Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “AIR CONDITIONING”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59Linked to original sources

Guidelines for environmental infection control in health-care facilities. Recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee (HICPAC).

The health-care facility environment is rarely implicated in disease transmission, except among patients who are immunocompromised. Nonetheless, inadvertent exposures to environmental pathogens (e.g., Aspergillus spp. and Legionella spp.) or airborne pathogens (e.g., Mycobacterium tuberculosis and varicella-zoster virus) can result in adverse patient outcomes and cause illness among health-care workers. Environmental infection-control strategies and engineering controls can effectively prevent these infections. The incidence of health-care--associated infections and pseudo-outbreaks can be minimized by 1) appropriate use of cleaners and disinfectants; 2) appropriate maintenance of medical equipment (e.g., automated endoscope reprocessors or hydrotherapy equipment); 3) adherence to water-quality standards for hemodialysis, and to ventilation standards for specialized care environments (e.g., airborne infection isolation rooms, protective environments, or operating rooms); and 4) prompt management of water intrusion into the facility. Routine environmental sampling is not usually advised, except for water quality determinations in hemodialysis settings and other situations where sampling is directed by epidemiologic principles, and results can be applied directly to infection-control decisions. This report reviews previous guidelines and strategies for preventing environment-associated infections in health-care facilities and offers recommendations. These include 1) evidence-based recommendations supported by studies; 2) requirements of federal agencies (e.g., Food and Drug Administration, U.S. Environmental Protection Agency, U.S. Department of Labor, Occupational Safety and Health Administration, and U.S. Department of Justice); 3) guidelines and standards from building and equipment professional organizations (e.g., American Institute of Architects, Association for the Advancement of Medical Instrumentation, and American Society of Heating, Refrigeration, and Air-Conditioning Engineers); 4) recommendations derived from scientific theory or rationale; and 5) experienced opinions based upon infection-control and engineering practices. The report also suggests a series of performance measurements as a means to evaluate infection-control efforts.

Air Microbiology↗

Bubble generation and venous air filtration by hard-shell venous reservoirs: a comparative study.

We have previously shown significant bubble formation in Medtronic Maxima hard-shell venous reservoirs (HSVRs). In the present study, we not only investigated the mechanism of this bubble formation, but also the extent of bubble clearance by membrane oxygenators and arterial line filters. In addition, we also compared the performance of five HSVRs with respect to bubble formation and venous air filtration. Salvaged clinical CPB circuits containing different HSVRs were studied by downstream Doppler monitoring under fixed flow-decreasing volume, fixed volume-increasing flow, and entrained venous air conditions. Bubbles formed in the Medtronic Maxima top entry HSVR at volumes below 800 ml and flows above 3.5 l min-1, and were incompletely removed by a membrane oxygenator and arterial line filter. Decreased bubbling was seen when the reservoir atmosphere was flushed with CO2, suggesting that these bubbles formed in a fountain at the venous inflow. The Medtronic Maxima Forte HSVR formed significantly fewer bubbles at low volumes, and filtered venous air effectively. Negligible bubble formation occurred in the Sorin, Terumo, or Baxter reservoirs. The minimum recommended operating volume for the Medtronic Maxima top entry reservoir should be reset at 600 ml and this device should always be used with an arterial filter. Bubble formation is substantially reduced in the new Medtronic Maxima Forte HSVR and this device is a good filter for venous air.

Catheters, Indwelling↗

[Legionaire's disease (author's transl)].

In a review of all cases of legionaire's disease known so far the epidemiology, diagnosis and therapy of this disease are discussed. Risk factors have been shown to be stays in hotels and hospitals, especially if the rooms were subject to faulty air conditioning, water containers or to earthworks. Furthermore, the male sex and an immunosuppressive therapy were established as risk factors. The diagnosis can only be confirmed by increased titer in the indirect fluorescence test. Erythromycin and Rifampicin (as a supplementary medication) have proved the antibiotics of choice.

Air Pollutants↗

Autoxidation of packed almonds as affected by maillard reaction volatile compounds derived from roasting.

