Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Inhalation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59Linked to original sources

Effect of inhaled furosemide and torasemide on bronchial response to ultrasonically nebulized distilled water in asthmatic subjects.

Inhaled furosemide has been shown to reduce the bronchoconstriction induced by several indirect stimuli, including ultrasonically nebulized distilled water (UNDW). Because the protective effect could be due to the inhibition of the Na(+)-2Cl(-)-K+ cotransport system of bronchial epithelium, we have compared the protective effect of inhaled furosemide with that of inhaled torasemide, a new and more potent loop diuretic, on UNDW-induced bronchoconstriction in a group of 12 asthmatic subjects. UNDW challenge was performed by constructing a stimulus-response curve with five increasing volume outputs of distilled water (from 0.5 to 5.2 ml/min) and the bronchial response expressed as the provocative output causing a 20% fall in FEV1 (PO20UNDW). On different days, each subject inhaled an equal dose (28 mg) of furosemide and torasemide in a randomized, double-blind, placebo-controlled study 5 min prior to an UNDW challenge. Furosemide and torasemide had no significant effect on resting lung function. The geometric mean value of PO20UNDW measured after placebo was 1.73 ml/min. This was significantly lower than that recorded after furosemide (4.25 ml/min; p < 0.025), but not after torasemide (3.05 ml/min; p = 0.07). Inhaled furosemide totally blocked bronchial response to UNDW in five subjects. In two of five subjects the response was also blocked by inhaled torasemide. A remarkable increase in diuresis was noted only after torasemide in most subjects. We conclude that inhaled furosemide has a better protective effect than does inhaled torasemide against UNDW-induced bronchoconstriction. However, the protective effect of furosemide is variable, with some asthmatic patients showing no change in bronchial response to UNDW.(ABSTRACT TRUNCATED AT 250 WORDS)

Administration, Inhalation↗

Inhaled corticosteroids in chronic obstructive pulmonary disease and risk of death and hospitalization: time-dependent analysis.

Observational studies of inhaled corticosteroids in chronic obstructive pulmonary disease (COPD) have shown improved survival whereas randomized trials have not. It has been suggested that this difference may be due to immortal time bias. To investigate this further, we performed a prospective cohort study of patients with COPD, using time-dependent methods to determine whether use of inhaled corticosteroids more than 80% of the time reduced the risk of all-cause mortality and COPD exacerbations. Of 8,033 patients, 2,686 (33%) received inhaled corticosteroids. We did not find a significant reduction in mortality for average inhaled steroid use at either low (hazard ratio [HR], 0.96; 95% confidence interval [CI], 0.69-1.33) or medium/high dose (HR, 0.86; 95% CI, 0.67-1.10). Similarly, recent inhaled corticosteroid use was not associated with a reduction in mortality at low (HR, 0.80; 95% CI, 0.60-1.07) or medium/high doses (HR, 0.88; 95% CI, 0.71-1.09). There was no association between inhaled corticosteroid use and hospitalizations or exacerbations due to COPD. Patients using medium/high-dose inhaled corticosteroids did not have a significantly lower risk of COPD hospitalizations (HR, 0.85; 95% CI, 0.64-1.13) or COPD exacerbations (HR, 1.13; 95% CI, 0.94-1.36). In a time-dependent study of outpatients with COPD, adherence to inhaled corticosteroid use was not associated with a decreased risk of mortality or exacerbations.

Administration, Inhalation↗

Inhaled Rho kinase inhibitors are potent and selective vasodilators in rat pulmonary hypertension.

