Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Finite Element Analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59Linked to original sources

Computational modeling of ligament mechanics.

This article provides a critical review of past and current techniques for the computational modeling of ligaments and tendons. A brief overview of relevant concepts from the fields of continuum mechanics and finite element analysis is provided. The structure and function of ligaments and tendons are reviewed in detail, with emphasis on the relationship of microstructural tissue features to the continuum mechanical hehavior. Experimental techniques for the material characterization of biological soft tissues are discussed. Past and current efforts related to the constitutive modeling of ligaments and tendons are classified by the particular technique and dimensionality. Applications of one-dimensional and three-dimensional constitutive models in the representation of the mechanical behavior of joints are presented. Future research directions are identified.

Animals↗

If bone is the answer, then what is the question?

In the 19th century, several scientists attempted to relate bone trabecular morphology to its mechanical, load-bearing function. It was suggested that bone architecture was an answer to requirements of optimal stress transfer, pairing maximal strength to minimal weight, according to particular mathematical design rules. Using contemporary methods of analysis, stress transfer in bones was studied and compared with anatomical specimens, from which it was hypothesised that trabecular architecture is associated with stress trajectories. Others focused on the biological processes by which trabecular architectures are formed and on the question of how bone could maintain the relationship between external load and architecture in a variable functional environment. Wilhelm Roux introduced the principle of functional adaptation as a self-organising process based in the tissues. Julius Wolff, anatomist and orthopaedic surgeon, entwined these 3 issues in his book The Law of Bone Remodeling (translation), which set the stage for biomechanical research goals in our day. 'Wolff's Law' is a question rather than a law, asking for the requirements of structural optimisation. In this article, based on finite element analysis (FEA) results of stress transfer in bones, it is argued that it was the wrong question, putting us on the wrong foot. The maximal strength/minimal weight principle does not provide a rationale for architectural formation or adaptation; the similarity between trabecular orientation and stress trajectories is circumstantial, not causal. Based on computer simulations of bone remodelling as a regulatory process, governed by mechanical usage and orchestrated by osteocyte mechanosensitivity, it is shown that Roux's paradigm, conversely, is a realistic proposition. Put in a quantitative regulatory context, it can predict both trabecular formation and adaptation. Hence, trabecular architecture is not an answer to Wolff's question, in the sense of this article's title. There are no mathematical optimisation rules for bone architecture; there is just a biological regulatory process, producing a structure adapted to mechanical demands by the nature of its characteristics, adequate for evolutionary endurance. It is predicted that computer simulation of this process can help us to unravel its secrets.

Animals↗

Application of scanning acoustic microscopy for assessing stress distribution in atherosclerotic plaque.

Scanning acoustic microscopy (SAM) was equipped to assess the acoustic properties of normal and atherosclerotic coronary arteries. The SAM image in the atherosclerotic lesion clearly demonstrated that the sound speed was higher than that in the normal intima, and that the variation of elasticity was found within the fibrous cap of the plaque. Young's elastic modulus of each region was calculated and the finite element analysis was applied to derive the stress distribution in these arterial walls. In a case of normal coronary artery, the stress was dominant in the intima and the distribution was rather homogeneous and in a case of atherosclerosis, high stress was concentrated to the relatively soft lesion in the fibrous cap overlying lipid pool. SAM provides information on the physical properties, which cannot be obtained by the optical microscope. The results would help in understanding the pathological features of atherosclerosis.

Acoustics↗

The development of a test specification to determine the rollover protection of passengers in light commercial vehicles fitted with canopies.

In this paper, a basic test specification is proposed to assess the structural integrity of a canopy that covers the load-area of a light commercial vehicle (LCV) used to carry passengers in the rear. The proposed test specification is a first step towards improving the safety of these passengers during rollover accidents. Different test methods were evaluated for applicability, ease of use and financial implications. The mass and geometric characteristics of three different one-ton LCVs were experimentally obtained and used to determine the minimum lateral velocity that will result in a rollover should a tripping mechanism be encountered. These velocities, in conjunction with other published data, were used to determine the energy required for a pendulum qualification test. It was decided that 7.7 kJ of energy delivered by a pendulum travelling between 4 and 7 m/s just prior to impact would be the most representative load case. A finite element analysis (FEA) of the proposed impact test on a specimen canopy was completed. Thereafter, the actual pendulum impact test was conducted to demonstrate the applicability of the proposed test procedure as well as the correlation with the FEA. It was shown that both FEA and actual testing are viable qualification procedures and that they can in fact be used to reliably assess the strength of the canopy. Finally, the outline of a test specification was developed and proposed, which can be used by national regulatory institutions to assess the structural integrity of commercially manufactured canopies.