Shelled almonds of two Italian varieties, Romana and Pizzuta, peeled and unpeeled, were roasted and packed under different conditions: air (control), vacuum, and Maillard reaction volatile compounds (MRVc) derived from the roasting process. Samples were stored for approximately 8 months at room temperature, without light, and, at regular intervals, were collected and analyzed to evaluate the progress of lipid oxidation. Peroxide values, triglyceride oligopolymers, and oxidized triglycerides were evaluated during the storage time. Results showed that, although the MRVc atmosphere did not protect the lipid fraction of almonds as well as the vacuum condition; nevertheless, it was more protective than the control atmosphere, showing an antioxidant effect. The effect of the natural coating was a strong protection against lipid oxidation; in fact, only the unpeeled samples showed peroxide values lower than the threshold of acceptability (25 milliequiv of O(2)/kg of oil). Moreover, at the end of the storage period, Pizzuta almonds showed a greater deterioration than those of the Romana variety.

Cooking↗

Behavior of Listeria monocytogenes and Aeromonas spp. on fresh-cut produce packaged under equilibrium-modified atmosphere.

Storage experiments were conducted to follow the behavior of pathogens on fresh-cut vegetables (trimmed brussels sprouts, grated carrots, shredded iceberg lettuce, and shredded chicory endives) packaged under an equilibrium-modified atmosphere (EMA) (2 to 3% O2, 2 to 3% CO2, and 94 to 96% N2) and stored at 7 degrees C. As a comparison, fresh-cut vegetables were also packaged in a perforated high-barrier film (air conditions) and stored at 7 degrees C. In a first step, the shelf life of the vegetables in the two kinds of packages was determined by evaluating the microbiological quality as well as the sensorial quality (appearance, taste, and odor). In general, sensorial properties were faster in limiting the shelf life than microbiological criteria. The shelf life of the vegetables stored under an EMA was extended by 50% or more, compared with the air-stored vegetables. In a second storage experiment, the four fresh-cut vegetables were inoculated with a cocktail of psychrotrophic pathogens (Listeria monocytogenes, Aeromonas caviae [HG4]) and A. bestiarum (HG2) before packaging under an EMA and air at 7 degrees C. The inoculated pathogens were more influenced by the type of vegetable than by the type of atmosphere. No growth was detected on the brussels sprouts or on carrots (L. monocytogenes). Aeromonas spp. had a higher growth rate than L. monocytogenes on the shredded chicory endives and shredded iceberg lettuce at 7 degrees C.

Aeromonas↗

An attempt to demonstrate the increased resistance of selected bacterial strains during repeated exposure to UV radiation at 254 nm.

Evidence was provided that in a repeatedly irradiated bacterial suspension of Escherichia coli K12: AB 1157, 1886, 2463, under the described experimental conditions, gradually mutants more resistant to UV radiation survive. Under these circumstances it may happen that selection and an increase of bacterial clones with an increased UV resistance develop, manifested by a reduced effectiveness of UV radiation during repeated irradiation. Although the cumulating damage of DNA in microbes can lead to a reduction of their survival as well as a reduction of their absolute numbers, it can be hardly assumed that during practical use in air conditioning units or during disinfection of drinking water all bacteria will be destroyed. In that case even repeated UV irradiation is not necessarily a reliable disinfection tool.

Disinfection↗

Effects of grades and other loads on on-road emissions of hydrocarbons and carbon monoxide.

This project was developed to assess driving patterns that promote high emissions episodes, also known as emission excursions, particularly while driving on roads with grade. An instrumented vehicle was equipped to record driving conditions such as speed and grade, as well as measure emission rates of total hydrocarbons and carbon monoxide. Controlled runs with predetermined cruise speeds between 35 and 55 mph and accelerations less than 3.3 mph/second were conducted on flat terrain and on hills with grades ranging from 0 to 7%. The hills were located in metropolitan Los Angeles, both along freeways and arterial roads. For hydrocarbons, the increase in emissions was about 0.04 g/mile for each 1% grade increment. For carbon monoxide (CO), the increase was more dramatic: 3.0 g/mile for each 1% grade increment. For a fully occupied vehicle with four passengers on a 4.5% grade, emissions increased by 0.07 g/mile for hydrocarbons and 10.2 g/mile for CO. Air conditioning operation, at full setting, further increased emissions while driving on hills (4.5 and 6.7% grades) by 0.07 g/mile for hydrocarbons and 31.9 g/mile for CO.

Air Pollutants↗

Exposure to genotoxins present in ambient air in Bangkok, Thailand--particle associated polycyclic aromatic hydrocarbons and biomarkers.

