Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “SPECIMEN HANDLING”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59Linked to original sources

Non-invasive collection of ejaculates from the common marmoset (Callithrix jacchus) using penile vibrostimulation.

Penile vibrostimulation (PVS), a noninvasive repeatable method, has been shown in the squirrel monkey to yield semen of higher quality than rectal probe electro-ejaculation (RPE). The present study aimed at establishing the conditions for PVS to collect ejaculates from marmoset monkeys. Ten adult males were trained on the appropriate handling before each was subject to six to 12 PVS tests. Ejaculation was stimulated using a FertiCare personal vibrator fitted with a 2 cm x 0.5 cm i.d. glass tube. The stimulus was repeatedly applied over a frequency of 75-95 Hz and amplitude of 1-2 mm for up to 20 min. Ejaculates were analyzed for volume, total sperm number, sperm concentration, and proportion of living and motile sperm. Ejaculates were obtained in 31 of 88 PVS tests; 87.1% of the ejaculations occurred at 80-85 Hz frequency and 1-1.5 mm amplitude. In 18 tests ejaculates were produced within 49.7 seconds. Ejaculates were characterized by (mean values): volume 31.9 microl, total sperm number 34.2 x 10(6)/ejaculate, concentration 1,154.2 x 10(6) sperm/ml, live sperm 74.6%, motile sperm 59.6%. Total number and concentration of spermatozoa were significantly enhanced in singly living males. PVS yielded three to four times more spermatozoa than comparable previously published values for RPE. Enhancing the success rate by preselecting males for responsiveness may render PVS the sperm collection method of choice in marmoset monkeys.

Animals↗

Muscle biopsy as a tool in the study of aging.

The needle biopsy procedure provides a minimally invasive means of obtaining small samples of skeletal muscle from human volunteers. Such samples can be used to examine a variety of structural and functional characteristics of muscle, including fiber type and size, capillarization, enzymatic capacities, energy substrate or protein/mRNA concentrations, metabolic responses, and contractile properties. In conjunction with other methods, biopsy sampling can also be used to estimate total muscle mass and fiber number, and to determine rates of protein synthesis and degradation. Optimal handling and storage conditions vary widely, but in general, most of the above measurements can be made using frozen tissue, so that samples can be stored almost indefinitely. The procedure is also safe and generally well-tolerated, making it possible to perform longitudinal studies of the same person. The biopsy technique is therefore well suited for examining the underlying physiological mechanisms responsible for muscle wasting in the elderly, as well as for assessing the effects of nutritional, hormonal, and/or lifestyle (e.g., exercise) interventions intended to combat this problem. Although sample size limitations have been largely overcome by the development of microtechniques, more information is needed on how to minimize the variability introduced by studying only a small fraction of the whole muscle. Studies are also required to determine whether it is sufficient to biopsy only one muscle (and if so, which is optimal), or whether there are differential effects of aging in various muscle groups that would preclude extrapolating from one muscle to all muscles in the body.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Multiplex PCR amplification from the CFTR gene using DNA prepared from buccal brushes/swabs.

Traditionally, DNA used for PCR-based diagnostic analysis has originated from white cells fractionated from whole blood. Although this method yields substantial quantities of DNA, there are some drawbacks to the procedure, including the inconvenience of drawing blood, risk of exposure to blood-borne pathogens, liquid sample handling, and the somewhat involved extraction procedure. Alternatively, DNA for genetic diagnosis has been derived from finger stick blood samples, hair roots, cheek scrapings, and urine samples. Oral saline rinses have also been used extensively as a means of collecting buccal epithelial cells as a DNA source. However, this method still requires liquid sample handling. Herein, we present our results involving the rapid extraction of DNA from buccal cells collected on cytology brushes and swabs for use in PCR reactions, specifically the multiplex amplification of 5 exons within the CFTR gene. The quality of DNA isolated from buccal cells, collected in this manner, has been sufficient to reproducibly support multiplex amplification. Cheek cell samples and the DNA prepared from them as described here are highly stable. The success rate of PCR amplification on DNA prepared from buccal cells is 99%. In a blind study comparing the analysis of 12 mutations responsible for cystic fibrosis in multiplex products amplified with DNA from both blood and buccal cell samples from 464 individuals, there was 100% correlation of results for blood and cheek cell DNA, validating the use of DNA extracted from cheek cells collected on cytology brushes for use in genetic testing.

