Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “RADIOGRAPHY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58Linked to original sources

Maximizing film contrast for scanning equalization radiography.

The results of a numerical simulation indicate that scanning equalization radiography (SER) provides the opportunity to use film/screen combinations of significantly higher contrast than currently practical in conventional chest radiography. These calculations which attempt to maximize overall image contrast while minimizing areas of over and under exposure demonstrate that optimum film gradient varies inversely with scanning beam area. Furthermore, we show that in an SER system which we have optimized for chest imaging that the peak film gamma gradient can be increased from that typical of conventional films (3.0-3.5) to approximately 7 with advantage.

Computer Simulation↗

Comparison of the low-contrast detectability of a screen-film system and third generation computed radiography.

Contrast-detail (CD) analysis was used to compare the low-contrast detectability of computed radiography (CR) and screen-film (SF) as applied to the task of adult chest radiography. A phantom was constructed and imaged using the same exposure factors throughout all experiments. Within-observer variance, between-observer variance, and image sample variance were calculated and used to estimate the standard error for each experiment. The results of these CD experiments agreed with the predictions of the Rose model. Observers performed equally well for low-contrast target detection using CR and SF.

Adult↗

Rotary scanning equalization radiography: an efficient geometry for equalization mammography.

The detection of cancer in the radiographically dense breast is problematic, since the breast will produce a range of exposure that exceeds the useful dynamic range of high contrast film-screen combinations. It has been shown previously that mammographic scanning equalization radiography (MSER) can be used to overcome the latitude limitations of film-screen mammography. However, the tube loading of MSER is orders of magnitude greater than conventional mammography. A new rotary geometry for equalization radiography is proposed, in which the image receptor is exposed by repeated scans of a modulated slot beam, oriented at a variety of scanning angles with respect to the object. The superposition of the exposure from appropriately modulated, rotated slot beams produces an entrance exposure that will effectively equalize the film exposure. The principle advantages of this geometry is its simplicity and reduced tube loading. To determine the effectiveness and feasibility of RSER the effect of conventional, MSER, and RSER have been numerically simulated on the appearance of clinical mammograms, the relative heat loading, and the fraction of the breast imaged with high contrast are calculated. It is found that RSER produces images that are free of artefacts, and exhibit a similar degree of equalization, as found in MSER images. RSER accomplishes this with only four scanning angles, and a beam that is approximately 4 cm wide. The resulting tube loading is only three times greater than that found in conventional imaging. Numerical simulations indicate that RSER is a simple, feasible means of overcoming the latitude limitations of film-screen mammography.

Computer Simulation↗

Evaluation of an asymmetric screen-film system for chest radiography.

To evaluate the potential utility of an asymmetric screen-film system for chest radiography, its image quality and detail visibility compared with a conventional screen-film system are investigated. The basic imaging properties were evaluated by measuring Hurter and Driffield curves, resolution properties, and noise Wiener spectra. The visibility of simulated anatomical and pathological details in radiographs of a chest phantom and normal anatomy in chest radiographs of patients were evaluated subjectively. The dynamic range of each system is comparable, though the asymmetric screen-film system can provide an advantage over the conventional system due to a relative dose reduction of approximately 35% and higher resolution properties at high optical densities. The noise level of the asymmetric screen-film system is slightly greater at low optical densities and much greater at high optical densities. However, the visibility of lung details with the asymmetric screen-film system is slightly superior to the conventional screen-film system despite the increase in noise. Mediastinal and retrodiaphragmatic details are similar, though marginally superior with the asymmetric screen-film system. It is concluded that the asymmetric screen-film system provided slightly superior image quality to the conventional screen-film system for chest radiography, provided the average lung density is maintained at a higher level than is customary with conventional systems.

Biophysical Phenomena↗

Scatter compensation in digital chest radiography using the posterior beam stop technique.

A new scatter compensation technique for computed radiography based on posterior beam stop (PBS) sampled scatter measurements and the bicubic spline interpolation technique was proposed. Using only a single exposure, both the clinical image and an array of scatter measurements, which were interpolated into a smooth scatter-only image, were simultaneously acquired. The scatter was subtracted from the clinical image to generate the primary-only image. To gauge the accuracy of scatter estimation, both quantitative and interpolation errors were evaluated. The PBS measurements were compared against the standard beam stop method at 16 locations in an anatomical phantom, resulting in quantitative errors of 2.7% relative to the scatter or 6.8% relative to the primary. Also measured were the interpolation error over 64 interpolation sample locations and 64 midpoint sample locations in the anatomical phantom. The combined interpolation error was 1.9% relative to the scatter or 8.0% relative to the primary. At the interpolation sample locations, the errors were identical between the phantom radiograph and digital portable chest radiographs from five patients. By summing the quantitative and interpolation errors in quadrature, the overall error of the PBS SISTER (scatter interpolation-subtraction technique for radiography) method was 3.3% relative to the scatter or 10% relative to the primary, which was adequate for dual-energy imaging purposes (less than 10% error relative to the scatter or 20% relative to the primary). The change of image contrast, noise, and signal-to-noise ratio (SNR) at six locations in the anatomical phantom were quantitatively analyzed. Contrast and noise were equally enhanced in all anatomical regions, resulting in approximately the same SNR before and after compensation.(ABSTRACT TRUNCATED AT 250 WORDS)

