Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Ink”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59Linked to original sources

Dip-pen nanolithography of reactive alkoxysilanes on glass.

The use of organofunctional silane chemistry is a flexible and general method for immobilizing biomolecules on silicon oxide surfaces, including fabricating DNA, small-molecule, and protein microarrays. The biggest hurdle in employing dip-pen nanolithography (DPN) for extending this general approach to the nanoscopic domain is the tendency of trialkoxy- and trichlorosilanes to rapidly polymerize due to hydrolysis reactions. The control of the local water concentration between the substrate surface and the scanning AFM tip is critical, both to the physical and chemical processes involved in DPN writing and to the ability to form well-defined thin layers of reactive silanes without extensive polymerization induced disorder. We found that we could control the degree of polymerization through careful choice of the alkoxysilane used as the "ink" for DPN and through control of the relative humidity during inking and writing with the coated AFM tip. As a proof-of-principle, we demonstrate that areas patterned with an alkoxysilane on glass with DPN are functional for subsequent immobilization of fluorescently labeled streptavidin via covalent attachment of biotin. This preliminary result sets the stage for the ability to capture proteins in their fully hydrated state from buffered solution, by molecular recognition onto previously written reactive nanoscopic regions on oxidized silicon and glass.

DNA↗

Chemically patterned flat stamps for microcontact printing.

Locally oxidized patterns on flat poly(dimethylsiloxane) stamps for microcontact printing were used as a platform for the transfer of a hydrophilic fluorescent ink to a glass substrate. The contrast was found to be limited. These locally oxidized patterns were conversely used as barriers for the transfer of hydrophobic n-octadecanethiol. In this case a good contrast was obtained, but the pattern was found to be susceptible to defects (cracks) in the barrier layer. Local stamp surface oxidation and subsequent modification with 1H,1H,2H,2H-perfluorodecyltrichlorosilane, for use as a barrier in the transfer of n-octadecanethiol, 16-mercaptohexadecanoic acid, and octanethiol, resulted in remarkably good contrast and stable patterns. The improved ink transfer control is ascribed to the reduction of undesired surface spreading and a superior mechanical stability of the stamp pattern. This new approach substantially expands the applicability of microcontact printing and provides a tool for the faithful reproduction of even extremely low filling ratio patterns.

Journal Article↗

Dynamic aspects of mercury porosimetry: a lattice model study.

Grand canonical Monte Carlo simulations using both Glauber dynamics and Kawasaki dynamics have been carried out for a recently developed lattice model of a nonwetting fluid confined in a porous material. The calculations are aimed at investigating the molecular scale mechanisms leading to mercury retention encountered during mercury porosimetry experiments. We first describe a set of simulations on slit and ink-bottle pores. We have studied the influence of the pore width parameter on the intrusion/extrusion curve shapes and investigated the corresponding mechanisms. Entrapment appears during Kawasaki dynamics simulations of extrusion performed on ink-bottle pores when the system is studied for short relaxation times. We then consider the more realistic and complex case of a Vycor glass building on recent work on the dynamics of adsorption of wetting fluids (Woo, H. J.; Monson, P. A. Phys. Rev. E 2003, 67, 041207). Our results suggest that mercury entrapment is caused by a decrease in the rate of mass transfer associated with the fragmentation of the liquid during extrusion.

Journal Article↗

Microcontact printing of proteins inside microstructures.

Microfluidic devices are well suited for the miniaturization of biological assays, in particular when only small volumes of samples and reagents are available, short time to results is desirable, and multiple analytes are to be detected. Microfluidic networks (MFNs), which fill by means of capillary forces, have already been used to detect important biological analytes with high sensitivity and in a combinatorial fashion. These MFNs were coated with Au, onto which a hydrophilic, protein-repellent monolayer of thiolated poly(ethyleneglycol) (HS-PEG) was self-assembled, and the binding sites for analytes were present on a poly(dimethylsiloxane) (PDMS) sealing cover. We report here a set of simple methods to extend previous work on MFNs by integrating binding sites for analytes inside the microstructures of MFNs using microcontact printing (muCP). First, fluorescently labeled antibodies (Abs) were microcontact-printed from stamps onto planar model surfaces such as glass, Si, Si/SiO2, Au, and Au derivatized with HS-PEG to investigate how much candidate materials for MFNs would quench the fluorescence of printed, labeled Abs. Au coated with HS-PEG led to a fluorescence signal that was approximately 65% weaker than that of glass but provided a convenient surface for printing Abs and for rendering the microstructures of the MFNs wettable. Then, proteins were inked from solution onto the surface of PDMS (Sylgard 184) stamps having continuous or discontinuous micropatterns or locally inked onto planar stamps to investigate how the aspect ratio (depth:width) of microstructures and the printing conditions affected the transfer of protein and the accuracy of the resulting patterns. By applying a controlled pressure to the back of the stamp, Abs were accurately microcontact-printed into the recessed regions of MFNs if the aspect ratio of the MFN microstructures was lower than approximately 1:6. Finally, the realization of a simple assay between Abs (used as antigens) microcontact-printed in microchannels and Abs from solution suggests that this method could become useful to pattern proteins in microstructures for advanced bioanalytical purposes.

