Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Prosthesis Retention”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59Linked to original sources

Similarity of stress distribution in bone for various implant surface roughness heights of similar form.

BACKGROUND: Surface roughness effects on osseointegration can be considered from two viewpoints: purely mechanical effects of stresses attributable to roughness and cell and molecular response to surface roughness. PURPOSE: The goal of this study is to provide a theoretical basis to understand the effects of surface roughness size on the osseointegration of implants. The emphasis is primarily on the purely mechanical effects. METHODS: Mathematical proofs of some similarity principles are provided. RESULTS: The main result is that if the geometric form of the roughness or thread cross-section is held constant, then the peak elastic stress depends on the form but not on the size of the roughness or thread height. CONCLUSION: The purely mechanical effects of surface roughness are well understood on a theoretical basis. The interpretation for clinical procedures, however, needs careful attention. Considering the present state of knowledge and clinical experience, no change in the roughness height of current practice is recommended.

Algorithms↗

Immediate provisional for single-tooth implant replacement with Brånemark system: preliminary report.

BACKGROUND: The success of osseointegrated implants ad modum Brånemark for single-tooth restorations is documented. Future developments should aim at improving the benefits to patients by decreasing treatment time, minimizing surgical stages, and maximizing esthetic outcomes. Using knowledge from studies of immediate implant placement, one-stage, immediate loading protocols, the authors developed the immediate provisional. PURPOSE: The purpose of this study was to develop a protocol to provide an immediate solution for restoring a single missing tooth in the esthetic zone. The protocol should be simple, predictable, cost effective, and allow the use of other techniques to improve esthetic outcome. MATERIALS AND METHOD: This prospective clinical study included 24 patients treated from August 1999 to October 2000. Single-tooth implant replacement was done according to immediate provisional protocol. Thirteen of the 24 patients had immediate implant placement after tooth extraction. All implants were placed in the esthetic zone. During surgery, emphasis was placed on obtaining primary stability by achieving bicortical anchorage and maximum insertion torque of at least 40 Ncm. CeraOne (Nobel Biocare) abutments were used, and provisional crowns were fabricated immediately before wound closure. The occlusion was protected by adjacent teeth. RESULTS: Within the follow-up period of between 1 month and 15 months, all fixtures in the 24 patients were stable. Crestal bone loss greater than one thread-width was not detected. The esthetic result was considered satisfactory by all patients. CONCLUSIONS: The implant placement and restoration protocol used in this study showed promising initial results for both the immediate implant and healed extraction site groups. The desirable goals of patient satisfaction, excellent esthetic outcomes, and no increase in treatment cost were achieved in this protocol. Further studies to elucidate the potential of the immediate provisional protocol are justified.

Adolescent↗

Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: a pilot study.

BACKGROUND: The introduction of resonance frequency analysis (RFA) as a commercially available technique has made it possible to measure implant stability in implant stability quotient (ISQ) units at any time during the course of implant treatment and loading. However, no information on normal ISQ levels can be found in the literature. PURPOSE: The aim of this pilot study was to measure the stability of clinically successful implants in partially edentulous patients after 1 year of loading and to study the influence of jaw, anterior/posterior position, implant length, and marginal bone level on implant stability. MATERIALS AND METHODS: Fourteen partially edentulous patients previously treated with 45 implants were subjected to clinical and radiographic evaluations and RFA measurements using Osstell (Integration Diagnostics, Savedalen, Sweden) after 1 year of loading. RESULTS: All 45 implants were stable, and implant stability levels were in the range of 57 to 82 ISQ units with a mean of 69 +/- 6.5 ISQ after 1 year of loading. Mandibular implants were more stable than were maxillary ones. There were no differences between anterior and posterior implants. No correlation could be found between implant length and stability. Only minor marginal bone resorption was observed. CONCLUSIONS: The results from this limited material showed that successfully integrated implants have ISQ levels from 57 to 82 ISQ with a mean of 69 ISQ after 1 year of loading. Mandibular implants are more stable than are maxillary ones. High implant stability can be achieved with short implants and placement in posterior regions.

Dental Implants↗

One-year prospective three-center study comparing the outcome of a "soft bone implant" (prototype Mk IV) and the standard Brånemark implant.