Algorithms↗

A comprehensive physical image quality evaluation of a selenium based digital x-ray imaging system for thorax radiography.

A selenium based digital x-ray system dedicated to chest radiography has been installed by the UK Department of Health's Medical Devices Agency at Leeds General Infirmary, UK, to undergo a comprehensive evaluation, including the physical image quality. The underlying characteristics which define the overall image quality of a system are the following: sensitometric response, modulation transfer function, and noise power spectrum. These have been measured objectively on preprocessed digital data acquired under relevant radiographic conditions. The image data is further processed prior to hard copy display. The displayed image quality may only be measured subjectively; threshold contrast detail detectability is such a measure which can be related to the objective measures of image quality. The objective imaging characteristics suggest that Thoravision has a significant advantage over conventional radiography imaging systems. However, subjective measures have demonstrated that the image processing can have a significant effect on the perceived image quality. Thoravision has the potential to deliver a significantly improved image quality to clinicians with no increase in radiation exposure to the patient, or image quality may be maintained with a reduction in radiation exposure. Digital image processing is central to the efficiency with which it achieves this.

Biophysical Phenomena↗

A clinical tool to determine the necessity of spine radiography in postmenopausal women with osteoporosis presenting with back pain.

BACKGROUND: Vertebral fractures are underdiagnosed, although the resulting mortality and morbidity in postmenopausal women with osteoporosis is now recognised. In a population of postmenopausal women with osteoporosis and back pain, symptoms may be related to vertebral fractures or degenerative changes of the spine. AIM: To evaluate a population of postmenopausal women presenting with back pain and factors associated with vertebral fractures which were assessable in a clinical setting in order to determine the necessity for spine radiography. METHODS: Patient questioning and physical examination were carried out and spinal radiographic data collected from 410 postmenopausal women with osteoporosis, with an average age of 74 years, who consulted a rheumatologist for back pain. Of these, 215 (52.4%) patients were diagnosed with at least one vertebral fracture. Logistic regression was used to identify the most relevant clinical features associated with existing vertebral fractures, and to derive a quantitative index of risk. RESULTS: The model included six parameters: age, back pain intensity, height loss, history of low trauma non-vertebral fractures, thoracic localisation of back pain and sudden occurrence of back pain. The scoring system, or the quantitative index, had a maximal score of 16. For a score >or=7, the probability of existing vertebral fracture was >or=43%. The correlation between this quantitative index and the logistic model probability was 0.98, suggesting an excellent and highly significant approximation of the original prediction equation. CONCLUSIONS: From six clinical items, an index was built to identify women with osteoporosis and back pain who should have spine radiography. This simple tool may help clinicians to optimise vertebral fracture diagnosis and to make a proper therapeutic decision.

Aged↗

Can the use of radiography of arms and legs in accident and emergency units be made more efficient?

The efficiency of the selection of patients with injured arms and legs for radiography was investigated. The analysis was based on data on presenting signs and symptoms collected in a multicentre study organised by the Royal College of Radiologists working party on the effective use of diagnostic radiology. The work was carried out in eight accident and emergency units in England and Wales. With the help of various computer simulation techniques a combination of signs and symptoms that might usefully improve present practice was sought. The results suggest that for injuries of arms and legs the clinical determinants of bony injury cannot be refined further to improve current selection for radiography. This study shows that existing clinical practice is probably as good as it can be.

Accidents↗

Positioning long lines: contrast versus plain radiography.

AIM: To assess the value of contrast versus plain radiography in determining radio-opaque long line tip position in neonates. METHODS: In a prospective study, plain radiography was performed after insertion of radio-opaque long lines. If the line tip was not visible on the plain film, a second film with contrast was obtained in an attempt to visualise the tip. RESULTS: Sixty eight lines were inserted during the study period, 62 of which were included in the study. In 31, a second radiographic examination with contrast was necessary to determine position of the tip. In 29 of these, the line tip was clearly visualised with contrast. On two occasions, the line tip could not be seen because the contrast had filled the vein and obscured the tip from view. Eight of the lines that required a second radiograph with contrast were repositioned. CONCLUSION: Intravenous contrast should be routinely used in the assessment of long line position in the neonate.

