Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “RADIOGRAPHY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59Linked to original sources

Bedside chest radiography: diagnostic efficacy.

In order to evaluate the efficacy of bedside chest radiography, a prospective study was completed of 140 patients admitted to the surgical and medical intensive care units over a two-month period. A total of 1132 consecutive bedside radiographs was analyzed for malposition of tubes and lines and interval changes in the cardiopulmonary findings. The median number of bedside radiographs per patient was 0.7 per day. Endotracheal or tracheostomy tubes were present in 54% of all examinations; among these 12% were malpositioned. Central venous catheters were present in 47%; among these 9% were malpositioned. Interval changes regarding cardiopulmonary findings (pneumothorax, collapse, diffuse or focal infiltrate, effusion, and congestive heart failure) were present in 44% of the radiographs after the admission one. Overall there were new findings or changes affecting the patient's management present in 65% of the radiographs. The use of bedside radiography appeared to be appropriate.

Adult↗

Subacute and chronic bone infections: diagnosis using In-111, Ga-67 and Tc-99m MDP bone scintigraphy, and radiography.

The usefulness of indium-111 white blood cell scintigraphy in the diagnosis of subacute or chronic bone infection was examined in 21 orthopedic patients. In-111 WBC imaging was compared with gallium-67 and technetium-99m methylene diphosphonate skeletal scintigraphy and bone radiography, all studies being performed within 1 week. In-111 WBC scintigraphy showed no definite advantage over Ga-67 scintigraphy in the identification of chronic bone infection. The two tests had the same sensitivity (80%) and similar specificity (In-111 WBC 75%, Ga-67 83%; difference not significant). Bone radiography had a sensitivity of 60% and a specificity of 67%. A negative Tc-99m MDP bone scintigram ruled out infection (sensitivity 100%), but because of low specificity (25%), final evaluation required performance of Ga-67 or In-111 WBC scintigraphy.

Adult↗

Digital and conventional chest images: observer performance with Film Digital Radiography System.

The Film Digital Radiography System (FilmDRS) is a device with a laser optical film digitizer, 2,000 X 2,000 X 12-bit memory, and a 1,000-line video display. To evaluate the adequacy of this device for general radiography of the chest, four readers independently analyzed both radiographs and the corresponding video display of the digitized chest images of 150 patients, consisting of 100 images of abnormalities and 50 normal images. The overall results indicate equal sensitivity for the two systems. The FilmDRS, with interactive windowing, proved superior in the detection of hilar and mediastinal disease. X-ray film was superior in allowing detection of hyperlucent states. There was equivalent sensitivity for other disease categories. Superior specificity was achieved with conventional radiographs.

Analog-Digital Conversion↗

Digital projection radiography of the chest.

Direct and film-based radiographic systems are undergoing evaluation by observer performance studies for use in digital imaging of the chest. Many issues intrinsic to digital imaging are not settled, including the minimal pixel size necessary for images of accurate diagnostic quality, the characteristics of the display console, and the usefulness of digital imaging processing techniques. The chest is a particularly difficult anatomic region for examination by digital radiography because of the broad spectrum of disease findings encountered. These issues are discussed in reference to four reports that use observer performance tests for evaluating various facets of chest diagnosis using digital radiography.

Analog-Digital Conversion↗

Calcification in pulmonary nodules: detection with dual-energy digital radiography.

The authors undertook a clinical study to determine the accuracy of dual-energy digital radiography in revealing nodule calcification because calcification in a pulmonary nodule almost excludes the possibility of malignancy. Over a 6-month period, 61 patients with pulmonary nodules (less than or equal to 3 cm) or masses (greater than 3 cm) were examined on a prototype scanned projection unit using a dual-energy detector. In 49 of 61 patients, nodules were noncalcified, and in 12, they were calcified. In 57 patients, the benignancy or malignancy of nodules was established beyond reasonable doubt by pathologic confirmation in 38 and by strong inference in 19 (four patients with noncalcified solitary pulmonary nodules either refused further investigation or surgery or their follow-up was too short to permit exclusion of malignancy). Dual-energy radiography was found to be highly accurate in assessing the presence or absence of calcification in pulmonary nodules and thus in determining their benignancy or possible malignancy.

Adult↗

Peptic ulcer and gastric carcinoma: diagnosis with biphasic radiography compared with fiberoptic endoscopy.

