Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Monitoring”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58Linked to original sources

A multicenter description of intermediate-care patients: comparison with ICU low-risk monitor patients.

STUDY OBJECTIVES: To describe the characteristics and outcomes of patients admitted to intermediate-care areas (ICAs) and to compare them with those of ICU patients who receive monitoring only on day 1 and are at a low risk (i.e., < 10%) for receiving subsequent active life-supporting therapy (i.e., low-risk monitor patients). DESIGN: Nonrandomized, retrospective, cohort study. SETTING: Thirteen US teaching hospitals and 19 nonteaching hospitals. PATIENTS: A consecutive sample of 8,971 patients at 37 ICAs and 5,116 low-risk (i.e., < 10%) monitor patients at 59 ICUs in 32 US hospitals. INTERVENTIONS: None. MEASUREMENTS AND RESULTS: We recorded demographic and clinical characteristics, resource use, and outcomes for the ICA and ICU low-risk monitor patients. Patient data and outcomes for this study were collected concurrently or retrospectively. ICA and ICU low-risk monitor patients were similar in regard to gender, race, and frequency of comorbitities, but ICA patients were significantly (p < 0.001) older, had fewer physiologic abnormalities (mean acute physiology score, 16.7 vs 19.8, respectively), and were more frequently admitted due to nonoperative diagnoses. The mean length of stay for ICA patients was significantly longer (3.9 days) than for ICU low-risk monitor patients (2.6 days; p < 0.001). The hospital mortality rate was significantly higher for ICA patients (3.1%) compared to ICU low-risk monitor patients (2.3%; p = 0.002). CONCLUSIONS: The clinical features of ICA patients are similar, but not identical to, those of less severely ill ICU monitor patients. Comparisons of hospital death rates and lengths of stay for these patients should be adjusted for characteristics that previously have been shown to influence these outcomes.

APACHE↗

A prospective randomized comparison of train-of-four monitoring and clinical assessment during continuous ICU cisatracurium paralysis.

STUDY PURPOSE: Train-of-four (TOF) monitoring is often recommended during the continuous use of neuromuscular blockade (NMB) [paralysis] in the ICU. Prior study results are conflicting regarding the benefits of TOF monitoring. DESIGN: Thirty patients in the medical ICU were randomized to TOF monitoring (n = 16) or to clinical assessment (n = 14) during continuous cisatracurium infusion. TOF monitoring was done at least every 4 h, with the goal being maintenance of one to two twitches. Statistical analysis was performed by two-tailed, unpaired t test (with Bonferroni correction for multiple comparisons), chi(2), and Fisher exact test, with p < 0.05 considered significant. Given a power of 80%, and the variance seen in the two groups, we estimate that the sample size used is sufficient to detect a change of > or = 60 min between groups for recovery time. RESULTS: The mean recovery time after cessation of paralytics was no different between TOF and clinical assessment (45 +/- 7 min vs 38 +/- 10 min, respectively [mean +/- SEM]). No differences were noted for mean APACHE (acute physiology and chronic health evaluation) II entry scores, glomerular filtration rates, or use of corticosteroids. No significant differences were noted between TOF monitoring and clinical assessment in mean total paralysis time (4,118 +/- 1,012 min vs 3,188 +/- 705 min, respectively), mean total cisatracurium dose (920 +/- 325 mg vs 715 +/- 167 mg), or dosage (2.3 +/- 0.2 microg/kg/min vs 2.9 +/- 0.2 microg/kg/min). CONCLUSIONS: TOF monitoring does not lead to improved recovery time or lower cisatracurium dosing compared with monitoring by clinical assessment. We conclude that TOF monitoring is unnecessary, and careful titration of the neuromuscular blocking agent by clinical assessment alone is sufficient in patients undergoing continuous cisatracurium NMB.

Atracurium↗

Automated 24-hour ambulatory blood pressure monitoring in preeclampsia.

