Refining neural network predictions for helical transmembrane proteins by dynamic programming.

For transmembrane proteins experimental determination of three-dimensional structure is problematic. However, membrane proteins have important impact for molecular biology in general, and for drug design in particular. Thus, prediction method are needed. Here we introduce a method that started from the output of the profile-based neural network system PHDhtm (Rost, et al. 1995). Instead of choosing the neural network output unit with maximal value as prediction, we implemented a dynamic programming-like refinement procedure that aimed at producing the best model for all transmembrane helices compatible with the neural network output. The refined prediction was used successfully to predict transmembrane topology based on an empirical rule for the charge difference between extra- and intra-cytoplasmic regions (positive-inside rule). Preliminary results suggest that the refinement was clearly superior to the initial neural network system; and that the method predicted all transmembrane helices correctly for more proteins than a previously applied empirical filter. The resulting accuracy in predicting topology was better than 80%. Although a more thorough evaluation of the method on a larger data set will be required, the results compared favourably with alternative methods. The results reflected the strength of the refinement procedure which was the successful incorporation of global information: whereas the residue preferences output by the neural network were derived from stretches of 17 adjacent residues, the refinement procedure involved constraints on the level of the entire protein.

Algorithms↗

[Simultaneous spectrophotometric determination of multicomponent mixtures by a soft thresholding wavelet-based radial basis function neural network].

A Soft Thresholding Wavelet-based Radial Basis Function Neural network (STWRBFN) method was developed to perform simultaneous quantitative analysis of multicomponent mixtures. The quality of noise removal and regression was improved by combining wavelet soft thresholding with radial basis function neural network. Through optimization, the wavelet function, wavelet decomposition level (L), thresholding method and spread parameter sigma of RBFN were selected. Two-programs, i.e. PSTWRBFN and PRBFN, were designed to perform STWRBFN and RBFN calculations. Experimental results showed the STWRBFN method to be successful and better than RBFN. Comparing with classical multivariate linear regression, both the methods were more powerful.

Algorithms↗

Classification of clustered microcalcifications using a Shape Cognitron neural network.

A new shape recognition-based neural network built with universal feature planes, called Shape Cognitron (S-Cognitron) is introduced to classify clustered microcalcifications. The architecture of S-Cognitron consists of two modules and an extra layer, called 3D figure layer lies in between. The first module contains a shape orientation layer, built with 20 cell planes of low level universal shape features to convert first-order shape orientations into numeric values, and a complex layer, to extract second-order shape features. The 3D figure layer is a feature extract-display layer that extracts the shape curvatures of an input pattern and displays them as a 3D figure. It is then followed by a second module made up of a feature formation layer and a probabilistic neural network-based classification layer. The system is evaluated by using Nijmegen mammogram database and experimental results show that sensitivity and specificity can reach 86.1 and 74.1%, respectively.

Algorithms↗

Optimizing the monitoring strategy of wastewater treatment plants by multiobjective neural networks approach.

This paper applies artificial neural network (ANN) to model the observed effluent quality data. The ANN's structure, involving the number of hidden layer and node and their connection, is determined endogenously by resorting to the compromise of data cost minimization and prediction accuracy maximization. To obtain the best compromise possible, the model introduces an aspiration variable (micro) that represents the level of aspiration achieved in one objective and the conjugate of micro, (1 - micro), represents level of aspiration achieved in the other objective. Because a massive amount of calculation is required, the model applies genetic algorithm (GA) for its computational flexibility and capability to ensure global solution. Feasibility and practicality of the model is tested by a case study with a set of 150 daily observations on 17 operational variables and quality parameters at an industrial wastewater treatment plant (WTP) located in southern Taiwan. Of these 17 variables open to selection, only 6 variables, wastewater flow rate (Q), CN(-), SS, MLSS, pH and COD are selected by the model to achieve the maximum accuracy of prediction, 0.94, with a total cost of 5,950 NT$. By constraining budget availability, the variables included in the model are reduced in number, causing a concomitant reduction in prediction accuracy, that is, by varying micro (aspiration level of accuracy), a trajectory of cost and accuracy is generated. The calculation results a cost of 3,650 NT$ and 0.54 accuracy for the case with variables including flow rate, SCN(-) and SS in equalization basin; aeration tank hydraulic retention time (HRT) and percentage of returned sludge (R%) are selected for building the prediction model when the importance of required budget is equal to the accuracy of prediction model. In addition, when required cost for building ANN model is between 3,650 NT$ and 3,900 NT$, the marginal return of budget input is highest in the entire range of calculation.

