Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Porosity”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58Linked to original sources

Porous akermanite scaffolds for bone tissue engineering: preparation, characterization, and in vitro studies.

The aim of this study was to develop a bioactive, degradable, and cytocompatible akermanite (Ca2MgSi2O7) scaffold with high porosity and pore interconnectivity. In brief, porous akermanite scaffolds were prepared using polymer sponge method. The porosity and corresponding compressive strength were evaluated. The in vitro degradability was investigated by soaking the scaffolds in Ringer's solution. Hydroxyapatite (HAp)-formation ability of akermantite scaffolds in simulated body fluid (SBF) and the effect of ionic products from the scaffolds dissolution on osteoblasts were investigated. In addition, bone marrow stromal cells (BMSC) adhesion and proliferation on the scaffolds were evaluated. Differentiation of the cells was assessed by measuring alkaline phosphatase (ALP) activity. The results showed that akermanite scaffolds possessed 63.5-90.3% of porosity, with a corresponding compressive strength between 1130 and 530 kPa. The weight loss of the scaffolds and ionic content of the Ringer's solution increased with the increase in soaking time, indicating the degradability of scaffolds. HAp was formed on the scaffolds in SBF and the ionic products from akermanite scaffolds dissolution stimulated osteoblasts proliferation, indicating good in vitro bioactivity. Furthermore, BMSC adhered and spread well on akermanite scaffolds and proliferated with the increase in the culture time, and the differentiation rate of osteoblasts on scaffolds was comparable to that on blank culture plate control. Our results suggested that akermanite scaffolds were bioactive, degradable, and cytocompatible, and might be used as bone tissue engineering materials.

Animals↗

Evaluation of machining methods for trabecular metal implants in a rabbit intramedullary osseointegration model.

Implant success is dependent in part on the interaction of the implant with the surrounding tissues. Porous tantalum implants (Trabecular Metal, TM) have been shown to have excellent osseointegration. Machining this material to complex shapes with close tolerances is difficult because of its open structure and the ductile nature of metallic tantalum. Conventional machining results in occlusion of most of the surface porosity by the smearing of soft metal. This study compared TM samples finished by three processing techniques: conventional machining, electrical discharge machining, and nonmachined, "as-prepared." The TM samples were studied in a rabbit distal femoral intramedullary osseointegration model and in cell culture. We assessed the effects of these machining methods at 4, 8, and 12 weeks after implant placement. The finishing technique had a profound effect on the physical presentation of the implant interface: conventional machining reduced surface porosity to 30% compared to bulk porosities in the 70% range. Bone ongrowth was similar in all groups, while bone ingrowth was significantly greater in the nonmachined samples. The resulting mechanical properties of the bone implant-interface were similar in all three groups, with only interface stiffness and interface shear modulus being significantly higher in the machined samples.

Animals↗

Precooling of the femoral canal enhances shear strength at the cement-prosthesis interface and reduces the polymerization temperature.

Preheating of the femoral stem in total hip arthroplasty improves the cement-prosthesis bond by decreasing the interfacial porosity. The main concern, however, is the potential thermal osteonecrosis because of an increased polymerization temperature. In this study, the effects of femoral canal precooling on the characteristics of the cement-stem interface were evaluated in an experimental model for three test conditions: precooling of the femoral canal, preheating of the stem (44 degrees C), and a control in which stems were inserted at room temperature without thermal manipulation of the implant, cement, or bone. Compared to the control group, precooling of the femoral canal and preheating of the stem had similar effects on the cement-stem interface, with greater interfacial shear strength and a reduced porosity. Femoral canal precooling also produced a lower temperature at the cement-bone interface. No difference was found in the ultimate compressive strength of bone cement for the three preparation conditions. Based on this laboratory model, precooling of the femoral canal could improve shear strength and porosity at the stem-cement interface, minimize thermal injury, and maintain the mechanical strength of the cement.

Arthroplasty, Replacement, Hip↗

Enzymatic erosion of bioartificial membranes to control drug delivery.

The preparation of an enzymatic controlled drug release system from blends of PVA/starch/alphaA, in the form of films, is described. It was shown that alphaA hydrolyses the starch within these films, resulting in a time-dependent change of the porosity in the matrix. Films were characterized by calorimetric analysis to study the interactions between the enzyme and the polymeric constituents at the molecular level. The presence of alphaA, in fact, influenced the PVA crystallization in the blends. Release tests and permeability experiments were carried out to evaluate the transport properties of the films. An increase in porosity and permeability was observed by increasing alphaA content (16-28 wt.-%). Films loaded with theophylline and caffeine were also prepared to analyze drug release properties of the matrix. Drug release kinetics were coherent with the measured changes in porosity: at higher alphaA concentrations the amount of released drug increased under the influence of diffusion and erosion processes. The results obtained are promising for the realization of drug delivery devices for a rapid release or for the release of poorly soluble drugs which usually remain entrapped in the matrix.SEM images of a PVA/starch/alphaA film before (A) and after (B) the erosion.