We have found in chronically hypoxic rats that acute intravenous administration of the Rho kinase inhibitor Y-27632 nearly normalizes the pulmonary hypertension (PH) but has no pulmonary vascular selectivity. In this study, we tested if oral or inhaled Y-27632 would be an effective and selective pulmonary vasodilator in hypoxic PH. Although acute oral Y-27632 caused a marked and sustained decrease in mean pulmonary arterial pressure (MPAP), it also decreased mean systemic arterial pressure (MSAP). In contrast, 5 minutes of inhaled Y-27632 decreased MPAP without reducing MSAP. The hypotensive effect of inhaled Y-27632 on hypoxic PH was greater than that of inhaled nitric oxide, and the effect lasted for at least 5 hours. Inhaled fasudil, another Rho kinase inhibitor, caused selective MPAP reductions in monocrotaline-induced PH and in spontaneous PH in fawn-hooded rats, as well as in chronically hypoxic rats. These results suggested that inhaled Y-27632 was more effective than inhaled nitric oxide as a selective pulmonary vasodilator in hypoxic PH, and that Rho kinase-mediated vasoconstriction was also involved in the other models of PH. Inhaled Rho kinase inhibitors might be useful for acute vasodilator testing in patients with PH, and future work should evaluate their efficacy in the long-term treatment of PH.

1-(5-Isoquinolinesulfonyl)-2-Methylpiperazine↗

Dose-response characteristics during long-term inhalation of nitric oxide in patients with severe acute respiratory distress syndrome: a prospective, randomized, controlled study.

Inhaled nitric oxide (NO) improves systemic oxygenation (PaO2/FIO2) in adult patients with acute respiratory distress syndrome (ARDS). However, individual response varies, and previous trials demonstrated no outcome benefit. This prospective, randomized study in 40 ARDS patients analyzed dose-response (DR) characteristics during long-term inhaled NO. Patients were randomized for conventional therapy (control) or continuous treatment with 10 parts per million (ppm) inhaled NO until weaning was initiated. We measured DR curves of PaO2/FIO2 versus the inhaled NO dose at regular intervals. Before treatment (Day 0), peak improvement in PaO2/FIO2 was achieved at 10 ppm for both control and NO-treated patients. After 4 days, the DR curve of the NO-treated patients was left shifted with a peak response at 1 ppm. At higher doses (10 and 100 ppm), oxygenation deteriorated, and the response to inhaled NO disappeared in several patients. This effect was not observed in the control group. There was no effect of inhaled NO on duration of mechanical ventilation or stay at the intensive care unit. In conclusion, long-term inhaled NO with constant doses of 10 ppm leads to enhanced sensitivity after several days and does do not allow reduction of ventilation parameters. Hence, previous trials on therapy with inhaled NO in ARDS should be carefully interpreted, as they used constant NO concentrations, which may have become overdoses leading to deterioration of oxygenation after several days.

Acute Disease↗

Can a low or moderate dose of inhaled budesonide replace oral non-steroidal anti-asthma treatment?

The efficacy of inhaled budesonide was assessed as an adjunct to and as a replacement for oral bronchodilators in an open study of 27 asthmatic patients. The patients had been treated regularly with oral bronchodilators but not with oral inhaled, or nasal steroids during the 2 3 months prior to the study. The study consisted of four treatment periods: 1, oral bronchodilator plus inhaled placebo for 1 week; 2, oral bronchodilator plus 400 micrograms inhaled budesonide twice daily for 3 weeks; 3,400 micrograms inhaled budesonide twice daily for 3 weeks; 4,200 micrograms inhaled budesonide twice daily for 3 weeks. Lung function measurements increased when budesonide was included with oral bronchodilators and there was a corresponding decrease in symptoms and rescue inhaler usage. Removal of oral bronchodilators from therapy did not significantly alter lung function and symptoms, whereas decreasing the dose of budesonide produced a slight reduction in peak expiratory flow and an increase in inhaled bronchodilator consumption.

Administration, Inhalation↗

Effect of inhaled heparin on lung function and coagulation in healthy volunteers.