Exposure to genotoxic compounds in ambient air has been studied in Bangkok, Thailand, by analysis of polycyclic aromatic hydrocarbons (PAHs) associated with particles and using different biomarkers of exposure. Eighty-nine male, non-smoking Royal Thai police officers were investigated. The police officers were divided into a high exposure group (traffic police) and low exposure (office duty). Particulate matter was collected using personal pumps (2 l/min) and the eight carcinogenic PAHs were analysed by standard procedures. The traffic police was exposed to a 20-fold higher level of total PAHs than office police (74.25 ng/m3 vs. 3.11; P= 0.001). A two-fold variation was observed between the different police stations. The major PAHs in all groups was benzo[g,h,l]pyrelene. Large inter-individual differences in biomarker levels were observed, but the level of all markers was statistically significantly higher in the traffic police group than in the office group. The level of 1-hydroxypyrene (1-HOP) was 0.181+/-0.078 (range 0.071-0.393) micromol/mol creatinine in the traffic group and 0.173+/-0.151 (P = 0.044) in the office group. The bulky carcinogen DNA-adduct level, determined by P32-post-labelling, was 1.6+/-0.9 (range 0.4-4.3) adducts/10(8) nucleotides in the traffic group and 1.2+/-1.0 (0.2-4.9) in the office group (P = 0.029; Mann-Whitney U-test). The serum PAH-albumin adduct level was 1.76 (0.51-3.07) fmol adducts/microg albumin in the traffic group and 1.35+/-0.77 (0.11-3.45; P = 0.001) in the office group. Lower biomarker levels were observed during the period when the traffic police officers were wearing a simple facemask, indicating that these masks protect against particle-associated PAHs. No statistically significant correlations were observed between biomarker levels and the level of individual PAHs or total PAH. Our data show, that people in Bangkok, who spend most of the day outside air-conditioned offices, are exposed to high levels of genotoxic PAHs. However, for people who spend their working day in offices, the exposure is similar to people living in other metropolitan areas.

Adult↗

Effects of a moderate nocturnal cold stress on daytime sleep in humans.

The effects of a nocturnal exposure to a cool environment on daytime recovery sleep was studied in eight young (20-25 years old) healthy volunteers. A set of standardized clothing (KSU ensemble type) was provided to each individual (estimated total thermal resistance: 0.6 clo). The subject kept awake was passively exposed from 22.30 to 07.30 hours to environments perceived as neutral (N) and comfortable or slightly cold (C) and uncomfortable. They were then allowed to sleep ad libitum (light out at 08.00 hours) under thermoneutral conditions (air temperature: 21 degrees C to 22 degrees C; clothing: cotton tee-shirt and pajama-pants; covering: one cotton sheet and one wool blanket). Sleep was recorded and scored according to the Rechtchaffen and Kales standard procedures. Esophageal temperature (T(es)) was recorded from 21.30 hours until the end of sleep. The nocturnal drops in T(es) were significantly different between N and C (p<0.01), this difference disappearing during sleep. No statistical difference was found between conditions for most of the sleep variables. Compared to N however, C resulted in a significant increase in rapid eye movement (REM) sleep duration (+35%, p<0.01) during the subsequent daytime sleep. It is hypothesized that the REM-sleep increase induced by the exposure to moderate cold is due to the thermal discomfort stress consciously perceived by the subject.

Adaptation, Physiological↗

[Molecular and cellular mechanisms for protecting the respiratory organs from hazardous effects].

Knowledge of the mechanisms of the body's defense from poor exposures underlies the pathogenetical approach to examining the influence of environmental factors on human health. The respiratory organs are protected from poor exposures by several interrelated systems and mechanisms. The most important ones are an inspired air conditioning system, a respiratory tract self-cleansing system, a pulmonary non-specific bactericidal protection system, an alveolar respiratory surface self-cleansing system, a toxic substance metabolic and neutralizing system, and a specific immune defense system. Free radicals also play a great role in the physiology and pathology.

Air Microbiology↗

Potential health risks from exposure to indoor formaldehyde.

An indoor air quality survey was conducted in Southern Louisiana to determine levels of airborne formaldehyde. Gas chromatography analyses of 419 air samples collected from 53 houses revealed levels of formaldehyde ranging from non-detectable to 6.60 mg/m3. Seventy four percent (312/419) of the samples had detectable amounts of airborne formaldehyde. Of the 312 positive samples, approximately 60% exceeded the American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) guideline of 0.123 mg/m3. The highest number of samples exceeding the formaldehyde benchmark were collected in winter. It would appear that in some Southern Louisiana houses, a high level of formaldehyde could serve as a potential upper respiratory irritant.

