Accuracy of alginate and elastomeric impression materials.

The accuracy of three alginates and seven elastomeric impression materials was determined. Impressions were taken of a truncated cone and poured with stone die. A steel ring fitting the steel cone was placed on the dies, and the discrepancy between the top surface of the ring and the die was measured. From these measurements the deviation between the base diameter of the die and that of the cone was calculated and used to express the accuracy of an impression material. All impressions showed a net shrinkage, resulting in too large a die stone and incomplete seating of the steel ring. The inaccuracy of the alginates varied between 44 and 188 microns. Blueprint regular was found to be significantly more accurate than the two other alginates investigated, and had a degree of accuracy comparable with that of the more accurate elastomeric impression materials. Within this group of materials the inaccuracy varied between 39 and 130 microns. Generally, the addition-curing silicones were more accurate than the polyethers. Baysilex and President regular body had the highest degree of accuracy of the elastomeric impression materials.

Alginates↗

Dermatoscopy and high frequency sonography: two useful non-invasive methods to increase preoperative diagnostic accuracy in pigmented skin lesions.

Dermatoscopy and high frequency sonography have recently been combined to increase diagnostic preoperative accuracy in the treatment of pigmented skin lesions. In this monocentric study 80 patients with pigmented skin lesions were evaluated clinically, by dermatoscopy, and 20 MHz-sonography followed by dermatohistopathological evaluation; 39 malignant melanomas, 37 common nevi, 3 dysplastic nevi, and 1 nevus Spitz were diagnosed histologically. In 72 of the 80 cases (91.3%) dermatoscopical diagnoses were confirmed by histopathology, compared to only 79% correct clinical diagnoses. For the mere clinical diagnosis of melanoma sensitivity was 79%, specificity was 78% and diagnostic accuracy was 65%. All diagnostic values increased by dermatoscopy: sensitivity reached 90%, specificity was 93%, and diagnostic accuracy was 83%. In order to determine tumor thickness preoperatively tumor thickness was measured by 20 MHz sonography. The correlation of tumor thickness between histometric and sonographic results was determined for nevi (r = 0.93) and melanoma (r = 0.95); 74.3% of melanomas were diagnosed correctly within an 0.2 mm range. Regarding the clinical important limit of 1 mm tumor thickness, 87.2% were diagnosed in accordance with histometric evaluation. An increase of 18% in diagnostic accuracy by dermatoscopy and 87.2% of correctly diagnosed cases of tumor thickness of malignant melanoma by high frequency sonography clearly demonstrate that these methods should be considered standard procedures in the diagnosis of pigmented skin lesions and will facilitate the decision on necessary surgical treatment.

Humans↗

Pre-donation assessment of kidneys by magnetic resonance angiography and venography: accuracy and impact on outcomes.

Reports on the accuracy of magnetic resonance angiography (MRA) and magnetic resonance venography (MRV) in evaluating living donor renovasculature employ few patients or omit the consequences of inaccurate scans. We retrospectively compared intraoperative findings to MRA/MRV scans in 146 donor-recipient pairs. For detecting accessory arteries and early branching, MRA sensitivity was 57.6%, specificity 96.5%, false positive rate 3.5%, false negative rate 42.4%, positive predictive value 82.6%, negative predictive value 88.6% and overall accuracy 87.7%. By excluding clinically inconsequential accessory arteries, MRA sensitivity rose to 73.1%, specificity to 96.7% and overall accuracy to 92.5%. For MRVs, sensitivity was 56.2%, specificity 99%, false positive rate 1%, false negative rate 43.8%, positive predictive value 90%, negative predictive value 94.8% and accuracy 94.5%. Inaccurate scans were associated with prolonged donor and recipient operations and more frequently reconstructed arteries, but did not affect clinical outcomes. Because most missed accessory arteries are inconsequential, MRA is a useful, less invasive method for defining donor renovascular anatomy.

Adult↗

Critical thinking and accuracy of nurses' diagnoses.

Interpretations of patient data are complex and diverse, contributing to a risk of low accuracy nursing diagnoses. This risk is confirmed in research findings that accuracy of nurses' diagnoses varied widely from high to low. Highly accurate diagnoses are essential, however, to guide nursing interventions for the achievement of positive health outcomes. Development of critical thinking abilities is likely to improve accuracy of nurses' diagnoses. New views of critical thinking serve as a basis for critical thinking in nursing. Seven cognitive skills and ten habits of mind are identified as dimensions of critical thinking for use in the diagnostic process. Application of the cognitive skills of critical thinking illustrates the importance of using critical thinking for accuracy of nurses' diagnoses. Ten strategies are proposed for self-development of critical thinking abilities.