The aim of the present study was to investigate the safety of increasing doses of a well-defined lower respiratory tract (LRT) dose of inhaled heparin with regard to pulmonary function and coagulation. Ten volunteers inhaled heparin from Sidestream jet nebulizers loaded with 100,000, 200,000, 300,000 or 400,000 International Units (IU) of heparin. Lung function, antifactor (anti)-Xa, activated partial thromboplastin time (APTT), tissue factor pathway inhibitor (TFPI), whole blood clotting time, platelets, von Willebrand factor, and C-reactive protein were determined before and 1, 3, 6, and 24 h after inhalation. The highest LRT dose was 32,000 IU heparin. Inhaled heparin did not affect pulmonary function. The area under the curve of the anti-Xa activity increased with increasing doses of heparin (p=0.005), but remained unchanged for all other variables. Peak anti-Xa activity was 0.113 IU x mL(-1) 6 h after inhalation of 400,000 IU heparin. When compared to baseline values: anti-Xa increased after 200,000 (p=0.03), 300,000 (p=0.004), and 400,000 IU (p=0.002) heparin; APTT increased to a maximum of 1.03 6 h after inhalation of 400,000 IU heparin (p=0.05); TFPI increased after 100,000 (p=0.01), 200,000 (p=0.01), 300,000 (p=0.006) and 400,000 IU (p<0.001). Inhaled heparin delivery of 32,000 International Units to the lower respiratory tract can safely be inhaled for clinical or research purposes.

Administration, Inhalation↗

Misuse of corticosteroid metered-dose inhaler is associated with decreased asthma stability.

This study assessed whether the improper use of pressurized metered-dose inhalers (pMDIs) is associated with decreased asthma control in asthmatics treated by inhaled corticosteroids (ICS). General practitioners (GPs) included consecutive asthmatic outpatients treated by pMDI-administered ICS and on-demand, short-acting beta2-agonists. They measured an asthma instability score (AIS) based on daytime and nocturnal symptoms, exercise-induced dyspnoea, beta2-agonist usage, emergency-care visits and global perception of asthma control within the preceding month; the inhalation technique of the patient also was assessed. GPs (n=915) included 4,078 adult asthmatics; 3,955 questionnaires were evaluable. pMDI was misused by 71% of patients, of which 47% was due to poor coordination. Asthma was less stable in pMDI misusers than in good users (AIS: 3.93 versus 2.86, p<0.001). Among misusers, asthma was less stable in poor coordinators (AIS: 4.38 versus 3.56 in good coordinators, p<0.001). To conclude, misuse of pressurized metered-dose inhalers, which is mainly due to poor coordination, is frequent and associated with poorer asthma control in inhaled corticosteroid-treated asthmatics. This study highlights the importance of evaluating inhalation technique and providing appropriate education in all patients, especially before increasing inhaled corticosteroid dosage or adding other agents. The use of devices which alleviate coordination problems should be reinforced in pressurized metered-dose inhaler misusers.

Administration, Inhalation↗

A cyclosporin A/maltosyl-alpha-cyclodextrin complex for inhalation therapy of asthma.

The inhalation of cyclosporin (Cs)A to the lung is limited by its hydrophobic properties. In order to improve the poor solubility of CsA, cyclodextrin (CD) was evaluated for its suitability for dry powder inhaler formation, and the benefit of an inhaled CsA/CD complex in vivo was demonstrated. The solubilising effect of CDs on CsA was measured by high-performance liquid chromatography. Ciliostatic activity and haemolysis were determined to assess some safety profiles of CDs. The efficacy of an inhaled CsA/CD complex was evaluated by eosinophil infiltration into the bronchoalveolar lavage fluid in actively sensitised mice. CDs markedly improved the poor solubility of CsA. The ciliostatic and haemolytic activities of maltosyl-alpha-CD were the weakest of all the tested CDs. CsA inhaled alone showed inhibitory effects on allergen-induced eosinophilia. Inhalation of the complex of CsA with maltosyl-alpha-CD, where the dose of CsA was approximately nine-times less than that of CsA inhaled alone, also inhibited eosinophil accumulation significantly, with a longer duration of action in comparison with the response to CsA alone. Thus the effective dose of cyclosporin A could be reduced by formation of a complex with maltosyl-alpha-cyclodextrin, and a wider therapeutic safety margin by inhalation of cyclosporin A as a complex with maltosyl-alpha-cyclodextrin could be expected.