BACKGROUND: Oral implant treatment ad modum Brånemark has been used for decades in the rehabilitation of edentate and partially dentate patients. Posterior jaw regions frequently exhibit bone of poor texture, and it is often difficult to obtain primary stability. Thus, it may prove beneficial to deviate from the original protocol and to use implants with a modified design, for example, with a slightly tapered geometry. PURPOSE: The purpose of the investigation was to compare the early behavior of a modified (prototype Mk IV, Brånemark System, Nobel Biocare AB, Gothenburg, Sweden; test) implant with that of the standard Brånemark implant (control) in regions of mainly type 4 bone. MATERIALS AND METHODS: Three Swedish centers participated, and a total of 44 patients were treated with oral implants for 39 maxillas and 5 mandibles. The study focused on the most distal right and left implant sites (88 implants), which were randomized to receive either a test or a control implant. Various parameters were recorded, such as registered insertion torque (OsseoCare), Nobel Biocare AB), wobbling during insertion, primary and secondary stability (as measured with resonance frequency), and marginal bone loss. The implants were followed up for 1 year. RESULTS: The test implant more frequently required a higher insertion torque and showed a significantly higher primary stability than the control implant. This difference in stability leveled out over time, and test and control implants exhibited similar secondary stability at abutment operation and at the 1-year visit. Wobbling during insertion was rarely recorded for either of the implant designs. The 1-year cumulative success rate was 93.1% for test implants and 88.4% for control implants. CONCLUSIONS: The modified implant design resulted in an increased primary stability, which may be important when placing implants in jaw regions of type 4 bone. However, independent of the achieved primary stability, successful implants tended to approach similar secondary stability in the two designs tested.

Adult↗

Influence of implant length and bicortical anchorage on implant stress distribution.

BACKGROUND: Short implants present superior failure rates for everybody. PURPOSE: The aim of this theoretic study was to assess to what extent implant length and bicortical anchorage affect the way stress is transferred to implant components, the implant proper, and the surrounding bone. MATERIALS AND METHODS: Stress analysis was performed using finite element analysis. A three-dimensional linear elastic model was generated. All implants modeled were of the same diameter (3.75 mm) but varied in length, at 6, 7, 8, 9, 10, 11, and 12 mm (Brånemark System, Nobel Biocare AB, Gothenburg, Sweden). Each implant was modeled with a titanium abutment screw and abutment, a gold cylinder and prosthetic screw, and a ceramic crown. The implants were seated in a supporting bone structure consisting of cortical and cancellous bone. An occlusal load of 100 N was applied at a 30 degrees angle to the buccolingual plane. RESULTS: With the selected model and bone properties, the coronal cortical anchorage was dominating, and the bone stress concentrated to that area. CONCLUSIONS: The maximum bone stress was virtually constant, independent of implant length and bicortical anchorage. The maximum implant stress, however, increased somewhat with implant length and bicortical anchorage.

Bone and Bones↗

Mk III: a third generation of the self-tapping Brånemark System implant, including the new Stargrip internal grip design. A 1-year prospective four-center study.

BACKGROUND: Many prospective studies have shown predictable long-term results of the Brånemark System (Nobel Biocare AB, Gothenburg, Sweden) turned-surface implants in totally edentulous, partially edentulous, and single cases. The Mk III self-tapping implant was introduced by Nobel Biocare in 1999 as part of a new implant generation that improved on the Mk II self-tapping implant that had been introduced in 1992. A new implant design should always be evaluated, preferably in prospective multicenter studies. PURPOSE: The aim of the present prospective multicenter study was to evaluate the short-term success rate of the Brånemark Mk III machined- and turned-surface self-tapping implant and to evaluate the clinical handling of the new Stargrip (Nobel Biocare AB) internal grip design. MATERIALS AND METHODS: The open prospective 1-year multicenter study was performed at four clinics. Sixty-four patients (38 females, 26 males) with a mean age of 51 years (range, 16 to 80 years) were included. Seventeen of the patients were totally edentulous, 26 were partially edentulous, and 21 had single-tooth losses. In total, 194 Mk III implants were inserted, 89 in the maxillas and 105 in the mandibles. RESULTS: Fifty-eight patients were observed for 1 year after prosthetic loading. Three of 194 implants were lost, corresponding to a cumulative success rate of 98.4% after 1 year, 100% for maxillary implants and 97.1% for mandibular implants. The implant driver carried the implants reliably in 99.5% of all treated patients. Sixty-two patients received the planned prosthetic reconstruction. All but one prosthetic reconstruction survived after 1 year of loading. The mean marginal bone resorption, analyzed from radiographs of 143 implants, was 1.15 mm (standard deviation [SD], 1.09 mm) from the second-stage surgery to the 1-year follow-up. CONCLUSION: The 1-year success rate of the Mk III implant was high, and the clinical handling of the internal grip design (Stargrip) improved the surgical technique and was well appreciated by both surgeons and assisting staff.

