Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Optical imaging”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59Linked to original sources

Reconstruction of Current Flow and Imaging of Current-Limiting Defects in Polycrystalline Superconducting Films

Magneto-optical imaging was used to visualize the inhomogeneous penetration of magnetic flux into polycrystalline TlBa2Ca2Cu3Ox films with high critical current densities, to reconstruct the local two-dimensional supercurrent flow patterns and to correlate inhomogeneities in this flow with the local crystallographic misorientation. The films have almost perfect c-axis alignment and considerable local a- and b-axis texture because the grains tend to form colonies with only slightly misaligned a and b axes. Current flows freely over these low-angle grain boundaries but is strongly reduced at intermittent colony boundaries of high misorientation. The local (<10-micrometer scale) critical current density Jc varies widely, being up to 10 times as great as the transport Jc (scale of approximately 1 millimeter), which itself varies by a factor of about 5 in different sections of the film. The combined experiments show that the magnitude of the transport Jc is largely determined by a few high-angle boundaries.

Journal Article↗

Molecular imaging and gene therapy.

Molecular imaging is an emerging field of study that deals with imaging of disease on a cellular or genetic level rather than on a gross level. Recent advances in this field show promise, particularly in the imaging of gene expression. This article reviews the use of nuclear medicine, magnetic resonance, and optic imaging to visualize gene expression. A review is presented of current in vitro assays for protein and gene expression and the translation of these methods into the radiologic sciences. The merging fields of molecular biology, molecular medicine, and imaging modalities may provide the means to screen active drugs in vivo, image molecular processes, and diagnose disease at a presymptomatic stage.

Animals↗

hNIS-IRES-eGFP dual reporter gene imaging.

The human and rodent sodium iodide symporters (NIS) have recently been cloned and are being investigated as potential therapeutic and reporter genes. We have extended this effort by constructing an internal ribosomal entry site (IRES)-linked human NIS (hNIS)-enhanced green fluorescent protein (eGFP) hybrid reporter gene for both nuclear and optical imaging. A self-inactivating retroviral vector, termed pQCNIG, containing hNIS-IRES-eGFP dual reporter gene, driven by a constitutive CMV promoter, was constructed and used to generate RG2-pQCNIG cells and RG2-pQCNIG tumors. 131I-iodide and 99mTcO4-pertechnetate accumulation studies plus fluorescence microscopy and intensity assays were performed in vitro, and gamma camera imaging studies in RG2-pQCNIG and RG2 tumor-bearing athymic rats were performed. RG2-pQCNIG cells expressed high levels of hNIS protein and showed high intensity of eGFP fluorescence compared with RG2 wild-type cells. RG2-pQCNIG cells accumulated Na131I and 99mTcO4- to a 50:1 and a 170:1 tissue/medium ratio at 10 min, compared with 0.8:1.2 tissue/medium ratio in wild-type RG2 cells. A significant correlation between radiotracer accumulation and eGFP fluorescence intensity was demonstrated. RG2-pQCNIG and RG2 tumors were readily differentiated by in vivo gamma camera imaging; radiotracer uptake increased in RG2-pQCNIG but declined in RG2 tumors over the 50-min imaging period. Stomach and thyroid were the major organs of radionuclide accumulation. The IRES-linked hNIS-eGFP dual reporter gene is functional and stable in transduced RG2-pQCNIG cells. Optical and nuclear imaging of tumors produced from these cell lines provides the opportunity to monitor tumor growth and response to therapy. These studies indicate the potential for a wider application of hNIS reporter imaging and translation into patient studies using radioisotopes that are currently available for human use for both SPECT and PET imaging.

Animals↗

A novel light source for SICM-SNOM of living cells.

We have developed a novel light source for use in a scanning near-field optical microscope (SNOM or NSOM) based on a nanopipette whose distance from the sample surface is controlled using scanning ion conductance microscopy. The light source is based on the general principle of the chemical reaction between a fluorophore in the pipette and ligand in the bath, to produce a highly fluorescent complex that is continually renewed at the pipette tip. In these experiments we used fluo-3 and calcium, respectively. This complex is then excited with an Ar+ laser, focused on the pipette tip, to produce the light source. This method overcomes the transmission problem of more traditional SNOM probes and has been used to acquire simultaneous high-resolution topographic and optical images of biological samples in physiological buffer. A resolution of approximately 220 nm topographic and approximately 190 nm optical was determined through imaging fixed sea-urchin sperm flagella. Live A6 cells were also imaged, demonstrating the potential of this system for SNOM imaging of living cells.

