Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Solid Phase Extraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58Linked to original sources

Application of solid-phase extraction in the method development for determination of SEPA, an acronym for soft enhancement of percutaneous absorption, in human, rat, and rabbit serum using GC-FID method.

A new nonaqueous topical minoxidil formulation containing SEPA (2-n-nonyl-1,3-dioxolane) for enhancement of percutaneous absorption was under evaluation. SEPA does not have chromophore for either ultraviolet or fluorescence detection using liquid chromatography and has no functional groups for derivatization. Therefore, a direct gas-chromatographic method with flame-ionization detection (GC-FID) was developed. Owing to the limited detection response of the FID detection, it needs a selective and concentrated extract for GC-FID analysis to improve the assay sensitivity to meet the requirement for pharmacokinetic evaluation after topical application. In addition, SEPA is a very volatile compound. Any extraction procedures involving evaporation will result in a poor recovery. The application of solid-phase extraction (SPE) makes it possible to achieve a selective and a 10-fold concentrated extract with an absolute extraction recovery of approximately 90%, which greatly improved the assay sensitivity. This method involved the extraction of SEPA and the internal standard (2-n-heptyl-1,3-dioxolane) from serum (0.1-1 ml) with 100 microliter of hexane-chloroform (1:1, v:v) using a 50 mg 1.0 ml-1 phenyl SPE column (Varian, Harbor City, CA, USA), followed by direct GC-FID analysis on a fused-silica column chemically bonded with cross-linked methyl silicone gum phase (Hewlett Packard Ultra-1, 12 m x 0.2 mm x 0.33 micron, Avondale, PA, USA). The assay demonstrated a lower limit of quantitation of 2.5 ng ml-1 and a linear range of 2.5 to 250 ng ml-1 with intra- and inter-assay precision and accuracy of < or = 10%.

Absorption↗

Development of a novel solid phase extraction method for the analysis of bacterial quinones in activated sludge with a higher reliability.

A novel analytical method for analysis of microbial quinones in activated sludge sample was developed with improved reliability compared to the conventional method. The operating conditions for the extraction of quinones from activated sludge sample with a methanol-chloroform mixture and hexane were optimized. A solid phase extraction method using the Sep-Pak Plus Silica, a small column packed with silica gel, was employed for the purification and separation of quinones instead of column chromatography and thin layer column chromatography used in the conventional method. The analytical operation was simplified and the analytical time was shortened by a half or two-thirds of that required for the conventional method. The recoveries of quinones were markedly increased from 30-60% with the conventional method to as high as 90-101% with the improved method, demonstrating that the reliability of the analytical results of the improved method is significantly higher than that of the conventional method. The quinone content value obtained using the improved method was twice as high as that obtained using the conventional method for the same activated sludge sample, but the quinone profiles expressed as the mole fraction of each quinone type were the same for each method.

Journal Article↗

Analysis of the active lactone form of 9-aminocamptothecin in plasma using solid-phase extraction and high-performance liquid chromatography.

We have developed a sensitive HPLC assay to quantitate the active lactone form of 9-aminocamptothecin (9AC) in human plasma over the concentration range 10-0.25 nM (0.091 ng/ml). Solid-phase extraction separated 9AC lactone from its less active metabolite, 9AC carboxylate, allowing samples to be stored for up to two months prior to reversed-phase HPLC analysis. An acidic (pH 2.55) isocratic HPLC mobile phase was used to enhance 9AC fluorescence resulting in an over 50-fold increase in assay sensitivity compared to previous methods. This assay was able to measure steady-state 9AC lactone concentrations even at the lowest dose level of 9AC used in our Phase I clinical trial.

Antineoplastic Agents↗

Determination of phenprocoumon, warfarin and their monohydroxylated metabolites in human plasma and urine by liquid chromatography-mass spectrometry after solid-phase extraction.

A high-performance liquid chromatography-mass spectrometry (HPLC-MS) method for the quantification of phenprocoumon, warfarin, and their known monohydroxylated metabolites in human plasma and urine was developed using a simple, selective solid-phase extraction scheme. Chromatographic separation was achieved on a reversed-phase Luna C18 column and step gradient elution resulted in a total run time of about 13 min. Limits of quantification (LOQ) were < or = 40 nM for the parent compounds and < or = 25 nM for the metabolites and the limit of detection (LOD) was < or = 2.5 nM for all analytes. Average recovery was 84% (+/- 3.7) and 74% (+/- 13.2) in plasma and urine, respectively. Intra- and inter-day coefficients of variation were < or = 8.6 and < or = 10.6% in plasma and urine, respectively. The method was successfully applied to the analysis of phenprocoumon samples from four healthy volunteers and should prove useful for future comparative studies of warfarin and phenprocoumon pharmacokinetics.