Base Sequence↗

Stability of plasma human immunodeficiency virus load in VACUTAINER PPT plasma preparation tubes during overnight shipment.

VACUTAINER PPT plasma preparation tubes were evaluated to determine the effects of various handling and shipping conditions on plasma human immunodeficiency virus (HIV) load determinations. Plasmas obtained from PPT tubes stored and shipped under nine different conditions were compared to conventional EDTA tube plasmas stored at -70 degrees C within 2 h after phlebotomy. Compared to viral loads in frozen EDTA plasma, those in PPT tube plasma that was frozen immediately and either separated or shipped in situ were not significantly different. Viral loads in PPT tube plasma after storage for 6 h at either room temperature or 4 degrees C, followed by shipment at ambient temperature or on wet or dry ice, were not significantly different from baseline viral loads in EDTA or PPT plasma. The results of this study indicate that the HIV load in PPT tube plasma is equivalent to that in standard EDTA plasma. Plasma viral load is not affected by storage or shipment temperature when plasma is collected in PPT tubes. Furthermore, plasmas can be shipped in spun PPT tubes, and the tubes provide a safer and more convenient method for sample collection and transport than regular EDTA tubes.

Anticoagulants↗

Quantification of Alzheimer amyloid beta peptides ending at residues 40 and 42 by novel ELISA systems.

BACKGROUND: The amyloid beta (Abeta) peptide is a key molecule in the pathogenesis of Alzheimer's disease. Reliable methods to detect and quantify soluble forms of this peptide in human biological fluids and in model systems, such as cell cultures and transgenic animals, are of great importance for further understanding the disease mechanisms. In this study, the application of new and highly specific ELISA systems for quantification of Abeta40 and Abeta42 (Abeta peptides ending at residues 40 or 42, respectively) in human cerebrospinal fluid (CSF) are presented. MATERIALS AND METHODS: Monoclonal antibodies WO-2, G2-10 and G2-11 were thoroughly characterized by (SPOT) epitope mapping and immunoprecipitation/mass spectrometry. We determined whether aggregation affected the binding capacities of the antibodies to synthetic peptides and whether components of the CSF affected the ability of the antibodies to bind synthetic Abeta1-40 and Abeta1-42 peptides. The stability of Abeta40 and Abeta42 in CSF during different temperature conditions was also studied to optimize sample handling from lumbar puncture to Abeta assay. RESULTS: The detection range for the ELISAs were 20-250 pM. The intra-assay variations were 2% and 3%, and the inter-assay variations were 2% and 10% for Abeta40 and Abeta42, respectively. The antibodies specifically detected the expected peptides with equal affinity for soluble and fibrillar forms of the peptide. The presence of CSF obstructed the recognition of synthetic peptides by the antibodies and the immunoreactivity of endogenous CSF Abeta decreased with increasing storage time and temperature. CONCLUSIONS: This study describes highly sensitive ELISAs with thoroughly characterized antibodies for quantification of Abeta40 and Abeta42, an important tool for the understanding of the pathogenesis of Alzheimer's disease. Our results pinpoint some of the difficulties associated with Abeta quantification and emphasize the importance of using a well-documented assay.

Albumins↗

Preanalytical handling of stored urine samples, and measurement of beta 2-microglobulin, orosomucoid, albumin, transferrin and immunoglobulin G in urine by enzyme-linked immunosorbent assays (ELISA).

Urinary beta 2-microglobulin, orosomucoid, albumin, transferrin and IgG were measured by enzyme-linked immunosorbent assays (ELISA). In urine samples stored at -20 degrees C three of these proteins decreased during the period of freezing. After 1 week at -20 degrees C urinary transferrin decreased by 81%, IgG by 39% and albumin by 26% of the pre-freezing values; however, addition of Tween-20 restored these values. In previously stored urine samples with bovine albumin, the decreased value after freezing at -20 degrees C could be increased by changing the thawing procedure and including addition of Tween-20. Urine samples thawed at room temperature just before analysis decreased by 80% for transferrin, 57% for IgG, 30% for albumin and 26% for beta 2-microglobulin compared with samples thawed at 37 degrees C, had Tween-20 added and then were kept for a few days at room temperature before analysis. Furthermore, previously frozen urine samples that were thawed at 37 degrees C, had Tween-20 added and then were stored at room temperature did not show significant changes in any of the protein results measured the day after thawing and 35 days later. Orosomucoid seemed to be less variable as regards the effect of freezing and thawing procedure.

