Compensation procedures for facial asymmetries.

Why would a patient complain of "fuzzy and uncomfortable" vision with a variety of glasses? Perhaps because the practitioner has failed to take facial asymmetry into account. Methods of measuring facial asymmetry and optically correcting for it are discussed.

Eyeglasses↗

An indication for "granny glasses".

A young woman with a large astigmatic refractive error obtained no visual improvement with glasses. Repeated manifest refractions revealed persistent variations in the apparent cylinder axis. A suitable choice of spectacle frames facilitated a satisfactory outcome. The pitfalls inherent in the clinical specification of cylinder axis, and the potential visual consequences, are discussed.

Adolescent↗

The performance of the refractive status and vision profile survey in a contact lens clinical trial.

OBJECTIVE: To evaluate the Refractive Status and Vision Profile (RSVP) questionnaire in a contact lens clinical trial and to assess the feasibility of its use in future trials. DESIGN: Randomized, crossover clinical trial and survey. PARTICIPANTS: The RSVP was administered to 50 contact lens-wearing participants recruited from a large contact lens clinic. METHODS: RSVP scores were calculated for subjects at three outcome visits: (1) baseline, (2) after wearing daily disposable contact lenses, and (3) after wearing disposable extended wear contact lenses. One-sample t tests were used to compare baseline survey scores with those previously reported for the instrument. The relation of survey scores within and between subjects was assessed with repeated measures analysis of variance. Statistical power and sample size calculations were performed to determine the number of subjects required in future studies to detect differences in RSVP subscale scores. MAIN OUTCOME MEASURES: Eight subscale scores (concern, driving, expectations, glare, optical problems, physical and social functioning, problems with corrective lenses, and symptoms) and the overall RSVP score were calculated on the basis of guidelines reported for scoring of the instrument. RESULTS: Five of eight mean subscale scores (concern, expectations, driving, optical problems, and problems with corrective lenses) and the overall score were significantly lower than those previously reported. No differences were found in the following subscales after contact lens treatment: concern, expectations, physical and social functioning, driving, optical problems, problems with corrective lenses, or the overall RSVP score. Significant differences were found on the symptoms (P = 0.03) and glare (P = 0.05) subscales; post hoc testing revealed that the significant differences in these scores occurred between baseline and daily disposable lens wear and not between treatment modalities (daily disposable and disposable extended wear). A sample size of 420 would be required to find clinically relevant significant differences (25%) for all subscales in a similar one-sample clinical trial. A more restrictive difference (10%) would require more than 1100 subjects for four of the nine subscales. CONCLUSIONS: The RSVP questionnaire may not be the appropriate quality-of-life instrument for use in a contact lens clinical trial. The instrument seems to lack sensitivity and discriminative validity in evaluating contact lens treatments.

Adolescent↗

Intraocular lens implantation in the absence of capsular support: a report by the American Academy of Ophthalmology.

OBJECTIVE: This review was conducted to determine the safety and efficacy of open-loop anterior chamber, scleral-sutured posterior chamber, and iris-sutured posterior chamber intraocular lenses (IOLs) in eyes with inadequate capsular support for posterior chamber implantation in the capsular bag or ciliary sulcus. It also attempted to determine whether there is a preferred IOL or fixation site of choice in eyes with inadequate capsular support. METHODS: A literature search conducted for the years 1980 to 2001 yielded 189 citations related to IOL implantation in the absence of capsular support. An update search, conducted in March 2002, yielded an additional 28 articles. The Anterior Segment Panel members reviewed these abstracts and selected 148 articles of possible clinical relevance for review. Of these, 89 were considered sufficiently clinically relevant for the panel methodologist to review and rate according to the strength of evidence. A level I rating was assigned to properly conducted, well-designed, randomized clinical trials; a level II rating was assigned to well-designed cohort and case-control studies; and a level III rating was assigned to case series. Articles comparing the safety and efficacy of the IOL type and fixation site were further evaluated for the quality of the statistical methods used in the study. Studies with a rating of A or B were considered acceptable, C was borderline, and D and F were considered unacceptable as medical evidence. RESULTS: Forty-three articles with data concerning outcome of IOL insertion in eyes with inadequate capsular support had an evidence rating of level III or higher and were used in the final review of the safety and efficacy of one or more lens types and/or fixation sites. Seven articles had data about more than one lens type. Six had a statistical method rating of C or higher and were used to evaluate differences in visual outcomes and complication rates between lens types and fixation sites. CONCLUSIONS: The literature supports the safe and effective use of open-loop anterior chamber, scleral-sutured posterior chamber, and iris-sutured posterior chamber IOLs for the correction of aphakia in eyes without adequate capsular support for placement of a posterior chamber lens in the capsular bag or ciliary sulcus. At this time, there is insufficient evidence to demonstrate the superiority of one lens type or fixation site. Precise determination of small differences in visual outcome or complication rates will require a large prospective, randomized clinical trial.