Adolescent↗

Comparison of the accuracy of two ultrasonographic measurements in predicting the parturition date in the bitch.

OBJECTIVES: To compare the accuracy of two ultrasonographic measurements, inner chorionic cavity diameter and biparietal diameter, for the prediction of parturition date in small and medium size bitches. The effects of litter size and fetal sex ratio on the accuracy of the prediction were also investigated. METHODS: Ultrasonographic examinations were performed on pregnant bitches and, depending on the stage of pregnancy, the inner chorionic cavity diameter and biparietal diameter were measured. The mean value of the data of each structure was calculated and the predicted day of parturition was obtained by the application of equations derived from growth curves we previously developed for different size bitches. RESULTS: The parturition term was predicted with similar accuracy during early gestation, by the measurement of inner chorionic cavity diameter, as well as during late gestation, by the measurement of biparietal diameter. Litter size affected only biparietal diameter accuracy, whereas fetal sex ratio did not influence the estimation of the day of parturition. CLINICAL SIGNIFICANCE: Inner chorionic cavity diameter and biparietal diameter were equally reliable parameters in obtaining a reasonably accurate prediction of parturition date at any gestational period at which a bitch is examined.

Animals↗

Theoretical accuracy of model-based shape matching for measuring natural knee kinematics with single-plane fluoroscopy.

Quantification of knee motion under dynamic, in vivo loaded conditions is necessary to understand how knee kinematics influence joint injury, disease, and rehabilitation. Though recent studies have measured three-dimensional knee kinematics by matching geometric bone models to single-plane fluoroscopic images, factors limiting the accuracy of this approach have not been thoroughly investigated. This study used a three-step computational approach to evaluate theoretical accuracy limitations due to the shape matching process alone. First, cortical bone models of the femur tibia/fibula, and patella were created from CT data. Next, synthetic (i.e., computer generated) fluoroscopic images were created by ray tracing the bone models in known poses. Finally, an automated matching algorithm utilizing edge detection methods was developed to align flat-shaded bone models to the synthetic images. Accuracy of the recovered pose parameters was assessed in terms of measurement bias and precision. Under these ideal conditions where other sources of error were eliminated, tibiofemoral poses were within 2 mm for sagittal plane translations and 1.5 deg for all rotations while patellofemoral poses were within 2 mm and 3 deg. However, statistically significant bias was found in most relative pose parameters. Bias disappeared and precision improved by a factor of two when the synthetic images were regenerated using flat shading (i.e., sharp bone edges) instead of ray tracing (i.e., attenuated bone edges). Analysis of absolute pose parameter errors revealed that the automated matching algorithm systematically pushed the flat-shaded bone models too far into the image plane to match the attenuated edges of the synthetic ray-traced images. These results suggest that biased edge detection is the primary factor limiting the theoretical accuracy of this single-plane shape matching procedure.

Algorithms↗

Observer variation and the performance accuracy gained by averaging ratings of abnormality.

Six radiologists used continuous scales to rate 529 chest-film cases for likelihood of five different types of abnormalities (interstitial disease, nodule, pneumothorax, alveolar infiltrate, and rib fracture) in each of six replicated readings, yielding 36 separate ratings of each case for the five abnormalities. Separate data analyses of all cases and subsets of the difficult/subtle cases for each abnormality estimated the relative gains in accuracy (linear-scaled area below the ROC curve) obtained by averaging the case-ratings across (a) six independent replications by each reader (25% gain), (b) six different readers within each replication (34% gain), or (c) all 36 readings (48% gain). Although accuracy differed among both readers and abnormalities, ROC curves for the median ratings showed similar relative gains in accuracy, somewhat greater than those predicted from the measured rating correlations. A model for variance components in the observer's latent decision variable could predict these gains from measured correlations in the single ratings of cases. Depending on whether the model's estimates were based on realized accuracy gains or on rating correlations, about 48% or 39% of each reader's total decision variance (summed variance for positive and negative cases) consisted of random (within-reader) error that was uncorrelated between replications, another 10% or 14% came from idiosyncratic responses to individual cases, and about 43% or 47% was systematic variation that all readers found in the sampled cases.