A prospective controlled study was designed to compare automated 24-hour ambulatory blood pressure monitoring with intermittent blood pressure recordings obtained using a sphymomanometer. Blood pressure was measured in 20 hospitalized preeclamptic women in the third trimester. Data obtained using the Spacelabs automated blood pressure monitor was recorded over a period of 24 hours, and thereafter stored and processed in a computer. During the same 24 hour period, blood pressure and heart rate were measured by experienced staff at 07.00, 10.00, 13.00, 15.00, 18.00 and 21.00 hours, with the patient in a semi-recumbent position using a conventional mercury sphygmomanometer with a cuff of appropriate size. Korotkoff phase 5 was used as the indicator of diastolic blood pressure in all recordings by the staff. The main outcome measures were systolic and diastolic blood pressure, mean arterial blood pressure and maternal heart rate. Automated ambulatory monitoring was well tolerated and gave 91.6% successful readings. The mean differences between the blood pressure readings recorded by the monitor and of intermittent mercury sphygmomanometry during daytime were 0.7 (95% confidence interval -2.6 to 4.0) mmHg for the mean arterial blood pressure, -1.7 (95% confidence interval -6.8 to 3.5) mmHg for the systolic blood pressure, and 1.9 (95% confidence interval -2.2 to 6.0) mmHg for the diastolic blood pressure. The mean differences between day-time and night-time monitored blood pressures were 4.3 (95% confidence interval 0.8 to 7.8) mmHg, 4.6 (95% confidence interval 2.0 to 7.2) mmHg, and 4.4 (95% confidence interval 1.5 to 7.2) mmHg, respectively. The number of patients diagnosed as being hypertensive was similar whether automated blood pressure monitor or mercury sphymomanometry was used. Mean maternal heart rate recorded by the monitor or by the staff did not differ. Automated ambulatory blood pressure monitoring is reliable and might improve our understanding of the dynamic changes in blood pressure in pre-eclamptic women and may be a more suitable method to assess the blood pressure control achieved by different drugs.

Autoanalysis↗

[Evaluation of individual exposure to organic solvents using a portable VOC monitor].

Analysis by gas chromatograph after collection of personal samples is the most common method of evaluating individuals' exposures to organic solvents. This method provides us time-weighted averages (TWA) only, and does not measure fluctuating concentrations of organic solvents. A portable VOC monitor is widely used as a rapid screening instrument for volatile organic compounds (VOCs) in houses, schools, etc. The VOC monitor equipped with a photoionization detector can measure real-time concentrations of VOCs. In this study, the author investigated whether the VOC monitor can evaluate individuals' exposures to organic solvents. First, standard organic solvent gases were prepared and the gas concentrations were measured by a passive air sampler and the VOC monitor. Correction factors (CF) were obtained for the response of the isobutylene calibrated VOC monitor to equal concentrations of the organic solvents. Methyl ethyl ketone's CF was 0.5952, toluene's CF was 0.4418, and N,N-dimethylformamide's CF was 0.9017. Then, a mixed standard organic solvents gas was prepared and the gas concentration was measured by both methods. A significant correlation between both methods was obtained (p < 0.001). Subsequently, 37 male workers in a synthetic-leather factory were examined for solvent exposure using both the VOC and a passive sampler, Similar results were obtained by both methods (p < 0.001). Real-time data can be obtained using the VOC monitor and high exposure tasks can be identified. The VOC monitor will be useful for reducing occupational exposure. Since the VOC monitor provides detailed data of individuals' exposures to organic solvents.

Adult↗

Microstream capnography improves patient monitoring during moderate sedation: a randomized, controlled trial.