Adult↗

DNA stabilization is critical for maximizing performance of fecal DNA-based colorectal cancer tests.

We have developed a multitarget, fecal DNA screening assay that detects the presence of gene-specific mutations and long DNA fragments associated with colorectal cancer (CRC). We continue to investigate methods that may be used to optimize clinical sensitivity. The goals of this investigation are to establish how sample handling conditions affect the stability of DNA in stool, thereby potentially limiting clinical sensitivity, and to determine conditions to ameliorate DNA degradation. A study was run comparing paired sample aliquots. Quantitative PCR data for matched aliquots was used to determine first the effect of sample incubation on total recovery and integrity of DNA, then the effect of stabilization buffer addition to stool on recoverable DNA, and finally the impact of buffer addition on assay sensitivity. Comparison of quantitative PCR data for paired aliquots shows that the amount of recoverable human DNA is negatively affected by storing stool samples (N = 43) at room temperature for > or =36 hours (P = 0.0018). However, the addition of stabilization buffer leads to a significant increase in recovery of DNA (P = 0.010), compared with samples incubated without buffer. Whereas the DNA Integrity Assay (DIA) is found to be sensitive to DNA degradation (sensitivity was reduced by 82%; P = 0.0002), point mutation marker sensitivity is more refractory. Overall, DNA can be stabilized by addition of buffer to the sample, leading to increased assay sensitivity.

Buffers↗

Cerebrospinal fluid.

It is hoped that we have demonstrated that collection, handling, and limited analysis of CSF samples from the dog and cat are relatively simple. No special equipment or handling is required, and the procedures are within the capabilities of any veterinarian interested in performing them. In addition, although this article was not intended to present a detailed discussion on the interpretation of the analysis of CSF, we have demonstrated some very practical interpretations to the various aspects of a routine CSF analysis. When combined with a signalment, complete history, and thorough general physical and neurologic examination, CSF analysis can prove invaluable in the workup of an animal with a neurologic disorder. Relatively simple laboratory procedures can be helpful in differentiating peripheral blood contamination from true intrathecal hemorrhage, in identifying an active inflammatory process, in potentially characterizing an etiologic agent, and, on rare occasions, in identifying primary or metastatic neoplastic disease involving the CNS. In many cases, the above is not directly possible, because the changes observed in our routine analysis are nonspecific. Yet, documenting and following these "nonspecific" alterations are helpful in determining if there is progression or regression of the disease process. In turn, these changes or lack of changes are helpful in identifying if the proper therapy has been instituted and if additional or different therapy is required.

Animals↗

Evaluation of the VACUTAINER PPT Plasma Preparation Tube for use with the Bayer VERSANT assay for quantification of human immunodeficiency virus type 1 RNA.

Separation and storage of plasma within 2 h of phlebotomy is required for the VACUTAINER PPT Plasma Preparation Tube (PPT) versus 4 h for the predecessor VACUTAINER EDTA tube for human immunodeficiency virus type 1 (HIV-1) viral load (HIVL) testing by the VERSANT HIV-1 RNA 3.0 assay (branched DNA). The 2-h limit for PPT imposes time constraints for handling and transporting to the testing laboratory. This study compares HIVL reproducibility from matched blood in EDTA tubes and PPTs and between PPT pairs following processing within 4 h of phlebotomy, stability of plasma HIV-1 RNA at 24- and 72-h room temperature storage in the tube, and comparative labor and supply requirements. Blood from 159 patients was collected in paired tubes (EDTA/PPT or PPT/PPT): 86 paired EDTA tubes and PPTs were processed 4 h following phlebotomy and their HIVLs were compared, 42 paired PPT/PPT pairs were analyzed for intertube HIVL reproducibility, and 31 PPT/PPT pairs were analyzed for HIV-1 RNA stability by HIVL. Labor and supply requirements were compared between PPT and EDTA tubes. PPTs produce results equivalent to standard EDTA tube results when processed 4 h after phlebotomy. PPT intertube analyte results are reproducible. An average decrease of 13% and 37% in HIVL was observed in PPT plasma after 24 and 72 h of room temperature storage, respectively; thus, plasma can be stored at room temperature up to 24 h in the original tube. PPTs offer labor and supply savings over EDTA tubes.

