Unusual pathologic manifestations of dissecting aortic aneurysm, including one example of so-called incomplete rupture.
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
OBJECTIVE: To assess the operation indications, preoperative evaluation, technique essentials and clinical prospect of endovascular stent-graft exclusion for aortic dissection. METHODS: From September 1998 to April 2003, endovascular stent-graft exclusion for aortic dissection (Stanford B) was preformed in 146 patients. CTA or MRA were used as preoperative evaluation methods. Graft was constructed from self-expanding Z-stents covered with a woven Dacron polyester fabric graft (Talent). The stent-grafts were inserted from the femoral or iliac artery to exclude the tear of dissection, and all operations were performed under DSA guidance. RESULTS: The grafts were installed successfully in 145 patients. In 119 patients only proximal tears were excluded, and 26 patients who had both the proximal and distal tears were excluded. The mean follow-up period was 16 months (1 - 54 months). Six patients died within the perioperative period, 2 patients died during the follow-up, 2 patients had recurrence of aortic dissection (Stanford A) and cured by Bentall operation. The others were in good state. No accidents related to the dissection and operation occurred. CONCLUSIONS: Endovascular graft exclusion may be a safe and effective treatment for selected patients with thoracic aortic dissection. Endoleak may lead to aneurysmal expansion and rupture. Further follow-up is necessary to evaluate its long-term effect.
Thirty-two patients with repaired type A aortic dissection were examined by transthoracic echocardiography (TTE) (n = 32), transesophageal echocardiography (TEE) (n = 30), computed tomography (CT) (n = 29), or a combination of all 3, to assess course and complications as a function of the surgical procedure. The mean follow-up period was 55.7 months (range 3 to 132). Surgery consisted of a replacement of the ascending aorta in 25 patients (group 1) with extension to the transverse aorta in 7 (group 2). The transverse diameter of the aorta, the persistence of the false lumen, thrombus formation and flow dynamics in the false lumen were evaluated by TEE. Ten patients (31%) had a dilation in the initial ascending aorta (sinus of Valsalva aneurysm in 6 patients, and a false aneurysm in the other 4). Three of 4 patients with a proximal pseudoaneurysm underwent operation after TEE and CT evaluation. In the descending thoracic aorta, there was good agreement between TEE and CT scan determinations of transverse vessel diameter. Persistence of flow within the false lumen was significantly more frequent in patients with a dilated aorta (p < 0.05), whereas thrombosis was seen more often and false lumen less often in patients with nondilated aorta. No significant differences in vessel status or outcome were observed between the 2 groups, although this may have been due to the small size of group 2. TEE is thus a well-tolerated method for postoperative follow-up of type A aortic dissection whatever the type of surgery. For the upper ascending aorta, CT provided sufficient data.
This study was designed to assess the feasibility of thoracic aorta opacification after intravenous injection of sonicated albumin microbubbles in patients with and without aortic dissection. Twenty-one patients were studied by transesophageal echocardiography. In 11 patients without aortic dissection, the opacification of the left ventricular outflow tract, aortic root and descending aorta was evaluated. Ten patients with aortic dissection were studied to assess perfusion of the true and false lumen. The left ventricular outflow tract, aortic root and descending aorta were opacified in all patients, with a systolic increase in contrast at visual analysis and at videodensitometry. The differentiation between false and true lumen was improved and was crucial in 1 case of type A chronic dissection. The intimal tear was detected in 7/9 cases by color Doppler vs 9/9 cases by contrast echocardiography. The noninvasive ultrasound opacification of thoracic aorta is feasible and may improve the diagnosis of aortic dissection.
Two cases of acute aortic dissection which developed compression of the true lumen due to retrograde perfusion during cardiopulmonary bypass were reported. In the first case, coronary reperfusion could not be achieved when the aortic cross-clamping was removed after Collins' method of aortic dissection. There was no blood flow from the true lumen through the aortic root while the false lumen was distended by the retrograde perfusion. After completion of antegrade perfusion through the arterial cannula inserted into the anastomosed site of the ascending aorta, coronary reperfusion was established and the heart beating could be thereby obtained. In the second case, the false lumen was gradually expanded, and the true lumen was completely obstructed by it. Reexpansion of the true lumen was achieved by initiation of antegrade perfusion through the cannula inserted into the graft replaced in the ascending aorta. Fortunately cerebral and cardiac complications were not found in both cases postoperatively. Compression of the true lumen is rare, but fatal complication that may occur during retrograde perfusion in surgical repair for aortic dissection of Stanford type A. Therefore, it is very important to replace the perfusion cannula in the true lumen of the reconstructed aorta for preventing insufficiency of coronary and cerebral circulation.
We carried out stent graft repair in two patients with Stanford type B thoracic aortic dissection. A 51-year-old male was admitted to our hospital because of thoracic aortic dissection. Chest CT revealed an aneurysm of the distal aortic arch. The entry was pointed out 1 cm distal from the take off of the left subclavian artery in three-dimensional CT (3 D-CT). He was treated with a Gianturco stent which was anchored into the 30 mm Hemashield graft under selective cerebral perfusion. Another case was a 72-year-old male with a descending aortic aneurysm. 3 D-CT showed that the entry existed 4 cm proximal to the celiac artery. We performed transluminal implantation of the spiral Z-stent covered with the woven Dacron graft. 3 D-CT was useful for the preoperative management and the surgical treatment of thoracic aortic dissection.
Acute type A aortic dissection is an uncommon complication with left ventricular assist device insertion, but is often fatal even if successfully repaired with conventional techniques including aortic valve repair. Residual aortic insufficiency is common because this valve is now subjected to systolic pressure. We present a novel technique for the repair of type A acute aortic dissection in patients with a left ventricular assist device with no chance of residual aortic insufficiency.
OBJECTIVE: To determine the most effective treatment, we performed a detailed comparative study of the clinical course of patients with type B aortic dissection with a patent or thrombosed false lumen who did not undergo surgery in the acute period. We examined the effect of patency of the false lumen on outcome. METHODS: Computed tomography scans of 138 patients with type B acute aortic dissection were reviewed. Of 138 patients, 110 were medically treated and survived the acute period. We focused on the outcome of these 110 patients, 62 with medically treated thrombosed false lumen (thrombosed group) and 48 with medically treated patent false lumen (patent group). We investigated factors influencing outcome among the 110 patients. The follow-up period was up to 10 years after the onset of aortic dissection. The three study endpoints were death from any cause, dissection-related death (aortic rupture, perioperative death, or death due to organ ischemia), and a dissection-related event (aortic rupture or surgery). In the patent group, we investigated factors influencing long-term outcome. RESULTS: Patency of the false lumen was an independent risk factor for dissection-related death (P = 0.038, hazard ratio=5.6, confidence interval=1.1-28) and for a dissection-related event (P = 0.000, hazard ratio=7.6, confidence interval=2.7-22) but not for death from any cause (P = 0.769, hazard ratio=1.2, confidence interval=0.45-2.91). In the patent group, location of the most dilated aortic segment at the distal arch was an independent risk factor for dissection-related death (P = 0.026, hazard ratio=13.6, confidence interval=1.4-135) and for a dissection-related event (P = 0.048, hazard ratio=2.6, confidence interval=1.0-6.9). CONCLUSIONS: Patency of the false lumen is a strong independent prognostic factor for type B aortic dissection. Location of the most dilated aortic segment at the distal arch is a significant risk factor in the patients with a patent false lumen.