less than 5 s. The linear dynamic range of the sensor output signals corresponds to 5-200 mM formaldehyde for highly and partially purified alcohol oxidase, and 5-50 mM formaldehyde for the cells. The operational stability of the biosensors is not less than 7 h, and the relative standard deviation of intra-sensor response is approximately 2 and 5% for the enzyme- and cell-based sensors, respectively. When stored at 4 degrees C, the enzyme and cell sensor responses have been found stable for more than 60 and 30 days, respectively. Both types of biosensors demonstrate a high selectivity to formaldehyde with no potentiometric response to primary alcohols, including methanol, or glycerol and glucose. The possible reasons of such unexpected high selectivity of AOX-based FET-sensors to formaldehyde are discussed. The influence of the biomembrane composition and the effect of different buffers on the sensor response to formaldehyde are also discussed.

Alcohol Oxidoreductases↗

Determination of morphine, morphine-3-glucuronide, and morphine-6-glucuronide in plasma after intravenous and intrathecal morphine administration using HPLC with electrospray ionization and tandem mass spectrometry.

High-performance liquid chromatography (HPLC) coupled to atmospheric pressure ionization (API) mass spectrometry (MS) has become a useful technique in the direct analysis of low concentrations of conjugated opiate metabolites. Previous methods using HPLC with traditional detection methods do not have the sensitivity to detect low concentrations of most conjugated drug metabolites. Methods using gas chromatography-mass spectrometry (GC-MS) require hydrolysis and derivatization of the sample followed by an indirect quantitation of conjugated metabolites. Recently, several reports have described direct analysis of opiates and their glucuronide conjugates by HPLC and API-MS. These methods report lower limits of detection than GC-MS methods and quantitation in the low nanogram-per-milliliter range for the glucuronide metabolites of morphine. This report describes an HPLC-electrospray-MS-MS method capable of detecting subnanogram concentrations of morphine (MOR) and its 3- and 6-glucuronide metabolites (M3G and M6G, respectively). The assay has a dynamic range of 250-10,000 pg/mL for M3G and M6G and 500-10,000 pg/mL for MOR. Inter- and intra-assay precision and accuracy varied by less than 8% for all analytes at 750-, 2500-, and 7500-pg/mL concentrations. This assay was used for the determination of MOR, M3G, and M6G in human plasma after intravenous (i.v.) and intrathecal (i.t.) administration of MOR and its effects on the ventilatory response to hypoxia. Peak plasma concentrations of MOR and M6G were measured 1 h after i.v. administration of MOR. Peak concentrations of M3G were measured 2 h after i.v. administration of MOR. After i.t. administration of MOR, peak concentrations of M3G were measured 8 h postdose. MOR was not detected in plasma of patients administered MOR i.t.. Subnanogram concentrations of M6G were measured in the plasma of five of nine patients administered MOR i.t..

Chromatography, High Pressure Liquid↗

Cortical sound processing in children with autism disorder: an MEG investigation.

Previous work investigating frequency encoding mechanisms in human auditory cortex has provided evidence that latency of the auditory evoked M100 is strongly proportional to frequency, with low frequency (100-200 Hz) tones associated with approximately 30 ms longer latencies than mid-range frequency (1-2 kHz) tones. Motivated by pervasive speech and auditory perception deficits observed in autism spectrum disorder, we evaluated M100 frequency dependence in children with autism disorder and typically developing controls. Results indicate that for control children, the dynamic range of frequency modulation was similar to previous reports for healthy adults. Children with autism had a much reduced range of modulation in right hemisphere sites. Findings indicate that frequency encoding mechanisms may follow a differential maturational path in autism spectrum disorder.

Acoustic Stimulation↗

Abnormal dark-adapted ERG in cats heterozygous for a recessively inherited rod-cone degeneration.

PURPOSE: To study retinal function in cats homozygous and heterozygous for a recessively inherited rod-cone degeneration. METHODS: Dark-adapted electroretinograms (ERGs) were performed on early affected, heterozygous (ophthalmoscopically normal), and clinically normal, nonrelated cats. Responses to blue stimuli over a 3.9-log unit range were recorded. RESULTS: Lower b-wave amplitudes than normal were observed in heterozygotes and early affected cats. The amplitudes of the heterozygotes took an intermediate position between normal and early affected cats. Normalized amplitude/intensity data suggest a normal dynamic range in carriers. B-wave implicit times in carriers were comparable to those of normal cats. CONCLUSIONS: These results show that heterozygotes have an altered retinal function, although they are ophthalmoscopically normal. It is difficult to electrophysiologically differentiate heterozygotes from affected cats with the very early stage of retinal degeneration.

Animals↗

The relation between stimulus and response in olfactory receptor cells of the tiger salamander.

1. Olfactory receptor cells were isolated from the adult tiger salamander Ambystoma tigrinum and the current in response to odorant stimuli was measured with the whole-cell voltage-clamp technique while odorants at known concentrations were rapidly applied for controlled exposure times. 2. Three odorants, cineole, isoamyl acetate and acetophenone, were first applied at 5 x 10(-4) M. Out of forty-nine cells tested, 53% responded to one odorant only, 22% to two odorants and 25% to all three odorants. 3. The amplitude of the current in response to a given odorant concentration was found to be dependent on the duration of the odorant stimulus and reached a saturating peak value at 1.2 s of stimulus duration. 4. The current measured at the peak of the response for odorant steps of 1.2 s as a function of odorant concentration was well described by the Hill equation for the three odorants with Hill coefficients higher than 1 and K1/2 (odorant concentration needed to activate half the maximal current) ranging from 3 x 10(-6) to 9 x 10(-5) M. 5. It is concluded that olfactory receptor cells are broadly tuned and have a low apparent affinity for odorants, integrate stimulus information over time, and have a narrow dynamic range.

Acetophenones↗