Accidents, Traffic↗

A finite element formulation and program to study transient swelling and load-carriage in healthy and degenerate articular cartilage.

The theory of poroelasticity is extended to include physico-chemical swelling and used to predict the transient responses of normal and degenerate articular cartilage to both chemical and mechanical loading; with emphasis on isolating the influence of the major parameters which govern its deformation. Using a new hybrid element, our mathematical relationships were implemented in a purpose-built poroelastic finite element analysis algorithm (u-pi-c program) which was used to resolve the nature of the coupling between the mechanical and chemical responses of cartilage when subjected to ionic transport across its membranous skeleton. Our results demonstrate that one of the roles of the strain-dependent matrix permeability is to limit the rate of transmission of stresses from the fluid to the collagen-proteoglycan solid skeleton in the incipient stages of loading, and that the major contribution of the swelling pressure is that of preventing any excessive deformation of the matrix.

Adaptation, Physiological↗

New role for the primate fovea: a retinal excavation determines photoreceptor deployment and shape.

In humans, an increasing density of foveal cone photoreceptors occurs slowly over several years after birth, and accounts for a region that subserves high visual acuity. Concurrently, inner retinal cells move centrifugally away from the foveal center. Such developmental rearrangements reflect complex cellular remodeling after the retinal neuronal cells have differentiated and have formed synapses. Explaining foveal morphogenesis is difficult, because differentiated neuronal cells seem incapable of moving actively. Presented here is a biomechanical explanation of how the above events occur. This hypothesis assumes that the cellular movements throughout the retinal layers occur passively as the eye grows and the retina is stretched. Retinal stretch was simulated using virtual engineering models that were analyzed with finite element analysis. A pit combined with retinal stretch causes the retinal layers to deform in a way that accounts for both the centrifugal and centripetal movement of various retinal cell types. Axially directed, tensile forces associated with stretching the retinal tissue surrounding the pit also accounts for the elongated morphology of foveal cone photoreceptors. These simulations suggest that a pit is required for both the centripetal displacement of cone cells toward the center of the fovea, and for the elongated foveal cone morphology. Since the primate fovea may have minimal impact on acuity, its primary role may be to initiate foveal morphogenesis in slowly developing eyes.

Animals↗

The effect of longitudinal pre-stretch and radial constraint on the stress distribution in the vessel wall: a new hypothesis.

It is well known that blood vessels shorten axially when excised. This is due to the perivascular tethering constraint by side branches and the existence of pre-stretch of blood vessels at the in situ state. Furthermore, vessels are radially constrained to various extents by the surrounding tissues at physiological loading. Our hypothesis is that the axial pre-stretch and radial constraint by the surrounding tissue homogenizes the stress and strain distributions in the vessel wall. A finite element analysis of porcine coronary artery and rabbit thoracic aorta based on measured material properties, geometry, residual strain and physiological loading is used to compute the intramural stresses and strains. We systematically examined the effect of pre-stretch and external radial constraint in both vessels. Our results show that both stretching in the axial direction and compression in the radial direction lead to a more homogeneous strain and stress state in the blood vessel wall. A "uniform biaxial strain" hypothesis is proposed for the blood vessel wall and the ramifications are discussed.

Animals↗

Functional shape of the skull in vertebrates: which forces determine skull morphology in lower primates and ancestral synapsids?