Algorithms↗

Improving medical diagnostic accuracy of ultrasound Doppler signals by combining neural network models.

There are a number of different quantitative models that can be used in a medical diagnostic decision support system including parametric methods (linear discriminant analysis or logistic regression), nonparametric models (k nearest neighbor or kernel density) and several neural network models. The complexity of the diagnostic task is thought to be one of the prime determinants of model selection. Unfortunately, there is no theory available to guide model selection. This paper illustrates the use of combined neural network models to guide model selection for diagnosis of ophthalmic and internal carotid arterial disorders. The ophthalmic and internal carotid arterial Doppler signals were decomposed into time-frequency representations using discrete wavelet transform and statistical features were calculated to depict their distribution. The first-level networks were implemented for the diagnosis of ophthalmic and internal carotid arterial disorders using the statistical features as inputs. To improve diagnostic accuracy, the second-level networks were trained using the outputs of the first-level networks as input data. The combined neural network models achieved accuracy rates which were higher than that of the stand-alone neural network models.

Adult↗

Automatic embolus detection by a neural network.

BACKGROUND AND PURPOSE: Embolus detection using transcranial Doppler ultrasound is a useful method for the identification of active embolic sources in cerebrovascular diseases. Automated embolus detection systems have been developed to reduce the time of evaluation in long-term recordings and to provide more "objective" criteria. The purpose of this study was to evaluate the critical conditions of automated embolus detection by means of a trained neural network (EMBotec V5.1 One, STAC GmbH, Germany). METHODS: In 11 normal volunteers and in 11 patients with arterial or cardiac embolic sources, we performed simultaneous recordings from both middle or both posterior cerebral arteries. In the normal subjects, we produced 1342 additional artifacts to use the latter as false-positives. Detection of microembolic signals (MES) was done offline from digital audiotapes (1) by an experienced blinded investigator used as a reference and (2) by a trained 3-layer-feed-forward neural network. RESULTS: From the 1342 provoked artifacts the neural network labeled 216 events as microemboli, yielding an artifact rejection of 85%. In microembolus-positive patients the neural network detected 282 events as emboli, among these 122 signals originating from artifacts; 58 "real" events were not detected. This result revealed a sensitivity of 73.4% and a positive predictive value of 56.7. The spectral power of the detected artifact signals was 16.5+/-5 dB above background signal. MES from patients with artificial heart valves had a spectral power of 6.4+/-2.1 dB; however, in patients with other sources of emboli, MES had an averaged energy reflection of 2.7+/-0.9 dB. CONCLUSIONS: The neural network is a promising tool for automated embolus detection, the formal algorithm for signal identification is unknown. However, extreme signal qualities, eg, strong artifacts, lead to misdiagnosis. Similar to other automated embolus detection systems, good signal quality and verification of MES by an experienced investigator is still mandatory.

Adult↗

Comparison of artificial neural network and logistic regression models for prediction of mortality in head trauma based on initial clinical data.

