Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Porosity”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59Linked to original sources

Extracellular fluid filtration as the reason for the viscoelastic behaviour of the passive myocardium.

The experimental results are described confirming the hypothesis that the viscous properties of the passive cardiac muscle are connected with the extracellular fluid filtration in the elastic medium formed by the connective tissue network and myocytes. It is shown that the relaxation properties are more pronounced in cold-blooded animals myocardium (frog, turtle) than in that of warm-blooded (cat, rabbit), which correlates with the smaller connective tissue content and larger porosity of myocardium in cold-blooded animals. The decrease in porosity of the cardiac muscle samples by reducing the osmosis of the surrounding solution or squeezing the fluid out of the samples by mechanical torsion results in the slowing down of the stress relaxation, the increase in porosity of the muscle in the hyperosmotic solution results in its speeding up. The increase of the surrounding solution viscosity by adding saccharose to it leads to the proportional stress relaxation deceleration, which agrees quantitatively and qualitatively with the advanced hypothesis.

Animals↗

Implantation of porous polymethylmethacrylate resin for tooth and bone replacement.

This study suggests that: 1. The porous plastic material tested is compatible with and showed no undesirable reactions in subcutaneous, intracerebral, intramuscular, and especially, intraosseous sites. 2. By standardizing porosity (e.g., a desired hole, any dimension, uniformly distributed) with the implant material (P.P.M.M.), one can predict with a degree of certainty that connective-tissue (collagen fibers) or hard-tissue (osteogenesis and reparative bone) ingrowth into these micropores will definitely occur. 3. The various shapes employed for implantation of the plastic material were not carcinogenic and did not cause a malignant reaction in any implanted region. 4. A close "amalgamation" with adjacent tissues was a result regardless of the implant site (e.g., intramuscular, intracerebral, or subcutaneous). Intraosseously, there was a variation. Depending upon the pore size, one observes either connective tissue or osseous ingrowth into the micropores. At a 100 micron pore size (B material), connective tissue ingrowth into the P.P.M.M. was seen. At the 450 micron size (E material), osseous tissue ingrowth into the P.P.M.M. was clearly observed. 5. The P.P.M.M. implant material can be used as a tooth replacement (e.g., for a root) at a small pore size (100 micron) and as a bone replacement (e.g., for bony defects) at a larger pore size (450 micron). 6. To secure vascularization of the implant material, porosity throughout is indicated at a large pore size. Surface porosity regardless of size will encourage only soft-tissue ingrowth into the implant material. 7. Any hard-tissue size or shape can be duplicated with the material, at any pore size, with compatibility to the adjacent tissue, regardless of the region of placement in the body. 8. There is a possibility of bone "induction" or stimulation of bone growth in predetermined directions with all its implications (e.g., periodontal disease). The replacement and repair of any hard tissue in the body (e.g., bone and teeth) are possibilities.

Animals↗

A comparative study of the strength of aluminous porcelain jacket crowns constructed with the conventional and twin foil technique.

The purpose of this study was to evaluate and compare the strength of aluminous porcelain jacket crowns made in the following manners: (1) the conventional technique, (2) the conventional technique with a pure alumina insert, (3) the twin foil technique, and (4) the twin foil technique with a pure alumina insert. The conclusions of this investigation can be summarized as follows: 1. Porosity was observed in all the restorations made by each of the techniques. 2. The porosity was greater at the porcelain-platinum foil interface than anywhere else throughout the restoration with both the conventional and twin foil techniques. 3. The porosity seemed to be evenly distributed along the interface, with no concentration in any area. 4. Regardless of the technique, crowns that were more porous fractured at lower values. 5. Crowns built by the twin foil technique were significantly more porous at the interface of the tin-plated platinum and the porcelain core than those built by the conventional technique. 6. Crowns constructed with the conventional technique were significantly stronger than those constructed with the twin foil technique. 7. There was no bond between the core porcelain and the platinum foil matrix in crowns constructed by the conventional technique. 8. There seemed to be a strong bond between the core porcelain and the tin-plated platinum matrix in crowns built by the twin foil technique. 9. The presence or absence of the alumina insert on crowns constructed with the conventional and twin foil technique did not affect the strength of the crowns when tested at the incisal edge.

Aluminum↗

Changes in eggshell water vapour conductance during shell formation in the chicken.

