Dental implants in patients with type 2 diabetes mellitus: a clinical study.

PURPOSE: Systemic factors, such as diabetes mellitus, can influence the success rate of dental implants. The authors describe their experience using the MIS implant system (Medical Implant System, Shlomi, Israel) for retention of overdentures in patients with type 2 diabetes mellitus and provide data regarding the level of satisfaction of the patients, the improvement of function, mucosal and periimplant health, and bone level around implants in this group. METHODS: The study group consisted of 41 patients with type 2 diabetes mellitus who received 141 implants for retention of overdentures. RESULTS: The success rate was 97.3% and 94.4% 1 and 5 years following implantation, respectively. The majority of patients reported improvement of function following the new treatment. A high correlation was observed between mucosal health and improvement of function. No correlation was found between failed implants and glucose level. CONCLUSION: The clinical outcome of dental implants in a selected group of patients with well-controlled type 2 diabetes mellitus is satisfying and encouraging. Further investigations and clinical trials over a longer period of time are needed to determine the long-term survival of implants in diverse groups of patients with diabetes mellitus.

Aged↗

Standardized evaluation methodology for 2-D-3-D registration.

In the past few years, a number of two-dimensional (2-D) to three-dimensional (3-D) (2-D-3-D) registration algorithms have been introduced. However, these methods have been developed and evaluated for specific applications, and have not been directly compared. Understanding and evaluating their performance is therefore an open and important issue. To address this challenge we introduce a standardized evaluation methodology, which can be used for all types of 2-D-3-D registration methods and for different applications and anatomies. Our evaluation methodology uses the calibrated geometry of a 3-D rotational X-ray (3DRX) imaging system (Philips Medical Systems, Best, The Netherlands) in combination with image-based 3-D-3-D registration for attaining a highly accurate gold standard for 2-D X-ray to 3-D MR/CT/3DRX registration. Furthermore, we propose standardized starting positions and failure criteria to allow future researchers to directly compare their methods. As an illustration, the proposed methodology has been used to evaluate the performance of two 2-D-3-D registration techniques, viz. a gradient-based and an intensity-based method, for images of the spine. The data and gold standard transformations are available on the internet (http://www.isi.uu.nl/Research/Databases/).

Algorithms↗

Monitoring cardiac output using the femoral and radial arterial pressure waveform.

This study was performed to determine the interchangeability of femoral artery pressure and radial artery pressure measurements as the input for the PiCCO system (Pulsion Medical Systems, Munich, Germany). We studied 15 intensive care patients following cardiac surgery. Five-second averages of the cardiac output derived from the femoral artery pressure (COfem) were compared to 5-s averages derived from the radial artery pressure (COrad). One patient was excluded due to problems in the pattern recognition of the arterial pressure signal. In the remaining 14 patients, 14 734 comparative cardiac output values were analysed. The mean sample time was 88 min, range [30-119 min]. Mean (SD) COfem was 6.24 (1.1) l.min(-1) and mean COrad 6.23 (1.1) l.min(-1). Bland-Altman analysis showed an excellent agreement with a bias of - 0.01 l.min(-1), and limits of agreement from 0.60 to - 0.62 l.min(-1). If changes in CO were > 0.5 l.min(-1), the direction of changes in COfem and COrad were equal in 97% of instances. We conclude that femoral artery pressure and radial artery pressure are interchangeable as inputs for the PiCCO device.

Aged↗

Pulmonary artery thermodilution cardiac output vs. transpulmonary thermodilution cardiac output in two patients with intrathoracic pathology.