Antibodies↗

Microscale plasma-initiated patterning (muPIP).

A novel technique to create biomolecular micropatterns of varying complexity on several types of polymer substrates is presented. This method uses a patterned PDMS stamp to preferentially expose or protect areas of an underlying polymer substrate from oxygen plasma. Following plasma treatment, the substrate is immersed in a biomolecular ink, whereby molecules preferentially adsorb to either the plasma-exposed or plasma-protected substrate regions, depending on the particular substrate/ink combination. Using this method, polyethylene (PE), polystyrene (PS), poly(methyl methacrylate) (PMMA), poly(dimethylsiloxane) (PDMS), and poly(hydroxybutyrate/hydroxyvalerate) (PHBV) were micropatterned with different aqueous-based biomolecular inks (i.e., goat anti-rabbit immunoglobulin G, poly-l-lysine, and bovine serum albumin (BSA)). Water contact angle measurements performed on substrates after oxygen plasma exposure showed that the hydrophilicity of substrate areas exposed to plasma was significantly greater than that of areas protected from plasma by the PDMS stamp. In addition, scanning electron microscopy results demonstrated that substrate areas exposed to plasma were physically modified (e.g., roughened) compared to adjacent, protected areas. Areas in contact with a patterned PDMS stamp during plasma exposure were found to be physically unaffected by plasma treatment, and exhibited spatial features/dimensions consistent with the corresponding features of the patterned stamp. Last, protein patterns of BSA on the polymer substrates were stable and distinct after 4 weeks of incubation at 37 degrees C.

Microscopy, Electron, Scanning↗

Nanoliter-scale reactor arrays for biochemical sensing.

A general approach is described for array-based biochemical sensing that uses contact-free dispersal of compounds into addressable microfabricated reactors. The arrays are composed of 1 to 100 nL volume open reactors that have been microfabricated on quartz substrates using lithography. The open architecture of these reactors allows them to be addressed in parallel or individually with an ink-jet arrayer that is capable of distributing 0.004 to 1 nL volumes of reagents. A seven-step biochemical assay has been conducted on a small array of reactors to demonstrate how they can be integrated with an ink-jet arrayer and optical detector. This nanoreactor assay format appears to overcome several limitations that chip-based microarray technology currently imposes on protein assays: the arrays can be created in a manner that does not expose the biochemical reagents to osmotic stress, independent reactions can be conducted in individual reactors, and the conditions in all of the reactors (e.g., concentration and pH) can be rapidly scanned. We believe that these nanoreactor arrays will be useful for biochemical sensing that involves delicate proteins and protein assemblies.

Biosensing Techniques↗

Preparation of high catalyst utilization electrodes for polymer electrolyte fuel cells.

We have developed a novel preparation procedure for an electrocatalyst layer with high utilization of catalyst for polymer electrolyte fuel cells. A commercial Pt catalyst supported on high surface area carbon black (Pt/CB) and Nafion ionomer solution was heated in an autoclave at 200 degrees C, followed by quenching to form the ink of the mixture. It was found that the cathode prepared with the new catalyst ink exhibited very high performance, i.e., high catalyst utilization and improved gas diffusivity. The microstructure analysis indicated that the autoclave treatment promoted an effective introduction of Nafion ionomer into primary pores of Pt/CB agglomerates, in which ca. 90% of Pt catalysts were supported. It was clearly observed by scanning transmission electron microscopy that Nafion ionomer was distributed more uniformly inside Pt/CB agglomerates, compared with those simply mixed with a ball mill in a conventional manner.