Administration, Inhalation↗

Patient compliance with inhaled medication: does combining beta-agonists with corticosteroids improve compliance?

Patient compliance with an inhaled corticosteroid may be greater if it is combined with a beta-agonist. This study compared compliance with an inhaled corticosteroid (budesonide), and a short-acting inhaled beta-agonist (terbutaline sulphate), and a Turbuhaler inhaler containing a combination of the two drugs. In an open, multicentre, parallel group study 102 asthmatic patients were randomly divided into two groups, either receiving the two drugs in separate Turbuhalers or combined into one Turbuhaler. A twice daily regimen was prescribed and a preweighed metered-dose inhaler (MDI) of salbutamol was provided for rescue use. Compliance was measured using the Turbuhaler Inhalation Computer (TIC), which recorded the time and date of each inhalation over a 12 week period. Forced expiratory volume in one second (FEV1) and forced vital capacity (FVC) measurements were carried out at week 0, 6 and 12. Results from 72 patients were analysed. The average compliance was 60-70%. Treatment was taken as prescribed on 30-40% of the study days, and over-usage occurred on less than 10% of days. Only 15% of patients took the drugs as prescribed for more than 80% of the days. Compliance was no greater in patients using the combined inhalers. Other ways of improving patient self-management need further investigation.

Administration, Inhalation↗

Effects of inhaled nitric oxide on methacholine-induced bronchoconstriction: a concentration response study in rabbits.

Inhaled nitric oxide (NO), at a concentration of 80 ppm, counters the increase in respiratory resistance (Rrs) induced by methacholine, but fails to prevent a reduction in lung compliance (Crs) in a rabbit model. This study reports the effects of 3, 30 and 300 ppm of inhaled NO. New Zealand White rabbits were intubated and mechanically ventilated with 30% oxygen during neurolept anaesthesia. Methacholine (3 mg.ml-1) was nebulized, with or without NO inhalation. Inhalation of 3 and 30 ppm NO had no effect on the induced bronchoconstriction, whereas 300 ppm fully blocked the increase in Rrs. The decrease in Crs due to methacholine was not countered by 3, 30 or 300 ppm NO. On the contrary, inhalation of 300 ppm NO in itself decreased Crs from 5.0 +/- 0.1 to 4.3 +/- 0.1 ml.cmH2O-1. Also, mean arterial pressure (60 +/- 7 to 54 +/- 5 mmHg), alveolar-arterial oxygen tension gradient (0.8 +/- 0.8 to 2.3 +/- 1.8 kPa) and methaemoglobin (0.5 +/- 0.2 to 1.5 +/- 0.5%) changed significantly on inhalation of NO 300 ppm prior to methacholine challenge. We conclude that 3 and 30 ppm NO inhalation does not alter methacholine-induced bronchoconstriction. Inhalation of 300 ppm NO blocks an increase in resistance but fails to counter the reduction in compliance due to methacholine. This suggests that the bronchodilating effects of NO in rabbits in vitro are confined to the large airways.

Administration, Inhalation↗

Deposition and clearance of inhaled 18FDG powder in patients with chronic obstructive pulmonary disease.