The diagnostic value of biphasic radiographic examination of the stomach and duodenum was compared with that of fiberoptic endoscopy in a prospective, blinded study of 385 patients with dyspepsia. This investigation was directed at gastric malignancies and peptic ulcers. Methodologically there is no absolute standard for a study of this kind because histologic examination is useful for detection of cancer but inadequate for ulcers. As an alternative, kappa indexes and the sensitivity and specificity, as derived by Hui and Walter, were calculated and compared. For the detection of gastric carcinoma, radiographic and endoscopic findings had almost perfect agreement beyond chance. For gastric ulcers, radiography and endoscopy had substantial agreement, which became perfect if small ulcers (less than 5 mm) were excluded. For duodenal ulcers, radiography had a lower sensitivity than endoscopy; this disagreement disappeared if small ulcers were excluded. Both methods have equal merit; choice of the initial diagnostic procedure will therefore depend on cost, discomfort to the patient, and risk of complications.

Female↗

Small bowel radiography: how, when, and why?

Since the advent of endoscopy for evaluating the upper and lower gastrointestinal (GI) tracts, it has become clear that only in the small bowel does barium radiography remain unchallenged. Regrettably, barium examination of the small bowel has traditionally been regarded by many radiologists as a study of minor importance. Small bowel follow-through techniques and enteroclysis methods differ in their diagnostic purpose, potential, and methods of performance. This review examines in detail the spectrum of barium examination techniques currently available for evaluating the small bowel. The benefits of enteroclysis in the majority of clinical situations requiring contrast examination of the small bowel are stressed. Radiologists play the crucial role in the diagnostic evaluation of the small bowel and should strive to refine and advance the accuracy of small bowel radiography.

Administration, Oral↗

Illusory consolidation of the left lower lobe: a pitfall of portable radiography.

The definition of the left hemidiaphragm is frequently lost when patients are evaluated with portable radiographic equipment. Experimental evidence, based on results of radiography and subsequent sagittal sectioning of a frozen, unembalmed human thorax, corroborated the authors' hypothesis that this finding is related to loss of tangential imaging of the apex of the hemidiaphragm due to cephalic angulation of the central beam accompanied by projection of extrapleural fat onto the base of the left lung. In eight of ten patients in whom portable radiography was performed in 10 degrees-15 degrees of lordosis, varying degrees of loss of definition of the left hemidiaphragm were seen, in the absence of disease. This potential pitfall can be avoided by ensuring that the central beam is tangent to the hemidiaphragm. To do otherwise can create the false impression of disease in the left lower lobe, pleural space, or both.

Adipose Tissue↗

High-altitude pulmonary edema: findings at high-altitude chest radiography and physical examination.

Twenty-five male volunteers underwent chest radiography at 550 m above sea level (baseline) and at 4,559 m at 6, 18, and 42 hours after arrival. Nine had a history of high-altitude pulmonary edema (HAPE). Starting by 6 hours and independent of the consecutive presence of HAPE, the diameters of the central pulmonary arteries increased by 10%-30% at 4,559 m. At 18 hours and, increasingly, at 42 hours, radiographic evidence of HAPE developed in eight subjects: six with previously documented HAPE and two without. Radiographic signs of HAPE were most severe peripherally, and morphologic characteristics were compatible with permeability and/or overperfusion edema and normal pulmonary venous pressure. Extensive radiographic findings were accompanied by discrete pulmonary rales, and chest radiography proved valuable in detecting HAPE in subjects with normal findings of lung auscultation. This study demonstrates a significant individual susceptibility of lowland residents with a history of HAPE to develop HAPE, resulting in a recurrence rate of 66%.

Adult↗

Variable compensation technique for digital radiography of the chest.

The authors describe a new technique, variable compensation (VC) radiography, for digital radiography of the chest. It permits retrospective adjustment of image display while maintaining improved mediastinal signal-to-noise ratio (S/N) from aggressive x-ray equalization. A fraction of a logarithmic image representing the profile of the beam intensity incident on the patient is subtracted from a logarithmic equalized image. VC images of a chest phantom were generated with various weightings of the beam-profile image. Edge artifacts were substantially reduced with a weighting of greater than 0.5 and eliminated with a weighting of 1.0. The S/N properties of VC images were measured with a series of plastic squares placed over various regions of the chest phantom. The S/N of the squares in the dense sub-diaphragm were improved twofold compared with the S/N on unequalized radiographs, whereas the S/N in the lung was reduced by 30%. Studies of a volunteer revealed the ability to render images with aggressive equalization (for improved mediastinal visualization) and images with the appearance of traditional chest radiographs.

