Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “PATENTS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59Linked to original sources

Precision and accuracy of clinical and radiological signs in premature infants at risk of patent ductus arteriosus.

OBJECTIVE: To determine the precision (interobserver agreement) and accuracy (agreement with criterion standard) of clinical and radiological signs in premature infants at risk of patent ductus arteriosus (PDA) with left-to-right shunting. DESIGN: Masked comparison of clinical and radiological examination with Doppler flow echocardiography (criterion standard). SETTING: Neonatal intensive care unit. PATIENTS: One hundred infants with birth weights less than 1750 g were studied once between days 3 and 7 of life. A third of the cohort was intubated at the time of study. INTERVENTION: Five independent observers noted the presence or absence of an increased pulse volume, an active precordium, a heart murmur, a cardiothoracic ratio greater than 60%, increased pulmonary vascular markings on a concurrent chest x-ray film, and a relative increase of the cardiothoracic ratio compared with that from the previous chest x-ray film. Pulsed and color flow Doppler echocardiography was performed within 4 hours. All 100 tapes were reviewed by a second pediatric cardiologist. RESULTS: Twenty-three infants had a PDA with left-to-right shunting. The precision of clinical signs was modest, with average kappa values of 0.15 for pulse volume, 0.32 for precordium, and 0.41 for murmur. Pulse quality (43%) and murmur (42%) had the highest mean sensitivities. Corresponding specificities were 74% for pulse volume and 87% for murmur. The combination of a cardiac murmur with an abnormal pulse volume had the highest positive predictive value (77%). The radiological examination did not improve the observers' ability to distinguish between patients with and without PDA. CONCLUSIONS: The precision and accuracy of clinical and radiological signs of a PDA with left-to-right shunting are unsatisfactory. Therefore, Doppler flow echocardiography is required to diagnose PDA confidently in preterm infants between days 3 and 7 of life.

Ductus Arteriosus, Patent↗

Additional aortopulmonary collaterals in patients referred for coil occlusion of a patent ductus arteriosus.

Coexisting aortopulmonary collaterals in patients diagnosed with a patent ductus arteriosus (PDA) are rare findings. Percutaneous transcatheter closure of PDA and requisite aortography offer an unique opportunity to identify and treat these systemic arterial anomailes, which would be missed by echocardiographic evaluation alone. The significance of these collaterals is unclear, but it may contribute to left heart dilation from additional left to right shunting in patients with an otherwise isolated small PDA. Of 18 patients undergoing transcatheter occlusion of a PDA with Gianturco coils, 2 were found to an additional significant aortopulmonary collaterals, which were also occluded.

Aortography↗

Interventional cardiac catheterization therapy for combined coarctation of the aorta and patent ductus arteriosus: successful outcome in two infants.

We report two infants each with coarctation of the aorta and small patent ductus arteriosus who had balloon angioplasty therapy for aortic obstruction at 3-6 months of age followed by anterograde placement of a single Gianturco coil to close the ductus at a separate catheterization. One infant developed recoarctation that resolved with repeat angioplasty prior to closure of the ductus. Follow-up evaluations have demonstrated a trivial aortic gradient, no aortic aneurysm, and no residual shunt.

Angioplasty, Balloon↗

Percutaneous closure of small patent ductus arteriosus: comparison of Rashkind double-umbrella device and occluding spring coils.

We compared our current practice of closing small patent ductus arteriosus (PDA) with coils with our previous experience of using double-umbrellas. Twelve patients underwent percutaneous closure of a small PDA with a coil. Selection criteria were a minimal diameter of < or = 2.5 mm and angiographic type A or E. The 12 most recent, non-consecutive patients who had undergone double-umbrella device closure of a PDA and would presently be considered suitable candidates for spring coil occlusion were retrospectively reviewed. The two groups were compared with regard to complications and immediate and midterm results. Eleven of the 12 attempted PDA occlusions using spring coils were successful. The mean follow-up period was 5.8 +/- 4.6 months. Color-Doppler echocardiograms have shown no residual leaks, no turbulence in the descending aorta, and no left pulmonary artery stenosis. All 12 attempted double-umbrella device placements were successful. The mean follow-up period was 16.2 +/- 5.8 months. Color-Doppler echocardiograms have shown trivial residual leaks in four patients and mild turbulent flow in the left pulmonary artery in one patient. There was no significant difference between the two groups in demographic and hemodynamic data. Although the mean follow-up time was significantly longer in the patients who underwent double-umbrella closure, there was significantly more color-Doppler echocardiographic evidence of residual flow (P < 0.03). Small PDA closure with coils is effective, resulting in less residual leaks compared with the double-umbrella device.

Child↗

New technique using temporary balloon occlusion for transcatheter closure of patent ductus arteriosus with Gianturco coils.