In two adult patients, one with a severe hemorrhage and one with a partial anomalous pulmonary vein, cardiac output (CO) measurements were performed simultaneously by means of the bolus transpulmonary thermodilution technique (COao) and continuous pulmonary artery thermodilution method (CCOpa). In both cases, the methods revealed clinically significant different cardiac output values based upon the site of measurement and the underlying pathology. The assessment of cardiac output (CO) is considered an important part of cardiovascular monitoring of the critically ill patient. Cardiac output is most commonly determined intermittently by the bolus thermodilution technique with a pulmonary artery catheter (COpa). As continuous monitoring of CO is preferable to this intermittent technique, two major techniques have been proposed. Firstly, a nearly continuous thermodilution method (CCOpa) using a heating filament mounted on a pulmonary artery catheter (Baxter Edwards Laboratories, Irvine, CA), with a clinically acceptable accuracy compared with the intermittent bolus technique. Based on these results we assumed CCOpa equivalent to real CO during hemodynamically stable conditions, and secondly, a continuous cardiac output system based on pulse contour analysis (PCCO), such as the PiCCO system (Pulsion Medical System, Munchen, Germany). To calibrate this device, which uses a derivation of the algorithm of Wesseling and colleagues, an independently obtained value of CO by the transpulmonary thermodilution method (COao) is used. Clinical validation studies in patients without underlying intrathoracic pathology, comparing transpulmonary COao with the pulmonary technique (COpa), mostly yielded good agreement.

Aged↗

T wave complexity in patients with hypertrophic cardiomyopathy.

The complexity of the T wave assessed by principal component analysis (PCA) has been proposed to reflect abnormal repolarization, which may be arrhythmogenic. To determine whether PCA can differentiate patients with hypertrophic cardiomyopathy (HCM) from normal subjects and whether PCA is of prognostic importance in HCM, 112 patients with HCM (41 +/- 14 years, 64 males) and 72 healthy subjects (39 +/- 9 years, 41 males) were studied. Patients with sinus node dysfunction, AV conduction block, flat T waves, QRS > 140 ms, and those < 15 years were excluded from this study. Standard 12-lead ECGs were recorded digitally using the MAC-VU system (Marquette Medical Systems). PCA parameters were computed using the QT Guard software package by Marquette. PCA ratio was significantly greater in HCM patients than in normal controls (23.9% +/- 12.4% vs 16.1% +/- 7.6%, P < 0.0001) and was correlated with QT-end dispersion (r = 0.24, P = 0.01) and QT peak (Q point to T peak) dispersion (r = 0.35, P < 0.0001). HCM patients with syncope (n = 23) had increased PCA ratios compared with those without syncope (29.1% +/- 11.5% vs 22.5% +/- 12.3%, P = 0.01). PCA ratio was similar in patients with and without nonsustained ventricular tachycardia on Holter (25.9% +/- 11.4% vs 22.7% +/- 12.1%, P = 0.2), as well as in patients treated with amiodarone or sotalol versus those not on therapy. In conclusion, assessment of the complexity of the T wave by PCA differentiates HCM patients from normal subjects. PCA ratio correlated with QT dispersion and an increased PCA ratio was associated with a history of syncope in HCM.

Adult↗

Effect of multileaf collimator leaf width on physical dose distributions in the treatment of CNS and head and neck neoplasms with intensity modulated radiation therapy.

The purpose of this work is to examine physical radiation dose differences between two multileaf collimator (MLC) leaf widths (5 and 10 mm) in the treatment of CNS and head and neck neoplasms with intensity modulated radiation therapy (IMRT). Three clinical patients with CNS tumors were planned with two different MLC leaf sizes, 5 and 10 mm, representing Varian-120 and Varian-80 Millennium multileaf collimators, respectively. Two sets of IMRT treatment plans were developed. The goal of the first set was radiation dose conformality in three dimensions. The goal for the second set was organ avoidance of a nearby critical structure while maintaining adequate coverage of the target volume. Treatment planning utilized the CadPlan/Helios system (Varian Medical Systems, Milpitas CA) for dynamic MLC treatment delivery. All beam parameters and optimization (cost function) parameters were identical for the 5 and 10 mm plans. For all cases the number of beams, gantry positions, and table positions were taken from clinically treated three-dimensional conformal radiotherapy plans. Conformality was measured by the ratio of the planning isodose volume to the target volume. Organ avoidance was measured by the volume of the critical structure receiving greater than 90% of the prescription dose (V(90)). For three patients with squamous cell carcinoma of the head and neck (T2-T4 N0-N2c M0) 5 and 10 mm leaf widths were compared for parotid preservation utilizing nine coplanar equally spaced beams delivering a simultaneous integrated boost. Because modest differences in physical dose to the parotid were detected, a NTCP model based upon the clinical parameters of Eisbruch et al. was then used for comparisons. The conformality improved in all three CNS cases for the 5 mm plans compared to the 10 mm plans. For the organ avoidance plans, V(90) also improved in two of the three cases when the 5 mm leaf width was utilized for IMRT treatment delivery. In the third case, both the 5 and 10 mm plans were able to spare the critical structure with none of the structure receiving more than 90% of the prescription dose, but in the moderate dose range, less dose was delivered to the critical structure with the 5 mm plan. For the head and neck cases both the 5 and 10 x 2.5 mm beamlets dMLC sliding window techniques spared the contralateral parotid gland while maintaining target volume coverage. The mean parotid dose was modestly lower with the smaller beamlet size (21.04 Gy v 22.36 Gy). The resulting average NTCP values were 13.72% for 10 mm dMLC and 8.24% for 5 mm dMLC. In conclusion, five mm leaf width results in an improvement in physical dose distribution over 10 mm leaf width that may be clinically relevant in some cases. These differences may be most pronounced for single fraction radiosurgery or in cases where the tolerance of the sensitive organ is less than or close to the target volume prescription.