As freon is limited in its use as a generator for aerosol inhalation, powder particles are used as an alternative for inhalation therapy. The pulmonary deposition and clearance of inhaled powder particles was studied by positron emission tomography (PET) in ten patients with chronic obstructive pulmonary disease (COPD) and in five normal controls. The powder, 5 microm in mean diameter, was water soluble and labelled with 2-deoxy-2-[18F]-fluoro-D-glucose (18FDG). Powder inhalation was done with single deep inspiration from residual volume to total lung capacity. The initial deposition ratio in the right or left lung field to total inhaled dose, measured by an anteroposterior rectilinear scan, did not differ between normals and COPD patients. Ratios of radioactivity detected within the central and peripheral regions (the central to peripheral ratio) measured by the PET scan was not significantly different between COPD patients (4.8+/-2.6, mean+/-SD) and normals (2.6+/-0.8, mean+/-SD). However, the regional powder deposition in peripheral lung fields measured by the PET scan was significantly more uneven in COPD patients than in normal patients. The clearance rate of 18FDG, defined as the retention ratio of 18FDG activity to the initially deposited 18FDG at 60 and 120 min after inhalation, in the trachea, large bronchi or peripheral lung fields measured by tomographic scan showed a wider variation in COPD patients than in normals. To conclude, inhaled powder tended to be deposited more centrally and was distributed more unevenly in the peripheral lung in chronic obstructive pulmonary disease patients than in normals. This could be a limitation of powder inhalation used for therapy in chronic obstructive pulmonary disease patients.

Administration, Inhalation↗

An inhaled steroid improves markers of airway inflammation in patients with mild asthma.

Airway inflammation can be demonstrated in mildly asthmatic patients who are not treated with inhaled steroids. Current guidelines recommend that inhaled steroids should be introduced in mild asthmatics who use an inhaled beta2-agonist more than once daily. It was postulated that inhaled steroids can have anti-inflammatory effects in patients with even milder disease. The effect of 4 weeks of treatment with budesonide (800 microg twice daily by Turbohaler) was studied in 10 steroid-naive mildly asthmatic patients (forced expiratory volume in one second (FEV1) = 96+/-1.4% predicted) who required an inhaled beta2-agonist less than one puff daily, in a double-blind, placebo-controlled, crossover fashion. Spirometry, exhaled nitric oxide (NO), bronchial responsiveness (provocative concentration causing a 20% fall in FEV1 (PC20)), and sputum induction were performed before and after each treatment period. Following budesonide treatment, there were significant improvements in FEV1, and PC20, in association with a significant reduction in the percentage of eosinophils in induced sputum. Exhaled NO levels tended towards reduction, but the change was nonsignificant. There were also nonsignificant reductions in sputum eosinophil cationic protein and tumour necrosis factor-alpha levels. In conclusion inhaled budesonide can lead to improvements in noninvasive markers of airway inflammation, in association with a small improvement in lung function, even in mildly asthmatic patients who require an inhaled beta2-agonist less than once daily. This suggests a potential benefit of inhaled corticosteroids, even in relatively asymptomatic asthma.

Administration, Inhalation↗

Inhaled NO and almitrine bismesylate in patients with acute respiratory distress syndrome: effect of noradrenalin.

The combination of inhaled nitric oxide with almitrine bismesylate has been proposed for the management of acute respiratory distress syndrome in order to divert pulmonary blood flow away from poorly ventilated toward well-ventilated areas. The aims of this prospective and comparative study were to: 1) confirm the beneficial effects on oxygenation of this association; 2) evaluate the haemodynamic effects of this association; and 3) evaluate the influence of noradrenaline (a nonspecific vasoconstrictor) on the modification of gas exchange related to inhaled NO and/or almitrine bismesylate. Forty-one sedated paralysed and ventilated patients were investigated. Haemodynamic and blood gas measurements were performed in a fixed order: baseline; inhalation of NO for 30 min.; intravenous infusion of almitrine bismesylate; and concomitant administration of inhaled NO and almitrine bismesylate. Inhaled NO and almitrine bismesylate increased arterial oxygen tension (Pa,O2)/inspiratory oxygen fraction (FI,O2) (p<0.001). The association of inhaled NO with almitrine bismesylate resulted in a dramatic improvement in Pa,O2/FI,O2 (p<0.0001 versus almitrine bismesylate, p<0.05 versus inhaled NO). In patients receiving noradrenalin (n = 19), almitrine bismesylate had no effect on oxygenation. The present study confirmed that the combination of inhaled NO with almitrine bismesylate improved oxygenation, and demonstrated that almitrine bismesylate has no effect on oxygenation in patients receiving noradrenalin.