Adolescent↗

Cutting torque measurements in conjunction with implant placement in grafted and nongrafted maxillas as an objective evaluation of bone density: a possible method for identifying early implant failures?

BACKGROUND: Bone grafts are frequently used to enable the placement of dental implants in atrophied jaws. The biomechanical properties of bone grafts used in one- or two-stage implant procedures (in comparison with the use of nongrafted bone) are not well known. PURPOSE: The purpose of this study was (1) to measure cutting torques during the placement of self-tapping dental implants in nongrafted bone and in bone grafts, either as blocks or in a milled particulate form, in patients undergoing implant treatment in an edentulous maxilla and (2) to identify implants with reduced initial stability and to correlate these findings with a clinical classification of jawbone quality. MATERIALS AND METHODS: The study included 40 consecutive patients with edentulous maxillas, 27 of whom were subjected to bone grafting prior to or in conjunction with implant placement (grafting group) and 13 of whom received implants without grafting (nongrafted group). Grafted bone from the iliac crest bone was used (1) as onlay blocks, (2) as maxillary sinus inlay blocks, or (3) in particulate form in the maxillary sinus. Implants were placed after 6 to 7 months of healing, except in the maxillary sinus inlay blocks, where implants were placed simultaneously. Cutting torque values were obtained from 113 grafted implant sites and from 109 nongrafted implant sites. RESULTS: Significantly lower cutting torque values were assessed in grafted regions than in nongrafted regions, irrespective of grafting technique. Lower values were also seen for implants placed in block grafts after 6 months when compared to other grafting techniques used. The cutting torque values revealed an inverse linear relation to the Lekholm and Zarb bone quality index. CONCLUSION: The cutting torque values correlated well with the Lekholm and Zarb index of bone quality. Significantly lower cutting torque values were seen in grafted bone than in nongrafted bone.

Alveolar Bone Loss↗

A comparison of two methods of enhancing implant primary stability.

BACKGROUND: Surgical technique and implant design have an effect on the primary stability of oral implants, which in turn increases resistance to implant micromotion during healing. PURPOSE: This study was designed to compare the parameters associated with implant insertion using two different methods of enhancing implant primary stability and to identify any relationship between these parameters and changes in the stability of implants during the initial 6-month healing period following implant insertion. A comparison was made between two methods of enhancing primary implant stability: method 1, standard Brånemark System implants (Nobel Biocare AB, Gothenburg, Sweden) inserted with a technique designed to enhance primary stability, and method 2: Brånemark Mk IV implants (Nobel Biocare AB) inserted according to the manufacturer's instructions. MATERIALS AND METHODS: Thirteen patients were selected for inclusion in the study. A total of 42 implants were placed. Insertion torque data were recorded, and bone quality at the implant site was assessed at implant insertion. Resonance frequency analysis measurements were taken at implant insertion as well as at second-stage surgery 6 months later. RESULTS: A statistically significant difference was recorded between the mean maximum insertion torque for type 4 bone and bone types 2 and 3. No significant difference was recorded between bone types 2 and 3. A significantly lower resonance frequency value was seen for standard implants placed into type 4 bone (p < .05). Across all implant types a significant difference in the energy required when inserting implants into type 4 bone and bone types 2 and 3 was seen. A significantly lower mean energy requirement was seen between the Mk IV implants placed into type 4 bone and the other combinations of implant types and bone. CONCLUSIONS: Within the limitations of this study, the results agree with the manufacturer's claim that when compared with standard implants, the design of the Mk IV implant increases implant primary stability with a reduction in the energy imparted into the bone at the implant site.

