Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLIC RESINS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59Linked to original sources

Clinical results of the measurement of occlusal wear of complete dentures.

This study supports the clinical impression that acrylic resin teeth wear down faster than porcelain teeth but does not support Myerson's view that the total wear of acrylic resin opposing porcelain teeth is less than that of acrylic resin opposing acrylic resin teeth. There was a wide range of rate of wear in acrylic resin teeth opposing acrylic resin teeth. Dentures of the four subjects in the porcelain-only group showed considerably less wear. The dentures with acrylic resin teeth opposing porcelain teeth showed the same general trend, i.e., a high rate of wear for the acrylic resin teeth with very little for the porcelain teeth. Conclusive proof is given for the differing wear rates of acrylic resin and porcelain teeth when opposing like materials.

Acrylic Resins↗

Comparative bond strengths of plastic teeth to microwave-curing, heat-curing and 4-META containing denture base resins.

Bond strength of hardened plastic teeth or acrylic resin teeth to microwave-curing, conventional heat-curing and 4-META-containing denture base resins were comparatively investigated in this study. Effects of grinding and monomer coating of the tooth ridge lap were also studied. Bond strength of plastic denture teeth to microwave-curing denture base resin was slightly higher than the other two resins. With all denture base resins used, an increased bond strength was obtained with hardened plastic teeth by treatment of tooth ridge lap but not with acrylic resin teeth. However, scattering of the bond strength was reduced by treatment of tooth ridge lap in acrylic resin teeth specimens. With hardened plastic teeth specimens, fracture in the base resin was increased by monomer coating. With acrylic resin teeth specimens, no specific fracture patterns were demonstrated by treatment of tooth ridge lap. Fracture occurred mostly in the acrylic resin teeth. These results suggest that bond strength of both denture teeth to microwave-curing or 4-META-containing denture base resin was increased or solidified by grinding or monomer coating of tooth ridge lap.

Acrylic Resins↗

Peak temperatures of some prosthetic acrylates on polymerization.

The aim of this study was to determine peak temperatures of some prosthetic acrylic resins at the time of polymerization. The acrylic resins included two temporary restoration resins, three autopolymerizing resins for different applications and one heat-cured denture base resin. The peak temperatures were measured with a ferro-constantan thermocouple from test specimens of three different volumes at different temperatures. The results revealed that with increasing volume of polymerizing acrylic resin the peak temperature also increased. In general, acrylic resins for temporary restorations had lower peak temperatures than other acrylic resins. However, despite the lower peak temperatures, the temperature of temporary restoration resins during polymerization can be as high as 82 degrees C. Therefore, to minimize thermal injuries of the tissues of vital tooth, dentists must be aware of the heat formation of the acrylic resins used in the oral cavity.

Acrylic Resins↗

Dimensional stability of denture bases following repair with microwave resin.

The dimensional stability of a commercially available acrylic resin, designed specifically for polymerization by microwave irradiation, was compared with that of a conventional water-bath-cured resin. Resin bases were processed on duplicate stone casts prepared from a cobalt chromium master die. Twenty bases were polymerized, using acrylic resin modified for rapid heat curing, in a water-bath at 100 degrees C for 22 min. A further 20 bases were polymerized using a microwave curing acrylic resin, in a conventional microwave oven at 500 W power output for 3 min. Ten bases from each group were sectioned in a parasagittal direction and repaired using the microwave curing resin. Following each curing cycle the fit of the posterior border of each base was evaluated via a silicone index formed between the base and the master die. The index was invested in stone and sectioned through the posterior palatal region to allow measurement of its thickness by means of an eyepiece micrometer. One-way analysis of variance and unpaired Student's t tests were employed to compare the differences in distortion at the initial cure and following repair. No significant differences were found in the distortion of the acrylic resin bases produced from the heat-cured or microwave-cured materials. All bases exhibited significant further distortion on repair with the microwave-cured acrylic resin.

Analysis of Variance↗

A simplified procedure for survey and design of diagnostic casts.

The procedure described for survey and design of diagnostic casts is applicable to either dental arch. It is presented in a sequential manner, is not complex, and will produce uniformly acceptable results. The following steps should be followed: (1) locate a path by tilting the cast; (2) mark the survey lines and tripod the cast; (3) outline the rest and guide planes; (4) draw minor connectors; (5) draw major connectors; (6) draw retention mesh for acrylic resin; (7) draw acrylic resin base extension; and (8) draw direct retainers (clasps).

Acrylic Resins↗

Effect of tissue conditioners on the dynamic viscoelastic properties of a heat-polymerized denture base.