BACKGROUND: Investigative efforts to improve monitoring during sedation for patients of all ages are part of a national agenda for patient safety. According to the Institute of Medicine, recent technological advances in patient monitoring have contributed to substantially decreased mortality for people receiving general anesthesia in operating room settings. Patient safety has not been similarly targeted for the several million children annually in the United States who receive moderate sedation without endotracheal intubation. Critical event analyses have documented that hypoxemia secondary to depressed respiratory activity is a principal risk factor for near misses and death in this population. Current guidelines for monitoring patient safety during moderate sedation in children call for continuous pulse oximetry and visual assessment, which may not detect alveolar hypoventilation until arterial oxygen desaturation has occurred. Microstream capnography may provide an "early warning system" by generating real-time waveforms of respiratory activity in nonintubated patients. OBJECTIVE: The aim of this study was to determine whether intervention based on capnography indications of alveolar hypoventilation reduces the incidence of arterial oxygen desaturation in nonintubated children receiving moderate sedation for nonsurgical procedures. PARTICIPANTS AND METHODS: We included 163 children undergoing 174 elective gastrointestinal procedures with moderate sedation in a pediatric endoscopy unit in a randomized, controlled trial. All of the patients received routine care, including 2-L supplemental oxygen via nasal cannula. Investigators, patients, and endoscopy staff were blinded to additional capnography monitoring. In the intervention arm, trained independent observers signaled to clinical staff if capnograms indicated alveolar hypoventilation for >15 seconds. In the control arm, observers signaled if capnograms indicated alveolar hypoventilation for >60 seconds. Endoscopy nurses responded to signals in both arms by encouraging patients to breathe deeply, even if routine patient monitoring did not indicate a change in respiratory status. OUTCOME MEASURES: Our primary outcome measure was patient arterial oxygen desaturation defined as a pulse oximetry reading of <95% for >5 seconds. Secondary outcome measures included documented assessments of abnormal ventilation, termination of the procedure secondary to concerns for patient safety, as well as other more rare adverse events including need for bag-mask ventilation, sedation reversal, or seizures. RESULTS: Children randomly assigned to the intervention arm were significantly less likely to experience arterial oxygen desaturation than children in the control arm. Two study patients had documented adverse events, with no procedures terminated for patient safety concerns. Intervention and control patients did not differ in baseline characteristics. Endoscopy staff documented poor ventilation in 3% of all procedures and no apnea. Capnography indicated alveolar hypoventilation during 56% of procedures and apnea during 24%. We found no change in magnitude or statistical significance of the intervention effect when we adjusted the analysis for age, sedative dose, or other covariates. CONCLUSIONS: The results of this controlled effectiveness trial support routine use of microstream capnography to detect alveolar hypoventilation and reduce hypoxemia during procedural sedation in children. In addition, capnography allowed early detection of arterial oxygen desaturation because of alveolar hypoventilation in the presence of supplemental oxygen. The current standard of care for monitoring all patients receiving sedation relies overtly on pulse oximetry, which does not measure ventilation. Most medical societies and regulatory organizations consider moderate sedation to be safe but also acknowledge serious associated risks, including suboptimal ventilation, airway obstruction, apnea, hypoxemia, hypoxia, and cardiopulmonary arrest. The results of this controlled trial suggest that microstream capnography improves the current standard of care for monitoring sedated children by allowing early detection of respiratory compromise, prompting intervention to minimize hypoxemia. Integrating capnography into patient monitoring protocols may ultimately improve the safety of nonintubated patients receiving moderate sedation.

Adolescent↗

Adherence to the NASPE guideline for amiodarone monitoring at a medical university.

OBJECTIVE: Amiodarone is an effective antiarrhythmic, but the clinical usefulness of this agent is complicated by its extensive side-effect profile, which necessitates careful patient selection and frequent monitoring. The purpose of this study was to quantify adherence to published recommendations for baseline monitoring when initiating inpatient amiodarone therapy at a university teaching hospital and determine whether appropriate serial monitoring of chronic amiodarone therapy (>or= 6 months) is occurring in the outpatient setting. METHODS: A retrospective review of electronic medical records was conducted for inpatients at the Medical University of South Carolina (MUSC) who received amiodarone between November 1, 2003, and March 31, 2004, and for a subset of outpatients who had received amiodarone therapy for at least 6 months. Their medical records were reviewed for demographic data; reason for, date of initiation of, and duration of amiodarone therapy; and the occurrence of laboratory and diagnostic tests. The amiodarone guideline from the North American Society of Pacing and Electrophysiology (NASPE) was used as the measure of appropriate monitoring for baseline and follow-up chest x-rays (CXRs), liver function tests (LFTs), thyroid function tests (TFTs), and pulmonary function tests (PFTs). RESULTS: Over the 5-month period from November 1, 2003, through March 31, 2004, 277 adult patients received oral amiodarone as inpatients at MUSC. Of these, 45 patients (16%) were initiated on chronic amiodarone therapy during their hospital admission. Baseline assessments of CXRs, LFTs, and TFTs occurred in 82% to 87% of these patients. Baseline assessment of PFTs occurred in 24% of patients, and 55% of these assessments included a diffusion capacity (DLCO). Overall, only 5 (11%) of the 45 patients initiated on amiodarone received all recommended monitoring tests. Twenty patients with available outpatient records in the MUSC system were identified as receiving chronic amiodarone therapy. Baseline assessments of LFTs, TFTs, and CXRs occurred in approximately 75% to 95% of these patients; baseline assessment of PFTs occurred in <or= 30%, and 83% of these included a DLCO. Chronic monitoring at recommended time intervals for LFTs and TFTs occurred in 35% and 20% of patients, respectively, whereas annual CXRs were performed appropriately in 50% of patients. CONCLUSION: Our data suggest that opportunities exist for improved monitoring of amiodarone therapy according to the NASPE guidelines and provide support for the development of a protocol to ensure continuous amiodarone monitoring.

Academic Medical Centers↗

The way towards adverse event monitoring in clinical trials.

