Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ATMOSPHERIC PRESSURE”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59Linked to original sources

A novel nanoflow interface for atmospheric pressure ionization mass spectrometry.

A novel spray-ionization technique for nanoflow liquid chromatography/mass spectrometry (nLC/MS) has been developed by modifying the sonic spray ionization (SSI) technique. A solution from a tapered fused-silica capillary is sprayed by a gas flow coaxial to the capillary, and ions produced are analyzed with an ion-trap mass spectrometer. The ion intensity is shown to have a steep threshold at a low gas velocity and to be much less dependent on the gas velocity than that of conventional SSI, in which the ion intensity is strongly dependent on the gas velocity and reaches its maximum at sonic velocity. Thus, we conclude that the concentration of charge in the solution at the tapered capillary tip with an inner diameter of 15 microm is almost at saturation so that charged droplets are produced from the solution by electrical force, rather than by sheer stress due to the gas flow. The ions are readily produced from these charged droplets. Preliminary results are compared with results obtained with a miniaturized electrospray unit.

Bradykinin↗

Simultaneous determination of cystathionine and NAc-cystathionine using liquid chromatography atmospheric pressure chemical ionization mass spectrometry.

A method for simultaneous determination of cystathionine and NAc-cystathionine in biological samples has been developed by using column liquid chromatography-mass spectrometry. The concentrations of cystathionine and NAc-cystathionine in urine, several tissues, and serum of propargylglycine-treated rats with experimental cystathioninuria were determined by scanning the [M + H]+ ions of each compound. The recoveries of authentic compounds were 95.69 +/- 4.44% (n = 10) for cystathionine and 91.59 +/- 5.26% (n = 10) for NAc-cystathionine after ion-exchange resin treatment. The contents of cystathionine and NAc-cystathionine in the urine of a patient with cystathioninuria were also measured. The results coincided well with those obtained using an amino acid analyzer.

Animals↗

Surface functionalization of silicon oxide at room temperature and atmospheric pressure.

A novel method to derivatize silicon surfaces with 3-mercaptopropylsilane molecules has been developed and optimized. This method is based on an argon flow that increases the evaporation rate of the silane molecules by lowering the partial pressure of the silane molecules in gas phase above the liquid silane, at room temperature. X-ray photoelectron spectroscopy studies of the surfaces showed a dense monolayer coverage as well as hydrolysis of the silane methoxy groups. Atomic force microscopy was used to investigate the roughness of the surfaces after each step of the derivatization process. Since the final surface has a measured surface roughness of 0.19 nm, this method will be especially useful for further synthetic routes and advanced single molecule detection studies of interactions on surfaces as well as improvement of existing conventional techniques for surface derivatization and analysis.

Letter↗

Mass spectrometry with plasma sources at atmospheric pressure--state-of-the-art and some developmental trends.

The state-of-the art and trends of development in ICP-MS are presented. Special reference is made to progress in plasma sources, which can be used as ion sources and, especially, the inductively coupled plasma and new microwave plasma sources. Further, progress in sample introduction for plasma mass spectrometry is discussed with special reference to new pneumatic nebulizers, enabling, e.g., work with microflows of solutions at high efficiency, new developments in ultrasonic nebulization, in electrothermal evaporation, laser ablation and hydride generation. Innovation in the types of mass spectrometers used is discussed with special reference to the use of reaction and collision cells, sector field mass spectrometry, time-of-flight mass spectrometry and multicollector mass spectrometers. Challenging applications in the field of speciation, especially in environmental samples with the example of the chromium speciation, and in materials analysis, with special reference to the analysis of ceramic powders with and without on-line matrix removal, are also discussed.

Journal Article↗

The analysis of conductive solid samples by r.f. capacitively coupled plasma at atmospheric pressure.

A radiofrequency capacitively coupled plasma (rf CCP) with tip-ring electrode geometry has been used for the analysis of Al, Co, Cr, Cu, Mn, Mo, Ni, and V in low and medium alloyed steel. The sample is used as one of the electrodes of the plasma torch. The influence of plasma power, argon flow rate and distance between the electrodes on the analytical signals has been studied. The limits of detection are in the range of 0.001 to 0.048%. The dynamic range is three orders of magnitude.

Journal Article↗

Glibenclamide in serum: comparison of high-performance liquid chromatography using fluorescence detector and liquid chromatography/mass spectrometry with atmospheric-pressure chemical-ionization (APCI LC/MS).

Comparative studies of high-performance liquid chromatographic and liquid chromatographic/mass spectrometric methods for the quantitative determination of glibenclamide in patient serum are described. The 4-methylcyclohexyl analogue of glibenclamide [N-(4-(beta-5-chloro-2-methoxybenzamidoethyl)benzenesulfonyl-N'-(4-methylcyclohexyl)-urea] is used as internal standard for both methods. After acidification of the sample, the analyte and internal standard are extracted with chloroform. For HPLC analysis, the glibenclamide and internal standard are derivatized to a highly fluorescent amine with 7-chloro-4-nitrobenzo-2-oxa-1,3-diazole (NBD-chloride). The glibenclamide derivative is detected by a fluorescence detector. For APCI LC/MS assay, a derivatization of the analyte is not required and the compounds are measured by selected ion monitoring (SIM). The accuracy, precision, and recovery of the compared methods are presented and discussed.