BACKGROUND: In recent years, outcome prediction models using artificial neural network and multivariable logistic regression analysis have been developed in many areas of health care research. Both these methods have advantages and disadvantages. In this study we have compared the performance of artificial neural network and multivariable logistic regression models, in prediction of outcomes in head trauma and studied the reproducibility of the findings. METHODS: 1000 Logistic regression and ANN models based on initial clinical data related to the GCS, tracheal intubation status, age, systolic blood pressure, respiratory rate, pulse rate, injury severity score and the outcome of 1271 mainly head injured patients were compared in this study. For each of one thousand pairs of ANN and logistic models, the area under the receiver operating characteristic (ROC) curves, Hosmer-Lemeshow (HL) statistics and accuracy rate were calculated and compared using paired T-tests. RESULTS: ANN significantly outperformed logistic models in both fields of discrimination and calibration but under performed in accuracy. In 77.8% of cases the area under the ROC curves and in 56.4% of cases the HL statistics for the neural network model were superior to that for the logistic model. In 68% of cases the accuracy of the logistic model was superior to the neural network model. CONCLUSIONS: ANN significantly outperformed the logistic models in both fields of discrimination and calibration but lagged behind in accuracy. This study clearly showed that any single comparison between these two models might not reliably represent the true end results. External validation of the designed models, using larger databases with different rates of outcomes is necessary to get an accurate measure of performance outside the development population.

Adolescent↗

Global dissipativity of continuous-time recurrent neural networks with time delay.

This paper addresses the global dissipativity of a general class of continuous-time recurrent neural networks. First, the concepts of global dissipation and global exponential dissipation are defined and elaborated. Next, the sets of global dissipativity and global exponentially dissipativity are characterized using the parameters of recurrent neural network models. In particular, it is shown that the Hopfield network and cellular neural networks with or without time delays are dissipative systems.

Journal Article↗

Medical image processing utilizing neural networks trained on a massively parallel computer.

While finding many applications in science, engineering, and medicine, artificial neural networks (ANNs) have typically been limited to small architectures. In this paper, we demonstrate how very large architecture neural networks can be trained for medical image processing utilizing a massively parallel, single-instruction multiple data (SIMD) computer. The two- to three-orders of magnitude improvement in processing time attainable using a parallel computer makes it practical to train very large architecture ANNs. As an example we have trained several ANNs to demonstrate the tomographic reconstruction of 64 x 64 single photon emission computed tomography (SPECT) images from 64 planar views of the images. The potential for these large architecture ANNs lies in the fact that once the neural network is properly trained on the parallel computer the corresponding interconnection weight file can be loaded on a serial computer. Subsequently, relatively fast processing of all novel images can be performed on a PC or workstation.

Computer Systems↗

Parallel principal component neural networks for classification of event-related potential waveforms.

Artificial neural networks (ANNs) are discussed in terms of classification of brain auditory event-related potentials (ERPs). A new ANN architecture for the classification of ERPs is proposed. The new architecture is called the parallel principal component neural network (PPCNN). The use of the PPCNN for classification of ERP data obtained from both normal control subjects and chronic schizophrenic patients is discussed. Experimental results are given.

Adult↗

A Sequential Learning Approach for Single Hidden Layer Neural Networks.

A sequential orthogonal approach to the building and training of single hidden layer neural networks is presented in this paper. In the proposed method, hidden neurons are added one at a time. The procedure starts with a single hidden neuron and sequentially increases the number of hidden neurons until the model error is sufficiently small. When adding a neuron, the new information introduced by this neuron is caused by that part of its output vector which is orthogonal to the space spanned by the output vectors of previously added hidden neurons. The classical Gram-Schmidt orthogonalization method is used at each step to form a set of orthogonal bases for the space spanned by the output vectors of hidden neurons. Hidden layer weights are found through optimization while output layer weights are obtained from the least-squares regression. Using the proposed technique, it is possible to determine the necessary number of hidden neurons required. A regularization factor is also incorporated into the sequential orthogonal training algorithm to improve the network generalization capability. An additional advantage of this method is that it can be used to build and train neural networks with mixed types of hidden neurons and thus to develop hybrid models. By using mixed types of neurons, it is found that more accurate neural network models, with a smaller number of hidden neurons than seen in conventional networks, can be developed. The proposed sequential orthogonal training method was successfully applied to three non-linear modelling examples.

Journal Article↗

A general purpose neural network simulator system for medical data processing.