Dose-Response Relationship, Radiation↗

4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT.

We propose a new scanning protocol for generating 4D-CT image data sets influenced by respiratory motion. A cine scanning protocol is used during data acquisition, and two registration methods are used to sort images into temporal phases. A volume is imaged in multiple acquisitions of 1 or 2 cm length along the cranial-caudal direction. In each acquisition, the scans are continuously acquired for a time interval greater than or equal to the average respiratory cycle plus the duration of the data for an image reconstruction. The x ray is turned off during CT table translation and the acquisition is repeated until the prescribed volume is completely scanned. The scanning for 20 cm coverage takes about 1 min with an eight-slice CT or 2 mins with a four-slice CT. After data acquisition, the CT data are registered into respiratory phases based on either an internal anatomical match or an external respiratory signal. The internal approach registers the data according to correlation of anatomy in the CT images between two adjacent locations in consecutive respiratory cycles. We have demonstrated the technique with ROIs placed in the region of diaphragm. The external approach registers the image data according to an externally recorded respiratory signal generated by the Real-Time Position Management (RPM) Respiratory Gating System (Varian Medical Systems, Palo Alto, CA). Compared with previously reported prospective or retrospective imaging of the respiratory motion with a single-slice or multi-slice CT, the 4D-CT method proposed here provides (1) a shorter scan time of three to six times faster than the single-slice CT with prospective gating; (2) a shorter scan time of two to four times improvement over a previously reported multi-slice CT implementation, and (3) images over all phases of a breathing cycle. We have applied the scanning and registration methods on phantom, animal and patients, and initial results suggest the applicability of both the scanning and the registration methods.

Algorithms↗

Evaluation of polymer gels and MRI as a 3-D dosimeter for intensity-modulated radiation therapy.

BANG gel (MGS Research, Inc., Guilford, CT) has been evaluated for measuring intensity-modulated radiation therapy (IMRT) dose distributions. Treatment plans with target doses of 1500 cGy were generated by the Peacock IMRT system (NOMOS Corp., Sewickley, PA) using test target volumes. The gels were enclosed in 13 cm outer diameter cylindrical glass vessels. Dose calibration was conducted using seven smaller (4 cm diameter) cylindrical glass vessels irradiated to 0-1800 cGy in 300 cGy increments. Three-dimensional maps of the proton relaxation rate R2 were obtained using a 1.5 T magnetic resonance imaging (MRI) system (Siemens Medical Systems, Erlangen, Germany) and correlated with dose. A Hahn spin echo sequence was used with TR = 3 s, TE = 20 and 100 ms, NEX = 1, using 1 x 1 x 3 mm3 voxels. The MRI measurements were repeated weekly to identify the gel-aging characteristics. Ionization chamber, thermoluminescent dosimetry (TLD), and film dosimetry measurements of the IMRT dose distributions were obtained to compare against the gel results. The other dosimeters were used in a phantom with the same external cross-section as the gel phantom. The irradiated R2 values of the large vessels did not precisely track the smaller vessels, so the ionization chamber measurements were used to normalize the gel dose distributions. The point-to-point standard deviation of the gel dose measurements was 7.0 cGy. When compared with the ionization chamber measurements averaged over the chamber volume, 1% agreement was obtained. Comparisons against radiographic film dose distribution measurements and the treatment planning dose distribution calculation were used to determine the spatial localization accuracy of the gel and MRI. Spatial localization was better than 2 mm, and the dose was accurately determined by the gel both within and outside the target. The TLD chips were placed throughout the phantom to determine gel measurement precision in high- and low-dose regions. A multidimensional dose comparison tool that simultaneously examines the dose-difference and distance-to-agreement was used to evaluate the gel in both low-and high-dose gradient regions. When 3% and 3 mm criteria were used for the comparisons, more than 90% of the TLD measurements agreed with the gel, with the worst of 309 TLD chip measurements disagreeing by 40% of the criteria. All four MRI measurement session gel-measured dose distributions were compared to evaluate the time behavior of the gel. The low-dose regions were evaluated by comparison with TLD measurements at selected points, while high-dose regions were evaluated by directly comparing measured dose distributions. Tests using the multidimensional comparison tool showed detectable degradation beyond one week postirradiation, but all low-dose measurements passed relative to the test criteria and the dose distributions showed few regions that failed.