Journal Article↗

A rapid and specific assay, based on liquid chromatography-atmospheric pressure chemical ionization mass spectrometry, for the determination of MK-434 (a 5 alpha-reductase inhibitor) and its metabolites in plasma.

MK-434 is a new 5 alpha-reductase inhibitor. A sensitive and specific assay based on combined liquid chromatography-mass spectrometry (LC-MS) has been developed for the determination of this compound in plasma. The analyte was isolated from plasma by solid-phase extraction on a C18 cartridge. A related substance, L-654,066, was used as the internal standard. Extracts were separated on a 5-cm C18-reversed-phase high performance liquid chromatography column interfaced via the heated nebulizer probe to a corona discharge chemical ionization source. The mass spectrometer was operated in the positive ion MS-MS mode. The method had sufficient sensitivity, precision, accuracy, and selectivity for the analysis of clinical samples containing MK-434 and its two principal metabolites at concentrations in the range 0.5-50 ng ml-1. The chromatographic run time was < 5 min.

5-alpha Reductase Inhibitors↗

Cortisol and cortisone analysis in serum and plasma by atmospheric pressure photoionization tandem mass spectrometry.

OBJECTIVES: Cortisol metabolism is controlled by 11beta-hydroxysteroid dehydrogenase (11beta-HSD) isoenzymes, which interconvert cortisol and cortisone. Accurate measurement of the cortisol and cortisone concentrations and their ratio provide useful information about 11beta-HSD activity. METHODS: Cortisol and cortisone were extracted with methyl-tert-butyl ether from 100 microl of serum or plasma. The extract was evaporated, reconstituted with mobile phase, and analyzed by tandem mass spectrometry using a photoionization interface. The transitions monitored were: m/z 363 to 121 and 363 to 97 for cortisol, 361 to 163 and 361 to 105 for cortisone. RESULTS: Within-run and between-run coefficients of variation were less than 6% and 12%; 14% and 22%; 11% and 21% for cortisol, cortisone, and their ratio, respectively. The limit of detection was 1 microg/l for cortisol and 5 microg/l for cortisone. Normal ranges for cortisol and cortisone concentration and for their ratio in plasma (n = 120) determined as the central 95% were 33-246 microg/l for cortisol, 8-27 microg/l for cortisone, and 0.081-0.301 for the cortisone/cortisol ratio. CONCLUSIONS: We developed a simple sensitive method for cortisol and cortisone analysis in plasma and serum that uses a small sample volume. The method is very specific, fast, does not have any known interference, and is useful for diagnosis of variety of disease and pathologic conditions.

11-beta-Hydroxysteroid Dehydrogenases↗

Determination of dextromethorphan and its metabolite dextrorphan in human urine using high performance liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry: a study of selectivity of a tandem mass spectrometric assay.

Analytical method for the simultaneous determination of dextromethorphan (1) and dextrorphan (2) in urine, based on solid-phase extraction of drug from acidified hydrolyzed biological matrix, were developed. The analytes (1 and 2) and the internal standard (levallorphan, 3, IS) were detected by high-performance liquid chromatography-mass spectrometry (HPLC-MS/MS) in positive ionization mode using a heated nebulizer (HN) probe and monitoring their precursor-->product ion combinations of m/z 272-->215, 258-->201, and 284-->201 for 1, 2, and 3, respectively, in multiple reaction monitoring mode. The analytes and IS were chromatographed on a Keystone Prism reverse phase (50 mm x 2.0 mm) 5 microm column using a mobile phases consisting of a 35/65 or 27/73 mixtures of methanol/water containing 0.1% TFA adjusted to pH 3 with ammonium hydroxide pumped at 0.4 ml/min for 1 and 2, respectively. The limits of reliable quantification of 1 and 2 were 2 and 250 ng/ml, respectively, when 1 ml of urine was processed. The absence of matrix effect was demonstrated by analysis of neat standards and standards spiked into urine extracts originating from five different sources. The linear ranges of the assay were 2-200 and 250-20,000 ng/ml for 1 and 2, respectively. Assay selectivity was evaluated by monitoring the "cross-talk" effects from other metabolites into the MS/MS channels used for monitoring 1, 2, and 3. In addition, an interfering peak originating from an unknown metabolite of 1 into the quantification of dextromethorphan was detected, requiring an effective chromatographic separation of analytes from other metabolites of 1. The need for careful assessment of selectivity of the HPLC-MS/MS assay in the presence of metabolites, and the assessment of matrix effect, are emphasized.

Antitussive Agents↗

Determination of Salvinorin A in body fluids by high performance liquid chromatography-atmospheric pressure chemical ionization.

