A follow-up study of an uncemented knee replacement. The results of 312 knees using the Kodama-Yamamoto prosthesis.

The Kodama-Yamamoto knee is an uncemented surface replacement which has been used since 1970. The design has been improved twice and this present report concerns the results of the Mark II model. Between 1980 and 1984, 350 knees were replaced in 225 patients. In 1987, a survey of 335 of these knees was conducted at two to seven years after operation. The results were excellent or good in 83% of patients. Many of the failures were because of general disorders unrelated to the operation, but in 5.4% of the knees there were local complications which continue to present problems.

Arthritis, Rheumatoid↗

Results of knee replacement with the Walldius prosthesis: an interim report.

Fourty-two knees replaced with the Walldius prosthesis have been followed for an average of almost 6 years. The rating of the average knee on a 100 point clinical scale improved 29 points as a result of the procedure. Complications were carefully documented and were numerous, although relatively few affected the end result.

Arthritis↗

The biological reaction of the tissues to carbon fibre ligament prosthesis in sheep-knees.

The biological reaction of the tissues to carbon fibre ligament prosthesis was examined in sheep knees. Connective tissue and bone grew into the alloplastic ligament at the insertion points in cancellous bone. There was tissue ingrowth around the carbon fibres intra- and extra-articularly. The bony ingrowth into the ligament increases with time and there was no resorption present. The carbon fibre ligament should not be used as an internal splint in the fresh ligamentous repairs. The easiest method of ligament replacement in a chronically unstable knee is the application of alloplastic ligament material. Therefore the search for a good substitute has never been given up. Carbon fibres are found to be a very good scaffolding and a permanent prosthesis for ligament replacement [1, 2, 6, 8]. The biocompatibility of carbon fibres in animals has been proved [4, 6, 7]. The mechanical properties, tensile strength and flexibility, make the fibres suitable for use as ligament substitutes. The braiding of carbon fibre bundles has improved its biomechanical properties [3]. In this study the biological reaction of sheep-knees to carbon implants is investigated: 1. Does connective tissue grow into the ligament prosthesis under physiological conditions? 2. Is there tissue growth around the carbon ligaments intraarticularly? 3. Is a C-ligament useful as an internal splint in fresh ligamentous repairs? 4. What is the fate of the bone-ligament interface in long term use?

Animals↗

[Endoprostheses for one hip and both knee joints in a patient with rheumatoid arthritis after supracondylar fractures of both femurs].

The paper presents a case of hip prosthesis and ambilateral knee prosthesis after ambilateral supracondylar fractures of the femur healed in malposition in a patient with rheumatoid arthritis. The knee prosthesis were implanted without application of the femoral intramedullare rod. Three prosthesis were successfully implanted over a period of 8 weeks, obtaining pain relief and satisfactory range of movement.

Adult↗

Methods of combining the correction of deformities of the knee with the use of the total condylar prosthesis. Study of post-operative stability.

(1) Our Total Condylar knee prosthesis can be adapted to cases of severe deformity, either varus or valgus, and to flexion contracture. (2) The technique of mobilization and sliding of the capsulo-ligamentous structures on the contracted side is necessary in cases with severe deformity. (3) After mobilization of the contracted structures it is necessary, before sectioning the bone, to distract the joint in flexion as well as extension in order to achieve stability both in the sagittal and frontal planes. (4) Despite the removal of the cruciate ligaments and capsulo-ligamentous slide, no significant residual instability was found in either plane.

Aged↗

A comparison of primary and revision total knee arthroplasty using the kinematic stabilizer prosthesis.

The first 121 arthroplasties (in 105 patients) in which the cemented kinematic-stabilizer total knee prosthesis was used for primary arthroplasty or surgical revision at the Mayo Clinic were reviewed. Sixty-six patients (seventy-nine arthroplasties) were followed for a mean of thirty-seven months. There were fifty-three revision and twenty-six primary arthroplasties. The average range of motion in both groups increased from 95 to 101 degrees. Although none of these patients could ascend stairs without support before the operation, thirty-two (51 per cent) could do so at the time of the final follow-up. The incidence of moderate or severe pain was reduced from 86 to 6 per cent. Moderate or severe ligamentous instability had been present in thirty-three knees (42 per cent) preoperatively, but only five knees had significant medial, lateral, anterior, or posterior instability at final follow-up. The Hospital for Special Surgery knee score increased from an average of 56 points to 83 points in all of the knees. At follow-up, the patients who had had primary arthroplasty had 92 per cent good or excellent results and the patients who had had surgical revision had 81 per cent good or excellent results (p less than 0.05). There was no significant difference in the results between the patients who had osteoarthritis and those who had rheumatoid arthritis. Over-all, 85 per cent of the results were good or excellent at final follow-up. Tibial radiolucent lines of one to two millimeters were observed in 29 per cent of the knees at follow-up.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Failure of a cemented all-polyethylene patellar component of a Press-Fit Condylar Total Knee arthroplasty.

