Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Pitch Perception”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58Linked to original sources

High frequency audiometry.

After a brief discussion of the past use of and clinical need for high frequency hearing tests, a new technique is described that uses a special electric transduction mode: a 60-kHz carrier frequency is modulated by the desired audiofrequency. The combined signal is applied to the skin over the mastoids by Mylar-covered electrodes. On perception, the audiofrequency part of the input shows all the properties of a bone-conduction signal. The carrier frequency is dispersed in the tissues. Production and calibration of electrical high frequency signals, up to 20 kHz, is straightforward and easier than that of conventional air-conduction and (vibromechanical) bone-conduction signals. The efficacy of the method is illustrated by means of preliminary hearing tests conducted on several subjects.

Animals↗

Linguistic perception: neural processing of a whistled language.

Silbo Gomero is a whistled language that is a rare and endangered surrogate of Spanish, used by shepherds on the island of La Gomera in the Canary Islands for communication over long distances on difficult terrain. Here we show that areas of the brain normally associated with spoken-language function are also activated in proficient whistlers, but not in controls, when they are listening to Silbo Gomero. Our findings demonstrate that the language-processing regions of the human brain can adapt to a surprisingly wide range of signalling forms.

Acoustic Stimulation↗

Temporal and spatio-temporal vibrotactile displays for voice fundamental frequency: an initial evaluation of a new vibrotactile speech perception aid with normal-hearing and hearing-impaired individuals.

Four experiments were performed to evaluate a new wearable vibrotactile speech perception aid that extracts fundamental frequency (F0) and displays the extracted F0 as a single-channel temporal or an eight-channel spatio-temporal stimulus. Specifically, we investigated the perception of intonation (i.e., question versus statement) and emphatic stress (i.e., stress on the first, second, or third word) under Visual-Alone (VA), Visual-Tactile (VT), and Tactile-Alone (TA) conditions and compared performance using the temporal and spatio-temporal vibrotactile display. Subjects were adults with normal hearing in experiments I-III and adults with severe to profound hearing impairments in experiment IV. Both versions of the vibrotactile speech perception aid successfully conveyed intonation. Vibrotactile stress information was successfully conveyed, but vibrotactile stress information did not enhance performance in VT conditions beyond performance in VA conditions. In experiment III, which involved only intonation identification, a reliable advantage for the spatio-temporal display was obtained. Differences between subject groups were obtained for intonation identification, with more accurate VT performance by those with normal hearing. Possible effects of long-term hearing status are discussed.

Adult↗

Cues to the perception of Taiwanese tones.

A labeling test with synthetic speech stimuli was carried out to determine to what extent the two dimensions of fundamental frequency (F0), height and movement, and syllable duration provide cues to tonal distinctions in Taiwanese. The data show that the high level vs. mid level tones and the high falling vs. mid falling tones can be reliably distinguished by F0 height alone, whereas the distinction between tones with dissimilar contours, such as the high falling and low rising tones, is predominantly cued by F0 movement. However, the other dimension of F0 may collaborate with the dominant one in cueing a tonal contrast, depending on the extent to which the two tones differ along that dimension. Syllable duration has a small additional effect on the perception of the distinction between falling and nonfalling tones. These results are consistent with previous findings in tone languages other than Taiwanese in that they suggest that tones are mainly cued by F0. While the primacy of F0 dimensions as cues to tonal contrasts depends on the contrast to be distinguished, the present findings show that tones which nominally differ only in register (e.g., high falling vs. mid falling) may exhibit perceptually relevant contour differences, and vice versa.

Communication Devices for People with Disabilities↗

Pedagogical efficiency of melodic contour mapping technology as it relates to vocal timbre in singers of classical music repertoire.

The purpose of this investigation was to ascertain the pedagogical viability of computer-generated melodic contour mapping systems in the classical singing studio, as perceived by their resulting effect (if any) on vocal timbre when a singer's head and neck remained in a normal singing posture. The evaluation of data gathered during the course of the study indicates that the development of consistent vocal timbre produced by the classical singing student may be enhanced through visual/kinesthetic response to melodic contour inversion mapping, as it balances the singer's perception of melodic intervals in standard musical notation. Unexpectedly, it was discovered that the system, in its natural melodic contour mode, may also be useful for teaching a student to sing a consistent legato line. The results of the study also suggest that the continued development of this new technology for the general teaching studio, designed to address standard musical notation and a singer's visual/kinesthetic response to it, may indeed be useful.