Humans↗

Digital storage phosphor imaging versus conventional film radiography in CT-documented chest disease.

The advantages of imaging the chest with digital storage phosphor radiography (SR) may be nullified by its spatial resolution, which is lower than that of conventional film radiography (FR). To test the reader detection performance with the two modalities under clinical conditions, the authors compared 140-kVp isoexposure SR (system resolution: 0.2 mm, 10 bits) and FR images of a variety of chest abnormalities proved by computed tomography (CT) (157 patients, 244 abnormalities, 5,652 observations, six readers). In all tests, SR was as good as or better than FR (P less than .05). In overall detection, indicated by the average area of receiver operating characteristics, SR and FR were equivalent. SR was superior for mediastinal lesions and for pulmonary opacities greater than 2 cm in diameter. For all other types of pulmonary lesions and pleural abnormalities, SR and FR were equivalent. Currently available commercial SR systems can replace film radiographic systems in the detection of a wide variety of chest lesions. SR is likely to enable better visualization than FR in the detection of mediastinal and large pulmonary abnormalities.

Female↗

Evaluation of the craniocervical junction in Down syndrome: correlation of measurements obtained with radiography and MR imaging.

Measurement of the atlas-dens interval is the radiographic standard for identification of patients with Down syndrome at high risk for neurologic injury from spinal cord compression. In 17 pediatric patients with Down syndrome, measurements of the atlas-dens interval, distance between the clivus and posterior odontoid process, and width of the neural canal obtained with plain radiographs were compared to predict the width of the subarachnoid space on magnetic resonance (MR) images. In all patients, cervical radiography and craniocervical MR imaging were prospectively performed during lateral flexion and extension. The width of the subarachnoid space was measured with MR imaging. When the 95% confidence interval for correlation coefficients of regression was used, subarachnoid space width on MR images correlated with neural canal width on radiographs better than with either atlas-dens interval or clivus-posterior odontoid process distance (P = .05). Measurement of neural canal width is a better predictor of potential spinal cord compression than the atlas-dens interval or clivus-posterior odontoid process distance and should be emphasized in screening examinations performed with plain radiography.

Adolescent↗

Measurement of scatter fractions in erect posteroanterior and lateral chest radiography.

Scatter fractions (SFs) measured in patients undergoing erect posteroanterior (PA) and lateral chest radiography with a 12:1 antiscatter grid are reported. Modifications to the posterior beam-stop (PBS) technique allowed measurement of scatter in these patients, without altering the diagnostic image and without additional radiation exposure. The SF measurements are reported by anatomic location on 42 clinical chest images. Average SF values ranged from 0.27 to 0.90 on lateral radiographs and from 0.27 to 0.68 on PA radiographs. Scatter measurements with the 12:1 grid were found to be greater than estimates from previous PA chest phantom experiments. To the authors' knowledge, they were the first to measure radiation scatter with the PBS technique in patients undergoing PA and lateral chest radiography with the antiscatter grid.

Adult↗

Pneumonia and ARDS in patients receiving mechanical ventilation: diagnostic accuracy of chest radiography.

This study was done to evaluate the diagnostic accuracy of bedside chest radiography for pneumonia, adult respiratory distress syndrome (ARDS), or both in patients receiving mechanical ventilation. The series consisted of 40 patients; diagnostic accuracy was defined as the area under the receiver operating characteristic curve. Overall diagnostic accuracy for ARDS was 0.84. Overall diagnostic accuracy for pneumonia was 0.52. Review of previous radiographs and knowledge of clinical data did not enhance diagnostic accuracy for ARDS or pneumonia. Diagnostic accuracy for pneumonia was minimally reduced when ARDS was present. There was an increase in false-negative results because the diffuse areas of increased opacity in ARDS obscured the radiographic features of pneumonia. The authors conclude that chest radiography is of limited value for the diagnosis of pneumonia in patients receiving mechanical ventilation. The high false-negative and false-positive ratings for pneumonia resulted in a low diagnostic accuracy. The high diagnostic accuracy for ARDS was primarily due to the well-defined radiographic appearance of ARDS and few false-positive ratings.