Aniline Compounds↗

Detection and diagnosis of oral neoplasia with an optical coherence microscope.

The use of high resolution, in vivo optical imaging may offer a clinically useful adjunct to standard histopathologic techniques. A pilot study was performed to investigate the diagnostic capabilities of optical coherence microscopy (OCM) to discriminate between normal and abnormal oral tissue. Our objective is to determine whether OCM, a technique combining the subcellular resolution of confocal microscopy with the coherence gating and heterodyne detection of optical coherence tomography, has the same ability as confocal microscopy to detect morphological changes present in precancers of the epithelium while providing superior penetration depths. We report our results using OCM to characterize the features of normal and neoplastic oral mucosa excised from 13 subjects. Specifically, we use optical coherence and confocal microscopic images obtained from human oral biopsy specimens at various depths from the mucosal surface to examine the optical properties that distinguish normal and neoplastic oral mucosa. An analysis of penetration depths achieved by the OCM and its associated confocal arm found that the OCM consistently imaged more deeply. Extraction of scattering coefficients from reflected nuclear intensity is successful in nonhyperkeratotic layers and shows differentiation between scattering properties of normal and dysplastic epithelium and invasive cancer.

Humans↗

Distinction between some saccharides in scattered optical sum frequency intensity images.

Using an optical sum frequency (SF) microscope with visible and infrared light pulses for excitation, we have attempted to distinguish among four saccharide species. The saccharides we studied were d-glucose, amylopectin, beta-cyclodextrin, and amylose. The wavelength of the infrared light was resonant to CH vibration. Amylose showed very weak sum frequency scattering for CH vibration among the four saccharides. As for the other three saccharides, we found a big difference in the sum frequency spectra of their CH stretching vibration near 2900 cm-1, when the incident visible and infrared light pulses were p- and s-polarized, respectively. Based on these facts, we have demonstrated a distinction between these three saccharides in the scattered SF intensity images.

Amylopectin↗

Measurements of capillary x-ray optics with potential for use in mammographic imaging.

Capillary optic arrays are bundles of hollow glass capillaries which guide x rays in a manner similar to the way fiber optics guide light. Focused postpatient capillary optic arrays have the potential to significantly improve both contrast and resolution of mammographic images compared to conventional antiscatter grids. Contrast can be improved by the nearly total scatter rejection of the optic. Effective resolution can be improved by geometric magnification without increased focal spot blurring. The best results were found for borosilicate glasses, with transmissions in excess of 60% for 22-cm-long fibers. To evaluate the scatter rejection properties, the transmission of off-axis radiation was measured. Transmission drops to < 1% at an angular displacement of 2.7 mrad. Transmission of a bulk capillary array dropped to near zero if the source was at an angle of 2.5 mrad. This implies excellent scatter rejection capabilities. To evaluate whether unchanneled photons might still reach the detector, absorption measurements were also performed on fibers and arrays. Absorption was found to be adequate for scatter rejection. All of the data agreed well with numerical simulations. Performance calculations for two potential optics geometries gave promising results.

Biophysical Phenomena↗

Fast and quantitative high-resolution magnetic resonance imaging of the optic nerve at 3.0 tesla.

A novel and fast magnetic resonance imaging approach for imaging the optic nerve and the surrounding cerebrospinal fluid sheath is presented. The method provides high contrast between the nerve and cerebrospinal fluid and allows for accurate quantification of the optic nerve and its cerebrospinal fluid sheath diameter within 1.5 seconds scan time. Results of a volunteer study illustrate that measurements can reliably be performed even in the distal part of the intraorbital optic nerve track. Accuracy of quantification of the new technique is demonstrated by the assessment of changes in the optic nerve and CSF sheath diameter between straight gaze and 30 degrees abduction.

Adult↗

Image evaluation of ophthalmic devices.