Adolescent↗

Cortical sound processing in children with autism disorder: an MEG investigation.

Previous work investigating frequency encoding mechanisms in human auditory cortex has provided evidence that latency of the auditory evoked M100 is strongly proportional to frequency, with low frequency (100-200 Hz) tones associated with approximately 30 ms longer latencies than mid-range frequency (1-2 kHz) tones. Motivated by pervasive speech and auditory perception deficits observed in autism spectrum disorder, we evaluated M100 frequency dependence in children with autism disorder and typically developing controls. Results indicate that for control children, the dynamic range of frequency modulation was similar to previous reports for healthy adults. Children with autism had a much reduced range of modulation in right hemisphere sites. Findings indicate that frequency encoding mechanisms may follow a differential maturational path in autism spectrum disorder.

Acoustic Stimulation↗

[Clinics and psychopathology of tinnitus: a psychiatric view (author's transl)].

Unstructured and structured, elementary tinnitus or achoasms are regarded as symptoms of various origins and individual processing of experience even in psychiatric diseases. In the context of a multidimensional causal structure for disturbances of acoustic perception, the lesion and compensatory capacity of the sensory system, primary personality structure, strategy for psychodynamic conflict resolution and above all the constitutionally determined or acquired biological structure of the central nervous system decide on what becomes subjective experience from the objective reduction of auditory function and what is observed as clinically as tinnitus. Besides psychopathological and neuropsychological aspects, the clinics of tinnitus is touched on an acoustic hallucinosis of the hard of hearing is illustrated by reference to a case history and its pathogenesis is discussed.

Auditory Pathways↗

Evaluation of simple models of auditory profile analysis using random reference spectra.

This article describes further study of the finding reported by Green et al. [J. Acoust. Soc. Am. 73, 639-643 (1983)] and others that, in certain conditions, the threshold of detectability for an intensity increment to the center tone of a multitone reference spectrum decreased as the number of nonsignal tones increased. That result was considered remarkable since critical-band theory would predict that these nonsignal tones, spaced outside the "critical band" containing the signal, would have no effect on or, at most, slightly decrease within-band detectability--and certainly could not account for the result of improved detectability found in the study cited above. Recently, Henn and Turner [J. Acoust. Soc. Am. 88, 126-131 (1990)] were unable to replicate the result described above, concluding that the phenomenon exists only in "limited conditions" and that is "highly individual" in nature. Further, they speculated that the most likely reason for the discrepancy between their study and previous studies was the selection and/or training of the observers. The present study addressed the effects of the amount of subject training on the finding of Green et al. while controlling the potential effects of stimulus order. Specifically, for a group of three "naive" listeners, thresholds were measured for 3-, 7-, and 21-tone inharmonic complexes as a function of the amount of practice in a mixed-block design. In all cases the group mean thresholds decreased as the number of nonsignal tones increased both initially and after extensive practice for both fixed- and roving-level conditions. Thus the effect does not appear to be an artifact of the amount or order of training subjects receive. The possible role of subject sample size and the magnitude of individual differences in obtaining the effect remains an open question. Two hypotheses suggested to account for the improvement in threshold with increasing number of nonsignal tones were evaluated. The hypotheses were represented by simple mathematical models, referred to as the "multiple-comparison" and "pitch-cue" models. The predictions of both models were compared with the results of a series of detection experiments in which the independent variables were the number of nonsignal tones and amount of random, within-trial "amplitude perturbation" [cf. Kidd et al., J. Acoust. Soc. Am. 79, 1045-1053 (1986)] of the nonsignal tones. Neither model, as applied, provided a satisfactory account of the effects of the main variables of number of tones and amount of perturbation.(ABSTRACT TRUNCATED AT 400 WORDS)

Adult↗

The perception of 'forward' and 'backward placement' of the singing voice.

