Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Polyethylene”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58Linked to original sources

Contamination of polyethylene cups with polymethyl methacrylate particles: an experimental study.

The articulating surfaces of 6 ultra-high molecular weight polyethylene cups were exposed to curing polymethyl methacrylate (PMMA) bone-cement and examined with scanning electron microscopy and laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS). Three of the cups were exposed to blood and bone-cement, and the rest were exposed to bone-cement only. After removal of the bone-cement bulk, PMMA particles were found and identified in all 6 cups. The particles were verified by identifying zirconium with energy-dispersive x-ray fluorescence spectroscopy in 5 cups and with LA-ICPMS in 1 cup. The degree of surface contamination was estimated with LA-ICPMS. The number of zirconium-containing particles detected was on average 10 to 20/mm2. PMMA bone-cement left in polyethylene cups during polymerization can contaminate the articulating surface with adherent PMMA particles.

Bone Cements↗

Study of retrieved acetabular sockets made from high-dose, cross-linked polyethylene.

Although ultra-high molecular weight polyethylene (UHMWPE) has stable chemical properties, chemical degradation, such as oxidation reaction, progresses with long-term clinical use. The purpose of this study was to investigate the change in properties of polyethylene (PE) in vivo by examining retrieved UHMWPE sockets and high-dose, cross-linked PE (100 Mrad PE) sockets. Twenty retrieved sockets (including 2 100 Mrad PE sockets), which were implanted from 1970 to 1996, were used for analysis. The oxidation index of 100 Mrad PE sockets was approximately the same as that of the normal UHMWPE sockets in worn areas. These long-term clinical results indicate that 100 Mrad PE is sufficiently stable for clinical use and that free radicals would not affect progression of oxidation significantly.

Acetabulum↗

Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene: a new concept.

The design of femoral and acetabular components of metal-on-polyethylene total hip arthroplasty implants has been dominated by the limitations of the wear properties of ultra-high molecular weight polyethylene (UHMWPE). As a result, the commonest femoral head diameters used range from 22 to 32 mm, the latter producing maximal volumetric wear. Cross-linking has been shown to improve significantly the wear resistance of acetabular components when tested in vitro against conventional femoral head sizes (22-32 mm). We expanded the study of the wear behavior of 1 type of electron-beam cross-linked UHMWPE with femoral head diameters ranging from 22 to 46 mm. The simulated gait studies showed that wear was independent of head size for the range of femoral head sizes studied. Even for the 46-mm femoral head, wear was reduced significantly using criteria of gravimetric and geometric measurements and morphologic appearance of the machining marks out to 11 million cycles of simulated gait.

Acetabulum↗

Press-fit versus cemented all-polyethylene patellar component: midterm results.

This study compared the midterm results between press-fit and cemented implantation of a highly congruent, all-polyethylene patellar component. We followed prospectively 172 implants (cemented, n = 133; press-fit, n = 39). Average follow up was 6 years (range, 5-8 years). Patellofemoral complications occurred in 4 cemented patellae (2.3%). Two of these patellae required revision. Cemented implants had a significantly higher incidence of patellar maltracking (30% vs 8%; P= .005). No significant differences in the overall Knee Society scores (mean, 165; SD, 27) or any of its components relevant to patellofemoral function were detected between fixation methods. A retrieved specimen showed an intervening fibrous membrane at the implant-bone interface. The potential for macrophage-mediated osteolysis at this site is unknown. No other adverse outcome was associated with press-fit implantation. These results suggest that at midterm follow-up, press-fit implantation of this all-polyethylene patellar component may improve tracking and represents a viable alternative to cement fixation.

Aged↗

Accurate in vivo measurement of polyethylene wear in total knee arthroplasty.

This study describes a new technique to evaluate accurate linear polyethylene wear and reports the in vivo annual linear wear rate in total knee arthroplasty. Patients (n = 69) were assessed using a single standing anteroposterior radiograph with 8 reference markers around the knee, where 3-dimensional (3D) locations of markers and 3D geometry of the implant were known. By matching the 3D locations of the markers and their projected points on the radiograph, 3D/2D transformation parameters were estimated. Using these parameters, the 3D coordinates of the implant were estimated from the projected x-ray silhouette. After calculating the femorotibial shortest distance, wear and creep deformity of the polyethylene was defined with an accuracy of 0.1 mm or better. Measured linear wear in the 69 knees varied from 0 mm (1 month postoperatively) to 2.71 mm (7 years postoperatively). The correlation of linear wear (Y) and year (X) was Y = 0.23 X -0.11 (P<.001). This study revealed that annual wear rate was 0.23 mm and 2 times greater than the average annual wear rate in total hip arthroplasties.