Catheterization, Central Venous↗

Diagnostic value of radiography in cases of perinatal death: a population based study.

OBJECTIVE: To examine the yield of radiographic abnormalities in a population based set of perinatal deaths, the diagnostic value of whole body postmortem radiographs in the same set, and previous factors that may increase the proportion of useful examinations. DESIGN: Retrospective population based study. SETTING: A region of Norway. PATIENTS: All infants from a well defined geographical area who were stillborn or had died soon after birth over an 11 year period (n=542), who had routinely undergone whole body radiography and autopsy. MAIN OUTCOME MEASURES: (a) Proportion of cases with abnormal radiographic findings. (b) Proportion of abnormal radiographs providing new information that was useful for postmortem diagnosis. RESULTS: Radiographs were abnormal in 162/542 cases (30%). These provided new information about, but did not help to confirm, the pathological process leading to death in 14/162 (8.6%), may have helped to confirm, but not establish, the cause(s) of death in 1/162 (0.6%), and were of vital importance for establishing the cause(s) of death in 5/162 (3.1%). Among infants with external malformations, the proportion of useful radiographs was 12/100 (12%), and among the remainder it was 8/436 (1.8%), a difference of 10.2% (95% confidence interval 3.7% to 16.7%; data missing for six cases). CONCLUSIONS: The diagnostic value of postmortem radiography in this population based set was low. However, radiographic findings were of vital importance for establishing the cause(s) of death in 5/542 cases (0.9%).

Autopsy↗

Accuracy of postmortem radiography of excised air-inflated human lungs in assessment of pulmonary emphysema.

The accuracy of radiography of excised air-inflated lungs in assessing pulmonary emphysema at necropsy was evaluated in a series of 107 adults who had died in hospital by reading the radiographs and examining the pathological specimens independently. The radiographic and pathological assessments of the severity of emphysema correlated significantly (r = 0.87, p less than 0.0001). Mild emphysema was recognised radiographically in 88.7% and moderate in 94.9% of the lungs. One of 16 normal lungs (6.3%) was radiographically diagnosed as showing mild emphysema. Six out of 53 lungs (11.3%) with mild emphysema were radiographically assessed as normal. The correct radiographic recognition of the type of emphysema was possible in 86% of lungs with mild and 97.4% with moderate centrilobular emphysema and in 81.8% and 87.5% respectively of the lungs with mild and moderate paracicatricial emphysema, but in only 25.0% and 28.6% of the lungs with mild and moderate panlobular emphysema. Radiographical diagnosis of centrilobular and paracicatricial emphysema was verified pathologically in all lungs showing mild emphysema, but that of panlobular emphysema in only 66.7%. Radiography of excised air-inflated lungs is a rapid, convenient, and reliable method of recognising and assessing the severity of appreciable degrees of centrilobular and paracicatricial emphysema, but less reliable in recognising panlobular emphysema. After the procedure the specimen remains available for almost any other technique.

Adult↗

Prospective study of the yield of physical examination compared with chest radiography in penetrating thoracic trauma.

A prospective study was conducted on 102 patients (84 male), with a median age of 27 years, who had sustained a penetrating chest wound to evaluate the ability of physical examination in comparison with chest radiography to determine management of these injuries. Knife wounds accounted for 92% of the injuries. Fifty three patients had a small collection of air or fluid in their pleural cavity that was not drained. Fifty six hemithoraces had a large collection of fluid or air and were treated by tube thoracostomy. Physical examination at presentation detected large collections of air and fluid correctly and predicted appropriate management (sensitivity 96%, specificity 94%). Residual collections of air or fluid or both were also predicted correctly by clinical examination. Seven small collections increased in size and required intubation. Routine pre-extubation radiographs were found to be of little value in management and their routine use is not recommended. Four patients required late thoracotomy for decortication. By using a policy of selective intubation, frequent clinical reassessment, and chest radiography when relevant, experienced trauma surgeons can manage most penetrating pleural injuries with an acceptably low complication rate.

Adolescent↗

Porcine atrophic rhinitis: snout radiography as an aid to diagnosis and detection of the disease.

Snout radiography is a useful and practicable aid to the diagnosis of atrophic rhinitis. It is also a fairly reliable means of detecting and measuring turbinate atrophy and distortion of the septum nasi in the live pig. Suitable physical and pharmacological methods of restraining pigs for snout radiography are described and guide lines for producing satisfactory, standard snout radiographs are given. Parameters and criteria are recommended for qualitative and quantitative methods of interpreting snout radiographs. The quantitative scoring system approximates the macroscopic post mortem snout scoring system generally employed in Britain and provides data which might be used in genetic or other control programmes. Radiographic standards are tentatively suggested for certifying pigs free from gross lesions of atrophic rhinitis for sale or export purposes.