Singing teachers sometimes characterize voice quality in terms of 'forward' and 'backward placement'. In view of traditional knowledge about voice production, it is hard to explain any possible acoustic or articulatory differences between the voices so 'placed'. We have synthesized a number of three-tone melodic excerpts performed by the singing voice. Formant frequencies, and the level and frequency of the singer's formant were varied across the stimuli. Results of a listening test show that the stimuli which were perceived as 'placed forward', correlated not only with higher frequencies of the first and second formants, but also with the higher frequency and level of the singer's formant.

Female↗

Perception of the simple difference tone (f2-f1).

The present study examined the dependence of difference tone level [L(f2-f1)] on the following parameters of the two-tone input: f1, f2/f1 (f2 greater than f1), L1, L2, and L1 = L2. Difference tone levels were estimated in four normal hearers using a 2AFC adaptive temporal gap-masking paradigm. The key finding in this study is the apparent interaction of each factor with the other. For example, primary level (L1 = L2) was found to affect the dependence of L(f2-f1) on f1 and on f2/f1. In addition, the frequency separation of the primaries (f2/f1) was also seen to exert an influence on the dependence of difference tone level on L1, L2, and L1 = L2.

Acoustic Stimulation↗

Attentional processes in time perception: effects of mental workload and event structure.

The role of attention in timing was evaluated in 2 experiments. In Experiment 1, participants reproduced the durations of melodies with either a coherent or an incoherent structure. Participants were tested under control (timing only) and detection (timing plus target detection) workload conditions. Reproductions were shorter and more inaccurate under detection conditions, and incoherent event structure extended the effect to a wider range of durations. In Experiment 2, participants reproduced the durations of auditory prose passages that represented 3 levels of mental workload and 3 levels of event structure. Both increases in workload and the degradation of structure led to inaccurate reproductions. The results point to the central role of attention in temporal experience.

Adult↗

Auditory implants and tactile aids for the profoundly deaf.

This paper reviews data on speech perception via implanted electrodes and via tactile aids. The two approaches are compared in terms of amount and types of aid provided to communication. Related issues discussed are the performance levels with multi-versus single-channel implants, promontory electrical stimulators versus implants, use of minimal residual hearing, implants for children, and the possible design of complementary systems combining auditory implant and tactile information. The diversity of the test methods and subjects used in implant versus tactile research precludes definitive comparisons of speech perception performance. However, it appears from the available data that, at present and for the foreseeable future, neither approach can provide more than a modest aid to lipreading. Speech reception test results from multichannel-implanted subjects are better, on the average, than for single-channel subjects. However, the best single-channel results are comparable to the best multichannel in tests using simple sentences. There is great variation among subjects with the same implant. Tactile aid performance by highly practiced subjects seems comparable to that of the better implant subjects.

Adolescent↗

A multiple electrode cochlear implant.

The University of Melbourne Departments of Otolaryngology and Electrical Engineering (UMDOLEE) receiving and stimulating component of a multiple-electrode cochlear implant hearing prosthesis produces constant stimulation. It has a stimulating pulse shape that minimizes the production of toxic substances and loss of metal from the electrodes, and this is achieved with a biphasic rectangular waveform where the first phase is negative with respect to ground. The duration of each stimulus phase in 180 msec, which is long enough to allow low levels of current stimulation, and short enough to permit rates of 1000 pulses/second to be achieved. In order to be consistent with our present understanding of the perception of pitch, the device permits the independent stimulation of a number of electrodes. Furthermore, to electrically isolate the stimulus to small areas, there is the capacity to vary the current and set the threshold independently at individual electrodes. The phase and amplitude of the pulses to neighbouring electrodes with also be varied to assist in localizing the current flow. The pattern to stimulation to individual or groups of electrodes can also be altered to enable studies to be carried out to determine ways of conveying frequency and intensity information over a more normal dynamic range.

Animals↗

Infants' perception of rhythm: categorization of auditory sequences by temporal structure.