Anticoagulants↗

High-performance liquid chromatography method for the quantification of rabeprazole in human plasma using solid-phase extraction.

A simple, sensitive and selective HPLC method with UV detection (284 nm) was developed and validated for quantitation of rabeprazole in human plasma, the newest addition to the group of proton-pump inhibitors. Following solid-phase extraction using Waters Oasistrade mark SPE cartridges, the analyte and internal standard (Pantoprazole) were separated using an isocratic mobile phase of 5 mM ammonium acetate buffer (pH adjusted to 7.4 with sodium hydroxide solution)/acetonitrile/methanol (45/20/35, v/v) on reverse phase Waters symmetry C(18) column. The lower limit of quantitation was 20 ng/mL, with a relative standard deviation of less than 8%. A linear range of 20-1000 ng/mL was established. This HPLC method was validated with between- and within-batch precision of 2.4-7.2% and 2.2-7.3%, respectively. The between- and within-batch bias was -1.7 to 2.6% and -2.6 to 2.1%, respectively. Frequently coadministered drugs did not interfere with the described methodology. Stability of rabeprazole in plasma was excellent, with no evidence of degradation during sample processing (autosampler) and 3 months storage in a freezer. This validated method is sensitive, simple and repeatable enough to be used in pharmacokinetic studies.

2-Pyridinylmethylsulfinylbenzimidazoles↗

Development and validation of a bioanalytical method using automated solid-phase extraction and LC-UV for the simultaneous determination of lumefantrine and its desbutyl metabolite in plasma.

A bioanalytical method for the determination of lumefantrine (LF) and its metabolite desbutyl-lumefantrine (DLF) in plasma by solid-phase extraction (SPE) and liquid chromatography has been developed. Plasma proteins were precipitated with acetonitrile:acetic acid (99:1, v/v) containing a DLF analogue internal standard before being loaded onto a octylsilica (3 M Empore) SPE column. Two different DLF analogues were evaluated as internal standards. The compounds were analysed by liquid chromatography UV detection on a SB-CN (250 mm x 4.6 mm) column with a mobile phase containing acetonitrile-sodium phosphate buffer pH (2.0; 0.1 M) (55:45, v/v) and sodium perchlorate 0.05 M. Different SPE columns were evaluated during method development to optimise reproducibility and recovery for LF, DLF and the two different DLF analogues. The within-day precisions for LF were 6.6 and 2.1% at 0.042 and 8.02 microg/mL, respectively, and for DLF 4.5 and 1.5% at 0.039 and 0.777 microg/mL, respectively. The between-day precisions for LF were 12.0 and 2.9% at 0.042 and 8.02 microg/mL, respectively, while for DLF 0.7 and 1.2% at 0.039 and 0.777 microg/mL, respectively. The limit of quantification was 0.024 and 0.021 microg/mL for LF and DLF, respectively. Different amounts of lipids in plasma did not affect the absolute recovery of LF or DLF.

Chromatography, Liquid↗

New method for rapid solid-phase extraction of large-volume water samples and its application to non-target screening of North Sea water for organic contaminants by gas chromatography-mass spectrometry.

A method has been developed that allows the solid-phase extraction of microorganic compounds from large volumes of water (10 l) for non-target analysis of filtered seawater. The filtration-extraction system is operated with glass fibre filter candles and the polymeric styrene-divinylbenzene sorbent SDB-1 at flow-rates as high as 500 ml/min. Recovery studies carried out for a couple of model substances covering a wide range of polarity and chemical classes revealed a good performance of the method. Especially for polar compounds (log Kow 3.3-0.7) quantitative recovery was achieved. Limits of detection were between 0.1 and 0.7 ng/l in the full scan mode of the MS. The suitability of the method for the analysis of marine water samples is demonstrated by the non-target screening of water from the German Bight for the presence of organic contaminants. In the course of this screening a large variety of substances was identified including pesticides, industrial chemicals and pharmaceuticals. For some of the identified compounds their occurrence in marine ecosystems has not been reported before, such as dichloropyridines, carbamazepine, propyphenazone and caffeine.

Gas Chromatography-Mass Spectrometry↗

Analysis of pesticide residues in wine by solid-phase extraction and gas chromatography with electron capture and nitrogen-phosphorus detection.