Journal Article↗

Intestinal microvascular patterns during hemorrhagic shock.

While injuries due to a hypoxic state commonly appear later in both intestinal crypts and basal portion of the villi than in the apical portion, a nonhomogeneous distribution of blood flow in the intestinal mucosa may be supposed. The presence of two different microvascular plexuses inside the mucosa, corresponding to the cryptal plexus and the villous plexus, supports the above hypothesis. This work studies the intestinal microvasculature in shocked versus normal rats. Forty-five rats were divided into four groups to study the histological damage and the microvascular bed by ink injection, fluorescent microsphere infusion, and resin injection for scanning electron microscopy (SEM) of vascular corrosion cast (VCC) observations. An infusion pressure of 100 +/- 5 mm Hg was used in control animals, while 30 +/- 5 mm Hg infusion pressure was adopted for controls as well as for shocked animals to simulate physiological or shock conditions. Hemorrhagic shock was induced by removing blood and maintaining a mean arterial pressure of 30 +/- 5 mm Hg for 45-120 mins. A close connection among the patterns of microvasculature obtained with VCC and ink injection technique can be appreciated. In normal rats the whole microvasculature was visualized, but in both normal and shocked animals injected at low pressure different patterns could be found, generally showing a highly incomplete visualization of the vascular network. A significant decrease of visualization of both the entire microvasculature and the villous plexus is present in shocked animals when compared to unshocked controls, while no difference in the cryptal plexus visualization was observed. These observations suggest that the cryptal plexus is perfused preferentially during hemorrhagic shock, as a consequence of its peculiar microvascular organization. This may explain the relative resistance of the crypts, compared to villi, to hypoxic injuries in order to sustain endocrine function and the regenerative capability of the mucosa after prolonged hypoperfusion conditions that can lead to villous damage and temporary loss of the intestinal barrier function.

Animals↗

Solvent exchange method: a novel microencapsulation technique using dual microdispensers.

PURPOSE: A new microencapsulation method called the "solvent exchange method" was developed using a dual microdispenser system. The objective of this research is to demonstrate the new method and understand how the microcapsule size is controlled by different instrumental parameters. METHOD: The solvent exchange method was carried out using a dual microdispenser system consisting of two ink-jet nozzles. Reservoir-type microcapsules were generated by collision of microdrops of an aqueous and a polymer solution and subsequent formation of polymer films at the interface between the two solutions. The prepared microcapsules were characterized by microscopic methods. RESULTS: The ink-jet nozzles produced drops of different sizes with high accuracy according to orifice size of a nozzle, flow rate of the jetted solutions, and forcing frequency of the piezoelectric transducers. In an individual microcapsule, an aqueous core was surrounded by a thin polymer membrane; thus, the size of the collected microcapsules was equivalent to that of single drops. CONCLUSIONS: The solvent exchange method based on a dual microdispenser system produces reservoir-type microcapsules in a homogeneous and predictable manner. Given the unique geometry of the microcapsules and mildness of the encapsulation process, this method is expected to provide a useful alternative to existing techniques in protein microencapsulation.

Capsules↗

A horse race of a different color: Stroop interference patterns with transformed words.

Four experiments investigated Stroop interference using geometrically transformed words. Over experiments, reading was made increasingly difficult by manipulating orientation uncertainty and the number of noncolor words. As a consequence, time to read color words aloud increased dramatically. Yet, even when reading a color word was considerably slower than naming the color of ink in which the word was printed, Stroop interference persisted virtually unaltered. This result is incompatible with the simple horse race model widely used to explain color-word interference. When reading became extremely slow, a reversed Stroop effect--interference in reading the word due to an incongruent ink color--appeared for one transformation together with the standard Stroop interference. Whether or not the concept of automaticity is invoked, relative speed of processing the word versus the color does not provide an adequate overall explanation of the Stroop phenomenon.

Attention↗

Effects of S-R mapping and response modality on performance in a Stroop Task.