Adult↗

Biomechanical measurements of calcium-incorporated oxidized implants in rabbit bone: effect of calcium surface chemistry of a novel implant.

BACKGROUND: In oral implantology there has been a general trend away from machine-turned minimally rough and acid-etched and blasted implants toward intermediary roughened surfaces. Mechanical interlocking at micron resolution is claimed to be the dominant reason for the fixation of such implants in bone. However, clinical demands for stronger and faster bone bonding to the implant (eg, in immediately loaded and compromised bone cases) have motivated the development of novel surfaces capable of chemical bonding. PURPOSE: The purpose of the present study is to investigate bone tissue reactions to a newly developed calciumincorporated oxidized implant. The specific aim is to assess the effect of calcium surface chemistry on the bone response. MATERIALS AND METHODS: Calcium (Ca) ion-incorporated implants were prepared by micro arc oxidation methods. Surface oxide properties were characterized by using various surface analytic techniques involving scanning electron microscopy, x-ray diffractometry, x-ray photoelectron spectroscopy, and optical interferometry. Twenty screw-shaped commercially pure (CP) titanium implants (10 turned implants [controls] and 10 Ca-incorporated implants [tests]) were inserted in the femoral condyles of 10 New Zealand White rabbits. RESULTS: After a healing period of 6 weeks, resonance frequency analyses and removal torque measurements of the Ca-incorporated oxidized implants demonstrated statistically significant improvements of implant integration with bone in comparison to machine-turned control implants (p = 0.013 and p = 0.005, respectively). CONCLUSIONS: The Ca-reinforced surface chemistry of the oxidized implants significantly improved bone responses in a rabbit model. The present study suggests that biochemical bonding at the bone-implant interface, in combination with mechanical interlocking, may play a dominant role in the fixation of Ca-incorporated oxidized implants in bone. The observed rapid and strong integration of test Ca implants may have clinical implications for immediate or early loading and improved performance in compromised bone.

Animals↗

Stability of the implant/abutment joint in a single-tooth external-hexagon implant system: clinical and mechanical review.

Rigorous efforts have recently been made to reduce the recurrence of implant/abutment joint failure in single-tooth implant restorations. However, the current knowledge about the stability of implant/abutment joints in an external hexagon implant system is incomplete. We reviewed clinical data regarding single-tooth implant treatment with Brånemark implants, specifically the CeraOne abutment system (Nobel Biocare AB, Göteborg, Sweden). In vitro studies on joint stability were systematically assessed. Bending overload and the presence of misfit at the implant/abutment joint interface are the critical mechanical conditions that can make the joint unstable. Appropriate joint fitness and proper alignment of the implant should be assessed, and occlusal adjustment by narrowing the restoration width and flattening cuspal inclination should be applied to avoid bending moments caused by the lateral component of occlusal forces. Sufficient clinical reports of longer duration that evaluate and verify longer-term success of the newly manufactured joint components were unavailable.

Dental Abutments↗

Abutment screw loosening and bending resistance of external hexagon implant system after lateral cyclic loading.

BACKGROUND: Rigorous efforts to reduce the recurrence of abutment screw loosening in single-tooth implant restorations have recently been made. However, the behavior of the implant/abutment joint components with respect to critical bending force is still unclear. PURPOSE: This study investigated the effect of different cyclic loading periods on abutment screw loosening and bending resistance of a single-tooth external hexagon implant system. MATERIAL AND METHODS: Fifteen Brånemark implant assemblies were divided equally into groups A, B, and C. Each assembly consisted of a Brånemark System Mk IV 4 x 10 mm implant (Nobel Biocare AB, Gothenburg, Sweden) mounted in a brass block, a CeraOne 3 mm abutment (Nobel Biocare AB), and an experimental cement-retained superstructure. For groups A and B a cyclic load of 50 N was applied centrally and perpendicular to the long axis of the implant. Targets of 1.0 x 10(6) cycles (40 months of simulated function) and 0.5 x 10(6) cycles (20 months of simulated function) were defined for groups A and B, respectively. Group C (control) was left unloaded for the same loading time period as was group B. Reverse torque was recorded before and after loading, and the difference was calculated. After cyclic loading, specimens were mounted in a testing machine, and the yielding and bending strengths were measured. The data were analyzed with one-way analysis of variance and were compared by means of the Tukey test (p < .05). RESULTS: There were statistically significant differences (p < .001) in the reverse torque difference values of group A ([-5.6 to -3.4] +/- 0.86 Ncm) as compared to those of group B ([-2.4 to -1.6] +/- 0.32 Ncm) and group C ([-0.7 to 0.0] +/- 0.26 Ncm). Likewise, group B showed a significant difference compared to group C (p = .002). On the other hand there was no statistically significant difference in the mean values among the test groups in regard to the yielding and bending strengths (p >.050). CONCLUSION: Within the limitations of this study, long-term fatigue significantly affected the reverse torque values under centric lateral load (p <.001) whereas it had no significant effect on the resistance of the implant/abutment joint to static bending.