Biocompatible Materials↗

Differential extraction of N-acetylglucosaminidase and trehalase from the cell envelope of Candida albicans.

Dithiothreitol (DTT) extraction of N-acetylglucosaminidase and trehalase from intact Candida albicans ATCC 10261 cells was monitored as an index of cell envelope porosity during N-acetylglucosamine-induced morphogenesis. Trehalase, which is secreted into the cell envelope during starvation and bud-formation, displayed similar extraction kinetics in starved, germ tube-forming, and bud-forming cells, indicating that the mother cell wall remains largely unchanged during morphogenic outgrowth and that the porosity of bud and mother cell walls is similar. N-acetylglucosaminidase, which is secreted specifically during morphogenesis, was released eightfold more rapidly from germ tube-forming than bud-forming cells, reflecting major differences in porosity between bud and germ tube. In addition, by assaying DTT extracts and extracted cell residues, it was found that the total extracellular N-acetylglucosaminidase activity increased 2- to 2.5-fold during DTT treatment. Thus, DTT unmasks a cryptic form of N-acetylglucosaminidase. The cryptic activity was associated with the cell wall fraction.

Acetylglucosaminidase↗

Hepatic sinusoidal endothelium heterogeneity with respect to the recognition of apoptotic cells.

The recognition and removal of human apoptotic peripheral lymphocytes in selected populations of periportal and perivenous endothelial cells was studied in in situ and in vitro experiments. Apoptotic peripheral blood lymphocytes once injected into the liver circulation were retained by the sinusoids showing a large heterogeneity of distribution: apoptotic cells are found in the periportal tract double the amount found in the perivenous region. Apoptotic PBL adhesion was lowered to a sixth of the control after preinjection with a sugar mixture (Mannose, N-acetylgalactosamine, N-acetylglucosamine, D-galactose), as suggested by the expression of modified surface glycoconjugates on the plasma membrane of apoptotic cells. A bimodal profile of the distribution of the hepatic sinusoidal cell population, regarding the number of galactose and mannose receptors and the porosity index, was found. Two endothelial cell subsets were present: low porosity cells (average index 14 +/- 6%; periportal tract) with a high number of carbohydrate binding sites, and high porosity cells (average index 26 +/- 7%; perivenous tract), with a low number of carbohydrate binding sites.

Animals↗

Determination of the Surface Tension of Microporous Membranes Using Contact Angle Measurements

In this paper, a new method of determining the surface tension of the solid material that a microporous membrane is made from is introduced. The method is based on the well known determination of the so-called contact angle that is formed on the solid/liquid/gaseous three phase line. A nonideal state of the solid phase leads to a deviation of the contact angle that can be observed experimentally from the equilibrium angle that arises from the thermodynamically state of lowest energy, as it must be used to calculate the solid surface tension via the Young equation. The deviation caused from the porous structure of the solid material will be taken into account in this work. Doing so, we derived an equation that connects the surface porosity, the measured contact angle, and the equilibrium contact angle. Using this equation, the measured and therefore deviated contact angles can be corrected for the porosity of the solid material, yielding the contact angle observable on a surface made from the same but nonporous material. The equation derived was tested on different microporous membranes made from expanded poly(tetrafluoroethylene). The surface porosity needed was determined using scanning electron microscopy followed by computerized image analysis. Copyright 1997 Academic Press. Copyright 1997Academic Press

Journal Article↗

Electrophoretic Mobility of a Concentrated Suspension of Spherical Particles.

The electrophoretic behavior of concentrated spherical colloidal particles is analyzed theoretically for all levels of scaled surface potential &phi;a, taking the effect of double-layer polarization (DLP) into account. The result of numerical simulation reveals that for a very small kappaa (<0.01), kappa and a being, respectively, the reciprocal Debye length and the particle radius, or a very large kappaa (>100), using a linearized Poisson-Boltzmann equation (PBE) and neglecting the effect of DLP is reasonable; for an intermediate kappaa, appreciable deviation may result. The deviation is negative if kappaa is small, and positive if kappaa is large. The mobility against kappaa curve may have a local minimum and a local maximum. If &phi;a is low, the mobility increases with the porosity of the system under consideration, and for a fixed porosity, the mobility increases with kappaa. If &phi;a is high and kappaa is small, the effect of &phi;a (i.e., solving a nonlinear PBE) on the mobility of a particle is more significant than that of double-layer polarization, and the reverse is true if kappaa is large. For an intermediate kappaa, the effect of DLP is more significant than that of &phi;a when the porosity is high, and the reverse is true if it is low. Copyright 1999 Academic Press.