We developed a general purpose neural network simulator system for medical data processing. This system has a flexible network definition language. Users can define arbitrary hierarchical neural networks using the definition language to analyze medical data that contains some complex patterns. The learning algorithm used in this system is back propagation. Learning curves are displayed on multiple windows. This is a general purpose system, so it can be used for various kinds of medical data processing such as one dimensional signal processing or two dimensional image processing. The system can run on a standard UNIX workstation, which is faster and more powerful than most personal computers. The system needs an X window system/Motif and C compiler. These are standard system programs already available on most UNIX workstations. The source code of the system can be retrieved from our anonymous ftp site via Internet.

Algorithms↗

Examination of electric field effects on tissues by using back propagation neural network.

The aim of this study is to determine lipid peroxidation and antioxidant enzyme levels in spleen and testis tissues of guinea pigs which were exposed to different intensities and periods of DC (direct current) and AC (alternating current) electric fields. The experimental results are applied to neural networks as learning data and the training of the feed forward neural network is realized. At the end of this training; without applying electric field to the tissues, the determination of the effects of the electric field on tissues by using computer is predicted by the neural network. After the experiments, the prediction of the neural network is averagely 99%.

Animals↗

A comparison of Cox proportional hazards and artificial neural network models for medical prognosis.

Modeling survival of populations and establishing prognoses for individual patients are important activities in the practice of medicine. For patients with diseases that may extend for several years, in particular, accurate assessment of survival probabilities is essential. New methods, such as neural networks, have been used increasingly to model disease progression. Their advantages and disadvantages, when compared to statistical methods such as Cox proportional hazards, have seldom been explored in real-world data. In this study, we compare the performances of a Cox model and a neural network model that are used as prognostic tools for a set of people living with AIDS. We modeled disease progressions for patients who had AIDS (according to the 1993 CDC definition) in a set of 588 patients in California, using data from the ATHOS project. We divided the study population into 10 training and 10 test sets and evaluated the prognostic accuracy of a Cox proportional hazards model and of a neural network model by determining sensitivities, specificities, positive and negative predictive values for an arbitrary threshold (0.5), and the areas under the receiver operating characteristics (ROC) curves that utilized all possible thresholds for intervals of 1 yr following the diagnosis of AIDS. There was no evidence that the Cox model performed better than did the neural network model or vice versa, but the former method had the advantage of providing some insight on which variables were most influential for prognosis. Nevertheless, it is likely that the assumptions required by the Cox model may not be satisfied in all data sets, justifying the use of neural networks in certain cases.

Acquired Immunodeficiency Syndrome↗

Detection of basal cell carcinoma using electrical impedance and neural networks.

Variations in electrical impedance over frequency might be used to distinguish basal cell carcinoma (BCC) from benign skin lesions, although the patterns that separate the two are nonobvious. Artificial neural networks (ANNs) may be good pattern classifiers for this application. A preliminary study to show the potential of neural networks to distinguish benign from malignant skin lesions using electrical impedance is presented. Electrical impedance was measured in vivo from 1 kHz to 1 MHz at five virtual depths on 18 BCC and 16 benign or premalignant lesions. A feed-forward neural network was trained using back propagation to classify these lesions. Two methods of preprocessing were used to account for the impedance of normal skin and the size of the lesion, one based on estimating the impedance of the lesion relative to adjacent normal skin and one based on estimating the impedance of the lesion independent of size or surrounding normal skin. Neural networks were able to classify measurements in a test set with 100% accuracy for the first preprocessing technique and 85% accuracy for the second. These results indicate electrical impedance may be a promising clinical diagnostic tool for basal cell carcinoma or other forms of skin cancer.

Algorithms↗

Neural-network applications for analysis of adverse drug reactions.