Air Pollution, Indoor↗

Three clusters of Bacillus pseudobacteremia related to a radiometric blood culture analyzer.

During a ten-month period from September 1981 to July 1982 three episodes of pseudobacteremia due to Bacillus species occurred at this 550-bed institution. The first involved eight isolates, the second 11, and the third seven isolates of the organism, all with the same antibiogram. The patients involved did not exhibit clinical signs of septicemia, and in only one case was more than one specimen per patient positive when multiple blood samples were obtained. Occasional blood cultures of Bacillus species identified in between clusters revealed a different antibiogram. Extensive epidemiologic investigation of patient locations, phlebotomists, and time of cultures yielded no common source. Components involved in the transport and processing of blood cultures, including the radiometric blood culture processor, were also sampled but without recovery of the organism. After the last episode, a layer of dust was noted inside the machine, and culture of this dust grew Bacillus spp. with the same antibiogram as those found in the blood cultures. The filter from an air conditioning unit in close proximity to the machine grew several species of Bacillus. It is presumed that Bacillus spores in the dust were introduced into the blood culture bottles following the heat sterilization of the gas sampling (inoculation/removal) needles. Modification of the cover of the machine was undertaken to prevent access of dust bearing microbes to the inside of the machine. In addition, maintenance now includes regular disinfection/cleaning of the "floor" of the machine, and more frequent changes of the air conditioner filter.

Autoanalysis↗

[Prevalence of changes in performance, subjective symptoms and occupational dermatitis before and after carrying out improvements in the surgical block of the Modena Polyclinic].

The Preventive Medicine Unit for Personnel in the USL N. 16 of Modena has conducted a study to evaluate the prevalence of subjective symptoms and professional dermatitis among nurses working in a general surgery operating theatre of the Modena "Policlinico" Hospital (36 and 41 employees were studied respectively in 1990 and 1991), before and after the installation of gas evacuators and a modification in the use of detergent and disinfectant substances. The study demonstrates that installation of gas evacuating systems, if not supported by an intervention of air-conditioning plant, does not sufficiently reduce alterations in subjective symptoms. On the other hand, the modifications in the use of detergent and disinfectants has demonstrated a favourable reduction in the prevalence of professional dermatitis (from 43% to 18%; chi2 = 4.35, p = 0.037).

Air Pollutants, Occupational↗

Optimized aeration by carbon dioxide gas for microalgal production and mass transfer characterization in a vertical flat-plate photobioreactor.

To optimize the aeration conditions for microalgal biomass production in a vertical flat-plate photobioreactor (VFPP), the effect of the aeration rate on biomass productivity was investigated under given conditions. Air enriched with 5% or 10% (v/v) CO(2) was supplied for the investigation at rates of 0.025-1 vvm. The CO(2) utilization efficiency, change of pH in the medium, and the optimum aeration rate were determined by evaluating biomass productivity. To investigate the VFPP mass transfer characteristics, the overall volumetric mass transfer coefficient, k(L)a, was evaluated for several different flat-plate sizes. Increasing the height of the VFPP could improve both the mass transfer of CO(2) and the illumination conditions, so this appeared to be a good method for scaling up. Based on a comparison of the k(L)a value at the optimum aeration rate with previously reported results, it was confirmed that the range of CO(2) concentration used in the experiments was cost-effective for mass culture.

Journal Article↗

Effect of heat delivery and extraction on airway conductance in normal and in asthmatic subjects.

Ten asthmatic and 10 normal subjects were exposed to 7 air conditions varying in temperature (-2 to 49 degrees C) and relative humidity (10 or 100%). Normocapnic hyperventilation for 3 min at 40% maximal voluntary ventilation was performed for each condition. A constant-volume body plethysmograph measured functional residual capacity and specific airway conductance (SGaw). Three to five sets of functional residual capacity and SGaw measurements were taken before and 1, 5, and 10 min after each challenge. All conditions that extracted heat from the airway caused SGaw to fall in both subject groups. In normal subjects, this response was greatest immediately after challenge. In asthmatic subjects, the immediate response exceeded the normal response, and airway function worsened in the 5 to 10 min after exposure. The quantity of heat extracted correlated moderately well with change from baseline SGaw in both normal (r = 0.55 at 5 min) and asthmatic (r = 0.64) subjects. When heat was added to the airway by hyperventilation of warm, humid air, SGaw increased in normal subjects. However, marked bronchoconstriction followed the same challenge in asthmatic subjects. Changing osmolality of the respiratory mucosa rather than thermal exchange may be responsible for the bronchospasm consequent to heat delivery.