Salvinorin A was quantitated in human and rhesus monkey plasma, rhesus monkey cerebrospinal fluid, and human urine by negative ion LC-MS/APCI. The method for Salvinorin A has been fully validated, the LLOQ using FDA guidelines is 2 ng/mL for 0.5 mL plasma samples. The linear range was from 2 to 1000 ng/mL. Several derivatives in the Salvinorin family can also be analyzed by this method; d(3)-Salvinorin A was prepared and used as internal standard. The metabolite Salvinorin B can be semi quantitatively determined. The method has been used to establish that Salvinorin B is the principal metabolite of Salvinorin A ex vivo and to establish the analytical method to study in vivo samples.

Animals↗

Quantitative determination of cholesterol, sitosterol, and sitostanol in cultured Caco-2 cells by liquid chromatography-atmospheric pressure chemical ionization mass spectrometry.

In this study, we describe a simple liquid extraction (methanol/choloroform, 1:1, v/v) method for endogenous free cholesterol and administered sterols extracted from cultured Caco-2 cells. To quantify sterol contents in Caco-2 cells, a new HPLC-APCI-MS method was developed. All the sterols were baseline separated using reversed-phase column (C8, 2.1 mm x 150 mm, 3.5 microm) and isocratic conditions (90%, v/v, methanol-water mixture containing 0.2 mM ammonium acetate). The full scan mass spectra of sterols were measured by an ion trap mass spectrometer equipped with an APCI ion source. The intense fragment ions resulting from the loss of water [M+H-H2O]+ (m/z 369, 395, 397 and 399 for cholesterol, stigmasterol, sitosterol, and sitostanol, respectively) were used for determinations. The absolute extraction recovery of sterols from the spiked cell samples were 109.7+/-26.2, 105.7+/-5.1, 109.8+/-5.0 and 99.0+/-7.0% for cholesterol, stigmasterol, sitosterol, and sitostanol, respectively. Furthermore, no significant matrix effect was observed for the sterols in the cell samples. The sample assay was based on the internal standard method using stigmasterol as an internal standard. The method was linear over the concentration ranges of 0.45-9.0 microM (cholesterol) and 0.225-7.2 microM (sitosterol and sitostanol). The within- and between-day precision was less than 7% and accuracy ranged from 93.51 to 101.77%. The lowest limit of quantitation (LLOQ) was 0.225 microM for sitosterol and sitostanol, and 0.45 microM for cholesterol. The accuracy range was 95-106% and precision was lower than 9% for all LLOQ values.

Caco-2 Cells↗

Quantification of betamethasone in human plasma by liquid chromatography-tandem mass spectrometry using atmospheric pressure photoionization in negative mode.

Betamethasone is a synthetic corticosteroid designed to exert a marked glucocorticoid activity. As the free alcohol, betamethasone finds widespread clinical applications related to its anti-inflammatory and immunosuppressant activity. In the present study, a fast, sensitive, robust method was developed for the determination and quantification of betamethasone in human plasma by liquid chromatography coupled with tandem mass spectrometry, using photospray ionization in negative mode. Betamethasone was extracted from 0.5 ml human plasma by liquid-liquid extraction (LLE) using chloramphenicol as internal standard. The method has a chromatographic run of 2.5 min using a C(18) analytical column (100 mm x 2.1 mm i.d.) and the linear calibration curve over the range was linear from 0.05 to 50 ng ml(-1) (r(2)>0.993). The between-run precision, based on the relative standard deviation replicate quality controls was 94.1% (0.15 ng ml(-1)), 90.7% (4.0 ng ml(-1)) and 97.2% (40 ng ml(-1)). The between-run accuracy for the above-mentioned concentrations was 11.9, 9.0 and 9.8%, respectively. The method herein described was employed in a bioequivalence study of two formulations of dexchlorpheniramine/betamethasone 2 mg/0.25 mg tablets.

Betamethasone↗

Determination of vincristine in infant plasma by liquid chromatography-atmospheric pressure chemical ionization-mass spectroscopy.

An LC-MS method using APCI has been developed and validated for the determination of the anticancer drug vincristine in human plasma, using vinblastine as internal standard. Following solid-phase extraction (SPE) of the sample, the lower limit of quantitation (LLOQ) was 0.18 ng/ml, the lower limit of detection was 0.09 ng/ml, and the linear calibration range was 0.18-180 ng/ml. This method has been used to measure plasma concentrations of vincristine from 0.08 to 24 h post bolus in 29 infants as part of a pharmacokinetic study. Concentrations of vincristine at 24 h were 0.2-1.36 ng/ml.

Antineoplastic Agents, Phytogenic↗

Rapid isolation of biomarkers for compound specific radiocarbon dating using high-performance liquid chromatography and flow injection analysis-atmospheric pressure chemical ionisation mass spectrometry.

Repeated semi-preparative normal-phase HPLC was performed to isolate selected biomarkers from sediment extracts for radiocarbon analysis. Flow injection analysis-mass spectrometry was used for rapid analysis of collected fractions to evaluate the separation procedure, taking only 1 min per fraction. In this way 100-1000 microg of glycerol dialkyl glycerol tetraethers, sterol fractions and chlorophyll-derived phytol were isolated from typically 100 g of marine sediment, i.e., in sufficient quantities for radiocarbon analysis, without significant carbon isotopic fractionation or contamination.

Biomarkers↗