In order to determine the extent to which the shape of the synapsid skull is adapted for resisting the mechanical loads to which it is subjected, block- or simple plate-shaped finite-element models were constructed and loaded with external muscle and bite forces in locations estimated to resemble points of application of these forces. These 2D or 3D finite-element models were iteratively loaded and modified by removing elements that experience only low stresses, and the resulting morphologies of the models were compared with fossil skulls of synapsids and the skulls of extant mammals. The results suggest that the stress flows in these unspecific models are very similar to the arrangement of bone material in real skulls. Morphological differences between taxa depend on a few a priori conditions: length and position of the tooth rows in relation to the braincase, arrangement of muscles, position of the orbits, and position of the nasal opening. Given these initial conditions, finite-element analysis consistently reveals the close similarity between stress flows and real skulls. The major difference between mammal-like reptiles and primates is the size of the braincase. This difference accounts for most of the morphological divergence. The postorbital bar seems to be a constructional element of the skull, rather than a means to protect the eyes. The skull shapes of higher primates are determined mainly by masticatory forces and less by external forces acting on the head. This study demonstrates the utility of finite-element modeling for testing hypotheses regarding relationships between form and function in vertebrate skulls.

Animals↗

Etiology of idiopathic scoliosis. Computational study.

A review of the literature on the mechanical aspects of the etiology for idiopathic scoliosis reveals that the buckling hypothesis has been presented as a purely mechanical phenomenon. In an attempt to confirm the buckling hypothesis, a numerical simulation of growth and the resulting buckling phenomena was done by means of finite element analysis. It previously was observed that growth was induced in the T4 to T10 vertebrae. Only the sacrum was assumed to be stationary. From the growth analysis, a deformation process that mitigated thoracic kyphosis was obtained as observed in healthy children during early adolescence. From the buckling analysis, the first to the fourth buckling modes that correspond to the first side bending, first forward bending, first rotation, and second side bending modes were obtained. The shape of the fourth buckling mode (second side bending mode) was in good agreement with the clinical shape. Considering the potential for controlling these modes by posture change, it is concluded that the second bending mode in the coronal plane is one of the most likely etiologic candidates in the mechanics of thoracic idiopathic scoliosis.

Adolescent↗

Development of a finite element model of a transtibial socket liner--an initial study.

A number of computer models of limb loading by lower limb prostheses have been developed to date, however their accuracy and clinical usefulness is somewhat debatable. This paper is the first in a series describing investigations into the behaviour of a transtibial socket under compressive loading. The work focuses upon the socket liner and its role in reducing and redistributing stresses within the socket. This initial study used non-linear finite element analysis to replicate the effect of pressure loading on a polyurethane socket liner in the region of a bony prominence. It is a first step in understanding the load transfer between the residual limb, socket liner and socket of a transtibial prosthesis. The Mooney Rivlin material model [1] was used to simulate the polyurethane socket liner and compression tests in accordance with BS903 [2] were performed to gain the necessary data to calculate the Mooney Rivlin constants. Experimental validation showed that a very accurate, large-strain representation of the material was achieved. Future work will model more complex, three-dimensional geometries.

Artificial Limbs↗

Three-dimensional modelling of micromachined-ultrasonic-transducer arrays operating in water.

We report on the 3-D modelling of periodic arrays of capacitive micromachined ultrasonic transducers (cMUTs) operating in fluid. Specific developments have been performed to model biperiodic transducer arrays and to take into account radiation into any stratified media at the front-side as well as the back-side of the device. The model is based on a periodic finite-element-analysis/boundary-element-method (FEA/BEM). It is applied to micromachined ultrasonic transducers (MUTs), based on silicon-nitride-circular-membrane arrays on a silicon substrate, and operating in water. The spectrum characteristics of MUTs excited in phase are investigated, showing that very-large-band emission is achievable as previously demonstrated by many authors. However, other contributions are also found, depending on the excitation conditions, that do not radiate in the fluid. These contributions are identified as guided modes that could generate significant cross-talk effects. The origin and the nature of these modes is analyzed to gain insight in the actual operation of MUTs.

Equipment Design↗

Characterization of vibration and acoustic noise in a gradient-coil insert.