Adult↗

Perception of thermal comfort during narcosis.

We examined the perception of thermal comfort in six male subjects immersed in water at 28 degrees C (study I) and 15 degrees C (study II), breathing either room air (AIR) or a normoxic mixture containing 30% N2O (N2O). Immersions were terminated if esophageal temperature (Tes) decreased by 2 degrees C from resting levels or to 35 degrees C. At regular intervals, subjects rated their perception of thermal comfort on a 21-point scale (thermal comfort vote, TCV; +10 = very, very hot, 0 = neutral, -10 = very, very cold). For similar decreases in Tes from resting preimmersion values (mean +/- SD = -0.90 degrees +/- 0.13 degrees C and -0.92 degrees +/- 0.15 degrees C during the AIR and N2O trials in study I, and -0.90 degree +/- 0.22 degree C and -0.89 degree +/- 0.27 degree C during the AIR and N2O trials in study II), subjects perceived the immersions as less cold during the N2O trials. The median TCVs for the AIR condition of -5 in study I and -7.75 in study II, were significantly lower than those reported by the subjects for the respective N2O conditions (1.75 in study I and -5.5 in study II). It is concluded that behavioral adjustments required for maintaining thermal balance may be diminished during narcosis due to the altered perception of thermal discomfort. Assuming that the effect of inert gas narcosis on thermoregulatory responses is similar to that of N2O, then combined with the significant attenuation of heat gain mechanisms by anesthetic gases, the attenuation of the perception of thermal comfort may represent a significant factor in the etiology of hypothermia observed in compressed air divers.

Body Temperature Regulation↗

Enhancement of in vivo tyrosine hydroxylation in the rat adrenal gland under hypoxic conditions.

We examined the effects of hypoxia (8% O2) on in vivo tyrosine hydroxylation, a rate-limiting step for catecholamine synthesis, in the rat adrenal gland. The hydroxylation rate was determined by measuring the rate of accumulation of 3,4-dihydroxyphenylalanine (DOPA) after decarboxylase inhibition. One hour after hypoxic exposure, DOPA accumulation decreased to 60% of control values, but within 2 h it doubled. At 2 h, the apparent Km values for tyrosine and for biopterin cofactor of tyrosine hydroxylase (TH) in the soluble fraction were unchanged, whereas the Vmax value increased by 30%. The content of total or reduced biopterin was unchanged, but the content of tyrosine increased by 80%. Tyrosine administration had little effect on DOPA accumulation under room air conditions but enhanced DOPA accumulation under hypoxia. After denervation of the adrenal gland, the hypoxia-induced increase in DOPA accumulation and in the Vmax value was abolished, whereas the hypoxia-induced increase in tyrosine content was persistent. These results suggest that in vivo tyrosine hydroxylation is enhanced under hypoxia, although availability of oxygen is reduced. The enhancement is the result of both an increase in tyrosine content coupled with increased sensitivity of TH to changes in tyrosine tissue content and of an increase in dependence of TH on tyrosine levels. The increase in the sensitivity of TH and in the Vmax value is neurally induced, whereas the increase in tyrosine content is regulated by a different mechanism.

Adrenal Glands↗

[The sick building syndrome].

The term "sick building syndrome" (SBS) has been used for several years to describe a number of mostly unspecific complaints of some occupants of air-conditioned buildings. Based on the literature, a definition of the SBS is given and some results of larger SBS studies carried out in Germany, Denmark and the United Kingdom are described. These studies show that SBS is a multifactorial event which may include physical, chemical, biological as well as psychological factors. In many cases, the occurrence of SBS in a building is due to insufficient maintenance of the HVAC system. SBS-induced investigations in a building should be carried out stepwise, the measurement of indoor air pollutants not being the first step. Strategies to avoid SBS must take into account factors specific to the building, the HVAC system and the equipment as well as psychological factors.

Air Microbiology↗