Anterior Chamber↗

Comparison of adverse events with daily disposable hydrogels and spectacle wear: results from a 12-month prospective clinical trial.

OBJECTIVE: To evaluate the type and incidence of adverse events seen with daily disposable hydrogel contact lens wear compared with a control (spectacle) group over 12 months. DESIGN: Prospective, randomized, observer-masked, comparative clinical trial. PARTICIPANTS: Two hundred eighty-one myopes with no prior contact lens wear experience were enrolled from August to December 1996. Subjects were 16 to 35 years old and had refractive errors ranging from a -0.75-diopter (D) sphere to a -6.00-D sphere with a cylinder less than -1.00 D. INTERVENTION: Each subject was randomly assigned to wear either bilateral disposable hydrogels on a daily disposable wear schedule or spectacles. MAIN OUTCOME MEASURE: Type and incidence of adverse events from each group. Adverse events were categorized as serious, significant, and nonsignificant based on the potential to cause vision impairment, severity at event, and level of clinical concern. RESULTS: At baseline, 1.6% of eyes had asymptomatic infiltrates that were nonsignificant. During the study, asymptomatic infiltrates were seen in both contact lens and spectacle groups at 20.5 events versus 11.3 events per 100 eyes per year of wear. No significant events were seen with the spectacle group. With the contact lens group, the type and incidence of significant events per 100 eyes per year of lens wear were corneal peripheral ulcer, 2.5 events; infiltrative keratitis, 1.5 events; and papillary conjunctivitis, 1 event. The incidence of both significant and nonsignificant events was greater with the contact lens group (P<0.05). No serious events (i.e., microbial keratitis) were seen in either group. A greater number of subjects were lost to follow-up or permanently discontinued from the contact lens group relative to the spectacle group (33% vs. 17%, P = 0.002). Lens-related problems such as dryness, discomfort, and difficulty with insertion and removal accounted for 27% of discontinuations from the contact lens group. Poor compliance (40%) was the greatest reason for discontinuations from the spectacle group. CONCLUSIONS: No clinically serious events were seen with either group. Only a small percentage of contact lens-wearing eyes presented with significant events, which is promising for daily disposable lens wear. Far more contact lens subjects were lost to follow-up or discontinued. Small, asymptomatic, subepithelial corneal infiltrates of unknown significance were seen in both contact lens- and spectacle-wearing eyes.

Adolescent↗

Coralline hydroxyapatite spheres as secondary orbital implants in anophthalmos.