Time-related changes in shell porosity and eggshell water vapour conductance were measured in uterine eggs of the domestic fowl (Gallus domesticus) from 10 h in uterus to oviposition. Measurements were carried out in artificially-aborted eggs. It was found that the eggshell water vapour conductance decreased to a minimum level at 15 h in uterus. This coincided with increases in shell thickness and shell porosity as power functions of uterine time. From that time on, water vapour conductance increased as a power function of uterine time to the final value prior to oviposition. Thus, eggshell water vapour conductance is determined by different rates of dynamic changes in shell porosity and shell thickness in the course of shell calcification. The final conductance is reached about 2 h before oviposition.

Animals↗

Rapid curing of acrylic denture-base materials.

A rapid-cure polymerization of cure, including a terminal boil, with respect to transparency, residual monomer, mechanical properties, and generation of gaseous porosity. It was found that in order for porosity-free resin to be produced during rapid curing, a low concentration (approximately 0.26%) of benzoyl peroxide initiator in the powder component is vital, and a very small concentration (approximately 0.025%) of the chemical activator dimethyl-p-toluidine in the monomer component is an advantage. Mechanical properties were only influenced where substantial porosity existed, but it was recognized that a material "tailor-made" for rapid curing would be most welcome.

Acrylic Resins↗

Polymers for biodegradable medical devices. VII. Hydroxybutyrate-hydroxyvalerate copolymers: degradation of copolymers and their blends with polysaccharides under in vitro physiological conditions.

The hydrolytic degradation of hydroxybutyrate-hydroxyvalerate copolymers was monitored in vitro at 37 degrees C and pH 7.4. Direct use of bulk properties such as weight loss and tensile strength did not reveal substantial changes in the polymer matrix over degradation periods of several months. Despite this, the polymers were demonstrated to undergo significant modification during this period, in ways that markedly influence their subsequent behaviour. Combined use of goniophotometry and surface energy measurements revealed that surface modification begins at an early stage and is accompanied by diffusion of water into the matrix and a progressive increase in polymer porosity. Relatively little change in the molecular weight and some increase in the crystallinity of the matrix occurred during these early months. As a result, the tensile strength of the polymer varies little in this period. As the porosity of the matrix increases, hydrolytic chain scission within the matrix and diffusion out of degradation products proceeds more effectively. Decrease in matrix molecular weight, increase in matrix erosion, weight loss and loss of tensile strength began at a much more dramatic rate. The apparent resistance of the polymer to degradation in the early months is followed by an accelerated degradation phase around and beyond 1 yr. The use of filters that can dissolve or hydrolytically degrade more rapidly than the hydroxybutyrate matrix accelerates the development of porosity within the matrix and thus enhances the decomposition process.

Biocompatible Materials↗

Effects of In and Zn on properties of low noble metal alloys.

Four low noble metal alloys with high In and Zn contents were investigated with regard to porosity in castings, structure, tarnish, hardening mechanism and cytotoxicity. Fumes were observed above the melt, due to the high Zn content and low boiling point of this metal. This Zn evaporation during melting created a small amount of porosity in the castings. This porosity diminished when the Zn content was reduced from 4 to 2%. Scanning electronmicroscopy, microprobe analyses and X-ray diffraction analyses revealed a face-centred cubic (fcc) matrix enriched in Au and Ag and a body-centred cubic (bcc) phase enriched in Pd, In and Zn which had a yellow gold-like appearance. After immersion in a 2% Na2S solution for 72 h, no tarnish attack was observed on the PdlnZn-rich phase. The matrix phase was found to be slightly tarnished. The alloys remained yellow by visual inspection. The agar overlay technique displayed a very slight cytotoxic effect of a sandblasted specimen and no cytotoxic effect of a polished specimen.

Alloys↗

Optimum support properties for protein separations by high-performance size exclusion chromatography.

Optimum chromatographic properties of high performance size exclusion chromatography (HPSEC) of proteins, such as resolution, molecular weight accuracy and recovery, are obtained on packings and columns with tailor-made physical and chemical structures, employed at properly adjusted eluent compositions and operation conditions. SEC-theory suggests that a broad molecular weight fractionation range and high linearity of the log-linear calibration plot can be achieved by the use of two packings (10- and 80-nm pore size, characterized by a pore-size distribution (psd) equal to or less than 1 decade and by equal internal column porosity (p)), rather than a single 30- to 50-nm pore-size packing with a wide psd. Favourably high-phase ratios of (p)/(o)/ 1.0 for HPSEC columns were accomplished with a minimum interstitial column porosity (o) and a high value for the internal column porosity (p) (the specific pore volume, nu(p), multiplied by the packing density, varrho(p).) Ligands such as diol, N-acetoxyamino and oligomeric ether with a propyl- or propoxy-spacer bonded to the silica at the highest density appear to provide high mass recovery and bioactivity as well as chemical stability. Such packings, available in 3-5 mum particle size ranges of narrow distribution, packed into columns 6 mm i.d. and 500 mm in length, offer the best compromise with respect to resolution, speed and pressure drop. More careful studies are required to explain the effects of protein conformational changes and interconversions during elution on HPSEC columns.