Biophysical Phenomena↗

Interventional and intraoperative magnetic resonance imaging.

The goal of the Image Guided Therapy Program, as the name implies, is to develop the use of imaging to guide minimally invasive therapy. The program combines interventional and intraoperative magnetic resonance imaging (MRI) with high-performance computing and novel therapeutic devices. In clinical practice the multidisciplinary program provides for the investigation of a wide range of interventional and surgical procedures. The Signa SP 0.5 T superconducting MRI system (GE Medical Systems, Milwaukee, WI) has a 56-cm-wide vertical gap, allowing access to the patient and permitting the execution of interactive MRI-guided procedures. This system is integrated with an optical tracking system and utilizes flexible surface coils and MRI-compatible displays to facilitate procedures. Images are obtained with routine pulse sequences. Nearly real-time imaging, with fast gradient-recalled echo sequences, may be acquired at a rate of one image every 1.5 s with interactive image plane selection. Since 1994, more than 800 of these procedures, including various percutaneous procedures and open surgeries, have been successfully performed at Brigham and Women's Hospital (Boston, MA).

Biomedical Engineering↗

Clinical significance of immunocytochemical detection of tumor cells using digital microscopy in peripheral blood and bone marrow of breast cancer patients.

PURPOSE: The presence of tumor cells in bone marrow has been reported to represent an important prognostic indicator in breast cancer, but the clinical significance of circulating cells in peripheral blood is less well known. The aim of this study was to evaluate the feasibility of identifying cytokeratin (CK)-expressing cells in peripheral blood with an automat-assisted immunohistochemical detection system and to compare it with detection of tumor cells in bone marrow samples. EXPERIMENTAL DESIGN: Cytospun Ficoll fractions of peripheral blood and bone marrow were obtained simultaneously in 114 breast cancer patients at different stages of the disease (I to IV) before treatment with chemotherapy. The pancytokeratin (CK) monoclonal antibody A45-B/B3 (anti-CKs 8, 18, and 19) was used for epithelial cell detection. Immunostained cells were detected by an automated cellular imaging system (ChromaVision Medical System). RESULTS: CK+ cells were detected in 28 (24.5%) patients in blood and in 67 (59%) patients in bone marrow. Twenty-six (93%) patients with CK-positive cells in blood also had positive bone marrow (P < 0.001). Positive cells were detected in peripheral blood in 3/39 (7.5%) operable breast cancers (stage I/II), 9 of 36 (25%) locally advanced breast cancers (stage III), and 16 of 39 (41%) patients with metastatic disease (stage IV; P = 0.017). In the subgroup of nonmetastatic patients (n = 75), prognostic factors for poor disease-free survival were: absence of estrogen receptor; presence of CK+ cells in bone marrow (P = 0.012); clinical nodal involvement; large tumor size (T4); and presence of tumor emboli. Presence of circulating CK+ cells in the peripheral blood was not statistically correlated with disease-free survival. On multivariate analysis, independent indicators for disease-free survival were: absence of estrogen receptor (P = 0.043) and presence of CK+ cells in bone marrow (P = 0.076). CONCLUSIONS: The clinical relevance of circulating epithelial cells as a prognostic factor is not supported by the present data, especially in comparison with tumor cells in the bone marrow. However, this method of detection may be useful to monitor the efficacy of treatment in advanced or metastatic breast cancer.