HIV-1↗

Importance of preanalytical handling of samples for measurement of cardiac troponin T in coronary effluent from isolated rat hearts.

The isolated, buffer-perfused heart is probably the most widely used model in experimental heart research, and the coronary effluent is often analysed for markers of myocardial injury. Adsorption to surrounding materials may be a serious problem of protein measurements in solutions with low protein concentrations. The aims of the present study were to investigate the importance of the preanalytical phase when measuring cardiac troponin T (cTnT) in a buffer perfusate and to investigate whether addition of albumin to the effluent might increase recovery of cTnT and improve the assay. Coronary effluent was collected in tubes of different materials and in tubes with 40 g/L bovine albumin, and then frozen. cTnT was analysed at different time points after withdrawal from the freezer. cTnT was 2.3-119 times higher in effluent with albumin. In effluent without albumin, cTnT concentration declined to 2% of the initial concentration after two episodes of freezing and thawing. The cTnT loss could not be prevented by using polystyrene or siliconized glass, but was partially inhibited in effluent with albumin. Furthermore, creatine kinase and lactate dehydrogenase levels were higher in effluent with albumin. The within-series coefficient of variation for cTnT was markedly improved when using effluent with albumin.

Adsorption↗

Evaluation of FTA paper and phenol for storage, extraction and molecular characterization of infectious bursal disease virus.

Infectious bursal disease virus (IBDV) is an important poultry pathogen and is distributed world wide that can cause immune suppression and lesions of the bursa of Fabricius. The main component of the virus, VP2, is not only responsible for the bird's immune response, but is important for the molecular identification of this virus as well. The nucleic acid of the virus must be adequately preserved to be analyzed by reverse-transcriptase PCR (RT-PCR) and sequenced for the molecular characterization of the field strain. Phenol inactivation has been the standard for IBDV tissue collection and international shipment; however, there have been some reports of interference with molecular detection capabilities when using phenol. Phenol is also a hazardous chemical and must be handled and shipped carefully. The ability to use the Flinders Technology Associates filter paper (FTA card) for inactivation of several avian pathogens has been proven previously, however no work has been published on its use in IBDV nucleic acid detection. Bursas from experimentally infected birds was imprinted on FTA cards, and then placed in phenol. Samples were evaluated and compared based on molecular detection capabilities between the two inactivation methods. The nucleic acid of the virus was detected in 85% of the FTA card inactivated samples compared to 71% in the phenol inactivated samples. Sequence analysis was performed on samples inactivated by both methods and no differences were found. When comparing the RNA stability at different temperatures, euthanized IBDV infected birds were held at two different temperatures before sampling. No differences were detected for FTA sampling; however, for tissues in phenol the nucleic acid was only detectable up to 2 h post-mortem in the tissues held at 4 degrees C prior to sampling. These findings indicate that the FTA card is an efficient and reliable alternative collection method for molecular detection and characterization of IBDV.

Animals↗

Application of sterilised human amnion for reconstruction of the ocular surface.

BACKGROUND: Despite improved surgical techniques and the use of new medication, healing of corneal and conjunctival defects cannot always be achieved. In this connection the clinical use of human amnion, produced by different techniques, has represented a successful alternative for the past ten years. The purpose of the present investigation was the development of a clinically secure, therapeutically efficient, and easy-to-handle (transport, storage, application) allogenic amnion transplant. PATIENTS AND METHODS: A new method for an amnion preparation, which contains a sterilisation process in peracetic acid and a drying process in a laminar flow cabinet, was developed as an alternative to previous techniques described in the literature. Amnion transplantation was used to treat 41 patients, 36 of them with corneal ulcer. Further indications for amnion transplantation were symblepharon, descemetocele, as well as dehiscence of conjunctiva after cerclage. RESULTS: Seventy-three percent of cases showed postoperative improvement evidenced by constant vision, while 15 percent showed decreased vision. CONCLUSIONS: The study confirms the observations of previous investigators who consider amnion transplantation an efficient therapeutic method for a multitude of eye diseases. The new method described in this report, guarantees patients' safety by using a validated new sterilisation process against infections that can be transmitted by human tissue. At present this method constitutes the only process available in Germany, and is approved by the Federal Institute for Drugs and Medical Products (BfArM) for the manufacture of human amnion transplants as a finished medical product.