BACKGROUND: Secondary reconstruction of the anophthalmic socket is frequently challenging. A number of surgical techniques are described to improve the cosmetic and functional outcome. Recently, the use of hydroxyapatite as a primary orbital implant after enucleation has gained popularity and yielded encouraging surgical results. There are no published reports concerning the use of hydroxyapatite as a secondary orbital implant in anophthalmos. METHODS: The authors reviewed the charts of 17 patients who received a secondary hydroxyapatite orbital implant to rehabilitate the anophthalmic socket. Each patients' preoperative and postoperative photographs, socket appearance, implant and prosthetic motility, and overall impressions of the surgical outcome were analyzed. Complications of surgery and secondary procedures were reviewed. RESULTS: All except one patient attained an improved prosthetic appearance postoperatively and 76% achieved improved implant and prosthetic motility. Four patients undergoing surgery early in the series had worsening of pre-existing ptosis. In two patients, implant exposure developed; a socket infection with subsequent loss of the implant developed in one of these patients. Eight patients underwent additional eyelid and orbital surgery at the time of secondary implant surgery, whereas nine patients required additional staged procedures. CONCLUSION: Secondary orbital implantation with the coralline hydroxyapatite sphere is an encouraging alternative to traditional secondary orbital implant surgery. Surgical outcomes in this study were excellent with few complications and high patient satisfaction.

Adolescent↗

Fixation elements on plate intraocular lens: large positioning holes to improve security of capsular fixation.

OBJECTIVE: This study aimed to evaluate in rabbit eyes the effects of large positioning holes in one-piece silicone plate-haptic intraocular lenses (IOLs) with respect to security of capsular bag fixation. Mechanical strength of capsular fixation is correlated with the histologic findings of regenerating lens material and fibrous tissue ingrowth through the positioning holes on silicone plate IOLs, comparing capsules implanted with large-hole style plate IOLs to fellow capsules implanted with small-hole style plate IOLs. DESIGN: The study design was a prospective, randomized, experimental study. PARTICIPANTS: A total of 40 fellow capsular bags from 20 New Zealand white rabbits were examined. Capsules implanted with conventional small-hole silicone plate IOLs were used as the control in all pairs of fellow capsules. INTERVENTION: Phacoemulsification and implantation of a silicone plate IOL with small positioning holes in one eye and implantation of a silicone plate IOL with large positioning holes in the fellow eye were measured. All rabbits were killed at 2 months. The force required to extract the IOLs from the capsular bag was measured. All capsular bags underwent histopathologic analysis. MAIN OUTCOME MEASURES: Extraction force measurements and histopathologic examination, comparing capsules implanted with small-hole plate IOLs with fellow capsules implanted with large-hole plate IOLs, were measured. RESULTS: The large-hole style IOL required significantly more force to extract from the capsular bag compared to the conventional small-hole style (P = 0.003). Histologically, proliferating lens epithelial material and fibrous tissue were observed growing through all of the large positioning holes (synechia formation) but not through any of the small positioning holes. CONCLUSIONS: Silicone plate IOLs with large positioning holes become affixed more firmly within the capsular bag compared to conventional small-hole plate IOLs. These findings suggest that large holes in silicone plate IOLs allow for superior capsular bag fixation. This should reduce the rates of decentration and dislocation.

Animals↗

A spring network model for the analysis of load transfer and tissue reactions in intra-medullary fixation.

OBJECTIVE: A spring network can be used to represent the load transfer from a prosthetic stem into its surrounding bone. The study seeks to test the hypothesis that clinical patterns of bone remodelling can be simulated using a feedback that modifies the properties of the network depending on the load transfer. DESIGN: A mathematical model is used to simulate the initial properties of the linear system and its subsequent remodelling behaviour. BACKGROUND: A stable and pain-free transfer of physiological forces is essential for a clinically successful arthroplasty. Following surgery, bone remodelling and osteolysis can modify this load transfer. METHODS: The combined effect of all factors that influence prosthesis-bone load transfer are summarised in the properties of 'inter-link' springs that connect springs representing the prosthesis and bone in the linear network. It is on these inter-links that a remodelling feedback operates, and their properties can be varied with time in response to deformation or force values. RESULTS: Reducing inter-link stiffness leads to a broad distribution of load transfer, whilst an iso-elastic stem concentrates this transfer through the proximal and distal portions of a prosthesis. Physiological patterns of bone resorption and osteolysis become apparent in a time-series analysis of the feedback in the linear system. Specifically, osseo-integration requires a fixation of sufficient stiffness otherwise loosening will occur. Simulated osteolysis following osseo-integration loosens the implant from a distal to a proximal direction. CONCLUSIONS: Complex physiological bone remodelling patterns can emerge from a simple feedback within a linear system. Relevance. Implant loosening is presented here as an adverse response of a stable dynamic system caused by mechanical or biological stimuli.