Journal Article↗

Grand canonical Monte Carlo simulation for determination of optimum parameters for adsorption of supercritical methane in pillared layered pores.

A grand canonical Monte Carlo (GCMC) method is carried out to determine optimum adsorptive storage pressures of supercritical methane in pillared layered pores. In the simulation, the pillared layered pore is modeled by a uniform distribution of pillars between two solid walls. Methane is described as a spherical Lennard-Jones molecule, and Steele's 10-4-3 potential is used for representing the interaction between the fluid and a layered wall. The site-site interaction is also used for calculating the interaction energy between methane molecules and pillars. An effective potential model that reflects the characteristics of a real pillared layered material is proposed here. In the model, a binary interaction parameter, k(fw), is introduced into the combining rule for the cross-energy parameter for the interaction between the fluid and a layered wall. Based on the experimental results for the Zr-pillared material synthesized and characterized by Boksh, Kikkinides, and Yang, the binary interaction parameter, k(fw), is determined by fitting the simulation results to the experimental adsorption data of nitrogen at 77 K. Then, by taking it as a model of pillared layered material, a series of GCMC simulations have been carried out. The excess adsorption isotherms of methane in a pillared layered pore with three different pore widths and porosities are obtained at three supercritical temperatures T=207.3, 237.0, and 266.6 K. Based on the simulation results at different porosities, various pore widths and different supercritical temperatures, the pillared layered pore with porosity psi=0.94 and pore width hsigma(p)=1.02 nm is recommended as adsorption storage material of supercritical methane. Moreover, the optimum adsorption pressure is determined at a given temperature and a fixed width of the pillared layered pore. For example, at temperature T=207.3 K, the optimum adsorption pressures are 3.1, 3.7, and 4.5 M Pa at H=1.02, 1.70, and 2.38 nm, respectively. In summary, the GCMC method is a useful tool for optimizing adsorption storage of supercritical methane in pillared layered material.

Journal Article↗

Videodensitometry of osteons in females with femoral neck fractures.

The medial femoral cortices of 10 females with femoral neck fractures and 10 age-matched female autopsy cases were studied using computer-assisted videodensitometry. Radiographic mineral density was determined using the calibration method described by Martin et al. [20]. Measurements were made of porosity, osteon and haversian canal dimensions, and of interstitial and osteon mineral density across the cortical wall of the orthopedic calcar region. There were no differences between the fracture and nonfracture groups in the overall mean mineral density of the bone averaged over the microstructure, excluding pore space, or in the interstitial bone mineral density. The porosity in the fracture group was greater than in the autopsy group, especially in the periosteal region, where the porosity was 2.4 times greater and where there were also 27% fewer osteons per unit area than in the autopsy group (P < 0.05). Mean osteon mineral density was 2.5% higher in the fracture group (P < 0.05) compared with the autopsy group in the endosteal region, and 4% higher in the periosteal region. Osteon and haversian canal areas were also larger in the fracture group, especially in the middle region of the cortical wall (17% and 23%, respectively, P < 0.05).

Aged↗

Modified vein allograft for small arterial reconstruction in dogs.

The ideal graft for peripheral arterial reconstruction has yet to be developed. We evaluated on the effectiveness of porosity to intimization of the graft. Modified vein allografts newly constructed through digestion of vein allografts with elastase, glutaraldehyde tanning and lyophilization were implanted in thirty-nine canine femoral arteries. These grafts had a higher porosity than conventional vein allografts and the overall patency rate was 70 per cent at 6 months after implantation. Microscopic examination showed that graft interstitial healing and subsequent intimization were completed by ingrowth of connective tissue from outside through the graft wall at 3 weeks and later. Aneurysmal change of the modified vein allografts was never evident. These results indicated that porosity of the graft is indeed an important factor for intimization and durability of grafts, even in bioderivative substitutes.

Animals↗

Reduced bone formation and increased bone resorption: rational targets for the treatment of osteoporosis.