Administration, Inhalation↗

Inspiratory flow rates and volumes with the Aerolizer dry powder inhaler in asthmatic children and adults.

OBJECTIVE: To assess the peak inspiratory flow rate (PIFR) and forced inspiratory vital capacity (FIVC) through the formoterol (Foradil*) Aerolizer* in patients with mild, moderate and severe asthma. RESEARCH DESIGN AND METHODS: PIFR and FIVC were assessed in 33 adults and 32 children using a spirometer alone (baseline), a spirometer with an adaptor, and a spirometer with an adaptor and the Aerolizer inhaler (placebo loaded). RESULTS: Of adult patients using the Aerolizer inhaler, 73% had PIFR values of >100 l/min and 91% had values of >60 l/min. PIFR in adults was reduced from a mean baseline of 283 l/min to 118 l/min through the loaded Aerolizer inhaler. Similarly, 75% of children using the Aerolizer inhaler had PIFR values >80 l/min and 91% had values of > 60 l/min. The mean PIFR in children was reduced from a baseline of 154 l/min to 100 l/min through the loaded Aerolizer inhaler. Only small mean decreases from baseline were observed in FIVC through the loaded Aerolizer inhaler: 8.4% in adults and 3.8% in children. FIVC values of > 2.0 litre were achieved in 82% of adults, and 81% of children achieved FIVC values of >1.5 litre. CONCLUSIONS: This study, albeit in a relatively small patient population, suggests that most children and adults with asthma can generate PIFRs of > 60 l/min and FIVCs of > 1.5 litre through the Aerolizer inhaler regardless of their disease severity. Such findings compare extremely favourably with other dry powder inhalers.

Adolescent↗

Job categories and their effect on exposure to fungal alpha-amylase and inhalable dust in the U.K. baking industry.

Enzymes in flour improver, in particular fungal alpha-amylase, are known to be a significant cause of respiratory allergy in the baking industry. This study measured total inhalable dust and fungal alpha-amylase exposures in U.K. bakeries, mills, and a flour improver production and packing facility and determined whether assignment of job description could identify individuals with the highest exposures to fungal alpha-amylase and inhalable dust. A total of 117 personal samples were taken for workers in 19 bakeries, 2 mills, and a flour improver production and packing facility and were analyzed using a monoclonal based immunoassay. Occupational hygiene surveys were undertaken for each site to assign job description and identify individuals who worked directly with flour improvers. Analysis of exposure data identified that mixers and weighers from large bakeries had the highest exposures to both inhalable dust and fungal alpha-amylase among the different categories of bakery workers (p<.01). Currently, the maximum exposure limit for flour dust in the United Kingdom is 10 mg/m(3) (8-hour time-weighted average reference period). In this study 25% of the total dust results for bakers exceeded 10 mg/m(3), and interestingly, 63% of the individuals with exposure levels exceeding 10 mg/m(3) were weighers and mixers. Individuals who worked directly with flour improvers were exposed to higher levels of both inhalable dust and fungal alpha-amylase (p<.01) than those who were not directly handling these products. Before sensitive immunoassays were utilized for the detection of specific inhalable allergens, gravimetric analysis was often used as a surrogate. There was a weak relationship between inhalable dust and fungal alpha-amylase exposures; however, inhalable dust levels could not be used to predict amylase exposures, which highlights the importance of measuring both inhalable dust and fungal alpha-amylase exposures.

Allergens↗

Relationship between pharmacokinetics and hemodynamic effects of inhaled isobutyl nitrite in conscious rats.