A feasible and reproducible method for multiresidue analysis of several common pesticides, of different polarities, in wine samples is proposed. The method combines a solid-phase extraction on polymeric cartridges eluted with ethyl acetate and a gas chromatographic determination using electron capture and nitrogen-phosphorus detection. To avoid the matrix effect, previous washing of the cartridges with a mixture of water-2-propanol (90:10) and further clean-up of the extract on Florisil cartridges, together with a calibration using spiked extracts, are recommended.

Chromatography, Gas↗

Determination of cefotaxime and desacetylcefotaxime in cerebrospinal fluid by solid-phase extraction and high-performance liquid chromatography.

A high-performance liquid chromatographic procedure has been developed for the measurement of cefotaxime and desacetylcefotaxime in cerebrospinal fluid. Both compounds were isolated from cerebrospinal fluid samples using solid-phase extraction (SPE). LiChrolut RP-18 (200 mg; 3 ml) columns and a mixture of methanol-phosphate buffer pH 7 (1:1) were applied to elute cefotaxime and its desacetyl metabolite. The separation was performed on a LiChrospher 100RP-18 (5 microm; 250 x 4 mm I.D.) column. The mobile phase consisted of 0.01 M acetate buffer pH 4.8-methanol (85:15), flow-rate was 1.5 ml/min. Cefotaxime and desacetylcefotaxime were detected at a wavelength of 254 nm by UV-Vis detector. The range of concentrations for method calibration and for analytical studies was 1.56-100 microg/ml. The quantitation limit in cerebrospinal fluid was 0.39 microg/ml for cefotaxime and 0.78 microg/ml for desacetylcefotaxime. The extraction recovery from cerebrospinal fluid spiked with cefotaxime and desacetylcefotaxime was 90.4-100.1% and 97.4-102.9%, respectively. The RSDs were below 10.7% for cefotaxime and 6.8% for desacetylcefotaxime. The developed SPE-HPLC method was applied for cefotaxime and desacetylcefotaxime determination in cerebrospinal fluid of children with hydrocephalus after intraventricular administration.

Calibration↗

Preparation of a molecularly imprinted polymer for the solid-phase extraction of scopolamine with hyoscyamine as a dummy template molecule.

Molecularly imprinted polymers (MIPs) selective for scopolamine were produced using hyoscyamine (a close structural analogue) as template molecule. The produced polymers were used as media for solid-phase extraction, exhibiting selective binding properties for the analyte from biological samples. Human and calf urine and serum were processed on the MIP under various extraction protocols. The best performance was observed after loading the analyte in aqueous environment facilitating retention on the MIP by non-selective hydrophobic interactions. The MIPs were subsequently washed using an optimised solvent system to enable selective desorption of the analyte. Other related and non-related compounds were accessed to evaluate molecular recognition properties. Recoveries of up to 79% were achieved for the analyte of interest from biological samples.

Animals↗

Pyrrole-based conductive polymer as the solid-phase extraction medium for the preconcentration of environmental pollutants in water samples followed by gas chromatography with flame ionization and mass spectrometry detection.

A pyrrole-based polymer was synthesized and applied as a new sorbent for solid-phase extraction (SPE) of some environmental pollutants from water samples. Polypyrrole (PPy) was synthesized by chemical oxidation of the monomer in nonaqueous solution. SPE of selected phenols, pesticides, and polyaromatic hydrocarbons (PAHs) from aqueous samples were performed using 200 mg PPy. The determination was subsequently carried out by gas chromatography-flame ionization detection (GC-FID) and gas chromatography-mass spectrometry (GC-MS). The polymer showed much higher recoveries for aromatic compounds than aliphatics. Preconcentration of sample volumes up 11 led to acceptable recoveries for aromatic and other tested polar compounds. The R.S.D. for a river water sample spiked with phenols, pesticides and PAHs at sub-ppb level was lower than 10% (n = 3) and limits of detection for these compounds were between 15 and 120 ng l(-1).

Gas Chromatography-Mass Spectrometry↗

Fast screening for drugs of abuse by solid-phase extraction combined with flow-injection ionspray-tandem mass spectrometry.