High-speed switching of current in gradient coils within high magnetic field strength magnetic resonance imaging (MRI) scanners results in high acoustic sound pressure levels (SPL) in and around these machines. To characterize the vibration properties as well as the acoustic noise properties of the gradient coil, a finite-element (FE) model was developed using the dimensional design specifications of an available gradient-coil insert and the concentration of the copper windings in the coil. This FE model was then validated using experimentally collected vibration data. A computational acoustic noise model was then developed based on the validated FE model. The validation of the finite-element analysis results was done using experimental modal testing of the same gradient coil in a free-free state (no boundary constraints). Based on the validated FE model, boundary conditions (supports) were added to the model to simulate the operating condition when the gradient-coil insert is in place in an MRI machine. Vibration analysis results from the FE model were again validated through experimental vibration testing with the gradient-coil insert installed in the MRI scanner and excited using swept sinusoidal time waveforms. The simulation results from the computational acoustic noise model were also validated through experimental noise measurement from the gradient-coil insert in the MRI scanner using swept sinusoidal time waveform inputs. Comparisons show that the FE model predicts the vibration properties and the computational acoustic noise model predicts the noise characteristic properties extremely accurately.

Acoustics↗

Athletes with unilateral spondylolysis are at risk of stress fracture at the contralateral pedicle and pars interarticularis: a clinical and biomechanical study.

BACKGROUND: Unilateral spondylolysis is common in youths; its clinical and biomechanical features, especially effects on the contralateral side, are not fully understood. HYPOTHESIS: Unilateral spondylolysis predisposes the contralateral side to stress fracture, especially in athletes actively engaged in sporting activities involving torsion of the trunk. STUDY DESIGN: Case series and descriptive laboratory study. METHODS: Thirteen athletes younger than age 20 with unilateral spondylolysis were included. The contralateral pedicle and pars of spondylolytic vertebrae were examined using computed tomography and magnetic resonance imaging. Using a finite element model of the intact ligamentous L3-S1 segment, stress distributions were analyzed in response to 400-N axial compression and 10.6-N.m moment in flexion, extension, lateral bending, and axial rotation. Unilateral spondylolysis was created in the model at L5. The stress results from the unilateral defect model were compared to the intact model predictions and correlated to the contralateral defects seen in patients. RESULTS: Among 13 patients, there were 6 early-, 2 progressive-, and 5 terminal-stage defects. Three (23.1%) showed contralateral stress fracture. Among them, 2 belonged to the progressive-stage and 1 to the terminal-stage spondylolysis group. The remaining 4 patients in the terminal defect group showed stress reactions, such as sclerosis at the contralateral pedicle. In the finite element analysis model with an L5 left spondylolysis, the stresses at the contralateral and pars interarticularis were found to increase in all loading modes, with increases as high as 12.6-fold compared to the intact spine. CONCLUSIONS: Unilateral spondylolysis could lead to stress fracture or sclerosis at the contralateral side due to an increase in stresses in the region. CLINICAL RELEVANCE: Surgeons should be aware of possibility of contralateral stress fractures in cases in which patients, especially athletes engaged in active sports, show unilateral spondylolysis and persistent low back pain complaints.

Adolescent↗

Interfacial stress transfer and property mismatch in discontinuous nanofiber/nanotube composite materials.

Novel nanotubes/nanofibers with high strength and stiffness did not lead to high failure strengths/strains of nanocomposite materials. Therefore, the interfacial stress transfer and possible stress singularities, arising at the interfacial ends of discontinuous nanofibers embedded in a matrix, subjected to tensile and shear loading, were investigated by finite element analysis. The effects of Young's moduli and volume fractions on interfacial stress distributions were studied. Round-ended nanofibers were proposed to remove the interfacial singular stresses, which were caused by high stiffness mismatch of the nanoscale reinforcement and the matrix. However, the normal stress induced in the nanofiber through interfacial stress transfer was still less than 2 times that in the matrix. This stress value is far below the high strength of the nanofiber. Therefore, the load transfer efficiency of discontinuous nanofibers or nanotube composites is very low. Hence, nanofibers or nanotubes in continuous forms, which also preclude the formation of singular interfacial stress zones, are recommended over discontinuous nanofibers to achieve high strengths in nanocomposite materials.

Finite Element Analysis↗

[Semi-automatic generation of finite element meshes fo dental preparations].