Bone Marrow Cells↗

Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting.

STUDY OBJECTIVES: Stroke volume variation (SVV) and pulse pressure variation (PPV) determined by the PiCCOplus system (Pulsion Medical Systems; Munich, Germany) may be useful dynamic variables in guiding fluid therapy in patients receiving mechanical ventilation. However, with respect to the prediction of volume responsiveness, conflicting results for SVV have been published in cardiac surgery patients. The goal of this study was to reevaluate SVV in predicting volume responsiveness and to compare it with PPV. DESIGN: Prospective nonrandomized clinical investigation. SETTING: University-based cardiac surgery. PATIENTS: Forty patients with preserved left ventricular function undergoing elective off-pump coronary artery bypass grafting. INTERVENTIONS: Volume replacement therapy before surgery. MEASUREMENTS AND RESULTS: Following induction of anesthesia, before and after volume replacement (6% hydroxyethyl starch solution, 10 mL/kg ideal body weight), hemodynamic measurements of stroke volume index (SVI), SVV, PPV, global end-diastolic volume index (GEDVI), central venous pressure (CVP) and pulmonary capillary wedge pressure (PCWP) were obtained. Also, left ventricular end-diastolic area index (LVEDAI) was assessed by transesophageal echocardiography. Prediction of ventricular performance was tested by calculating the area under the receiver operating characteristic (ROC) curves and by linear regression analysis; p < 0.05 was considered significant. All measured hemodynamic variables except heart rate changed significantly after fluid loading. GEDVI, CVP, PCWP, and LVEDAI increased, whereas SVV and PPV decreased. The best area under the ROC curve (AUC) was found for SVV (AUC = 0.823) and PPV (AUC = 0.808); the AUC for other preload indexes ranged from 0.493 to 0.636. A significant correlation with changes of SVI was observed for SVV (r = 0.606, p < 0.001) and PPV (r = 0.612, p < 0.001) only. SVV and PPV were closely related (r = 0.861, p < 0.001). CONCLUSIONS: In contrast to standard preload indexes, SVV and PPV, comparably, showed a good performance in predicting fluid responsiveness in patients before off-pump coronary artery bypass grafting.

Blood Pressure↗

Endoscope-assisted image-guided approach to the pituitary gland: preliminary cadaveric study.

The microscopic transsphenoidal approach to the pituitary gland is the current standard technique used by neurosurgeons to operate the pituitary gland. The endoscopic transsphenoidal approach to the pituitary gland is a current trend because more neurosurgeons are becoming familiar with the use of endoscopes. The use of associated image-guided surgery (or surgical navigation technology; these names are equivalent and are used interchangeably) allows a precise approach that increases the safety and efficacy of a surgical procedure. The InstaTrack system (GE Medical Systems Navigation and Visualization, Inc., Lawrence, MA) is a frameless electromagnetic navigational system used in this study. The objectives of this preliminary and conceptual cadaveric study (three heads) are to get familiarized with the use of image guidance and the study of the endoscopic anatomy of this region and to investigate the technical requirements and benefits of possible future shifting from microscopic towards endoscopic image guidance.

Cadaver↗

HIS-PACS coupling: BAZIS/ZIS and Philips/MARCOM on speaking terms.

Nowadays a growing number of experts in the PACS field agree on the necessity of having an integrated HIS-PACS combination available in modern hospitals in order to manage the enormous amounts of patient data, both textual, numerical and image information, in an effective way. Since 1986 BAZIS (the Development and Support Group of the Hospital Information System), Philips Medical Systems and the University Hospital of Utrecht (AZU) are partners in the so-called Dutch PACS Project in the development and evaluation of a fully integrated image information system. The first phase of the coupling (sub)project consists of establishing a communication link between the BAZIS/ZIS and the Philips/MARCOM system with the following restrictions: the only data sent concerns the inpatients of one ward; data will only flow one way, from BAZIS/ZIS to Philips/MARCOM. In the second phase two-way communication will be realized and more departments can be part of the experiment. In phase 3 a more general HIS-PACS interface will be developed, independent of the manufacturers of HIS and PACS. In this paper the technical solution chosen for the first phase coupling, the format of the messages being transferred, and the events which result in sending the messages, will be described. Also, reference is made to the demonstration of the working HIS-PACS link, given during the 6th EuroPACS meeting in Utrecht and Leiden on 25-26 April 1988.