Analysis of Variance↗

Implant stability during initiation and resolution of experimental periimplantitis: an experimental study in the dog.

BACKGROUND: Histologic studies have demonstrated the possibility to reestablish direct bone-implant contacts after ligature-induced periimplantitis. The influence of the reosseointegration on the stability of implants is not known. PURPOSE: The aim of the present investigation was to study bone tissue and associated implant stability alterations that occurred during induction and resolution of periimplantitis using resonance frequency analysis (RFA), radiography, and histology. MATERIALS AND METHODS: Three implants with smooth (turned) or roughened (SLA) surfaces were placed in each side of the edentulous mandible of four dogs. Experimental periimplantitis was induced for 3 months. Five weeks later, the animals were treated with antibiotics and surgical therapy and were followed for another 6 months. Periapical radiographs and RFA were used to evaluate marginal bone levels and implant stability throughout the study period. After termination, the tissue-implant interface was evaluated by light microscopy in ground sections. RESULTS: There was a linear relationship between radiographic and RFA findings because continuous loss of marginal bone and a decrease in implant stability were observed for both implant surfaces during the periimplantitis period. Antibiotic treatment and surgical therapy resulted in some reosseointegration, which was more marked for the SLA surface. The resonance frequency values corresponded well to the histometric measurements because reosseointegration resulted in an increase in implant stability. CONCLUSIONS: The findings from the present study indicate a linear relationship between marginal bone level and resonance frequency value. It is suggested that the RFA technique is sensitive and may be used to detect even a minor change in the level of bone-implant contact.

Alveolar Bone Loss↗

Oxidized titanium implants in reconstructive jaw surgery.

BACKGROUND: Rehabilitation with implant-supported bridges in patients with insufficient bone volumes may require bone reconstructive procedures in conjunction with or prior to implant placement. Clinical follow-up studies using turned titanium and bone grafts have demonstrated higher failure rates than when used in nongrafted patients. Improved bone integration has been demonstrated for oxidized titanium implants; however, their clinical performance in bone reconstruction situations is not known. PURPOSE: This study was performed to analyze the survival and stability of oxidized titanium implants placed in patients subjected to reconstructive jaw surgery at one clinic. MATERIALS AND METHODS: Two hundred oxidized titanium implants (Mk III, TiUnite, Nobel Biocare AB, Göteborg, Sweden) were placed in 47 patients in conjunction with or secondary to six different reconstructive procedures owing to insufficient bone volume. In all six groups, implant stability was assessed by resonance frequency analysis and manually checked for rotation stability at implant insertion, at the time of abutment connection, and after a minimum of 12 months of loading of the prosthetic construction. Periapical radiographs were taken after a minimum of 12 months of loading (mean 21 months) for evaluation of the marginal bone levels. The mean clinical follow-up period was 30 months. RESULTS: Of the 200 implants, 199 were considered osseointegrated at the time of abutment surgery. At the 12-month postloading follow-up, another two implants were considered not stable. Three implants (1.5%) were ranked as unsuccessful. CONCLUSION: Clinical experience with 200 consecutive oxidized implants in various reconstruction situations shows a successful outcome, with only three failures (1.5%) during a mean follow-up period of 30 months.

Adolescent↗

Correlation between implant stability quotient and bone-implant contact: a retrospective histological and histomorphometrical study of seven titanium implants retrieved from humans.