Arthroplasty, Replacement, Hip↗

Energy storage and return prostheses: does patient perception correlate with biomechanical analysis?

The development and prescription of energy storage and return prosthetic feet in favor of conventional feet is largely based upon prosthetist and amputee experience. Regretfully, the comparative biomechanical analysis of energy storage and return and conventional prosthetic feet is rarely a motivation to either the technical development or clinical prescription of such devices. The development and prescription of prosthetic feet without supportive scientific evidence is likely due to the conflicting or non-significant results often presented in the scientific literature. Despite the sizeable history of comparative prosthetic literature and continued analysis of prosthetic components, the link between clinical experience and scientific evidence remains largely unexplored.A review of the comparative analysis literature evaluating energy storage and return and conventional prosthetic feet is presented to illustrate consistencies between the perceptive assessments and the objective biomechanical data. Results suggest that while experimental methodologies may limit the statistical significance of objective gait analysis results, consistent trends in temporal, kinetic, and kinematic parameters correlate well with perceptive impressions of these feet. These correlations provide insight to subtle changes in gait parameters that are deemed neither clinically nor statistically significant, yet are perceived by amputees to affect their preference for and performance of prosthetic feet during locomotion. Acknowledging and targeting areas of perceptive significance will help researchers develop more structured protocols for energy storage and return prosthesis evaluation as well as provide clinicians with information needed to enhance the appropriateness of their clinical recommendations. Expanding test environments to measure activities of perceived improvement such as high-velocity motions, stair ascent/descent, and uneven ground locomotion will provide a more appropriate assessment of the conditions for which energy storage and return prosthetic feet were designed. Concentrating research to specific test populations by age or amputation etiologies can overcome statistical limitations imposed by small study samples. Finally, directing research toward the areas of gait adaptation, heel performance, and the temporal release of energy in energy storage and return feet may reinforce the selection and utilization of advanced prosthetic components. These enhancements to current biomechanical analyses may serve to reduce the boundaries of perceptive significance and provide clinicians, designers, and researchers with the supportive data needed to prescribe, design, and evaluate energy storage and return prosthetic feet.

Amputees↗

A new approach of designing the tibial baseplate of total knee prostheses.

OBJECTIVE: To improve the design of the knee prosthesis, a new technique to design the tibial baseplate of total knee prostheses was developed. METHODS: One senior surgeon operated on 79 osteoarthrosis patients by using PCA total knee prostheses for total knee replacement. Four dimensions were measured intraoperatively and compared, including the anterioposterior length and the mediolateral width of the resected tibia plateau and implant. The data of anterioposterior length and the mediolateral width of resected surfaces of the tibial plateau of the 79 patients were plotted in a coordinate system. This coordinate system was formed with the mediolateral width as the x-axis and anterioposterior length as the y-axis. A circle, 5 mm in diameter, was used as the maximum coverage criterion. Five contemporary products and a new design product were used to screen the data to see how many patients would fall within the criteria. From the results of the screened data, we calculated the coverage percentage of the patients. RESULTS: The ratio of the anterioposterior length to the mediolateral width of the resected surfaces of the tibial plateau was greater than that of the ratio of the PCA prostheses (P < 0.05). The results showed that no single product on the market had the patients meet over 70% of the criterion. A different ratio of the anterioposterior length to the mediolateral width was designed to achieve 90% coverage of the patients that met the criterion. DISCUSSION: One possible explanation for the discrepancy between resected surfaces and implants is that the osteoarthrosis patients developed knee deformities that changed the surface of the tibial plateau and thus altered the knee dimensions. Since the total knee prostheses were used on osteoarthrosis patients, the dimensions of the resected tibial surfaces of osteoarthrosis patients should be considered in the design of the tibial baseplate of total knee prostheses.