Humans↗

Geometrical accuracy and fusion of multimodal vascular images: a phantom study.

The aim of this work was to compare the geometrical accuracy of x-ray angiography, magnetic resonance imaging (MRI), x-ray computed tomography (XCT), and ultrasound imaging (B-mode and IVUS, or intravascular ultrasound) for measuring the lumen diameters of blood vessels. An image fusion method was also developed to improve these measurements. The images were acquired from a phantom that mimic vessels of known diameters. After acquisition, the multimodal images were coregistered by manual alignment of fiducial markers, and then by maximization of mutual information. The fusion method was performed by means of a fuzzy logic modeling approach followed by a combination process based on a possibilistic theory. The results showed (i) the better geometrical accuracy of XCT and IVUS compared to the other modalities, and (ii) the better accuracy and smaller variability of fused images compared to single modalities, with respect to most diameters investigated. For XCT, the error varied from 0.4% to 5.4%, depending on the vessel diameter that ranged from 0.93 to 6.24 mm. For IVUS, the error ranged from -0.3% to 1.7% but the smallest vessel (0.93 mm) could not be investigated because of the probe size. Compared to others fusion schemes, the XCT-MRI fused images provided the best results for both accuracy (from -1.6% to 0.2% for the three largest vessels) and robustness (mean relative error of 1.9%). To conclude, this work underlined both the usefulness of the multimodality vascular phantom as a validation tool and the utility of image fusion in the vascular context.

Angiography↗

Accuracy of finite element model-based multi-organ deformable image registration.

As more pretreatment imaging becomes integrated into the treatment planning process and full three-dimensional image-guidance becomes part of the treatment delivery the need for a deformable image registration technique becomes more apparent. A novel finite element model-based multiorgan deformable image registration method, MORFEUS, has been developed. The basis of this method is twofold: first, individual organ deformation can be accurately modeled by deforming the surface of the organ at one instance into the surface of the organ at another instance and assigning the material properties that allow the internal structures to be accurately deformed into the secondary position and second, multi-organ deformable alignment can be achieved by explicitly defining the deformation of a subset of organs and assigning surface interfaces between organs. The feasibility and accuracy of the method was tested on MR thoracic and abdominal images of healthy volunteers at inhale and exhale. For the thoracic cases, the lungs and external surface were explicitly deformed and the breasts were implicitly deformed based on its relation to the lung and external surface. For the abdominal cases, the liver, spleen, and external surface were explicitly deformed and the stomach and kidneys were implicitly deformed. The average accuracy (average absolute error) of the lung and liver deformation, determined by tracking visible bifurcations, was 0.19 (s.d.: 0.09), 0.28 (s.d.: 0.12) and 0.17 (s.d.: 0.07) cm, in the LR, AP, and IS directions, respectively. The average accuracy of implicitly deformed organs was 0.11 (s.d.: 0.11), 0.13 (s.d.: 0.12), and 0.08 (s.d.: 0.09) cm, in the LR, AP, and IS directions, respectively. The average vector magnitude of the accuracy was 0.44 (s.d.: 0.20) cm for the lung and liver deformation and 0.24 (s.d.: 0.18) cm for the implicitly deformed organs. The two main processes, explicit deformation of the selected organs and finite element analysis calculations, require less than 120 and 495 s, respectively. This platform can facilitate the integration of deformable image registration into online image guidance procedures, dose calculations, and tissue response monitoring as well as performing multi-modality image registration for purposes of treatment planning.

Algorithms↗

Accuracy requirements of the primary x-ray spectrum in dose calculations using FFT convolution techniques.

The photon beam dose calculation methods using fast Fourier transform (FFT) convolution require that the primary beam energy spectrum is accurately known; however, a quantitative assessment of the required accuracy is not yet provided. In this study, the sensitivity of various parameters such as central axis depth dose and dose under attenuators to the incident photon spectrum was simulated and evaluated for 6- and 18-MV photon beams. The central axis depth-dose data using the modified spectrum were compared with those calculated using the original spectrum. Maximum errors on the central axis between these two sets of depth-dose data were found by changing the weighting of each energy bin of the primary spectrum. The maximum change in percent depth dose is proportional to the change in average incident energy relating to the quality of the x ray. To keep the maximum depth-dose error to less than 1%, the relative change in average energy brought about by changes in single spectral bins should be less than 2%. The accuracy required for each energy bin varies dramatically, dependent on its deviation from the original average energy and its relative weighting. For example, for the 6-MV x-ray spectrum, the energy bins centered around 0.76 MeV (first bin) and 6.8 MeV (fifth bin) need to have accuracies of 5% and 40%, respectively, to obtain a 1% accuracy in percent depth dose.