STATEMENT OF PROBLEM: Little is known about the influence of tissue conditioners on physical property alteration of denture base resins. PURPOSE: This study evaluated the influence of a variety of commercial tissue conditioners on alteration of viscoelastic properties of a heat-polymerized denture base acrylic resin. MATERIAL AND METHODS: Four tissue conditioners and 1 heat-polymerized denture base acrylic resin were used. In one experiment, acrylic resin specimens (1.0-mm thick) were immersed in the liquid component of tissue conditioners for 36 hours. In another experiment, tissue conditioners were applied to acrylic resin specimens (0.5-mm and 1.0-mm thick) in a 2-mm layer; the specimens then were immersed in distilled water for 1 week. Control specimens for both groups had no lining and were immersed in distilled water for 36 hours and 1 week, respectively. Dynamic viscoelastic properties of the acrylic resin specimens were measured at 37 degrees C with an automatic viscoelastometer. Tensile storage modulus (E'), tensile loss modulus (E"), and loss tangent (tan delta) were determined at 1 Hz. These parameters were compared with analysis of variance and the Dunnett test at a predetermined significance level of.05. All statistical comparisons were made with reference to the control group and not to each other. RESULTS: Only the liquid of Hydro-Cast significantly reduced E' and increased tan delta of the acrylic resin (P<.05). Acrylic resin specimens 0.5-mm thick and lined with tissue conditioners tended to have lower E' and higher tan delta than the control. However, only Hydro-Cast and SR-Ivoseal significantly decreased E', and only Hydro-Cast raised tan delta of the acrylic resin (P<.05). No significant difference was found among the E" values. The tissue conditioners did not affect E', E", or tan delta of acrylic resin specimens 1.0-mm thick. CONCLUSION: Within the limitations of this study, some tissue conditioners significantly plasticized the denture base acrylic resin 0.5-mm thick. However, when the acrylic resin was 1.0-mm thick, no plasticization by the tissue conditioners was noted.

Acrylic Resins↗

Accuracy of wax, autopolymerized, and light-polymerized resin pattern materials.

PURPOSE: The marginal fit of MOD inlay and full-crown patterns fabricated from wax, autopolymerized acrylic resin, and two light-polymerized, diacrylate resin pattern materials was compared on standardized dies. MATERIALS AND METHODS: Four pattern materials were studied-two light-polymerized, diacrylate resin materials (Palavit G LC and Triad VLC Burnout Paste), an inlay wax, and an autopolymerized resin (Duralay). Patterns were fabricated using incremental and bulk techniques on stone dies made from addition silicone impressions of American Dental Association MOD and full-crown master dies. Gaps were measured with a measuring microscope in four marginal areas on the master dies at 1 and 24 hours after fabrication. RESULTS: For the MOD inlay patterns, marginal gaps ranged from 7 to 23 microns, and the light-polymerized, diacrylate resins and autopolymerized acrylic resin material had statistically smaller gaps than the inlay wax. For the full-crown patterns, marginal gaps ranged from 10 to 23 microns, with the exception of the autopolymerized acrylic resin prepared by the bulk technique (40 to 46 microns). With the incremental technique, the light-polymerized, diacrylate resins and inlay wax had statistically smaller gaps than the autopolymerized acrylic resin material. Overall, the incremental technique produced equal or smaller marginal gaps than the bulk technique for full-crown patterns. Generally, the patterns measured at 1 hour had smaller marginal gaps than at 24 hours. CONCLUSIONS: When measured on intra- and extracoronal master dies, the light-polymerized, diacrylate resins had equal or better marginal fit, compared with wax or autopolymerized acrylic resin, and were less affected by placement technique and storage. The marginal gaps of all four pattern materials ranged from 7 to 46 microns and are within the range of clinical acceptability.

Acrylic Resins↗

Accuracy of three interocclusal recording materials used to mount a working cast.

When remaining occlusal contacts of a dental posterior quadrant have been prepared to receive complete or partial coverage restorations, it is necessary to use an interocclusal recording material to approximate the casts for laboratory mounting procedures. Inaccuracy in working cast approximation leads to occlusal discrepancies in the fabricated restorations that require correction by the dentist at the time of insertion. Traditionally waxes, impression compounds, plasters, and zinc oxide-eugenol pastes have been used intraorally to record maxillomandibular relationships. Elastomeric materials have also been advocated. Manufacturers of thermoplastic resins have recently suggested that these materials may be used with ease and accuracy for interocclusal records. This investigation measured and compared the accuracies of a thermoplastic resin, an acrylic resin, and a vinyl polysiloxane interocclusal recording material. A measuring method was developed in which a computerized axiograph was used to record positional errors in three planes, next to the posterior teeth, with the interocclusal recording materials listed.