A neural-network analysis has been applied to predict adverse or side effects of drugs using a database of antidepressant agents with known effects as well as input from a database with both patient parameters and drug information. A NeuralWork software package was implemented on a Macintosh Quadra 700 and trained on a database of ten drugs with known adverse effects. Another agent (not in the database) was used to test the ability of the network to predict the relative incidence of its side effects. Despite the small number of drugs used for training, the adverse effects of some drugs, such as doxepin, were predicted with 90-100% accuracy. These results indicate that neural-network analysis can be used to predict adverse drug effects for drugs within a given class and ultimately can be extended to include patient parameters to predict the mechanisms of action of drugs from relatively large databases.

Adverse Drug Reaction Reporting Systems↗

Development of a neural network screening aid for diagnosing lower limb peripheral vascular disease from photoelectric plethysmography pulse waveforms.

An artificial neural network (ANN) was trained to classify photoelectric plethysmographic (PPG) pulse waveforms for the diagnosis of lower limb peripheral vascular disease (PVD). PPG pulses from the lower limbs, and pre- and post-exercise Doppler ultrasound ankle to brachial systolic blood pressure ratio measurements were obtained from patients referred to a vascular investigation laboratory. A single PPG pulse from the big toe of each leg was processed and normalized, and used as input data to the ANN. The ANN outputs represented the diagnostic classifications (normal, significant PVD and major PVD) and the ANN was trained with the ankle to brachial pressure indices (ABPI). The ANN structure consisted of an input layer (50 neuron units from the PPG pulse input), a single hidden layer (15 neurons) and an output layer (3 neurons for the PVD diagnoses). The back-propagation learning algorithm was used to train the ANN for 500 epochs with a PPG training set of pulses from 100 legs. Test data for network assessment comprised pulses from a further 50 legs (20 normal and 30 PVD, of which 15 were categorized as having major disease). A network sensitivity of 93% and specificity of 85% was achieved with respect to the Doppler ABPI standard, giving a diagnostic accuracy of 90%. The results of this study indicate that a neural network can be trained to distinguish between PPG pulses from normal and diseased lower limb arteries. The simplicity of PPG measurement and neural network classification holds promise for the screening of lower limb arterial PVD.

Humans↗

Quantification of ternary mixtures of heavy metal cations from metallochromic absorbance spectra using neural network inversion.

A new method based on artificial neural networks (ANN) for the processing of spectrophotometric data is proposed and illustrated on the example of the simultaneous quantification of ternary mixtures of zinc, cadmium, and mercury cations in aqueous solutions. Three types of commercially available metallochromic indicators were used as a simple model setup to create spectral data analogous to those normally received from an optical sensor array. In conventional ANN training methods for chemical sensors based on spectrophotometric data, a calibration is established by mathematically correlating the measured optical signal as network input with the concentration of the calibration sample as network output. In several situations, however, especially when dealing with mixed sample solutions, the relationship between a measured absorption spectrum and the corresponding ion concentrations is ambiguous, resulting in an "ill-posed problem". On the other hand, if the training direction is reversed by correlating known sample concentrations with measured optical signals, the relationship becomes reasonable for the ANN to obtain its structure. The proposed model illustrated in this paper is based on a more reasonable direct mapping and estimation by artificial neural network inversion (ANNI). In the training step, sample mixtures of known concentrations are optically measured to construct networks correlating the input data (ion concentrations) and the output data (absorption spectra). In the estimation step, the ion concentrations of unknown samples are estimated using the constructed ANN. The measured spectra of the unknown samples are fed to the output layer, and the appropriate input concentrations are determined by ANNI. When training the ANN system with 143 ternary mixtures of Zn2+, Cd2+, and Hg2+ in a concentration range from 1 to 100 microM, root-mean-square errors of prediction (RMSEP) of 0.45 (Zn2+), 0.96 (Cd2+), and 0.32 microM (Hg2+) were observed for the estimation of concentrations in 30 test samples, using the ANNI procedure. This newly proposed model, which involves the construction of an ANN based on direct mapping and estimation by ANNI, opens up one way to overcome the limitations of nonselective sensors, allowing the use of more easily accessible semiselective receptors to realize smart chemical sensing systems.