The net amount of bone lost during aging is determined by the difference between the amount of bone removed from the endocortical, trabecular and intracortical components of its endosteal (inner) envelope and formed beneath its periosteal (outer) envelope. Endosteal bone loss is determined by the remodeling rate (number of basic multicellular units, BMUs) and the negative balance (the difference between the volumes of bone resorbed and formed in each BMU). Bone loss already occurs in young adult women and men and is probably due to a decline in the volume of bone formed in each BMU. The rate of loss is slow because the remodeling rate is low in young adulthood. Bone loss accelerates in women at menopause because remodeling intensity increases and BMU balance becomes more negative as estrogen deficiency reduces osteoblast lifespan and increases osteoclast lifespan. The high remodeling rate also reduces the mineral content of bone tissue. The negative BMU balance results in trabecular thinning, disappearance and loss of connectivity, cortical thinning and increased intracortical porosity. These changes compromise the material and structural properties of bone while concurrent age-related subperiosteal bone formation increases the cross-sectional area (CSA) of bone partly offsetting endosteal bone loss and the loss of structural and material strength. Thus, treatments aimed at reducing the progression of bone fragility, and reversing it, should reduce activation frequency and so reduce the number of remodeling sites, reduce osteoclastic resorption in the BMU, and so reduce the volume of bone resorbed on each of the three components of the endosteal surface thereby reducing the progression of trabecular thinning, loss of connectivity, cortical thinning and porosity. If treatment also increases periosteal bone formation, the CSA of the whole bone and its cortical area will increase. If treatment also increases endosteal bone formation in the BMU, bone balance will be less negative, especially if resorption depth is reduced. This may produce thickening of trabeculae provided activation frequency is not too low. If treatment can increase de novo bone formation at quiescent endosteal surfaces, this will increase cortical and trabecular thickness, and reduce intracortical porosity. In this way, drugs directed at both the resorptive and formative aspects of remodeling, and bone modeling may (i) increase compressive and bending strength of cortical bone by increasing the diameter of the whole bone, its CSA and the distance the cortical mass is placed from the neutral long bone axis; (ii) maintain or increase peak compressive stress and peak strain in trabecular bone, preventing microcracks and buckling; and (iii) increase the material density of bone tissue, an effect that probably should not be permitted to reach a level which reduces resistance to microdamage accumulation and progression (toughness).

Aging↗

Magnetic resonance imaging measurements of bone density and cross-sectional geometry.

Magnetic resonance imaging (MRI) is commonly used in the assessment of the musculoskeletal system and associated pathology. The ability of MRI to measure the signals from water and lipid protons enables quantitative measurements of bone porosity. The goal of this investigation was to demonstrate that the density and cross-sectional geometry of whole bones can be noninvasively measured using MRI. Ten trabecular specimens cored from whale vertebrae were used to compare apparent bone density measured directly, and using a quantitative MRI algorithm. Bone density and several cross-sectional geometric properties were also measured using MRI in the distal tibia of 14 volunteers. The MRI measurements were compared with measurements made using quantitative-computed tomography (QCT). A proton density sequence was used for all MRI studies. A porosity phantom was included in the MRI examinations and used to convert the MRI signal intensity to bone volume fraction. Bone density and cross-sectional bone geometry were calculated from the bone volume fractions by assuming constant tissue properties. The apparent density of trabecular bone cores measured directly and using quantitative MRI were linearly related (r(2) = 0.959; P < 0. 01). A strong linear relation also existed between MRI and QCT measurements of ash density (r(2) = 0.923; P < 0.01) and cross-sectional geometric properties (r(2) = 0.976-0.992; P < 0.01). MRI data can be used to measure bone density and cross-sectional geometry of whole bones if a proton density sequence is used to homogenize differences in marrow composition and a porosity phantom is used for slice-specific volume fraction calibration.

Adult↗

Hydraulic strengthening affects the stiffness and strength of cortical bone.

A nonlinear, interstitial fluid flow constitutive model for cortical bone was developed to study the strain-rate dependency of cortical bone apparent modulus (Ea). Nine representative volume element (RVE) structural models of cortical bone spanning an effective pore volume fraction P range of 1-40% were examined. Dynamic loading conditions were used to study the fluid flow contribution or hydraulic strengthening (HS) effect on Ea for each RVE model. The model indicated that there is an upper and lower asymptotic bound of strain-rate (10(+/-3) sec(-1)) above or below which there are no further HS effects on Ea. At certain strain-rates (10(-1) to 10(0) sec(-1)) variations in cortical bone porosity had little or no influence on Ea. At lower and higher frequencies, the loss tangent, hence the magnitude of viscoelastic effects is greater. For strain-rates less than 10(-1) sec(-1), lower porosity RVE models were always stiffer than higher porosity RVE models. A generalized power law model is proposed to account for the fact that HS in cortical bone exhibits an upper and lower asymptotic bound and is bi-modal in terms of strain-rate.