We describe our early experience with a new technique involving temporary balloon occlusion for transcatheter closure of patent ductus arteriosus (PDA) using single or multiple Gianturco coils. Coil occlusion was attempted in 21 patients of median age 3 (range 1-11) years, and angiographic PDA diameter 3.0 mm +/- 0.87 mm. The inflated balloon of a pulmonary wedge pressure catheter over a transductal wire was used to mechanically hold the first extruded loop of the coil at the pulmonary end of the duct. If a residual shunt persisted after the delivery of the first coil, additional coils were delivered with or without the balloon support. One to nine coils (median 2) of different sizes varying between 3-12 mm diameter and 4-15 cm length were used. Immediate angiographic occlusion rate was 47.6%. However color Doppler (CD) at 24 hours and at 6 weeks revealed complete closure in 66.6% and 80.9%, respectively. Blood transfusion was required in 2 (9.5%) patients. Three out of 56 coils (5.4%) embolized during deployment. The use of balloon occlusion is effective and safe in the treatment of ducti up to 4.7 mm. Residual shunts lend to occlude with time.

Aortography↗

Percutaneous closure of patent ductus arteriosus using special screwing detachable coils.

Jackson screwing detachable coils, developed for arterial and venous embolization, have been successfully employed recently for the percutaneous occlusion of patent ductus arteriosus (PDA). Special screwing detachable coils were designed for closure of the PDA, and the experience gained by their use is described in this report. Occlusion was attempted in 29 patients with a minimal ductal diameter of 0.9-4.2 mm. Coils were successfully placed in all 29 patients. One coil, which embolized 10 min after detachment, was retrieved. In 26 patients (89%), complete closure was achieved. Only 35 coils were placed in 29 patients. Residual shunts in three patients are minimal, detectable only on color-flow mapping. Screwing detachable coils for closure of PDA are safe and effective for occlusion of PDA with a minimal diameter < 4.2 mm. Embolization of the coil is very rare. A high closure rate is achieved with a low number of placed coils.

Adolescent↗

Coarctation of the aorta following coil occlusion of a patent ductus arteriosus.

A case is described in which coarctation of the aorta develops following coil occlusion of a patent ductus arteriosus with a single Gianturco coil. This finding has yet to be reported in children undergoing this procedure and demonstrates the possibility of its occurrence and brings into question the need for and the duration of antibiotic prophylaxis following coil deployment.

Aortic Coarctation↗

Transcatheter closure of patent ductus arteriosus in children weighing < 10 kg with Gianturco coils using the balloon occlusion technique.

We evaluated the immediate and intermediate follow-up results of transcatheter closure (TCC) of patent ductus arteriosus (PDA) using Gianturco coils in children weighing < 10 kg. The results of PDA < or = 2.5 mm (group I, n = 18) and > 2.5 mm (group II, n = 16) were compared. Coils were deployed sequentially by transarterial route using a temporary balloon occlusion technique. The immediate clinical success rate in both groups was comparable. There was no significant difference in the number of coils required per patient and in the embolization rate between the two groups. Both groups had comparable occlusion rates at intermediate-term follow-up. At intermediate follow-up, one patient had developed left pulmonary artery stenosis while obstruction of the descending aorta was not seen in any; in 4 children the PDA had recanalized. Spontaneous reocclusion was observed in 3 of the latter at the last follow-up. We conclude that TCC of PDA is feasible and safe in children weighing < 10 kg with gratifying intermediate-term results.

Aortography↗

Vessel-sparing technique for coil occlusion of the very small patent ductus arteriosus.

A technique is described for coil occlusion of the small patent ductus arteriosus through a 4 French arterial catheter. The need for a 5 French sheath and catheter to stabilize the 3 French size delivery catheter system is obviated. The method is proposed as a way to minimize arterial vascular injury in the small patient undergoing transcatheter occlusion of the small ductus.

Cardiac Catheterization↗

New approach to the diagnosis of patent ductus arteriosus during catheterization.

The diagnosis of patent ductus arteriosus (PDA) usually requires catheterization, as does percutaneous treatment of the disorder. To obtain pressure gradients, a catheter can be passed in either direction through the PDA, from the pulmonary artery to the aorta or via the more common route of aorta to pulmonary artery. Several types of catheters have been used, but to date there have been no reports showing the use of a left internal mammary artery (LIMA) angiographic catheter for this purpose. We report successful passage of this catheter from the aorta across a PDA to the pulmonary artery in 15 adult patients who were observed to have no complications.

Adult↗

Transcatheter occlusion of the patent ductus arteriosus: use of the retrievable coil device.

The Cook Retrievable Embolization Coil has been designed to improve delivery and positioning during coil embolization of the patent ductus arteriosus (PDA). We report our experience with the use of this new technique. Twenty-eight patients underwent coil embolization of a PDA using the retrievable system. The median patient age was 4.5 years (range, 2 months to 33 years), median weight 17.2 kg (range, 3.1-100 kg). The mean minimum diameter was 1.1 mm (range, 0.3-3.8 mm). One or two Cook Retrievable Embolization Coils were implanted in each PDA. Successful delivery was achieved in 27 cases. There was no shunt by angiography in 19 of the patients (70%). Color echocardiography documented no shunt in 13 of 17 patients (77%). The retrievable coil system represents a successful method of PDA occlusion with good control of coil positioning and delivery.