Fourier Analysis↗

An image fusion study of the geometric accuracy of magnetic resonance imaging with the Leksell stereotactic localization system.

A special acrylic phantom designed for both magnetic resonance imaging (MRI) and computed tomography (CT) was used to assess the geometric accuracy of MRI-based stereotactic localization with the Leksell stereotactic head frame and localizer system. The acrylic phantom was constructed in the shape of a cube, 164 mm in each dimension, with three perpendicular arrays of solid acrylic rods, 5 mm in diameter and spaced 30 mm apart within the phantom. Images from two MR scanners and a CT scanner were obtained with the same Leksell head frame placement. Using image fusion provided by the Leksell GammaPlan (LGP) software, the coordinates of the intraphantom rod positions from two MRI scanners were compared to that of CT imaging. The geometric accuracy of MR images from the Siemens scanner was greatly improved after the implementation of a special software patch provided by the manufacturer. In general, much better accuracy was achieved in the transverse plane where images were acquired. Most distortion was found around the periphery while least distortion was present in the middle and most other parts of the phantom. For most intracranial lesions undergoing stereotactic radiosurgery, accuracy of target localization can be achieved within size of a voxel, especially with the Siemens scanner. However, extra caution should be taken for imaging of peripheral lesions where the distortion is the greatest.

Humans↗

MIC-based tuberculosis drug susceptibility testing using Sensititre MYCOTB: a diagnostic accuracy meta-analysis.

Accurate drug susceptibility testing (DST) is crucial for designing effective regimens for multidrug-resistant (MDR) and pre-extensively drug-resistant tuberculosis (pre-XDR TB). Sensititre MYCOTB enables simultaneous determination of minimum inhibitory concentrations (MICs) for multiple drugs, but its diagnostic performance varies across studies. This meta-analysis evaluated the diagnostic performance of Sensititre MYCOTB for key MDR and pre-XDR TB drugs. The protocol was registered in PROSPERO (CRD420251230599). PubMed, Cochrane, Google Scholar, Scopus, ONOS, Web of Science, ScienceDirect, and registries were systematically searched for studies published between 2010 and 2025. Studies comparing the Sensititre MYCOTB with reference DST for Mycobacterium tuberculosis complex (MTBC) were included. Bias assessment and pooled diagnostic accuracy estimates were generated. Fourteen studies, including 1,728 isolates, were analyzed. Rifampicin and isoniazid demonstrated high sensitivity (0.976 [95% CI: 0.94-0.99] and 0.977 [95% CI: 0.95-0.99]) and specificity (0.958 [95% CI: 0.84-0.98] and 0.957 [95% CI: 0.83-0.99], respectively) with low heterogeneity. Amikacin, kanamycin, and ofloxacin demonstrate good diagnostic accuracy, with high specificity (>0.98 [95% CI]). Moderate diagnostic accuracy was observed for ethambutol, streptomycin, ethionamide, and rifabutin. Cycloserine, moxifloxacin, and para-aminosalicylic acid showed inconsistent performance despite excellent specificity (>0.97 [95% CI]). Sensitivity analysis partially improved pooled sensitivity for moxifloxacin 0.801 (95% CI: 0.585-0.924) and para-aminosalicylic acid 0.76 (95% CI: 0.518-0.894), whereas cycloserine remained at 0.436 (95% CI: 0.190-0.725), although heterogeneity persisted. Sensititre MYCOTB DST demonstrates high diagnostic accuracy for MDR-TB and pre-XDR-TB drugs, while caution is required with cycloserine, moxifloxacin, and para-aminosalicylic acid. These findings support the integration of MIC-based testing into clinical decision-making.

Microbial Sensitivity Tests↗

Diagnostic accuracy of chest radiography in detecting mediastinal lymphadenopathy in suspected pulmonary tuberculosis.