Aged↗

Polyethylene liner cementation into fixed acetabular shells.

A patient presenting with a secure cementless acetabular component and with femoral head penetration through the polyethylene liner is a common clinical problem. Cementing a new liner into the fixed shell is one option. We evaluated this option in a clinical series of 17 cases and with a preliminary mechanical study. In the 1 clinical failure (5.9%), the failure occurred at the cement-liner interface. The most important variable in optimizing the mechanical strength of the cemented liner construct was adequate preparation of the cement-liner interface. This approach to treating the patient with a fixed cementless shell and a worn polyethylene liner can provide a durable construct with minimal morbidity.

Aged↗

Polyethylene liner exchange for excessive wear and osteolysis.

To determine if polyethylene liner exchange of a total hip arthroplasty decreased wear and slowed the progression of osteolysis, we evaluated 10 hips at a mean 6.2 years after component exchange. Head penetration and lesion size were quantified on serial radiographs using computer-assisted techniques. A mean 7.9 years before component exchange, true polyethylene wear rates averaged 0.36 +/- 0.19 mm/y. A mean 6.2 years after component exchange, average wear rates decreased to 0.17 +/- 0.11 mm/y. Similarly, mean acetabular and mean femoral lesion growth rates decreased. At last follow-up, all components remained radiographically stable. Complications included dislocation (1 patient) and increased wear (2 patients). Modular component exchange with removal of granulomatous tissue has the potential to decrease wear and slow the progression of osteolysis without subsequent component loosening.

Adult↗

Prediction of total knee arthroplasty polyethylene wear using the wear index.

The predictive value of the wear index for total knee arthroplasty polyethylene wear was determined using a numeric and in vitro model. The wear index was defined as the deformation x the sliding velocity. Four commercially available total knee prostheses were modeled for this study. Deformation and sliding velocity were calculated from the 3-dimensional geometry of the components and the gait kinematic inputs using Hertz's formula. A knee simulation test was performed under the same conditions, and the surface of the inserts was compared with the wear index. This study showed good agreement between the numeric model and the simulation test, suggesting that the wear index is a reliable predictor of total knee arthroplasty polyethylene wear through its incorporation of contact stress and kinematics.

Arthroplasty, Replacement, Hip↗

Polyethylene-induced pes anserinus bursitis mimicking an infected total knee arthroplasty: a case report and review of the literature.

Polyethylene-induced pes anserinus bursitis after total knee arthroplasty (TKA) with the clinical manifestations mimicking an infected TKA is a very rare occurrence. We report such a case in a 74-year-old woman. She developed recurrent draining papules on the anterolateral aspect of the knee because of polyethylene-induced chronic pes anserinus bursitis 8 years after TKA. The diagnosis was established with a sinography study and confirmed by histopathologic examination of the surgical specimen. The symptoms were resolved after surgical excision of the lesion. Pes anserinus bursitis should be included in the differential diagnosis in knees with a draining sinus after TKA, and sinogram is considered the best method to establish the diagnosis.

Aged↗

Exposure of high-density porous polyethylene (Medpor) used for contour restoration and treatment.

Porous high-density polyethylene (Medpor) is a biocompatible large-pore, high-density polyethylene implant. It is well tolerated by surrounding tissue, and its porous structure is rapidly infiltrated by host tissue. It is a highly stable and somewhat flexible porous alloplast that has rapid tissue ingrowth into its pores. However, when the implant is placed under a thin cover of skin, there is a risk of exposure. A total of 52 Medpor implants were placed in 31 patients over a four-year period. The implants were used for the chin, malar area, nasal reconstruction, ear reconstruction, orbital reconstruction, and the correction of mandibular contour deformities. Many of these implants were placed in areas considered problematic, such as those with thin or atrophic soft-tissue coverage and extensive scarring. There were nine complications, including three patients in whom the implant was exposed; these are presented here.

Adult↗

Improvement of the bioavailability of colchicine in rats by co-administration of D-alpha-tocopherol polyethylene glycol 1000 succinate and a polyethoxylated derivative of 12-hydroxy-stearic acid.