BACKGROUND: Primary stability has a relevant role in the long-term success of dental implants. A quantitative method for the measurement of implant stability has been introduced (resonance frequency analysis [RFA]). Information about the significance of RFA measurements and about the relationship between RFA values and their association with implant osseointegration, success, or failure is important from a clinical point of view. PURPOSE: The aim of the present histological and histomorphometric study was to see if a correlation existed between the bone-implant contact (BIC) percentage of retrieved human implants and RFA values. MATERIALS AND METHODS: Seven implants inserted in the posterior mandible, with a sandblasted and acid-etched surface and retrieved after a 6-month period, were evaluated in the present study. These seven implants had been retrieved for different causes. All these implants were submerged and were retrieved with a 5-mm trephine bur and immersed in 10% buffered formalin to be processed for histology. RESULTS: A statistically significant correlation could be detected between implant stability quotient and BIC (p=.016). CONCLUSIONS: Even if the relationship between bone structure and RFA is still not fully understood, in our study, a statistically significant correlation was found between RFA and BIC values. Further studies are needed to evaluate a correlation of RFA and BIC in human implants retrieved after a range of healing periods.

Dental Implantation, Endosseous↗

Fabrication of direct fiber-reinforced posts: a structural design concept.

UNLABELLED: As the clinician continues the quest for optimal functional and esthetic success of a tooth-restorative complex, the current selection of restorative materials and techniques may prove overwhelming. Although no single system provides the ideal restorative solution for every clinical circumstance, understanding of general design criteria and the components for the various post and core systems available allow the clinician to appropriately select the method and materials compatible with the existing tooth structure and desired result. This article provides a discussion of the various post and core systems, the methods and materials inherent in these systems, and general design principles. Using that basic information and clinical experience, the authors offer an alternative procedure for the rehabilitation of the intraradicular anatomy of the post-endodontic channel with a direct composite resin--the fiber-reinforced post and core system. CLINICAL SIGNIFICANCE: Using improved restorative materials that stimulate the physical properties and other characteristics of natural teeth in combination with the proper design principles, the clinician can develop a tooth-restorative complex with optimal functional and esthetic results.

Bite Force↗

Kaplan-Meier analysis of dental implant survival: a strategy for estimating survival with clustered observations.

The study's purposes were to estimate dental implant survival in a statistically valid manner and to compare three models for estimating survival. We estimated survival using three different statistical models: (1) randomly selecting one implant per patient; (2) utilizing all implants, assuming independence among implants from the same subject; and (3) utilizing all implants, assuming dependence among implants from the same subject. The cohort was composed of 660 patients who had 2286 implants placed. Due to the high success rates of implants, the five-year survival point and standard error estimates varied little among the three models. Patients at high risk for implant failure (smokers) manifested greater variation in the standard error estimates among the three models, 8.2%, 4.0%, and 5.6%, respectively. To obtain statistically valid survival confidence intervals when performing Kaplan-Meier survival analyses, we recommend adjusting for dependence when there are multiple observations within the same subject.

Dental Implantation, Endosseous↗

Within-subject comparisons of implant-supported mandibular prostheses: evaluation of masticatory function.

In the past, fixed prostheses were believed to be more efficient implant-supported devices than removable types for edentulous patients. However, this hypothesis was never properly tested. Therefore, a within-subject crossover clinical trial was designed in which 145 completely edentulous subjects were tested wearing implant-supported mandibular fixed prostheses and long-bar overdentures. Eight subjects received the fixed appliance first and seven the removable type. The patients' perceptions of various characteristics of the implant-supported prostheses were measured after a minimum of two months' adaptation. Mandibular movements and jaw muscle electromyographic activity were recorded while the patients chewed five standard-sized test foods: bread, apple, hard cheese, sausage, and raw carrot. The prostheses were then changed, worn for the same period of adaptation, and the procedures repeated. There were three test sessions per prosthesis, and each included five trials per food. The measurements were repeated three times at one-week intervals. Mastication time was found to be shorter for three foods (bread, cheese, and sausage) when subjects wore the long-bar overdenture. The vertical amplitude of the masticatory strokes was significantly less with the overdenture for all foods except carrot. Cycle duration was significantly longer with the overdenture for sausage and carrot. Contrary to what might be expected, the long-bar overdenture appears to be no less efficient than the fixed prosthesis. Furthermore, these data suggest that patients are capable of adapting their masticatory movements to the characteristics of the two prostheses.

Adult↗