Computer Communication Networks↗

MR imaging findings of clonorchiasis.

OBJECTIVE: The purpose of this study was to evaluate the MR spectrum and MR cholangiographic imaging findings of clonorchiasis. MATERIALS AND METHODS: We reviewed 26 patients with confirmed clonorchiasis by either stool tests (n=24) or surgery (n=2). MR imaging was performed on a 1.5 T system (GE Medical Systems, Milwaukee, WI) with a torso coil. Axial T1- and T2-weighted, gadolinium-enhanced dynamic images and MR cholangiography were obtained. Image analyses were used to identify abnormalities of the intrahepatic and extrahepatic bile ducts and the presence of hepatobiliary malignancy. All MR examinations were reviewed by the consensus of two abdominal radiologists. RESULTS: Intrahepatic bile duct abnormalities were seen in 23 (89%) of the 26 patients. The most common finding was mild dilatation of the intrahepatic bile duct which was found in 21 (81%). "Too many intrahepatic ducts" were found in 16(62%), wall enhancement and thickening in 21 (81%) and filling defects and ductal stricture in the intrahepatic bile duct in 6 (24%) and 3 (12%) patients, respectively. Extrahepatic ductal dilation was found in 5 (19%) and 9 (35%) revealed hepatobiliary malignancy. CONCLUSION: MR imaging revealed various findings of clonorchiasis, including dilatation, wall enhancement, stricture of the intrahepatic ducts and filling defect within the intrahepatic bile duct.

Adult↗

Early clinical experience with Orthofix external fixation of complex distal radius fractures.

Twelve patients with complex fractures of the distal radius were treated with the Orthofix external fixation system (EBI Medical Systems, Fairfield, NJ). On follow up physical examination, the average wrist dorsiflexion was 46 degrees, and the average volar flexion was 55 degrees. The average grip strength in the involved hand was 38 lb force. The average final radial angle was 18 degrees, and the average residual radial height was 12 mm. Average volar tilt was 3 degrees. The complication rate was 42%. Very rigid axial stability is afforded by the fixator, but the large 3.5 mm tapered bone screw diameter precludes redrilling for screw adjustment. The apparatus needs frequent monitoring to reconfirm the security of the locking nuts and cam mechanisms, and the Orthofix system can be reused only four times.

Adolescent↗

[Evaluation of the increase in signal intensity from applying the fast recovery technique to fast spin echo images].

The aim of the present study was to evaluate the increase in signal intensity caused by applying the fast recovery (FR) technique to fast spin echo (FSE) images, that is, the fast recovery fast spin echo (FR-FSE) method. All images of phantoms, whose T(2) values were different, were acquired with a Signa 1.5 Tesla system (GE Medical Systems) using the three-dimensional (3D) FSE and 3D FR-FSE sequences. We assessed the increased signal intensity as follows: (signal intensity on the FR-FSE image - FSE image) / FSE image (%). Our results showed that the increased signal intensity became high when 1) T(2) of the phantom was prolonged, 2) TR was shortened, and 3) echo train length (ETL) was decreased. By utilizing the results of this study, the increased signal caused by the FR technique could be estimated quantitatively when the TR, ETL, and T(2) of investigated substances were determined. For example, when TR, ETL, and T(2) were 1500 msec, 16-64, and 1500 msec, respectively, the increase in signal intensity was estimated to be approximately 70%. In addition, when T(2) was less than approximately 250 msec, signal intensity was not significantly increased by the FR pulses, that is, the FR-FSE image was the same as the FSE image. Accordingly, the FR-FSE method was confirmed to enhance the signal in substances with longer T(2), while maintaining the same contrast of the image as that obtained by the conventional FSE method. Our results are useful for evaluating the increased signal intensity caused by employing the FR technique.

Image Enhancement↗