Forty subjects performed a choice reaction time task in which the stimulus was the word Red or Green printed in either red or green ink. Subjects responded verbally in one block of trials and by key pressing in another block. For one group, ink color was the relevant cue, and for another group, the word was the relevant cue. Half of the subjects in each group were instructed to make the response that corresponded to the relevant cue (compatible S-R [stimulus-response] mapping); the other half were instructed to make the response that did not correspond (incompatible S-R mapping). In general, subjects who performed under compatible S-R mapping instructions reacted faster when the irrelevant cue corresponded to the response than when it did not. In contrast, subjects show performed under incompatible S-R mapping instructions reacted faster when there was a lack of correspondence between the irrelevant cue and the response than when there was correspondence. Results were consistent with a notion of logical recoding; that is, that instructing subjects to recode the relevant cue into the alternate color may have caused them to recode the irrelevant cue in the same logical manner. Results might also be interpreted to suggest that the Stroop effect is related to congruence between the relevant and the irrelevant cues rather than to correspondence between the irrelevant cue and the response.

Color Perception↗

Response-specific inhibition during general facilitation of defensive responses in Aplysia.

Siphon responses of Aplysia have been used to examine the neural basis of nociceptive behavioral inhibition. The authors tested the response specificity and functional significance of this inhibition. Video analysis showed that strong tail-nerve shock decreased the duration of siphon constriction evoked by weak siphon shock. Tail-nerve shock also caused the appearance of a novel flaring response to the test stimulus, which resembled the siphon response to tail-nerve shock. Novel flaring responses were expressed to both mechanical and electrical siphon stimuli. Tailshock facilitated another defensive response, inking, during the period of inhibited siphon constriction. Tailshock also facilitated tail contractions evoked by weak contralateral tail stimulation during this period. These results indicate that inhibition is not generalized across defensive responses and is specific to siphon responses that interfere with directed ink ejection toward an injured site.

Animals↗

Visual cues and the handwriting of older adults: a kinematic analysis.

Kinematic techniques determined the nature of any age-related changes in the fluency of handwriting movements and also the extent to which any changes can be related to a differential utilization of visual feedback. To quantitatively document the kinematics of handwriting movements, 24 young and 24 older adults were compared by having them write simple cursive letter ls 4 times on a graphics tablet, under 4 different visual conditions (no vision, non inking pen, inking pen, and lined paper). Pen tip position was sampled at 200 Hz, from which kinematic indexes of movement efficiency and consistency were derived. Quantitative differences in movement trajectories were found in the older adults, who produced less efficient movements with a concomitant increased utilization of external visual cues. Older adults made a differential use of visual feedback to modify movement trajectories, rather than to control the effects of neural noise. Handwriting movements of older adults resembled only to a limited extent those of patients with Parkinson's disease.

Adult↗

Rapid prototyping of patterned functional nanostructures

Living systems exhibit form and function on multiple length scales and at multiple locations. In order to mimic such natural structures, it is necessary to develop efficient strategies for assembling hierarchical materials. Conventional photolithography, although ubiquitous in the fabrication of microelectronics and microelectromechanical systems, is impractical for defining feature sizes below 0.1 micrometres and poorly suited to pattern chemical functionality. Recently, so-called 'soft' lithographic approaches have been combined with surfactant and particulate templating procedures to create materials with multiple levels of structural order. But the materials thus formed have been limited primarily to oxides with no specific functionality, and the associated processing times have ranged from hours to days. Here, using a self-assembling 'ink' we combine silica-surfactant self-assembly with three rapid printing procedures--pen lithography, ink-jet printing, and dip-coating of patterned self-assembled monolayers--to form functional, hierarchically organized structures in seconds. The rapid-prototyping procedures we describe are simple, employ readily available equipment, and provide a link between computer-aided design and self-assembled nanostructures. We expect that the ability to form arbitrary functional designs on arbitrary surfaces will be of practical importance for directly writing sensor arrays and fluidic or photonic systems.

Journal Article↗

Microperiodic structures: direct writing of three-dimensional webs.

Applications are emerging that require the creation of fine-scale structures in three dimensions--examples include scaffolds for tissue engineering, micro-fluidic devices and photonic materials that control light propagation over a range of frequencies. But writing methods such as dip-pen nanolithography and ink-jet printing are either confined to two dimensions or beset by wetting and spreading problems. Here we use concentrated polyelectrolyte inks to write three-dimensional microperiodic structures directly without using masks. Our technique enables us to write arbitrary three-dimensional patterns whose features are nearly two orders of magnitude smaller than those attained with other multilayer printing techniques.