OBJECTIVE: To estimate the diagnostic accuracy of chest radiography in the detection of chest lymphadenopathy in children with clinically suspected pulmonary tuberculosis. METHODS DESIGN: Prospective cross sectional study. SETTING: A short stay ward in a children's hospital in South Africa. PATIENTS: Consecutive children under 14 years of age admitted with suspected pulmonary tuberculosis. DIAGNOSTIC TEST: Antero-posterior and/or lateral chest x rays interpreted independently and blind to the reference standard by three primary care clinicians and three paediatricians, all with a special interest in tuberculosis. Reference standard: Spiral chest computed tomography (CT) with contrast injection. RESULTS: One hundred children (median age 21.5 months) were enrolled. Lymphadenopathy was present in 46 of 100 reference CT scans and judged to be present in 47.1% of x ray assessments. Overall sensitivity was 67% and specificity 59%. Primary care clinicians were more sensitive (71.5% v 63.3%, p = 0.047) and less specific (49.8% v 68.9%, p<0.001) than paediatricians. Overall accuracy was higher for the paediatricians (diagnostic odds ratio 3.83 v 2.49, p = 0.008). The addition of a lateral to an antero-posterior view did not significantly increase accuracy (diagnostic odds ratio 3.09 v 3.73, p = 0.16). Chance adjusted inter-observer agreement (kappa) varied widely between viewer pairs, but was around 30%. CONCLUSIONS: Detection of mediastinal lymphadenopathy on chest x ray to diagnose pulmonary tuberculosis in children must be interpreted with caution. Diagnostic accuracy might be improved by refining radiological criteria for lymphadenopathy.

Child, Preschool↗

Accuracy of clinical assessment of heart murmurs by office based (general practice) paediatricians.

AIM: To determine the diagnostic accuracy of physical examination by office based (general practice) paediatricians in the evaluation of heart murmurs. DESIGN: Each of 30 office based paediatricians blindly examined a random sample of children with murmurs (43% of which were pathological). Sensitivity and specificity were calculated and were related to paediatricians' characteristics. RESULTS: Mean (SD) sensitivity was 82 (24)% with a mean specificity of 72 (24)% in differentiating pathological from innocent murmurs, with further investigations requested for 54% of assessments. The addition of a referral strategy would have increased mean sensitivity to 87 (20)% and specificity to 98 (8)%. Diagnostic accuracy was not significantly related to the paediatricians' age, education or practice characteristics, but was related to referral practices and confidence in assessment. CONCLUSIONS: Diagnostic accuracy of clinical assessment of heart murmurs by office based paediatricians is suboptimal, and educational strategies are needed to improve accuracy and reduce unnecessary referrals and misdiagnosis.

Adolescent↗

Accuracy and precision of joint space width measurements in standard and macroradiographs of osteoarthritic knees.

OBJECTIVES: To improve the reproducibility and accuracy of joint space width (JSW) measurement as an assessment of cartilage loss in patients with osteoarthritis (OA) of the knee by determining how precision and accuracy of JSW measurement were altered by a computerised method of measurement, correction for radiographic magnification, radiography of the knee in the standing semiflexed view, and high definition macroradiography of the knee in the semiflexed view--taking JSW measurements from standard radiographs of OA knees in the extended view as the standard for comparison. METHODS: Twenty five OA and 10 nonarthritic knees were radiographed in the extended view and minimum JSW was measured manually. Conventional and x5 macroradiographs were taken in the semiflexed view. All radiographs were taken twice on the same day and repeated two weeks later. Automated computerised measurement of minimum JSW was obtained from digitally stored images of all radiographs. RESULTS: For medial compartment JSW measurements, computerised was more accurate than manual, correction for radiographic magnification improved precision and accuracy, measurements in the semiflexed view were more precise and accurate, and macroradiography increased measurement precision. For the lateral compartment JSW measurements, correction for radiographic magnification improved precision and accuracy, and the semiflexed view improved precision only. CONCLUSIONS: Protocols defining radiographic and mensural procedures are essential for quality control of knee radiography in the semiflexed view to permit accurate and reproducible measurement of JSW. Macroradiography provides greater precision of JSW measurement.

Adult↗

Poor accuracy and interobserver reliability of knee arthroscopy measurements are improved by the use of variable angle elongated probes.