Adolescent↗

Radiation exposure to children during coil occlusion of the patent ductus arteriosus.

The risks of excessive exposure to ionizing radiation are well described and measures are routinely taken to limit such exposure to both patient and personnel in the catheterization laboratory. Coll occlusion of the patent ductus arteriosus (PDA) as well as other more complex pediatric interventions has raised concern regarding radiation exposure, particularly as minimally invasive surgical techniques are being developed which lack such exposure risk. In eight consecutive patients, aged 0.7-7 years (median, 2.3 years), coil occlusion of a PDA was performed and surface entrance radiation dose determined by thermoluminescent dosimetry (TD). Total cumulative doses (PA + lateral dose) were also calculated for each patient. Entrance and cumulative dose was likewise measured in 12 patients undergoing standard diagnostic catheterization (DC) and in 5 consecutive patients undergoing pulmonary balloon valvuloplasty (PBV). The groups were comparable in age, weight, and body surface area (BSA). Total cumulative dose in the PDA patients was 97 +/- 25 mGy (mean +/- SE). There was no significant difference between the three groups in entrance dose absorbed at each location or in total cumulative dose. The mean total fluoroscopy time in the PDA occlusion group was significantly less than that of the PBV group (10.1 +/- 1.81 min vs. 19.3 +/- 2.29 min, P < 0.05) but was comparable to the DC group (13.2 +/- 1.5 min, P = NS). When the subjects were analyzed collectively, no correlation between fluoroscopy time and measured entrance dose was observed. The strongest correlates of total cumulative dose were patient weight (r = 0.67, P < 0.001) and BSA (r = 0.62, P = 0.001). Patients undergoing coil occlusion of a PDA are not exposed to increased radiation entrance dose compared to those undergoing standard DC and PBV. Furthermore, surface entrance radiation dose as determined by TD varies according to patient size for a given fluoroscopy time.

Body Height↗

Long-term outcome of transcatheter coil closure of small to large patent ductus arteriosus.

Coil closure of patent ductus arteriosus (PDA) has become an accepted alternative to surgical closure in most pediatric cardiac centers. However, little is known about the mid-to long-term outcome of this procedure. Therefore, we evaluated the immediate, short-, and long-term outcome of transcatheter coil closure (TCC) of PDA using single or multiple Gianturco coils or the Gianturco-Grifka Vascular Occlusive Device (GGVOD). One hundred forty-nine patients underwent an attempt at TCC of their PDAs at a median age of 2.4 years (2 weeks to 55 years) and median weight of 13.5 kg (2.3-87 kg). There were 33 patients < 1 year of age. The median PDA minimal diameter was 2 mm (0.4-7 mm) with 26 patients whose PDA minimal diameter was > 4 mm. A 4 Fr catheter was used for coil deployment in 136 patients, a 3 Fr in 4, and an 8 Fr in 4 patients who received the GGVOD. A single coil was used in 77 patients and multiple coils (2-6) were used in 66 patients. One hundred forty-six patients had successful closure (142 had immediate complete closure and 4 had residual shunt), 3 patients failed the initial attempt (2 underwent surgical ligation and 1 had a successful second attempt a year later). Of the four patients with residual shunt, three underwent a second procedure with implantation of 1-3 coils resulting in complete closure in all and one patient had spontaneous resolution of the residual shunt. Complications were encountered in nine patients: six had coil migration with successful retrieval in four; two had left pulmonary artery stenosis (2.4 kg and 6.3 kg infants), and one patient had loss of femoral arterial pulse. The median fluoroscopy time was 16 min (2-152 min). One hundred forty-two patients had the procedure as an outpatient, five patients stayed greater than 24 hr, and two of these patients were in hospital for 1 month for noncardiac reasons. At a median follow-up interval of 3.0 years (1 month to 5.1 years), there were no episodes of delayed coil migration, delayed recanalization, thromboembolic episodes, or bacterial endocarditis. Lung perfusion scans performed at a median follow-up interval of 1.6 years in 31 patients who received multiple coils revealed 45% +/- 5% blood flow to the left lung. Long-term follow-up of coil closure of PDA indicates that the technique is safe and effective for most patients with PDA up to a diameter of 7 mm.

Adolescent↗

Subclinical aortic perforation with the infant double-button patent ductus arteriosus occluder.

Modification of the double-button (Sideris) patent ductus arteriosus (PDA) occluder has resulted in a single-strut aortic component rather than the conventional cross-strut design. We report the use of this infant PDA occluder for transcatheter closure in three patients with PDA measuring 2 mm, 3.7 mm, and 4 mm. Subclinical aortic perforation with a small aortic aneurysm developed in two patients 1 year after occluder implantation. The third patient had developed a small aortic aneurysm without perforation at 3-month follow-up. All three patients had a residual shunt and underwent successful PDA surgical closure with aortic aneurysmal repair. Single-strut umbrella designs are not recommended for PDA transcatheter closure.

Aorta, Thoracic↗