Animals↗

Morphological evaluation of bioartificial hydrogels as potential tissue engineering scaffolds.

Poly(vinyl alcohol) hydrogels prepared by freeze-thawing procedure represent synthetic systems widely investigated as non-biodegradable scaffolds for tissue regeneration. In order to improve the biocompatibility properties of pure poly(vinyl alcohol) (PVA) hydrogels, blends of PVA with different biological macromolecules, such hyaluronic acid, dextran, and gelatin were prepared and used to produce "bioartificial hydrogels". The porosity characteristics of these hydrogels were investigated by scanning electron microscopy and mercury intrusion porosimetry. The morphology of bioartificial hydrogels was evaluated and compared with that of pure PVA hydrogels. In particular the effect exerted by each biological component on pore size and distribution was investigated. The obtained results indicate that when a natural macromolecule is added to PVA the internal structure of the material changes. A small amount of biopolymer induces the structural elements of PVA matrix to take on a well evident lamellar appearance and an apparent preferential orientation. Comparing the results of SEM and mercury intrusion porosimetry it was concluded that hydrogels containing 20% of biological component have the most regular structure and at the same time the lowest total porosity. On the contrary samples with the highest content of natural polymer (40%) show the less regular structure and the highest total porosity.

Biocompatible Materials↗

Fabrication of polymeric scaffolds with a controlled distribution of pores.

The design of tissue engineering scaffolds must take into account many factors including successful vascularisation and the growth of cells. Research has looked at refining scaffold architecture to promote more directed growth of tissues through well-defined anisotropy in the pore structure. In many cases it is also desirable to incorporate therapeutic ingredients, such as growth factors, into the scaffold so that their release occurs as the scaffold degrades. Therefore, scaffold fabrication techniques must be found to precisely control, not only the overall porosity of scaffolds, but also the pore size, shape and spatial distribution. This work describes the use of a regularly shaped porogen, sugar spheres, to manufacture polymeric scaffolds. Results show that pre-assembling the spheres created scaffolds with a constant porosity of 60%, but with varying pores sizes from 200-800 microm, leading to a variation in the surface area and likely degradation rate of the scaffolds. Employing different polymer impregnation techniques tailored the number of pores present with a diameter of less than 100 microm to suit different functions, and altering the packing structure of the sugar spheres created scaffolds with novel layered porosity. Replacing sugar spheres with sugar strands formed scaffolds with pores aligned in one direction.

Polymers↗

Porous Ti6Al4V scaffolds directly fabricated by 3D fibre deposition technique: effect of nozzle diameter.

3D porous Ti6Al4V scaffolds were successfully directly fabricated by a rapid prototyping technology: 3D fibre deposition. In this study, the rheological properties of Ti6Al4V slurry was studied and the flow rate was analyzed at various pressures and nozzle diameters. Scaffolds with different fibre diameter and porosity were fabricated. ESEM observation and mechanical tests were performed on the obtained porous Ti6Al4V scaffolds with regard to the porous structure and mechanical properties. The results show that these scaffolds have 3D interconnected porous structure and a compressive strength which depends on porosity at constant fibre diameters and on the fibre diameter at constant porosity. These Ti6Al4V scaffolds are expected to be constructs for biomedical applications.

Alloys↗

Mechanical cleansing of contaminated wounds with a surfactant.

Mechanical cleansing of a wound with a sponge soaked in a surfactant has prevented the development of experimental wound infection. The surfactant utilized for wound cleansing is Pluronic F-68, a member of a family of block copolymers called Pluronic polyols. Long-term toxicity studies and clinical trials suggest that this surfactant is safe for human use. Pluronic F-68 is a nonionic detergent that does not have any intrinsic antibacterial activity. Although mechanical cleansing with saline-soaked sponges effectively removes bacteria, it damages the wound and impairs its resistance to infection. The severity of the damage to the skin exerted by the sponge can be correlated with its porosity. Sponges with a low porosity are abrasive and exert more damage to skin than do sponges with a higher porosity. The addition of Pluronic F-68 to even the most abrasive sponges ensures that the bacterial removal efficiency of the sponge scrub is maintained, while tissue trauma is minimized. This dual effect of the surfactant results in a dramatic reduction in the infection rate of contaminated wounds. On the basis of these results, a clinical trial with surfactant-soaked sponges would appear to be indicated.

Animals↗