Adolescent↗

Technical evaluation of a digital chest radiography system that uses a selenium detector.

PURPOSE: To evaluate a digital chest radiography system that uses a selenium detector. MATERIALS AND METHODS: The relative amounts of scattered radiation in the images (scatter fractions), the effect of x-ray exposure levels on image appearance, the potential "throughput" in a clinical environment, and the effects of image processing options were evaluated. RESULTS: Scatter fractions in digital images acquired with an antiscatter grid were lower in the lung region and higher in the retrocardiac and central mediastinal regions than in conventional images. Digital images acquired without an antiscatter grid had higher scatter fractions in all areas. Increases in exposure intensity reduced the appearance of noise. A new image could be acquired every 37 seconds, and a "preview image" appeared on the monitor after approximately 23 seconds. Laser-printed images were available after at least 5 minutes; the time required increased when many images were acquired in a short time. CONCLUSION: The selenium-based chest radiography system allows for rapid chest examination and excellent image quality when used with an antiscatter grid.

Evaluation Studies as Topic↗

Chest imaging with a selenium detector versus conventional film radiography: a CT-controlled study.

PURPOSE: To compare radiologist detection performance under clinical conditions for assessment of conventional radiographs and digital chest images obtained with a selenium detector. MATERIALS AND METHODS: One hundred four patients were examined with the digital and conventional systems under near identical technical conditions. The digital images were acquired without an antiscatter grid. Two hundred eight images were analyzed by three radiologists for detection of pulmonary, mediastinal, and pleural abnormalities; computed tomography was used as the reference standard. The diagnostic value of both techniques for the detection of these chest abnormalities was analyzed with receiver operating characteristic (ROC) methods. RESULTS: For detection of the various abnormalities by all radiologists, the areas under the ROC curves with conventional imaging versus digital imaging, respectively, were as follows: pulmonary opacities, 0.81 versus 0.79; interstitial disease, 0.69 versus 0.73; mediastinal disease, 0.79 versus 0.74; and pleural abnormalities, 0.73 versus 0.68. CONCLUSION: There was no statistically significant difference between the radiologists' performance in detecting pulmonary, mediastinal, and pleural abnormalities with conventional radiography versus that with digital selenium chest radiography.

Adolescent↗

Measurement of skin entrance exposure with a dose-area-product meter at chest radiography.

Skin entrance exposure measurements obtained with a dose-area-product meter and thermoluminescent dosimeters were compared at posteroanterior and lateral chest radiography in 52 adult male patients. In a linear regression analysis of data collected in both views, values of 1.23 +/- 0.02 and 1.26 +/- 0.01 (r = .98 and .99) were found for the ratios of thermoluminescent-dosimeter and dose-are-product exposures, respectively. Skin entrance exposures from 16 mR (4.13 microC/kg) to 150 mR (38.7 microC/kg) in the posteroanterior view and 24 mR (6.19 microC/kg) to 475 mR (123 microC/kg) in the lateral view were found. Dose-area-product meters offer a rapid and accurate means to measure skin entrance exposure when the radiography field size is known.

Adult↗

US-guided thoracentesis: requirement for postprocedure chest radiography in patients who receive mechanical ventilation versus patients who breathe spontaneously.

PURPOSE: To identify a population of patients who may not need chest radiography after diagnostic thoracentesis by assessing and comparing the pneumothorax rates in patients with mechanical ventilation (intubation) versus spontaneously breathing patients (no intubation). MATERIALS AND METHODS: A retrospective review of all radiographs, clinical records, and ultrasound (US) scans obtained in 434 patients who underwent US-guided thoracentesis was performed. Three hundred forty-two patients were not intubated and 92 were intubated. Nine patients were excluded because of preexisting pneumothorax. The size of the effusion, the needle size used, and whether a pneumothorax occurred after the procedure were determined. RESULTS: Results demonstrated that only 10 pneumothoraces occurred (six in intubated and four in nonintubated patients). None of the nonintubated patients with pneumothorax and two of the six intubated patients with pneumothorax needed chest tubes. The difference in the pneumothorax rate between intubated and nonintubated patients was statistically significant (P < .01). CONCLUSION: Spontaneously breathing patients who undergo diagnostic thoracentesis do not need postprocedure chest radiography.

Adolescent↗