Journal Article↗

Rabbit pilot study on the resorbability of three-dimensional bioactive glass fibre scaffolds.

Bioactive glass composed of Na2O-K2O-MgO-CaO-B2O3-P2O5-SiO2 is used in this study to manufacture three-dimensional glass fibre scaffolds for a synthetic bone filler material for the treatment of bone defects. The glass is characterized by a large working range, which is the temperature interval at which forming of glass can take place. A preliminary in vivo study on New Zealand skeletally mature rabbit's tibia is reported here. Bone defects were prepared in the medial surfaces of the diaphyses of the tibia. For the first time melt derived three-dimensional bioactive glass fibre constructs were used to fill the cavities. The different implants investigated here were a scaffold with a porosity of 45-50%, scaffold with a porosity of 55-60% and morsels with a porosity of 55-60%. The implanted bone substitutes were dissected after 6 months and evaluated by histological and synchrotron radiation micro tomography analysis. PerioGlas and empty defects were used as positive and negative controls, respectively. The result was that the surgically created tibial defects were healed and new bone formation was found in the medullary cavities. Despite the intrinsic limitations of a pilot study, the preliminary results indicate that in 6 months the glass fibre scaffolds are completely resorbed and that the osteoconductive properties of the filling material are strictly correlated with the structural and morphological characteristics of the bone substitute.

Animals↗

Neutron radiography of porous rocks and iron ore.

Neutron radiography can provide images of the internal structure of rocks, through virtue of the differing neutron attenuation characteristics of hydrogen versus other elements commonly found in nature. Thus, pores filled with water, or oil, will attenuate neutrons to a greater extent than the surrounding rock matrix. Similarly, the internal structure of iron ore, which contains mixtures of limonite and goethite, which contain hydrogen in their crystalline lattice, and magnetite (no hydrogen), can also be imaged using neutrons. The ability of the technique to distinguish "effective porosity" versus "total porosity" is derived from the neutron radiographs. Images of two iron ore samples have also been analyzed to demonstrate how both different mineral assemblages and porosity can be determined.

Journal Article↗

Mechanistic evaluation of the glucose-induced reduction in initial burst release of octreotide acetate from poly(D,L-lactide-co-glycolide) microspheres.

One major obstacle for development of injectable biodegradable microspheres for controlled peptide and protein delivery is the high initial burst of drug release occurring over the first day of incubation. We describe here the significant reduction in initial burst release of a highly water-soluble model peptide, octreotide acetate, from poly(D,L-lactide-co-glycolide) microspheres by the co-encapsulation of a small amount of glucose (e.g., 0.2%w/w), i.e., from 30+/-20% burst - glucose to 8+/-3% + glucose (mean+/-SD, n=4). This reduction is unexpected since hydrophilic additives are known to increase porosity of microspheres, causing an increase in permeability to mass transport and a higher burst. Using the double emulsion-solvent evaporation method of encapsulation, the effect of glucose on initial burst in an acetate buffer pH 4 was found to depend on polymer concentration, discontinuous phase/continuous phase ratio, and glucose content. Extensive characterization studies were performed on two microsphere batches, +/-0.2% glucose, to elucidate the mechanism of this effect. However, no significant difference was observed with respect to specific surface area, porosity, internal and external morphology and drug distribution. Continuous monitoring of the first 24-h release of octreotide acetate from these two batches disclosed that even though their starting release rates were close, the microspheres + glucose exhibited a much lower release rate between 0.2 and 24h compared to those - glucose. The microspheres + glucose showed a denser periphery and a reduced water uptake at the end of 24-h release, indicating decreased permeability. However, this effect at times was offset as glucose content was further increased to 1%, causing an increase in surface area and porosity. In summary, we conclude that the effect of glucose on initial burst are determined by two factors: (1) increased initial burst due to increased osmotic pressure during encapsulation and drug release, and (2) decreased initial burst due to decreased permeability of microspheres.

Coated Materials, Biocompatible↗

Characterization of CO3Ap-collagen sponges using X-ray high-resolution microtomography.