Acrylic Resins↗

The effect of glutaraldehyde and microwave disinfection on some properties of acrylic denture resin.

This study evaluated the effect of disinfection methods on the dimensional stability, flexural properties, and microhardness of a heat-polymerized denture acrylic resin. A 1- and 12-hour immersion period in 2% alkaline glutaraldehyde, and 3- and 15-minutes exposure to microwaves were employed as disinfection or sterilization procedures. Storage in water for 1 and 12 hours were used as the control. For each procedure 10 specimens were used. The results indicated that the linear changes observed were of no clinical importance. The same conclusion can be drawn for flexural properties and microhardness. The microwave method is a useful alternative to immersion disinfection.

Acrylic Resins↗

Comparative bond strengths of autopolymerising denture resin and light cured composite resin to denture teeth.

AIM: To investigate the shear bond strengths between light cured composite and autopolymerised acrylic resin bonded to acrylic resin denture teeth. METHODS: Surface treatments were used for the denture teeth included wetting with methylmethacrylate (MMA) monomer, composite bonding agent and acid etching. The samples were divided into seven groups. Two groups of specimens were immersed in distilled water for 30 days to hydrate the teeth. Five other groups of embedded denture teeth were stored in air at room temperature for 30 days. RESULTS: Analysis of variance indicated statistically significant differences between groups (P < 0.001). CONCLUSION: The greatest bond strengths to denture teeth were in acrylic resins polymerised with pressure and wetted with monomer. The bond strengths of hydrated and unhydrated samples gave similar results both with acrylic resins and composites.

Acrylic Resins↗

[Removable partial dentures applied by electric welding and soldering methods].

The joining procedure for uniting metal structures is very important in the dental clinic, and various kinds of metal joining methods have been performed for clinical application. The conventional torch soldering method using a blow torch has been generally adopted. However, it has several clinical problems, especially in the construction of removable partial dentures. The base metal wires made of a chromium-cobalt alloy are subject to changes in their mechanical properties caused by heating, when wrought wire clasps are joined to rests or frameworks. In addition to the flexibility of wrought wire clasps, damage to acrylic resin denture bases and acrylic resin teeth occurs in the repair of removable partial dentures. In this paper, the electric resistance welding and soldering methods were applied to attach wrought wire components to a removable partial denture framework to resolve the problems of the torch soldering method. As a result, it is suggested that these electric resistance welding and soldering methods have the following advantages, as compared with the conventional torch soldering method. 1. When using this electric resistance welding method, it is possible to fix metals temporarily to each other more securely and strongly than the conventional temporary fixation methods using sticky wax or acrylic resin. 2. The electric resistance soldering method does not require any heat insulation or a partition as the torch soldering method does, because the soldered area is only heated partially. 3. In the case of soldering electrically wrought wire clasps to metal structures such as rests and connectors, there is no fear of of overheating a wide area of wires.(ABSTRACT TRUNCATED AT 250 WORDS)

Chromium Alloys↗

Effect of some properties of metal strengtheners on the fracture resistance of acrylic denture base material construction.

In this study we investigated the effect of metal wire bonding to acrylic resin on the fracture resistance of an acrylic denture base material construction. Two different bonding methods were tested, and after measuring the resistance, the surface of the wires were examined by a scanning electron microscope. The effect that the placing of metal strengtheners in different positions in the acrylic resin had on the fracture resistance of the denture base material construction was also clarified. When three different positions of the metal wires in the acrylic resin were compared, the results showed that bonding of metal wire to acrylic resin somewhat enhanced the fracture resistance of test specimens, while the different positions of the wires had no effect on the fracture resistance.

Acrylic Resins↗

A novel technique for flat-embedding cryofixed plant specimens in LR white resin.

Acrylic LR White is used preferentially for many research applications because it possesses unique advantages over other commercially available resin types. LR White has low toxicity; its low viscosity and hydrophilic properties enable it to infiltrate specimens with comparative ease, and specimens embedded in LR White take up stains for light microscopy well and tend to retain superior antigenicity relative to other resins. These qualities make LR White a good choice for immunohistochemistry, light microscopy, and transmission electron microscopy. However, LR White does not heat-polymerize in the presence of oxygen, which precludes its use with many commercially available embedding molds. Furthermore, flat-embedding specimens in LR White is often an arduous task. Therefore, in this paper, we report on the development of novel flat-embedding chambers for use with LR White. Another goal of our studies was the rapid fixation of larger specimens. Chemical fixation was inadequate because of the time required for tissue infiltration, but cryofixation quickly and effectively immobilized intracellular organelles. Mean amyloplast positions differed in vertically oriented versus control specimens after chemical fixation, whereas no significant difference was observed after cryofixation. Furthermore, cryofixation provided acceptable preservation at the light microscopy level, even though our specimens were relatively larger. This underscores the utility of cryofixation for light microscopy determination of organelle positioning within plant cells.