The mechanical properties and elastic behaviour of periodontal tissue are a decisive factor in understanding initial tooth mobility and bone remodelling processes in orthodontics. An experimental set-up was designed to precisely determine a tooth's elastic response to different loading conditions. Segments of pig's maxilla bearing separated molars were used, and their mechanical response to loading was recorded. Subsequently, finite element analysis (FEA) was performed on the basis of the experimental data. The combination of experimental and numerical methods was used to determine the material properties of the periodontal ligament (PDL). The geometries of the preparations were reconstructed and FE meshes generated semi-automatically with the aid of the special computer program, CAGOG (Computer Aided Generator for Orthodontic Geometries) to optimally match the experimental geometry. Nonlinear material parameters were determined for the PDL and verified by comparing experimental and numerical results obtained in other specimens with an error of about 10%. This good correlation indicates that the selected method of mesh generation is appropriate for creating realistic FE models that can be compared with experimental results.

Animals↗

Determination of the Poisson's ratio of the cell: recovery properties of chondrocytes after release from complete micropipette aspiration.

Chondrocytes in articular cartilage are regularly subjected to compression and recovery due to dynamic loading of the joint. Previous studies have investigated the elastic and viscoelastic properties of chondrocytes using micropipette aspiration techniques, but in order to calculate cell properties, these studies have generally assumed that cells are incompressible with a Poisson's ratio of 0.5. The goal of this study was to measure the Poisson's ratio and recovery properties of the chondrocyte by combining theoretical modeling with experimental measures of complete cellular aspiration and release from a micropipette. Chondrocytes isolated from non-osteoarthritic and osteoarthritic cartilage were fully aspirated into a micropipette and allowed to reach mechanical equilibrium. Cells were then extruded from the micropipette and cell volume and morphology were measured throughout the experiment. This experimental procedure was simulated with finite element analysis, modeling the chondrocyte as either a compressible two-mode viscoelastic solid, or as a biphasic viscoelastic material. By fitting the experimental data to the theoretically predicted cell response, the Poisson's ratio and the viscoelastic recovery properties of the cell were determined. The Poisson's ratio of chondrocytes was found to be 0.38 for non-osteoarthritic cartilage and 0.36 for osteoarthritic chondrocytes (no significant difference). Osteoarthritic chondrocytes showed an increased recovery time following full aspiration. In contrast to previous assumptions, these findings suggest that chondrocytes are compressible, consistent with previous studies showing cell volume changes with compression of the extracellular matrix.

Capillary Action↗

The dynamics in implantation for patients with clefts.

OBJECTIVE: To investigate the stresses and strains of an endosseous dental implant in patients with different types of cleft palate in a finite element model. MATERIALS AND METHODS: Seven three-dimensional (3D) maxillary models were designed on a personal computer according to computed tomography slice data obtained from seven dry skulls. Next, computer-aided modification was performed on each model to produce three other 3D models with different cleft patterns. Thus, four model types with different cleft patterns were designed and termed NORM (without cleft), ALVEOLAR (only alveolar cleft), PALATAL (only palatal cleft), and COMPLETE (complete cleft). An implant was embedded into the molar region of each model, and a 300-N vertical load and 50-N horizontal load were applied to simulate mastication. Under these conditions, the stresses occurring at the implant-bone interface were calculated by finite element analysis. RESULTS: Different stress patterns were observed between the models with a palatal cleft (PALATAL and COMPLETE) and those without palatal cleft (NORM and ALVEOLAR). Regarding vertical load application, greater stresses occurred in PALATAL and COMPLETE types than in NORM and ALVEOLAR types. On application of a horizontal load, though the stresses did not show quantitative difference, their vector patterns differed. CONCLUSION: In patients with palatal clefts, characteristic stress patterns occur on the bone-implant interface during mastication. This should be taken into consideration when performing an implant treatment in patients with clefts.

Alveolar Process↗

The mesh-matching algorithm: an automatic 3D mesh generator for finite element structures.

Several authors have employed finite element analysis for stress and strain analysis in orthopaedic biomechanics. Unfortunately, the definition of three-dimensional models is time consuming (mainly because of the manual 3D meshing process) and consequently the number of analyses to be performed is limited. The authors have investigated a new patient-specific method allowing automatically 3D mesh generation for structures as complex as bone for example. This method, called the mesh-matching (M-M) algorithm, generated automatically customized 3D meshes of anatomical structures from an already existing model. The M-M algorithm has been used to generate FE models of 10 proximal human femora from an initial one which had been experimentally validated. The automatically generated meshes seemed to demonstrate satisfying results.

Algorithms↗