Journal Article↗

Histological margin assessment for breast ductal carcinoma in situ: precision and implications.

Local recurrence after lumpectomy for ductal carcinoma in situ (DCIS) is a major concern and is related to residual disease in the breast. We studied the predictive value of lumpectomy margins for residual DCIS and compared our results and pathological processing techniques with those published in the literature. Margin status was determined for 89 patients with screen-detected DCIS who had lumpectomy and re-excision, for the presence and extent of residual disease. Margin width was defined as the narrowest distance between tumor and any inked margin or, where margins were positive, classified into focal involvement (<1 mm of the inked surface involved), minimal (>or=1<15 mm) and extensive (>or=15 mm). The amount of residual tumor was quantified according to the number of ducts involved with tumor: small (fewer than 10 ducts) or large (10 or more ducts) residuum. The initial margin status was a significant predictor for the presence of residual tumor in re-excision specimens (P=0.006). There was residual tumor in 44 and 45% of close non-involved (>1 and 25 mm,respectively, showing residual disease. The presence of residual tumor was not significantly related to age, mammographic appearance, nuclear grade or intraductal necrosis. The initial margin status was found to predict for the amount of residual tumor. With careful margin assessment, margin status after lumpectomy for DCIS can be used to predict for the presence and amount of residual tumor in the breast and is a guide to further management decisions. A standard for margin status reporting and pathological processing of screen-detected DCIS in situ lesions will help in the interpretation of data from different institutions.

Adult↗

Adult endothelial progenitor cells from human peripheral blood maintain monocyte/macrophage function throughout in vitro culture.

Mononuclear cells (MNCs) isolated from peripheral blood by density gradient centrifugation were plated on human fibronectin-coated culture plates and cultured in EGM-2 medium. Attached spindle-shaped cells, reported as endothelial progenitor cells (EPCs) by some investigators, had elongated from adherent round cells, but had not proliferated from a small number of cells as supposed previously. The growth curve of the primary EPCs showed that the cells had little proliferative capacity. Flow cytometry analysis showed that the cells could express some of the endothelial lineage markers, while they could also express CD14, which is considered a marker of monocyte/macrophage lineages throughout culture. In endothelial function assays, the cells demonstrated a lower level of expression of eNOS than mature endothelial cells in the reverse transcription-polymerase chain reaction and did not show an ability to develop tube-like structures in angiogenesis assay in vitro. In this study, we identified the monocytoid function of EPCs by the combined Dil-labeled acetylated low-density lipoprotein (Dil-Ac-LDL) and Indian ink uptake tests. All the cells were double positive for Dil-Ac-LDL and Indian ink uptake at days 4, 14 and 28 of culture, which means the EPCs maintained monocytoid function throughout the culture. Therefore, although adult EPCs from peripheral MNCs have some endothelial lineage properties, they maintain typical monocytic function and have little proliferative capacity.

Adult↗

The evaluation of a low resolution fourier transform infrared (FTIR) gas analyser for monitoring of solvent emission rates under field conditions.

The applicability of a low resolution (8 cm-1) Fourier transform infrared (FTIR) gas analyser with an absorption path length of 3 m was evaluated for the on-line monitoring of organic solvent mixture emissions in a flexographic ink manufacturing plant. The on-line monitoring revealed that the highest variations of solvent concentrations, up to three decades, occurred in the exhaust air. The FTIR analyser with a dynamic range of four decades covers well the concentration ranges typically found in the exhaust air and in the workroom air of ink manufacturing plants. The average emission rate of solvent mixture based on a sampling period of two days was 1.8 kg h-1 consisting of mainly ethanol (70%), ethyl acetate (15%) and propan-2-ol (11%). The detection limits of the analyser for the solvent compounds ranged from 0.3 to 4.3 mg m-3 and the measurement uncertainty was less than 10% in the concentration range of 8-15,000 mg m-3. These characteristics make the apparatus appropriate for most industrial hygiene applications. An FTIR spectrophotometer, equipped with an multipoint sampling unit, facilitates rapid identification of solvent components, real-time display of concentration data relevant to workroom air and environment monitoring as well as process control. Furthermore, the on-line concentration information enabled a rapid selection of representative sampling locations. The spectrophotometer is transportable, rugged and relatively simple to calibrate even in a hostile industrial environment.

Coloring Agents↗