Methods used in the ophthalmic industry to evaluate the optical image quality of correcting lenses have remained the same over many years. This is especially true for single-vision ophthalmic lenses. With the development of new optical designs and materials for correcting refractive errors and presbyopia, new procedures for evaluating lens performance are being explored. One such method is the measurement of the modulation transfer function. Over the last 2 years, we have been measuring modulation transfer functions on a variety of single-vision and bifocal contact lenses, progressive addition spectacle lenses, holographic-diffractive lenses, and intraocular lenses. In this article, the modulation transfer function procedure and its application and results from one study on safety goggles will be presented and discussed.

Eye Protective Devices↗

Dynamic characteristics of the auditory cortex of guinea pigs observed with multichannel optical recording.

The spatiotemporal characteristics of neural activity in the guinea pig auditory cortex are investigated to determine their importance in neural processing and coding of the complex sounds. A multi-channel optical recording system has been developed for observing the cortical field of the mammalian brain in vivo. Using the voltage-sensitive dye: RH795, optical imaging was used to visualize neural activity in the guinea pig auditory cortex. Experimental results reveal a boomerang-shaped pattern of movement of activated neural cell regions for the evoked response to click as complex sounds. Parallel and sequential neural processing structure was observed. Although the exact frequency selectivities of single cells and tonotopical organization observed using microelectrode were not visible, the similar feature to the microelectrode evidences was imaged by extracting the strongly response field from the optical data.

Acoustic Stimulation↗

Molecular imaging promotes progress in orthopedic research.

Modern orthopedic research is directed towards the understanding of molecular mechanisms that determine development, maintenance and health of musculoskeletal tissues. In recent years, many genetic and proteomic discoveries have been made which necessitate investigation under physiological conditions in intact, living tissues. Molecular imaging can meet this demand and is, in fact, the only strategy currently available for noninvasive, quantitative, real-time biology studies in living subjects. In this review, techniques of molecular imaging are summarized, and applications to bone and joint biology are presented. The imaging modality most frequently used in the past was optical imaging, particularly bioluminescence and near-infrared fluorescence imaging. Alternate technologies including nuclear and magnetic resonance imaging were also employed. Orthopedic researchers have applied molecular imaging to murine models including transgenic mice to monitor gene expression, protein degradation, cell migration and cell death. Within the bone compartment, osteoblasts and their stem cells have been investigated, and the organic and mineral bone phases have been assessed. These studies addressed malignancy and injury as well as repair, including fracture healing and cell/gene therapy for skeletal defects. In the joints, molecular imaging has focused on the inflammatory and tissue destructive processes that cause arthritis. As described in this review, the feasibility of applying molecular imaging to numerous areas of orthopedic research has been demonstrated and will likely result in an increase in research dedicated to this powerful strategy. Molecular imaging holds great promise in the future for preclinical orthopedic research as well as next-generation clinical musculoskeletal diagnostics.

Animals↗

Comparison of daily megavoltage electronic portal imaging or kilovoltage imaging with marker seeds to ultrasound imaging or skin marks for prostate localization and treatment positioning in patients with prostate cancer.

PURPOSE: To compare the accuracy of imaging modalities, immobilization, localization, and positioning techniques in patients with prostate cancer. METHODS AND MATERIALS: Thirty-five patients with prostate cancer had gold marker seeds implanted transrectally and were treated with fractionated radiotherapy. Twenty of the 35 patients had limited immobilization; the remaining had a vacuum-based immobilization. Patient positioning consisted of alignment with lasers to skin marks, ultrasound or kilovoltage X-ray imaging, optical guidance using infrared reflectors, and megavoltage electronic portal imaging (EPI). The variance of each positioning technique was compared to the patient position determined from the pretreatment EPI. RESULTS: With limited immobilization, the average difference between the skin marks' laser position and EPI pretreatment position is 9.1 +/- 5.3 mm, the average difference between the skin marks' infrared position and EPI pretreatment position is 11.8 +/- 7.2 mm, the average difference between the ultrasound position and EPI pretreatment position is 7.0 +/- 4.6 mm, the average difference between kV imaging and EPI pretreatment position is 3.5 +/- 3.1 mm, and the average intrafraction movement during treatment is 3.4 +/- 2.7 mm. For the patients with the vacuum-style immobilization, the average difference between the skin marks' laser position and EPI pretreatment position is 10.7 +/- 4.6 mm, the average difference between kV imaging and EPI pretreatment position is 1.9 +/- 1.5 mm, and the average intrafraction movement during treatment is 2.1 +/- 1.5 mm. CONCLUSIONS: Compared with use of skin marks, ultrasound imaging for positioning provides an increased degree of agreement to EPI-based positioning, though not as favorable as kV imaging fiducial seeds. Intrafraction movement during treatment decreases with improved immobilization.