Two surface-active formulation ingredients, a water-soluble derivative of vitamin E (D-alpha-tocopherol polyethylene glycol 1000 succinate, vitamin E-TPGS) as well as a polyethoxylated derivative of 12-hydroxy-stearic acid (Solutol HS 15) were investigated in rats for their potential to increase the oral bioavailability of the p-glycoprotein (p-gp) and cytochrome P450 substrate colchicine. D-alpha-Tocopherol polyethylene glycol 1000 succinate and the polyethoxylated derivative of 12-hydroxy-stearic acid will be referred to as "surfactant 1" and "surfactant 2" in the following. Colchicine was administered to the animals at a dose level of 5 mg/kg in each 10% surfactant containing formulation. A solution of colchicine in isotonic saline was selected as a reference formulation. It was found that the administration of colchicine in the surfactant containing formulations resulted in significantly higher systemic exposures as compared to the aqueous reference vehicle (2-fold increase in AUC in the presence of surfactant 1 and 4-fold increase in AUC in the presence of surfactant 2). The aqueous solubility of colchicine was about 16.7 mg/ml, and the increase in solubility in the presence of 1% surfactant 1 or surfactant 2 to about 20.5 and 18.5 mg/ml was not considered to significantly affect the oral bioavailability. In summary, it was demonstrated that both surfactants are suitable formulation ingredients to improve the systemic exposure of colchicine in the rat. Due to the high aqueous solubility of colchicine the most likely reasons for these findings are inhibition of p-gp and/or metabolism as well as permeability enhancement by interactions of the surfactants with the intestinal membrane.

ATP Binding Cassette Transporter, Subfamily B, Mem↗

Microtia reconstruction using a porous polyethylene framework.

We describe our method for reconstructing microtic auricles using a porous polyethylene framework in two stages. The first stage of the procedure involves rotating a superficial temporoparietal fascial (TPF) flap over the framework. The inferior two-thirds of this framework is next inset into a local temporal skin pocket, while the superior one-third is covered with a full thickness skin graft from the contralateral postauricular sulcus. Lobular transposition is commenced in a second stage procedure at the three-month postoperative period. Hearing restoration surgery is encouraged at a later date in selected patients with unilateral microtia. Use of the porous polyethylene framework permits a more expedient, less invasive, and more reliable method for auricular reconstruction than does the traditional method that employs costal cartilage.

Child↗

A prospective randomized study of hydrophilic polymer-coated polyurethane versus polyethylene stents in distal malignant biliary obstruction.

BACKGROUND AND STUDY AIMS: Hydrophilic polymer-coated polyurethane (HPCP) stents have a low friction coefficient and a hydrophilic layer, which may reduce biofilm formation and increase the period of stent patency. We compared the patency rates with this new stent with the standard Amsterdam-type polyethylene (PE) stent in a prospective randomized trial. PATIENTS AND METHODS: One hundred patients with an unresectable distal malignant bile duct stricture without a previous drainage procedure were randomly assigned to receive either a HPCP stent or a PE stent. The diameter (10 Fr), length (9 cm) and stent design (Amsterdam type) were similar in both stents. Nine patients were excluded. Forty-four patients received an HPCP stent and 47 patients a PE stent. The diagnoses included carcinoma of the pancreas (n = 78), papilla (n = 1), bile duct (n = 10), and metastases (n = 2). RESULTS: Stent insertion was successful in all patients. Stent dysfunction occurred in 27 of the HPCP stents and 20 of the PE stents, with median stent patency periods of 77 days (95 % CI, 53-101 days) for HPCP stents and 105 days (95 % CI, 42-168 days) for PE stents. The patency period was significantly longer for the PE stent (P = 0.04). Early complications occurred in four patients (4%), one in the HPCP group and three in the PE group. CONCLUSION: Hydrophilic polymer-coated polyurethane stents do not prolong the patency period of biliary stents. In fact, the current standard treatment using polyethylene stents in patients with distal malignant biliary obstruction showed a significantly longer patency period.

Aged↗

[Results of experimental testing of a screw-in in polyethylene acetabulum in sheep].

In 12 sheep 21 total hip endoprosthesis were implanted, using a polyethylene acetabulum, which was provided with a continuous conique thread for implantation without cement. Out of 14 non luxated hips only 2 acetabula were loosened. After an implantation between 1 week and 18 months the remaining 12 sockets were macroscopically stable and were examined radiologically and histologically. After 3 months of increased osteogenesis a layer of collagenous tissue developed between implant and bone. In the loadbearing area this layer is from 50-80 microns thick and often the ridges of the thread are stabilised by a thin layer of fiber-cartilage, expanding around the implant with longer implantation. Bore-holes in the thread are filled with partially lamellous bone after 6 months. Though sometimes a considerable amount of polyethylene wear particles caused by the disadvantageous and small shape of the sheeparthroplasty was observed, none of the examined acetabula showed any signs of loosening.