Acrylic Resins↗

Denture base resins.

Numerous investigations have concluded that the conventional acrylic resins, processed with the usual technique of compression molding, produce dentures that are just as stable in dimension and as satisfactory as dentures produced with special resins and elaborate processing equipment. The physical properties of injection molded dentures are not superior to those of acrylic resin dentures produced by the usual carefully controlled compression molding techniques. Cold-curing acrylic resins produce dentures that are as satisfactory as those made from heat-curing resins.

Acrylic Resins↗

Acrylic resin-fiber composite--Part II: The effect of polymerization shrinkage of polymethyl methacrylate applied to fiber roving on transverse strength.

This study determined the effect of polymerization shrinkage of polymethyl methacrylate (PMMA) coating of fiber roving on the transverse strength of an acrylic resin-glass fiber composite. The test specimens were heat-cured acrylic resin reinforced with glass fibers. The glass fiber rovings were treated with four PMMA-MMA mixtures (30 specimens per group) of various ratios assumed to have different amounts of polymerization shrinkage. A transverse strength test was used to determine the fracture resistance of the test specimens and the polymerization shrinkage of the PMMA-MMA mixtures was measured. After the specimens were fractured, single glass fibers used to reinforce the test specimens were studied by SEM. The fracture resistance of the specimens was statistically different (p < 0.001) among treatments, and the polymerization shrinkage of the PMMA-MMA mixture also varied as the calculations predicted. The SEM micrographs showed differences in thickness of the acrylic resin layer on the surface of the fibers with PMMA-MMA mixtures of various ratios. According to the results, the ratio that caused only minor polymerization shrinkage of PMMA in the glass fiber roving improved the fracture resistance of the test specimens and seemed to increase the amount of PMMA inside the fiber roving.

Analysis of Variance↗

Bonding of synthetic resin teeth to microwave or heat activated denture base resin.

Bonding between acrylic resin teeth and a denture base material was investigated after microwave and hot water-bath curing. The specimens were tested according to the methods of the International Organisation for Standardisation (ISO 3336-1977 Dentistry-Synthetic Resin Teeth) using a universal testing machine. Superior bonding was found after hot water-bath curing. The generation of more porosities during microwave curing is the most likely explanation for the bond failures in this group. This finding is of clinical importance as the choice of curing method could influence the risk of loosening of acrylic teeth from the denture. No statistically significant difference in the fracture load between the two types of curing was found, which was expected as the load at fracture is not only related to the binding forces but also to factors such as the contact area and the fracture type.

Acrylic Resins↗

Comparing effects of tray treatment on the accuracy of dies.

The effects of tray treatments on the accuracy of dies from addition silicone impressions were investigated. Tray treatments included custom acrylic resin tray with adhesive, perforated custom acrylic resin tray without adhesive, and perforated custom acrylic resin tray with adhesive. No appreciable differences were found in the complete crowns among the three tray treatments on the first pours. Significant statistical differences observed in the MOD and occlusal inlays were nonetheless of questionable clinical significance. Adhesives are advisable if the impressions are poured repeatedly, however, to minimize accidental separation of the impression from the tray. The second casts were less accurate with complete crowns and MOD inlays when perforated trays were used without adhesives.

Acrylic Resins↗

A comparative analysis of the accuracy of implant transfer techniques.

Four different implant transfer techniques using two master cast systems (solid cast and Zeiser system) were evaluated and compared with respect to the accuracy with which abutment positions were reproduced. A stainless steel experimental analogue with two anterior and two posterior fixtures and abutments was fabricated. Polyether impressions (14 each) were made by use of four techniques, (I) nonsplinted, (II) splinted with dental floss and acrylic resin, (III) splinted with orthodontic wire and acrylic resin, and (IV) splinted with acrylic resin alone. The fourteen impressions of each technique were divided into two equal groups: group 1, solid cast system, and group 2, Zeiser system. The abutments of each master cast were measured vertically and horizontally with a profile projector. Statistical analysis indicated no significant difference between the splinted and nonsplinted techniques. The Zeiser system provided more accurate interabutment relationships for the posterior region than the solid cast system.

Acrylic Resins↗