Anesthesia, General↗

Association between extrinsic and intrinsic carpal ligament injuries at MR arthrography and carpal instability at radiography: initial observations.

PURPOSE: To retrospectively compare the presence or absence of carpal instability on radiographs with the findings of magnetic resonance (MR) arthrographic evaluation of intrinsic and extrinsic ligament tears in patients with chronic wrist pain. MATERIALS AND METHODS: The institutional review board approved this study and did not require informed consent. Signs of carpal instability were assessed on static and dynamic radiographs of the wrist obtained in 72 patients (24 female, 48 male; mean age, 36 years; age range, 14-59 years) with posttraumatic wrist pain. MR arthrography was subsequently performed. Two musculoskeletal radiologists independently analyzed the radiographs and MR images. Each intrinsic and extrinsic ligament was individually evaluated for the presence of a ligament tear. The extent of the tear also was recorded. Interobserver agreement regarding MR arthrographic findings was tested by calculating kappa statistics. Statistical comparison between radiography and MR arthrography was performed by using the Fisher exact test. RESULTS: Twenty-five triangular fibrocartilage complex, 18 (five partial, 13 complete) scapholunate ligament, and 25 (10 partial, 15 complete) lunotriquetral ligament tears were visualized. Twenty-two (all complete) extrinsic ligament tears were detected: two radial collateral ligament, 10 radioscaphocapitate ligament, and 10 radiolunotriquetral ligament tears. Interobserver agreement regarding intrinsic and extrinsic ligament tear detection at MR arthrography was excellent (kappa = 0.80). Nineteen patients had evidence of carpal instability on radiographs. Fourteen (52%) of 27 patients with at least one complete intrinsic lesion had no sign of carpal instability. On the other hand, the association of scapholunate ligament and/or lunotriquetral ligament and extrinsic ligament tears was significantly correlated (P < .001) with carpal instability at radiography. CONCLUSION: The presence or absence of carpal instability on radiographs depends on the association between intrinsic and extrinsic ligament tears-even partial ones-rather than on the presence of intrinsic ligament tears alone, even when the tears are complete.

Adolescent↗

The sensitivity of radiography of the postoperative stomach.

The results of radiology and endoscopy were compared in 140 patients who had undergone gastric surgery for ulcer disease. Of 74 patients who were examined with single-contrast radiography, 37 had abnormalities that were demonstrated endoscopically. The radiographic sensitivities in these patients were: gastritis 2/22 (9%); ulcer 3/5 (60%); obstruction 8/8 (100%); and miscellaneous abnormalities 2/2 (100%). The predictive accuracy of a diagnosis of ulcer was 38%. Of the 66 patients who were examined with double-contrast radiography, 33 abnormalities were found with endoscopy. The radiographic sensitivities were: gastritis 3/13 (23%); ulcer 7/10 (70%); obstruction 4/4 (100%); and miscellaneous abnormalities 6/6 (100%). The predictive accuracy of a diagnosis of ulcer was 44%. Radiology appears to be unreliable in diagnosing gastritis and recurrent ulceration in the postoperative stomach. The double-contrast technique does not offer significant improvement over the single-contrast method in evaluating these postoperative problems.

Barium Sulfate↗

The role of single and double-contrast radiography in the diagnosis of reflux esophagitis.

Sixty-seven patients with endoscopically proved esophagitis and 25 patients who had no esophageal disease were examined by double-contrast esophagography, followed by a single-contrast examination. The radiographs were evaluated separately and as a combined examination technique by three independent radiologists in a blind analysis. The respective sensitivities were 77% for the single-contrast examination, 80% for the double-contrast examination, and 88% for the combined examination method with no significant statistical difference (P = 0.05). The sensitivity increased for all methods with an increased severity of esophagitis. False positives more frequently occurred with double-contrast radiography, leading to similar accuracy rates for all methods (74% to 77%). The double-contrast examination technique showed an advantage over single-contrast radiography only if a granular pattern and erosions were the only radiographically detectible features of esophagitis. The use of the combined examination technique is recommended.

Adult↗

Computed radiography utilizing scanning laser stimulated luminescence.

A new system of computed radiography that is based on new concepts and the latest computer technologies has been developed. This system eliminates the drawbacks of conventional screen-film radiography. The basic principle of the system is the conversion of the x-ray energy pattern into digital signals utilizing scanning laser stimulated luminescence (SLSL).

Computers↗