Gold↗

In vivo molecular and genomic imaging: new challenges for imaging physics.

The emerging and rapidly growing field of molecular and genomic imaging is providing new opportunities to directly visualize the biology of living organisms. By combining our growing knowledge regarding the role of specific genes and proteins in human health and disease, with novel ways to target these entities in a manner that produces an externally detectable signal, it is becoming increasingly possible to visualize and quantify specific biological processes in a non-invasive manner. All the major imaging modalities are contributing to this new field, each with its unique mechanisms for generating contrast and trade-offs in spatial resolution, temporal resolution and sensitivity with respect to the biological process of interest. Much of the development in molecular imaging is currently being carried out in animal models of disease, but as the field matures and with the development of more individualized medicine and the molecular targeting of new therapeutics, clinical translation is inevitable and will likely forever change our approach to diagnostic imaging. This review provides an introduction to the field of molecular imaging for readers who are not experts in the biological sciences and discusses the opportunities to apply a broad range of imaging technologies to better understand the biology of human health and disease. It also provides a brief review of the imaging technology (particularly for x-ray, nuclear and optical imaging) that is being developed to support this new field.

Animals↗

Challenges in small animal noninvasive imaging.

The current status and challenges of small animal non-invasive imaging is briefly reviewed. The advantages of non-invasive studies on living animals versus post-mortem studies are evaluated. An argument is advanced that even in post-mortem situations, non-invasive imaging may play an important role in efficiently characterizing small animal phenotypes as well as pathology. Issues of data interpretation under anesthetized conditions in live animal studies are also reviewed. The five imaging technologies covered include CT, PET, ultrasound, MRI and optical imaging. The structural and physiological information content of these different modalities is reviewed along with the ability of these techniques to scale down for use in small mammals such as mice and rats. In general, it was found that most of these technologies scale favorably to the study of small mammals, generally providing more physiological information than when used on the larger human scale. This suggests that these types of small mammal imaging capabilities will play a very significant role in the full utilization of these important animal models in biomedical research.

Anatomy, Cross-Sectional↗

A low-cost CD-ROM--based image archival system.

Many radiologists have large collections of original or copied radiographs, as well as 35-mm slides of radiographs that require conventional carousel-type projectors for display. These images cannot be digitally manipulated or displayed in other formats. The authors used compact disk, read-only memory (CD-ROM) technology as a low-cost method of digitally storing these images. The CD-ROM disks were created from slide images optically scanned and digitally transferred to a disk. The images may be incorporated into any type of computer application, used on multiple computer platforms, and are easily transportable. The process is a low-cost, high-quality method of transferring images to digital media and is currently available to anyone with a conventional 35-mm camera, a CD-ROM reader, and a computer.

CD-ROM↗

Imaging islets labeled with magnetic nanoparticles at 1.5 Tesla.

We have developed a magnetic resonance imaging (MRI) technique for imaging Feridex (superparamagnetic iron oxide [SPIO])-labeled islets of Langerhans using a standard clinical 1.5-Tesla (T) scanner and employing steady-state acquisition imaging sequence (3DFIESTA). Both porcine and rat islets were labeled with SPIO by a transfection technique using a combination of poly-l-lysine and electroporation. Electron microscopy demonstrated presence of SPIO particles within the individual islet cells, including beta-cells and particles trapped between cell membranes. Our labeling method produced a transfection rate of 860 pg to 3.4 ng iron per islet, dependent on the size of the islet. The labeling procedure did not disrupt either the function or viability of the islets. In vitro 3DFIESTA magnetic resonance images of single-labeled islets corresponded with their optical images. In vivo T2*-weighted scan using 1.5 T detected as few as 200 SPIO-labeled islets transplanted under rat kidney capsule, which correlated with immunohistochemistry of the transplant for insulin and iron. Ex vivo 3DFIESTA images of kidneys containing 200, 800 or 2,000 SPIO-labeled islet isografts showed good correlation between signal loss and increasing numbers of islets. These data provide evidence that islets can be labeled with SPIO and imaged using clinically available 1.5- T MRI.

Animals↗