Acetabulum↗

[Wear of the polyethylene components of endoprostheses following clinical application].

13 various hip joint and knee joint polyethylene components, previously removed from patients after an implantation period of 1.5 to 4 years, were tested and showed an obvious damage of the sliding surface. Macroscopic and microscopic investigations performed by light and scanning electron microscopy revealed an extreme wear of the polyethylene surface respectively an unregular wear at the component's border up to the mm-range. Additional specific X-ray and infrared spectrometric analyses proved in the clear majority of all cases the contribution of bone cement to increased abrasion and its influence upon the intensity of wear. Surplus bone cement which had not been completely removed from the prosthesis component or loosening of prosthesis components are considered as reason for inclusion of bone cement particles between the sliding surfaces.

Bone Cements↗

Simulation of the effects of chain architecture on the sorption of ethylene in polyethylene.

An osmotic ensemble hyperparallel tempering technique has been developed to study the solubility of ethylene in amorphous linear low-density polyethylene of different chain architectures. The NERD united-atom force field (Nath, Escobedo, and de Pablo revised united-atom force field) is used in all simulations. We have investigated the effect of polyethylene chain length and branching on ethylene solubility. In this study, we have considered short-chain branching of amorphous linear low-density ethylene-1-hexene copolymers under typical polymerization reactor conditions. It is observed that, in the polymer, ethylene prefers to reside in the vicinity of polymer chain ends. This clustering causes a decrease in ethylene solubility with polymer chain length. When short-chain branches are introduced to a linear polymer chain, however, the chain-end clustering effect is counteracted by a higher density, thereby leading to an ethylene solubility almost identical to that in the linear polymer.

Adsorption↗

Leukocyte activation and leukocyte procoagulant activities after blood contact with polystyrene and polyethylene glycol-immobilized polystyrene beads.

Beads (45 microm) of polystyrene (PS) and polyethylene glycol modified PS (TentaGel) with an amino or hydroxyl terminal group were incubated with blood to assess the effect of surface area and material chemistry on leukocyte activation. After a 2-hour incubation, blood contact with beads activated leukocytes in the bulk (tissue factor expression, CD11b up-regulation, and association with platelets) independently of material surface chemistry. On the other hand, activation of adherent leukocytes was material dependent. After blood contact with PS, polyethylene glycol-immobilized PS (PS-PEG) and PS-PEG-NH2 beads, CD11b up-regulation in the bulk, platelet-leukocyte aggregates, and leukocyte adhesion were all dependent on surface area, whereas tissue factor (TF) expression was not. Material-induced leukocyte activation in the bulk was also independent of the beads' capacity to activate platelets. However, monocyte adhesion and TF expression on beads appeared to be related to the presence of platelets on the surface. Material-induced TF expression was able to initiate the extrinsic pathway of coagulation, resulting in significant fibrin formation. Although not all of our markers of leukocyte activation varied with material area or chemistry, it was clear that these materials activated leukocytes in a way that resulted in increased procoagulant activity. During blood-material interactions, material-induced leukocyte activation may then contribute to thrombogenesis.

Blood Coagulation↗

Site-specific chemical modification with polyethylene glycol of recombinant immunotoxin anti-Tac(Fv)-PE38 (LMB-2) improves antitumor activity and reduces animal toxicity and immunogenicity.

Chemical modification of proteins with polyethylene glycol (PEGylation) can increase plasma half-lives, stability, and therapeutic potency. To make a PEGylated recombinant immunotoxin with improved therapeutic properties, we prepared a mutant of anti-Tac(Fv)-PE38 (LMB-2), a recombinant immunotoxin composed of a single-chain Fv fragment of the anti-human Tac monoclonal antibody to the IL-2 receptor alpha subunit fused to a 38-kDa fragment of Pseudomonas exotoxin. For site-specific PEGylation of LMB-2, one cysteine residue was introduced into the peptide connector (ASGCGPE) between the Fv and the toxin. This mutant LMB-2 (cys1-LMB-2), which retained full cytotoxic activity, was then site-specifically conjugated with 5 or 20 kDa of polyethylene glycol-maleimide. When compared with unmodified LMB-2, both PEGylated immunotoxins showed similar cytotoxic activities in vitro but superior stability at 37 degrees C in mouse serum, a 5- to 8-fold increase in plasma half-lives in mice, and a 3- to 4-fold increase in antitumor activity. This was accompanied by a substantial decrease in animal toxicity and immunogenicity. Site-specific PEGylation of recombinant immunotoxins may increase their therapeutic potency in humans.

Animals↗