Adult↗

Nanoliter dispensing for uHTS using pin tools.

Miniaturization of assays is an important objective in Ultra-HTS. One of the major obstacles has been to find fluid handling systems capable of reliably and accurately delivering between 2 and 200 nl of test compound to assay plates. New methods of forming pins, placing slots in the pins, and hydrophobic coatings bonded onto the pins solve many of the problems encountered by early pin tools. Unlike other low-volume liquid handlers, these new pin tools provide the ability to transfer approximately 2 nl-5 microl of compounds. These pin tools can also use low-volume source plates (2-10 microl) and achieve an accuracy of better than 5%. This, coupled with the ability to transfer small volumes directly from the compound library to assay plates without an intervening dilution plate, saves reagents, throughput time, and consumables and is, therefore, very cost effective. Pin tool compound transfers in the 2-100 nl range provide a simple method to dilute away from the toxic effect that dimethyl sulfoxide has on some assay target cells. The factors that affect liquid transfers by pin tools are discussed in detail as well as the advantages and limitations of pin tools.

Biological Assay↗

Precise nanoliter fluid handling system with integrated high-speed flow sensor.

A system for accurate low-volume delivery of liquids in the micro- to nanoliter range makes use of an integrated miniature flow sensor as part of an intelligent feedback control loop driving a micro-solenoid valve. The flow sensor is hydraulically connected with the pressurized system liquid in the dispensing channel and located downstream from the pressure source, above the solenoid valve. The sensor operates in a differential mode and responds in real-time to the internal flow-pulse resulting from the brief opening interval of the solenoid valve leading to a rapid ejection of a fluid droplet. The integral of the flow-pulse delivered by the sensor is directly proportional to the volume of the ejected droplet from the nozzle. The quantitative information is utilized to provide active control of the effectively dispensed or aspirated volume by adjusting the solenoid valve accordingly. This process significantly enhances the precision of the fluid delivery. The system furthermore compensates automatically for any changes in the viscosity of the dispensed liquid. The data delivered by the flow sensor can be saved and backtracked in order to confirm and validate the aspiration and dispensing process in its entirety. The collected dispense information can be used for quality control assessments and automatically be made part of an electronic record.

Biological Assay↗

Laboratory findings in urinary tract infections.

Urinary tract infection should be considered in a differential diagnosis on the basis of history, physical examination, and urinalysis. To definitively diagnose urinary tract infection, significant bacteriuria must be found by quantitative bacterial culture. The absolute definition of significant numbers of bacteria varies with the method of collection because of the possibility of contamination with the normal bacterial flora of the lower genitourinary tract. Numbers of bacteria are also influenced by the manner in which urine samples are handled, by urine concentration, and by frequency of voiding. Quantitative and qualitative urine cultures should also be used to monitor the efficacy of treatment in chronic and recurrent infections. Cultures should be repeated three to five days after the termination of antimicrobial therapy to ensure elimination of infection. If feasible, cultures should also be repeated two to three days after begining therapy to ensure the antimicrobial agent selected is effective. Remission of clinical signs should not be used to judge efficacy of treatment, especially in chronic or recurrent infections, since infections can persist without causing clinical signs, particularly if bacterial numbers are temporarily reduced. Determination of the minimum inhibitory concentration of an antibiotic for a particular bacteria is preferable to Kirby-Bauer antibiotic sensitivity testing in urinary tract infection because of the difference in serum and urine concentrations of most antibiotics. Bacteria are not sensitive or resistant to an antibiotic but rather to a concentration of that antibiotic. If Kirby-Bauer sensitivity testing is used for urinary tract infection, results must be interpreted carefully since drugs reported as ineffective may be effective in vivo.

Animals↗

Automated liquid chromatographic determination of atenolol in plasma using dialysis and trace enrichment on a cation-exchange precolumn for sample handling.