For reconstruction and regeneration of hard tissues, scaffold biomaterials with large size pores and high porosity are important, in addition to their roles as supporting frames. To develop a new biodegradable scaffold biomaterial, CO3Ap, which has crystallinity and a chemical composition similar to bone, was synthesized at pH 7.4 and 60 degrees C. Then, the CO3Ap was mixed with a neutralized collagen gel and the CO3Ap-collagen mixtures with different kinds of CO3Ap contents and porosity were lyophilized into sponges. Scanning electron micrography (SEM) observation of CO3Ap-collagen sponges showed favorable pores for cell invasion. Approximately 50-300 microm size pores appeared to continue through the bulk. Higher magnification of the sponge showed a better adhesion between CO3Ap crystals and collagen. X-ray high-resolution microtomography revealed a clear image of the 3D structure of the sponges. The porosity of 0, 70 and 90%(w/w) CO3Ap-collagen sponges was 79.2 +/- 2.8%, 72.6 +/- 2.4% and 48.9 +/- 6.1%, respectively. The 70%(w/w) CO3Ap-collagen sponge appeared to be the most favorable biomaterial from the viewpoint of natural bone properties. Mouse osteoblast MC3T3-E1 cells were cultured in alphaMEM with 10% FCS for 2 weeks. Hematoxylin-eosin staining confirmed osteoblast cells invaded well into the CO3Ap-collagen sponge. These sponges are expected to be used as hard tissue scaffold biomaterials for therapeutic uses.

3T3 Cells↗

Characterization of some physical and chromatographic properties of monolithic poly(styrene-co-divinylbenzene) columns.

Monolithic capillary columns were prepared by copolymerization of styrene and divinylbenzene inside a 200 microm i.d. fused silica capillary using a mixture of tetrahydrofuran and decanol as porogen. Important chromatographic features of the synthesized columns were characterized and critically compared to the properties of columns packed with micropellicular, octadecylated poly(styrene-co-divinylbenzene) (PS-DVB-C18) particles. The permeability of a 60 mm long monolithic column was slightly higher than that of an equally dimensioned column packed with PS-DVB-C18 beads and was invariant up to at least 250 bar column inlet pressure, indicating the high-pressure stability of the monolithic columns. Interestingly, monolithic columns showed a 3.6 times better separation efficiency for oligonucleotides than granular columns. To study differences of the molecular diffusion processes between granular and monolithic columns, Van Deemter plots were measured. Due to the favorable pore structure of monolithic columns all kind of diffusional band broadening was reduced two to five times. Using inverse size-exclusion chromatography a total porosity of 70% was determined, which consisted of internodule porosity (20%) and internal porosity (50%). The observed fast mass transfer and the resulting high separation efficiency suggested that the surface of the monolithic stationary phase is rather rough and does not feature real pores accessible to macromolecular analytes such as polypeptides or oligonucleotides. The maximum analytical loading capacity of monolithic columns for oligonucleotides was found to be in the region of 500 fmol, which compared well to the loading capacity of the granular columns. Batch-to-batch reproducibility proved to be better with granular stationary phases compared to monolithic stationary phase, in which each column bed is the result of a unique column preparation process.

Chromatography, High Pressure Liquid↗

Controlled release of saccharides from matrix tablets.

The aim of this study was to design site specific, controlled release tablets of N-acetyl-d-glucosamine (NAG), maltose monohydrate and maltopentaose by using hydrophobic matrix formers starch acetate (SA) and ethyl cellulose (EC). The optimized matrices, which had either low porosity and high drug load or high porosity and low drug load, released the saccharides within the desired 2-4 h. In general, it was possible to control the release rate of saccharides by altering the relative amount of hydrophobic matrix former in the tablet and tablet porosity. The release type of saccharides from these formulations varied from immediate release to sustained release. In the case of sustained release formulations, it was found that the release of maltose monohydrate and maltopentaose was biphasic and slower than the release rate of NAG from similar tablets. NAG release kinetics followed square root of time kinetics, while in the case of maltose monohydrate and maltopentaose, the release kinetics were zero order in both phases. The biphasic dissolution profile was proposed to be caused by water mediated recrystallisation of the disordered material formed during the dissolution. Both SA and EC matrices were found to represent suitable controlled oral delivery vehicles for saccharides.

Acetylglucosamine↗

Drug release from reservoir pellets compacted with some excipients of different physical properties.