Aged↗

Determination of the optimal elbow axis for evaluation of placement of prostheses.

OBJECTIVE: To present a method to determine the position and orientation of the mean optimal flexion axis of the elbow in vivo to be used in clinical research. DESIGN: Registering the movements of the forearm with respect to the upper arm during five cycles of flexion and extension of the elbow using a 6 degrees-of-freedom electromagnetic tracking device. BACKGROUND: Loosening of elbow endoprostheses could be caused by not placing the prostheses in a biomechanically optimal way. To evaluate the placement of endoprostheses with regard to loosening, a method to determine the elbow axis is needed. METHODS: The movements of the right forearm with respect to the upper arm during flexion and extension were registered with a 6 degrees-of-freedom electromagnetic tracking device. A mean optimal instantaneous helical axis of 10 elbows was calculated in a coordinate system related to the humerus. RESULTS: The average position of the flexion/extension axis was 0.81 cm (SD 0.66 cm) cranially and 1.86 cm (SD 0.72 cm) ventrally of the epicondylus lateralis. The average angle with the frontal plane was 15.3 degrees (SD 2 degrees). CONCLUSIONS: A useful estimation of the position and orientation of a mean optimal flexion axis can be obtained in vivo.

Adult↗

A new concept for a metacarpophalangeal prosthesis: consequence on joint biomechanics.

OBJECTIVE: The purpose of this work was to establish whether surface replacement non-constrained prostheses can duplicate the normal biomechanics of the metacarpophalangeal joint. DESIGN: A series of mathematical models. BACKGROUND: A non-constrained prostheses has been designed for the replacement of the metacarpophalangeal joint. It uses the concept of surface replacement in that it attempts to replicate the anatomy of the original cartilage surfaces. The centre of rotation of the prosthesis is also sited at the same position as in the natural joint to maintain the balance between the flexor and extensor tendon forces, such that the prosthesis duplicates the biomechanics of the normal joint. Due to the unique dimensions of each joint that may present for surgery, the four sizes of prosthesis that are available for implantation may not always produce an exact replication of the joint kinematics. These situations were examined to establish whether the biomechanics of the joint can indeed be restored. METHODS: Mathematical models for each size of prosthesis implanted into a range of different sized metacarpophalangeal joints were developed. The prosthetic and cartilage surface profiles were compared and the balance between the tendon forces was examined. RESULTS: Differences in size that may occur between the surface profiles of the normal joint and prosthesis, together with any relocation of the centre of rotation, would have negligible effects on the normal joint biomechanics. CONCLUSIONS: All four sizes of the non-constrained prosthesis can duplicate the normal biomechanics of the joint and hence provide normal function.

Biomechanical Phenomena↗

A comparison of microscrew and suture fixation for porous high-density polyethylene orbital floor implants.

Twenty oral and maxillofacial surgeons compared the surgical features of microscrew fixation technique with a suture technique for fixation of porous high-density polyethylene orbital floor implants. One investigator then compared material features of these two fixation techniques using recently procured bovine ribs. The microscrew technique was found to be quicker (P > .01) and easier (P > .001), and it provided a higher quality of fixation (P > .001) than the suture technique. The microscrew/implant system had a greater pullout strength (P > .001) and shear strength (P > .001) than the suture/implant system.

Animals↗

[Secondary reconstruction of stumps above the elbow. Five cases].