A fast analytical approach for the simultaneous quantitative screening for illicit drugs in serum and urine without tedious chromatographic separation steps was developed by combining solid-phase extraction (SPE) followed by flow-injection analysis (FIA) with ionspray-ionization and tandem mass spectrometry (MS-MS) detection using a PE Sciex API 300 triple-quadrupole MS. MS-MS analysis was performed by sequentially isolating the precursor ions of the analytes and their deuterated standards with subsequent fragmentation and monitoring of one fragment ion for each substance. A multiple-reaction monitoring experiment was set up for morphine (MO), codeine (COD), amphetamine (AMP), benzoylecgonine (BZE), and their deuterated analogues. For method evaluation, serum samples spiked with 2-1000 ng of each drug and deuterated standards were extracted by mixed-mode SPE, redissolved in CH3CN-NH4OAc-buffer, and directly injected by flow injection into the ionspray source. The specificity of this new method was demonstrated by testing compounds with similar chemical structure for interferences from the analytes of interest (e.g., dihydromorphone, morphine glucuronide, and 6-monoacetylmorphine with MO; dihydrocodeine and hydrocodone with COD; cocaine [COC] and ecgonine methylester with BZE; methamphetamine with AMP). The possibility of interferences of such compounds with the FIA-ionspray-MS-MS screening method is discussed. Spiked serum samples and serum and urine samples from drug addicts and victims of drug abuse were analyzed with FIA-MS-MS and, after derivatization, with gas chromatography-mass spectrometry (GC-MS). Comparable quantitative results were obtained with both methods; no interferences with metabolites or other compounds were found. The FIA-ionspray-MS-MS method is a fast, quantitative, sensitive, and highly specific alternative method to drug-screening by immunoassays, high-performance liquid chromatography, and GC-MS. It can be used for the simultaneous detection of different drugs and metabolites such as opiates, COC, AMP derivatives, and many other drugs.

Chromatography, Gas↗

Confirmation of amphetamine, methamphetamine, MDA and MDMA in urine samples using disk solid-phase extraction and gas chromatography-mass spectrometry after immunoassay screening.

A method using mixed phase disk solid-phase extraction (SPE) and gas chromatography-mass spectrometry (GC-MS) was developed for confirmation of amphetamine (AMP), methamphetamine (MET), 3,4-methylenedioxyamphetamine (MDA) and 3,4-methylenedioxymethamphetamine (MDMA) in urine samples after immunoassay screening. Disk SPE provided hydrophobic (C(18)) and strong cation-exchange (SCX) interactions. The analytes were retained on SCX functional groups in the disk and eluted with ammoniated ethyl acetate after washed with methanol. Confirmation and quantitation was exercised by selected ion monitoring using nikethamide as chromatographic standard. Recoveries of the amphetamines were between 73.0 and 104.6% with RSDs in range of 2.1-6.4% (n=3). The limits of detection were 2 ng/ml for AMP, MET and MDMA, and 4 ng/ml for MDA. Five real urine samples were tested with the method after immunoassay screening, and the results were comparable to those of traditional liquid-liquid extraction (LLE). The method was solvent-saved, simple, rapid and reliable, and the extract was cleaner than that of LLE.

3,4-Methylenedioxyamphetamine↗

Rapid multiresidue determination of organochlorine and organophosphorus compounds in human serum by solid-phase extraction and gas chromatography coupled to tandem mass spectrometry.

A rapid analytical method for the multiresidue determination of several organochlorine and organophosphorus pesticides and polychlorinated biphenyls in human serum samples has been developed. Analytes were isolated by solid-phase extraction using C18 cartridges with subsequent analysis by GC-MS/MS using a glass liner packed with CarboFrit in the GC injection port. Labelled surrogate internal standards (fenitrothion D6, HCB (13)C6, p, p'-DDE D8 and PCB 138 (13)C12) were added to the samples before the extraction and were used for quantitation and for quality control in the analysis of real-world samples. Accuracy and precision were evaluated by using serum samples fortified at two concentration levels for the three families of compounds, with satisfactory results in the majority of cases. The high selectivity and sensitivity of GC-MS/MS allowed low detection limits of 0.05-0.5 ng mL(-1) for most of the analytes investigated. The developed procedure improves other current methodologies for the analysis of pesticides and PCBs in biological fluids, especially as regards to analysis time and simplicity of sample treatment. The method was applied to several serum samples obtained from farmers devoted to citrus crop production. Chlorpyrifos, HCB, p, p'-DDE and the higher chlorinated PCBs (153, 138 and 180) were the most frequently detected compounds.