Our objective was to examine the pharmacokinetic/hemodynamic properties of inhaled isobutyl nitrite (ISBN) in rats. ISBN is one of the volatile organic nitrites that has been used primarily as a drug of abuse. Recent studies indicate, however, that these compounds may be superior to organic nitrates for cardiovascular use because they do not produce vascular tolerance. Rats inhaled ISBN over an exposure range of 20 to 1200 ppm for 1 hour. The effects of ISBN on blood pressure and heart rate were determined and blood concentrations of ISBN were analyzed with use of gas chromatography. Apparent steady-state blood levels of ISBN were achieved during inhalation and were linear with exposure concentration (blood concentration: 0.05 to 3.5 microM; exposure concentration: 23 to 1177 ppm; r2= 0.92). Inhaled ISBN caused rapid, dose-dependent, and parallel reductions in systolic and diastolic pressure, while heart rate increased maximally to 22%. A sigmoid Emax model could describe the mean arterial pressure effect of inhaled ISBN (Emax= 55%; EC50= 0.51 microM). After inhalation, blood pressure and heart rate quickly returned to baseline, without any withdrawal rebound effect. Inhaled ISBN produced a rapid onset of action on heart rate and blood pressure, and these effects were sustained over 60 minutes of exposure. Abrupt drug withdrawal did not lead to hemodynamic rebound. The blood pressure effects were related to ISBN blood concentration by the sigmoid Emax model. These results provide new information on the pharmacokinetic/pharmacodynamic relationship of a representative nitrite inhalant.

Administration, Inhalation↗

Investigation of mouth washing by patients after inhaling corticosteroids.

We report an effective method for mouth washing after inhalation of corticosteroids for the prevention of local adverse effects such as hoarseness and oropharyngeal candidiasis. This method involves gargling and rinsing immediately after inhalation, repeated at least twice. We performed a questionnaire survey on mouth washing after inhalation of corticosteroids of 19 inpatients who used inhaled corticosteroids at the University of Tokyo Hospital. The questions concerned: 1) awareness of local adverse effects of inhaled corticosteroids; 2) gargling and rinsing habits; 3) repeating mouth washing at least twice; and 4) mouth washing immediately after inhalation. The percentage of patients correctly performing the individual maneuvers were: 1) 63.2%; 2) 36.8%; 3) 36.8%; and 4) 63.2%. The percentage of patients performing our recommended method of mouth washing (all four elements) was 11%. These results suggest that patients receiving inhaled corticosteroids poorly comprehend mouth washing procedures after inhalation of corticosteroids. It is important that pharmacists advise patients on the correct method of mouth washing.

Administration, Inhalation↗

Hematotoxicity and carcinogenicity of inhaled benzene.

CBA/Ca male mice have been exposed to benzene in air at 10, 25, 100, 300, 400, and 3000 ppm for variable intervals 6 hr/day, 5 days/week for up to 16 weeks. Two weeks of inhaling 10 ppm produced no hematologic effects; 25 ppm induced a significant lymphopenia. Inhalation of 100, 300, and 400 ppm produced dose-dependent decreases in blood lymphocytes, bone marrow cellularity, marrow content of spleen colony-forming units (CFU-S) and an increased fraction of CFU-S in DNA synthesis. Exposure of mice to 300 ppm for 2, 4, 8, and 16 weeks produced severe lymphopenia and decrease in marrow CFU-S. Recovery was rapid and complete after 2 and 4 weeks of exposure. After 8 and 16 weeks of exposure, recovery of lymphocytes was complete within 8 weeks. It took 16 weeks for the CFU-S to recover to that of the age-matched controls after 8 weeks of exposure and 25 weeks to recover to age-matched after 16 weeks of exposure. Inhalation of 3000 ppm for 8 days was less damaging than inhalation of 300 ppm for 80 days (same integral amount of benzene inhaled). The inhalation of 3000 ppm has not increased the incidence of leukemia or shortened its latency for development. Inhalation of 300 ppm 6 hr/day for 16 weeks significantly increases the incidence of myelogenous neoplasms in male CBA/Ca mice. Inhalation of 100 ppm for same interval does not influence incidence of myelogenous neoplasms but does increase incidence of solid neoplasms particularly in female CBA/Ca mice. Benzene is a potent carcinogen in CBA/Ca mice.

Administration, Inhalation↗