The authors report a serie of five patients with five stumps above the elbow who needed a secondary reconstruction to allow or facilitate a prosthesis. They used in the first case an expansion of the latissimus dorsi flap and of the axillary and prepectoral region in order to free the stump of the humerus sutured on the thorax. In the second case, a free parascapular flap covered an unstable scar of the clavicula after a scapulothoracic amputation. In the third case, the transfer of a free flap of fibula associated with a pedicled latissimus dorsi flap had allowed the elongation of the stump of the humerus. In the two last cases, a latissimus dorsi flap pedicled in one and free in the second one had allowed to preserved the length of the humerus for prosthesis. The technical choices are eclectic and different in every case. The purpose is to obtain an efficient trophicity and a thickness that can support the prosthesis and if possible a stump long enough to improve the adaptation of the prosthesis. The five operated patients were able to be apparated, reducing in this way their daily functional difficulties.

Activities of Daily Living↗

Muscle transposition and skin grafting for salvage of below-knee amputation level after bilateral lower extremity thermal injury.

Thermal injury to the lower extremity sometimes necessitates amputation around the knee joint. Knee function is so critical to prosthetic rehabilitation that every attempt should be made to salvage the knee joint. This report presents an unusual case of bilateral lower extremity flame burn requiring amputations. While the distal two-thirds of the legs and both feet were totally necrotic, the thermal damage was limited to skin and subcutaneous tissue sparing muscle and bone in the proximal one-third of the legs and posterior thighs. The below-knee amputation level was salvaged by muscle transposition over the anterior tibia and resurfacing of muscle cuffs with thick split-thickness skin grafts. The post-operative period was uneventful. Amputation stumps tolerated the below-knee prosthesis well and the patient attained independent functional prosthetic ambulation at the post-operative fourth month. It is known from the reconstruction of the plantar foot that skin-grafted muscle tissue tolerates weight bearing and shearing forces well. This principle can also be used for salvage aspects of the below-knee amputation level.

Adult↗

Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention.

Prosthesis-patient mismatch is present when the effective orifice area of the inserted prosthetic valve is less than that of a normal human valve. This is a frequent problem in patients undergoing aortic valve replacement, and its main hemodynamic consequence is the generation of high transvalvular gradients through normally functioning prosthetic valves. The purposes of this report are to present an update on the concept of aortic prosthesis-patient mismatch and to review the present knowledge with regard to its impact on hemodynamic status, functional capacity, morbidity and mortality. Also, we propose a simple approach for the prevention and clinical management of this phenomenon because it can be largely avoided if certain simple factors are taken into consideration before the operation.

Aortic Valve Stenosis↗

Outcome of total hip arthroplasty in small-proportioned patients.

In a prospective, consecutive series, 41 total hip arthroplasties were performed in 27 small-proportioned patients with small femoral dimensions. The 17 female and 10 male patients averaged 23.6 years (range, 14-47 years), and the mean height and weight were 157 cm (range, 132-183 cm) and 53.5 kg (range, 36-84 kg). The most common preoperative diagnosis was juvenile rheumatoid arthritis in 18 patients (28 hips). Most patients were severely disabled in their daily activity, and 68% of the patients were classified as Charnley functional class C. The femoral implants consisted primarily of the proximally porous-coated miniature Anatomic Medullary Locking femoral component (AML/CDH, Depuy, Warsaw, IN) in 33 hips in 22 patients (average stem diameter, 9.5 mm; range, 8-12.0 mm). A porous ingrowth acetabular cup fixed with screws was used in all procedures. At an average follow-up of 51 months, Harris Hip Scores improved significantly from 34 points (range, 0-65 points) preoperatively to 85 points (range, 33-100 points) after arthroplasty. There were no intraoperative complications. There was 1 revision because of femoral implant loosening. Three cementless femoral components showed evidence of nonprogressive subsidence. One patient had significant bilateral acetabular component polyethylene wear and underwent revision. All other femoral and acetabular components were radiographically stable. The relief of pain and improvement of function were dramatic. The miniature AML/CDH femoral component, combined with an uncemented acetabular cup, provides a promising, off-the-shelf alternative in small-proportioned patients.

Adult↗