The aim of the present study was to investigate the influence of the size and the porosity of excipient microcrystalline cellulose (MCC) particles on the densification and the deformation during compaction and the consequent effect on the drug release from reservoir pellets. Drug pellets consisting of salicylic acid and microcrystalline cellulose were prepared by extrusion-spheronisation and spray-coated with ethyl cellulose (ethanol solution). Excipient pellets of different size and porosity were prepared by extrusion-spheronisation or direct spheronisation. Five binary mixtures of reservoir pellets and excipient particles were prepared in the proportion 1:7 and lubricated. After compaction the reservoir pellets were retrieved and analysed to determine the intragranular porosity, surface area, shape and drug release. The reservoir pellets were shown to undergo extensive deformation and densification during compaction, resulting in a preserved or even prolonged drug release time. The mode of deformation of the reservoir pellets seems to be critical for the compression-induced change in drug release. Formation of large indents has a negative effect on the release time, while the use of small particles or small deformable agglomerates has a protective effect. We also hypothesize that the coating structure changes during compaction and the final structure of the coating is the net effect of two parallel processes, one reducing and one prolonging the drug transport time across the coating.

Cellulose↗

Characterization and drug-permeation profiles of microporous and dense cellulose acetate membranes: influence of plasticizer and pore forming agent.

The use of pore forming agents and plasticizers are efficient ways to obtain membranes for controlled drug permeation through polymeric membranes. The challenge of the present study was to combine these two strategies to obtain cellulose acetate (CA) membranes, where poly(caprolactone triol) (PCL-T) was used as a plasticizer and water, dissolved in a casting solution, was used as a pore forming agent. First, the influence of water on membrane morphology, porosity and the permeation coefficient of a model drug (paracetamol) was analyzed. The influence of different amounts of PCL-T on the permeation coefficient of the CA membranes was then evaluated. Finally, both strategies were combined to obtain porous CA/PCL-T membranes. The membrane microstructure was analyzed using scanning electron microscopy (SEM), the CA crystallinity was determined via differential scanning calorimetry (DSC), and membrane permeability was investigated using paracetamol. The addition of water, a non-solvent, during the membrane casting process was found to be a simple and effective way to change membrane porosity and consequently the drug-permeation profile. When small quantities of non-solvent were used to obtain low porosity membranes, the presence of a plasticizer agent could be used to better modulate drug permeation. Combining the addition of PCL-T with the use of a non-solvent resulted in a series of CA membranes with paracetamol-permeation coefficient values in the range of ca. 10(-7) to 10(-5) cm s(-1).

Cellulose↗

Comparison of acoustic characteristics predicted by Biot's theory and the modified Biot-Attenborough model in cancellous bone.

Biot's theory and the modified Biot-Attenborough (MBA) model are applied to predict the dependences of acoustic characteristics on frequency and on porosity in cancellous bone. The phase velocities and the attenuation coefficients predicted by both theories are compared with the experimental data of bovine cancellous bone specimens published in the literature. Biot's theory successfully predicts the dependences of the phase velocity on frequency and on porosity in cancellous bone, whereas a significant discrepancy is observed between the predicted and the measured attenuation coefficients. The MBA model agrees well with the frequency and the porosity dependences of the phase velocity and the attenuation coefficient experimentally measured in bovine bones. Although the MBA model relies on phenomenological parameters derived from the experimental data, its approach to cancellous bone can be usefully employed in the field of clinical ultrasonic bone assessment.

Acoustics↗

Prediction of the micro-fluid dynamic environment imposed to three-dimensional engineered cell systems in bioreactors.

Bioreactors allowing culture medium perfusion overcome diffusion limitations associated with static culturing and provide flow-mediated mechanical stimuli. The hydrodynamic stress imposed to cells will depend not only on the culture medium flow rate, but also on the scaffold three-dimensional (3D) micro-architecture. We developed a CFD model of the flow of culture medium through a 3D scaffold of homogeneous geometry, with the aim of predicting the shear stress acting on cells as a function of parameters that can be controlled during the scaffold fabrication process, such as the scaffold porosity and the pore size, and during the cell culture, such as the medium flow rate and the diameter of the perfused scaffold section. We built three groups of models corresponding to three pore sizes: 50, 100 and 150 microm. Each group was made of four models corresponding to 59%, 65%, 77%, and 89% porosity. A commercial finite-element code was used to set up and solve the problem and to analyze the results. The mode value of shear stress varied between 2 and 5 mPa, and was obtained for a circular scaffold of 15.5 mm diameter, perfused by a flow rate of 0.5 ml/min. The simulations showed that the pore size is a variable strongly influencing the predicted shear stress level, whereas the porosity is a variable strongly affecting the statistical distribution of the shear stresses, but not their magnitude. Our results provide a basis for the completion of more exhaustive quantitative studies to further assess the relationship between perfusion, at known micro-fluid dynamic conditions, and tissue growth in vitro.

Bioreactors↗