Gas Chromatography-Mass Spectrometry↗

Simultaneous determination of selected endocrine disrupters (pesticides, phenols and phthalates) in water by in-field solid-phase extraction (SPE) using the prototype PROFEXS followed by on-line SPE (PROSPEKT) and analysis by liquid chromatography-atmospheric pressure chemical ionisation-mass spectrometry.

In this study, a new procedure, based on on-line solid-phase extraction (SPE) and analysis by liquid-chromatography-atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS), has been developed for the simultaneous, multianalyte determination of 21 selected pesticides, phenols and phthalates in water. SPE was carried out on polymeric PLRP-s cartridges by percolating 20 mL-samples. For sample preconcentration, the performance of a prototype programmable field extraction system (PROFEXS) was evaluated against the commercial laboratory bench Prospekt system used for method development. The Profexs is designed for the automated on-site sampling, SPE preconcentration, and storage of up to 16 samples in SPE cartridges. These cartridges are further eluted and on-line analyzed with the Prospekt coupled to the chromatographic system. In the optimized method, where completely on-line SPE-LC-MS analysis of the samples is carried out with the Prospekt in the laboratory, detection limits lower than 100 ng/L, and satisfactory precision (relative standard deviations <25%) and accuracies (recovery percentages >75%) were obtained for most investigated compounds from the analysis of spiked Milli-Q water. The extraction efficiency achieved with the Profexs was comparable to that of the Prospekt for most compounds and somewhat lower for the most apolar analytes, probably due to adsorption on the pump filters. The completely on-line optimized method was applied to the analysis of surface water, ground water and drinking water from a waterworks in Barcelona. Some pesticides and phenols were found in both surface water and groundwater at ng/L or microg/L levels, but not in the final drinking water. Di(2-ethylhexyl)phthalate (DEHP) was present in all samples investigated, including blanks. To the author's knowledge, this is the first work describing the application of a fully automated on-line SPE-LC-MS method for the simultaneous analysis of pesticides, phenols, and phthalates in water, and the second one that examines the possibilities of the prototype Profexs for automated on-site SPE preconcentration of organic pollutants from water samples.

Atmospheric Pressure↗

Liquid chromatographic determination of cyclosporin A in serum with use of a solid-phase extraction. Comparison between high-performance liquid chromatography and radioimmunoassay levels in clinical investigations.

A simple reliable liquid chromatographic method for assay of cyclosporin A in serum or urine is described. Samples were cleaned up on a solid-phase extraction system (cyanopropyl column). The system involved a reversed-phase C18 Ultrasphere column maintained at 72 degrees C and an acetonitrile linear gradient (65 to 95%) in 0.14% triethylammonium phosphate. Liquid chromatographic analysis of radioimmunoassay standards shows that some samples contain a contaminant peak. Comparison of cyclosporin A levels obtained by radioimmunoassay and high-performance liquid chromatography in clinical investigations show that the former values are generally, but not always, higher than the latter, and that cyclosporin A is very differently metabolized depending on the patient, disease and treatment.

Adolescent↗

Determination of terfenadine and terfenadine acid metabolite in plasma using solid-phase extraction and high-performance liquid chromatography with fluorescence detection.

This work describes the methodology for the analysis of terfenadine and the acid metabolite of terfenadine in plasma using high-performance liquid chromatography. The use of solid-phase extraction allows the use of robotic or manual sample preparation for the efficient clean-up of terfenadine and terfenadine acid metabolite from plasma. Additional selectivity is obtained through the use of fluorescence detection. For terfenadine, the validated quantitation range of this method is 10.0-84.2 ng/ml with coefficients of variation of 5.7-30%. For terfenadine acid metabolite, the validated quantitation range of this method is 8.2-500 ng/ml with coefficients of variation of 4.1-24%.

Chromatography, High Pressure Liquid↗

Simultaneous solid-phase extraction and chromatographic analysis of morphine and hydromorphone in plasma by high-performance liquid chromatography with electrochemical detection.

High-performance liquid chromatography has become an important analytical tool for the quantitation of opioid drugs. Using solid-phase extraction and coulometric electrochemical detection, we have developed a chromatographic method for the simultaneous measurement of morphine and hydromorphone which is both sensitive and specific. Using 1 ml of plasma, intra-assay and inter-assay data show that the detection limit for accurate quantitation of these compounds is about 1.2 ng/ml (coefficient of variation 11.6%) for morphine and 2.5 ng/ml (coefficient of variation 10.5%) for hydromorphone. The method is simple and readily adaptable to most pharmacokinetic studies and toxic screens involving these drugs.

Chromatography, High Pressure Liquid↗