OBJECTIVES: (a)To determine the accuracy and reliability of arthroscopic measurements of cartilage lesion diameter in an artificial right knee model; (b) to determine whether the use of a set of variable angle elongated probes improves performance; and (c) to identify other sources of variability. METHODS: Ovoid "lesions" were drawn on the five cartilage surfaces of four plastic knees models. Two observers assessed these 20 lesions arthroscopically, measuring two diameters in orientations parallel and orthogonal to the probe. Observer 1 (orthopaedic surgeon) and observer 2 (arthroscopic rheumatologist) made two sets of measurements, firstly with the conventional probe and five months later with the variable angle elongated (VAE) probes. The knees were disarticulated to determine true lesion diameter. RESULTS: Observer 1 had negligible bias and good accuracy regardless of orientation or probe type. Observer 2 demonstrated both bias and poor accuracy using the conventional probe. Both improved using VAE probes. Poor interobserver reliability with conventional probes also improved using VAE probes. Major sources of variability could be traced to the probe type, the characteristics of the operator, and the orientation of the lesion in relation to the probe; the lesion location itself did not cause variability. CONCLUSIONS: Variation in accuracy and poor interobserver reliability of measurements with conventional methods of cartilage lesion diameter measurement improved when specially designed measurement probes were used. Arthroscopic measurements performed as well as most clinical and radiographic measures. These findings have important implications for the use of arthroscopy as an outcome in multicentre trials where arthroscopists have different levels of experience.

Analysis of Variance↗

The quality of reporting of diagnostic accuracy studies published in ophthalmic journals.

AIM: To evaluate the quality of reporting of all diagnostic studies published in five major ophthalmic journals in the year 2002 using the Standards for Reporting of Diagnostic Accuracy (STARD) initiative parameters. METHODS: Manual searching was used to identify diagnostic studies published in 2002 in five leading ophthalmic journals, the American Journal of Ophthalmology (AJO), Archives of Ophthalmology (Archives), British Journal of Ophthalmology (BJO), Investigative Ophthalmology and Visual Science (IOVS), and Ophthalmology. The STARD checklist of 25 items and flow chart was used to evaluate the quality of each publication. RESULTS: A total of 16 publications were included (AJO = 5, Archives = 1, BJO = 2, IOVS = 2, and Ophthalmology = 6). More than half of the studies (n = 9) were related to glaucoma diagnosis. Other specialties included retina (n = 4) cornea (n = 2), and neuro-ophthalmology (n = 1). The most common description of diagnostic accuracy was sensitivity and specificity values, published in 13 articles. The number of fully reported items in evaluated studies ranged from eight to 19. Seven studies reported more than 50% of the STARD items. CONCLUSIONS: The current standards of reporting of diagnostic accuracy tests are highly variable. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies.

Diagnostic Techniques, Ophthalmological↗

Accuracy of cervicovaginal fetal fibronectin test in predicting risk of spontaneous preterm birth: systematic review.

OBJECTIVE: To determine the accuracy with which a cervicovaginal fetal fibronectin test predicts spontaneous preterm birth in women with or without symptoms of preterm labour. DESIGN: Systematic quantitative review of studies of test accuracy. DATA SOURCES: Medline, Embase, PASCAL, Biosis, Cochrane Library, Medion, National Research Register, SCISEARCH, conference papers, manual searching of bibliographies of known primary and review articles, and contact with experts and manufacturer. STUDY SELECTION: Two reviewers independently selected and extracted data on study characteristics, quality, and accuracy. DATA EXTRACTION: Accuracy data were used to form 2x2 contingency tables with spontaneous preterm birth before 34 and 37 weeks' gestation and birth within 7-10 days of testing (for symptomatic pregnant women) as reference standards. Data were pooled to produce summary receiver operating characteristic curves and summary likelihood ratios for positive and negative test results. DATA SYNTHESIS: 64 primary articles were identified, consisting of 28 studies in asymptomatic women and 40 in symptomatic women, with a total of 26 876 women. Among asymptomatic women the best summary likelihood ratio for positive results was 4.01 (95% confidence interval 2.93 to 5.49) for predicting birth before 34 weeks' gestation, with corresponding summary likelihood ratio for negative results of 0.78 (0.72 to 0.84). Among symptomatic women the best summary likelihood ratio for positive results was 5.42 (4.36 to 6.74) for predicting birth within 7-10 days of testing, with corresponding ratio for negative results of 0.25 (0.20 to 0.31). CONCLUSION: Cervicovaginal fetal fibronectin test is most accurate in predicting spontaneous preterm birth within 7-10 days of testing among women with symptoms of threatened preterm birth before advanced cervical dilatation.

Biomarkers↗