We presented 7- to 9-month-old infants with repetitions of three- or four-tone sequences characterized by a particular rhythmic structure. We then evaluated their detection of changes in rhythmic structure in the context of randomly presented variations in tempo (rate) and frequency. Infants successfully differentiated between three-tones sequences with 1, 2 (X XX) and 2, 1 (XX X) structure as well as four-tone sequences with 2, 2 (XX XX) and 3, 1 (XXX X) structure. In other tasks, they indicated their ability to discriminate between contrasting tempos in the context of frequency variations. We conclude, then, that infants can categorize auditory sequences on the basis of rhythm and also on the basis of tempo.

Arousal↗

Infants' perception of melodies: the role of melodic contour.

Infants 8-11 months of age were exposed to repetitions of a 6-tone sequence or melody, then tested for their discrimination of transpositions of that sequence as well as other melodic transformations previously used by Massaro, Kallman, and Kelly with adults. In experiment 1, infants showed evidence of discriminating all transformations from the original melody. In Experiment 2, the task was made more difficult, and infants failed to discriminate transpositions of the original melody as well as transformations that preserved the melodic contour and approximate frequency range of the original melody. By contrast, infants showed evidence of discriminating transformations that violated the contour of the original melody or that included changes in the octaves from which component tones were drawn. This global processing strategy parallels that used by adults with atonal or unfamiliar tonal melodies.

Attention↗

Evidence for a central representation of instrument timbre.

An information processing account of perception seeks to delineate the stages of processing through which a stimulus passes and determine the properties of the representation at each stage. Research in phonetic perception has identified two stages, the second of which is thought to encode abstract acoustic attributes of sounds. The present study provided a further test of this proposal by assessing whether nonphonetic stimuli could yield results similar to those obtained with phonetic stimuli. Five selective adaptation experiments were carried out with a trumpet-piano timbre continuum. Two manipulations were used to measure abstract encoding: cross-ear presentation of adaptor and test series, and the use of adaptors that were acoustically different from the continuum end-points. The results provide evidence for an abstract representation of timbre. The similarity of the findings to those in the phonetic adaptation literature is discussed.

Adult↗

Auditory evoked potentials in females with high and low acceptance of background noise when listening to speech.

Acceptable noise level (ANL) is a measure of a listener's acceptance of background noise when listening to speech. A consistent finding in research on ANL is large intersubject variability in the acceptance of background noise. This variability is not related to age, gender, hearing sensitivity, type of background noise, speech perception in noise performance, cochlear responses, or efferent activity of the medial olivocochlear pathway. In the present study, auditory evoked potentials were examined in 21 young females with normal hearing with low and high acceptance of background noise to determine whether differences in judgments of background noise are related to differences measured in aggregate physiological responses from the auditory nervous system. Group differences in the auditory brainstem response, auditory middle latency response, and cortical, auditory late latency response indicate that differences in more central regions of the nervous system account for, at least in part, the variability in listeners' willingness to accept background noise when listening to speech.

Adult↗

[The acoustics of the open mastoid cavity (so-called "radical cavity") and its modification by surgical measures. II. Clinical studies].

The acoustic resonance of a severely altered outer ear channel (radical mastoid cavity) is investigated in a series of 18 patients who underwent revision surgery by means of in-situ measurements of the sound-pressure-level near the tympanic membrane. While the average volume of the open cavity differs from the normal ear channel for the factor 2.5, the size of the external meatus is--in average--only 20% larger. This leads to an average frequency in patients with open cavity of 1939 Hz, more than 1000 Hz less than in a series (n = 20) of normal ears (average resonance frequency: 2942 Hz). The altered acoustic behaviour of the open cavity leads to partial extensive discrepancies of the resonance-caused sound-pressure augmentation in the frequencies of 3 and 4 kHz, which are important for speech perception. The average difference is more than 10 dB (SPL). Proved surgical techniques of cavity obliteration and meatoplasty can lead to a nearly normalized acoustic behaviour of the outer ear in a statistic significant way. Due to these surgical procedures, an average postoperative resonance frequency of 2421 Hz could be reached in our patients. Especially, the resonance-caused sound-pressure augmentation in 3-4 kHz could nearly be equalized to such of a normal outer ear. Differences in the acoustic behaviour of the outer ear as can be found between patients with an open mastoid cavity and normal ears can almost be eliminated surgically.(ABSTRACT TRUNCATED AT 250 WORDS)

Acoustics↗