A 65-year-old woman had a posterior cruciate-retaining cemented Press-Fit Condylar (PFC; Johnson & Johnson Professional, Inc., Raynham, MA) knee replacement with resurfacing of the patella using a cemented all-polyethylene, 3-peg component. Five years postoperatively, the patient developed anterior knee pain. The patella tracked normally, but radiographs showed a shift of the patellar component. At revision, there was shear failure of all 3 fixation pegs and loosening of the component. Revision with a cemented Press-Fit Condylar Sigma patellar 3-peg component (Johnson & Johnson Professional, Inc., Raynham, MA) was performed.

Aged↗

Vancomycin-resistant Enterococcus infected total knee arthroplasty.

Use of vancomycin to treat infections and hospital colonization with methicillin-resistant Staphylococcus aureus has contributed to the development of vancomycin resistance in Enterococcus. Postoperative infection with vancomycin-resistant Enterococcus developed in 2 patients after total knee arthroplasty, indicating that the infections were nosocomial. Both patients required multiple procedures. The infections were controlled with serial open débridements. One knee was fused successfully, and the other was managed with resection arthroplasty.

Adult↗

Polyethylene-induced pes anserinus bursitis mimicking an infected total knee arthroplasty: a case report and review of the literature.

Polyethylene-induced pes anserinus bursitis after total knee arthroplasty (TKA) with the clinical manifestations mimicking an infected TKA is a very rare occurrence. We report such a case in a 74-year-old woman. She developed recurrent draining papules on the anterolateral aspect of the knee because of polyethylene-induced chronic pes anserinus bursitis 8 years after TKA. The diagnosis was established with a sinography study and confirmed by histopathologic examination of the surgical specimen. The symptoms were resolved after surgical excision of the lesion. Pes anserinus bursitis should be included in the differential diagnosis in knees with a draining sinus after TKA, and sinogram is considered the best method to establish the diagnosis.

Aged↗

Orthopaedic crossfire--All patellae should be resurfaced during primary total knee arthroplasty: in the affirmative.

Patients with inflammatory arthritis, crystalline deposition disease, or severe patellofemoral arthritis have superior functional results with patellar resurfacing as compared with patellar retention. The only remaining issue is whether there is any advantage to resurfacing or retention in patients with osteoarthritic knees in the absence of severe patellofemoral arthritis. Although the answer is still unclear from available prospective randomized clinical trials, the evidence leans toward routine resurfacing of the patella during primary total knee arthroplasty in osteoarthritic knees too. Evidence exists that the results of patellar retention in osteoarthritic knees deteriorate with longer follow-up study. Long-term follow-up evaluations of available prospective clinical trials will be needed to assess this controversy more definitively.

Arthroplasty, Replacement, Knee↗

Tibial post wear in posterior stabilized total knee arthroplasty. An unrecognized source of polyethylene debris.

BACKGROUND: With extensive use of posterior stabilized total knee arthroplasty implants, it is increasingly important to assess the mechanical performance of this design alternative. The purpose of this study was to examine the wear patterns at the femoral cam-tibial post interface in a series of posterior stabilized prostheses retrieved at revision arthroplasty. METHODS: Qualitative and quantitative wear analysis was performed over the surface of the stabilizing posts from twenty-three retrieved total knee components that had been implanted for a mean of 35.6 months (range, 2.3 to 107.2 months). The implants were designs from four different manufacturers. Digital images of the anterior, posterior, medial, and lateral surfaces of the tibial post were made for quantitative analysis and determination of a post wear score. Wear was characterized with a grading system that isolates adhesive, abrasive, and fatigue wear, inferring a weighted score from an estimation of generated polyethylene debris. RESULTS: Evidence of wear or damage was observed on all twenty-three of the stabilizing posts, including those revised because of infection. On the average, 39.9% (range, 18.5% to 60%) of the post surface demonstrated some form of deformation, with adhesive wear, or burnishing, being the predominant wear mechanism. Seven posts (30%) exhibited severe damage with gross loss of polyethylene. The wear caused premature failure and early revision of two components: one of these failures was related to isolated post wear and the other, to severe post wear and subsequent fracture. Overall, wear was primarily posterior, but wear over the anterior, medial, and lateral surfaces was also notable. CONCLUSIONS: The cam-post articulation in posterior stabilized implants can be an additional source of polyethylene wear debris. The variability in wear patterns observed among designs may be due to differences in cam-post mechanics, post location, and post geometry. The surgeon should be aware that the cam-post interface is not an innocuous articulation, and manufacturers should be motivated to produce implants that maintain the function of the post while limiting wear and surface damage.

Humans↗

[Bypass spanning the knee joint with synthetic prosthesis].

Synthetic tubes are the second choice for below-knee bypass materials. The ring-reinforced thin-walled Goretex-PTFE graft is an approved material which was tested in a multicenter study. The primary 3 years patency for below-knee femoral-popliteal bypass was 64%, for crural bypass 39%. A total of 195 grafts have been implanted. Long-term patency depends very much on the run-off conditions (81% in good and 43% in bad cases). The over-all limb salvage rate was 80% after 3 years.

Blood Vessel Prosthesis↗