A fully automated method involving dialysis combined with trace enrichment was developed for the liquid chromatographic (LC) determination of atenolol, a hydrophilic beta-blocking agent, in human plasma. The plasma samples were dialysed on a cellulose acetate membrane and the dialysate was reconcentrated on a short trace enrichment column (TEC) packed with a strong cation-exchange material. All sample handling operations can be executed automatically by a sample processor (ASTED system). After TEC conditioning, the plasma sample, to which the internal standard (sotalol, another hydrophilic beta-blocker) was automatically added, was introduced in the donor channel and dialysed in the static/pulsed mode. The dialysis liquid consisted of 4.3 mM phosphoric acid. When the dialysis process was discontinued, the analytes were eluted from the TEC in the back-flush mode by the LC mobile phase and transferred to the analytical column, packed with octyl silica. The LC mobile phase consisted of phosphate buffer, pH 7.0-methanol (81:19; v/v) with 1-octanesulfonate. Atenolol and the internal standard were monitored photometrically at 225 nm. The different parameters influencing the dialysis and trace enrichment processes were optimised with respect to analyte recovery. The influence of two different kinds of cation-exchange material on analyte recovery and peak efficiency was also studied. The method was then validated in the concentration range 25-1000 ng/ml. The mean recovery for atenolol was 65% and the limit of quantitation was 25 ng/ml.

Adrenergic beta-Antagonists↗

Effects of sample handling on adrenocorticotropin concentration measured in canine plasma, using a commercially available radioimmunoassay kit.

A commercially available radioimmunoassay (RIA) kit for measurement of human adrenocorticotropin (hACTH) was validated for use in dogs. Assay sensitivity was 3 pg/ml. Intra-assay coefficient of variation (x 100; CV) for 3 canine plasma pools was 3.0 (mean +/- SD, 33 +/- 0.99 pg/ml), 4.2 (71 +/- 2.4 pg/ml) and 3.7 (145 +/- 3.7 pg/ml) %. Interassay CV for 2 plasma pools measured in 6 assays was 9.8 (37 +/- 3.6 pg/ml) and 4.4 (76 +/- 3.4 pg/ml) %, respectively. Dilutional parallelism was documented by assaying 2 pools of canine plasma at 3 dilutions and correcting the measured result for dilution. Corrected mean concentrations for the first pool were 33 (+/- 0.99), 36 (+/- 4.3), and 33 (+/- 6.8) pg/ml; corrected mean concentrations for the second pool were 145 (+/- 5.4), 141 (+/- 10.8) and 125 (+/- 3.4) pg/ml. Recovery of 1-39hACTH added to canine plasma (6.25, 12.5, 25.0, 50.0, and 100.0 pg/ml) was linear and quantitative (slope = 0.890, R2 = 0.961). To test whether anticoagulant or the protease inhibitor, aprotinin, influences ACTH concentration in canine plasma, ACTH was measured in canine blood collected in 4 tubes containing anticoagulant: heparin (H), heparin + 500 kallikrein inhibitor units (KIU) of aprotinin/ml (HA), EDTA (E), and EDTA + aprotinin (EA). Plasma ACTH concentration was the same when samples containing H and HA, or HA and E were compared, and was significantly (P less than 0.01) lower in samples containing EA.(ABSTRACT TRUNCATED AT 250 WORDS)

Adrenocorticotropic Hormone↗

Sample loss during measurement of airborne antineoplastic agents.

Handling, preparation and administration of antineoplastic drugs are suspected health hazards for hospital and clinic personnel. Measurement of personal and area exposures to such materials in air is difficult because the average concentration is often close to the analytical detection limit. For this reason, and because of the random nature of drug spills and releases, the sampling method of choice typically extends over a 40-hour workweek. In this study a method for monitoring two airborne antineoplastic drugs, fluorouracil and methotrexate, was tested for possible loss of the drug from filters during air sampling. Glass-fiber filters (37 mm) were spiked with known amounts of drug and subjected to the same airflow conditions as are used in workplace sampling. Filter extracts were analyzed using high performance liquid chromatography (HPLC). Losses during storage up to a month were less than 5% for both drugs. Losses during airflow were directly proportional to cumulative air volume, 2% of the amount on the spiked filter/m3 air for fluorouracil and 6%/m3 for methotrexate. Losses during actual collection will be less and ordinarily are not expected to constitute a major hindrance to extended sampling in occupational settings.

Air Movements↗