Different approaches to the monitoring of adverse reactions to drugs have been used over the years, with the aim of preventing catastrophes like the thalidomide episode and to rationalise drug usage. In the 1960s, the use of national and international adverse event monitoring was first suggested by the British statistician, David Finney. According to Finney, the method was well suited for the postmarketing surveillance of drugs. The idea was rejected by the World Health Organization (WHO) but was later taken up by the Prescription Event Monitoring Event System in the UK. Subsequent to problems with practolol in the 1970s it was suggested that adverse event monitoring could also be useful in clinical trials to detect adverse reactions before a drug is launched. The idea of adverse event monitoring has been tested by Astra Hässle in Sweden in clinical trials with felodipine and omeprazole, and is now the standard method within the company. Adverse event monitoring is an expensive and time-consuming method seen from a short term perspective. However, such monitoring offers an opportunity to optimise the use of clinical trials in safety monitoring, and its ability to predict possible adverse drug reactions is superior to other methods.

Adverse Drug Reaction Reporting Systems↗

Association of hiatal hernia and gastroesophageal reflux: correlation between presence and size of hiatal hernia and 24-hour pH monitoring of the esophagus.

OBJECTIVE: The relationship of hiatal hernia to gastroesophageal reflux disease remains controversial. Previous endoscopic and radiologic studies of hiatal hernia and reflux esophagitis have shown that hiatal hernia is a poor predictor of the presence of endoscopic esophagitis, especially for smaller hernias. Similar correlations with 24-hr pH monitoring have not been done. The purpose of this study was to determine if there is a correlation between the presence and size of hiatal hernias and gastroesophageal reflux using 24-hr pH monitoring as a measure of the degree of reflux. MATERIALS AND METHODS: We reviewed the barium esophagograms and the results of pH monitoring of the esophagus in 319 patients (161 women and 158 men; mean age, 51 years). The presence and size of hiatal hernia were determined from the radiographic examination; size was categorized as "minimal" or "larger" (> or = 2 cm axial length). An abnormal result of pH monitoring was defined as a pH less than 4 for 6% or more of the 24-hr observation time. RESULTS: Abnormal results of pH monitoring were found in 61 (31%) of 199 patients with hiatal hernia compared with 21 (18%) of 120 patients without hiatal hernia (p < .05). Abnormal findings of pH monitoring were present in 33 (35%) of 95 patients with a larger hiatal hernia versus 28 (27%) of 104 patients with a minimal hiatal hernia (p > .05); a significant difference (p < .05) was observed when patients without hiatal hernia were compared with those with a larger hiatal hernia. CONCLUSION: Most patients in this study had normal results of pH monitoring of the esophagus regardless of the presence or absence of hiatal hernia. However, patients with larger hiatal hernias were more likely to have abnormal findings on pH monitoring; hiatal hernias of minimal size were a poorer predictor of the presence of abnormal gastroesophageal reflux.

Esophagus↗

Self-monitoring of blood glucose by adults with diabetes in the United States population.

OBJECTIVE: To evaluate self-monitoring of blood glucose, which is considered an important practice for patients with diabetes. However, little is known about the frequency or determinants of this technique. RESEARCH DESIGN AND METHODS: A detailed questionnaire on diabetes was administered to a representative sample of 2405 diabetic subjects > or = 18 yr of age in the U.S. population in the 1989 National Health Interview Survey. RESULTS: Among subjects with IDDM, 40% monitored their blood glucose at least 1 time/day. Among subjects with NIDDM treated with insulin, 26% monitored at least 1 time/day and among NIDDM subjects not treated with insulin, the percentage was 5%. When stratified by age, little difference was observed between IDDM subjects and insulin-treated NIDDM subjects in the percentage testing at least 1 time/day. By multivariate analysis, age and insulin use were the major determinants of whether diabetic subjects tested their blood glucose. Race and education were also independently related to self-monitoring of blood glucose. Blacks were 60% less likely to test their blood glucose at least 1 time/day compared with non-Hispanic whites and Mexican Americans. Those with college education were 80% more likely to test their blood glucose compared with those with lower education levels. Having had a patient education class in diabetes management and frequent physician visits for diabetes care were positively related to self-testing. Self-monitoring was not related to higher income or having health insurance. CONCLUSIONS: A large proportion of patients with diabetes do not test their blood glucose. Financial barriers associated with income and health insurance do not appear to impede the practice of self-monitoring. Because of the importance of blood glucose control in the prevention of diabetes complications and the role of self-monitoring in achieving blood glucose control, it may be prudent for physicians and their patients to make greater use of this technique. Special attention should be directed to the subgroups of patients (blacks, patients not treated with insulin, those with less education, and those with no education in diabetes) in which the frequency of self-monitoring is particularly low.

Adult↗

Frequency of blood glucose monitoring in relation to glycemic control in patients with type 2 diabetes.

OBJECTIVE: The aim of the study was to investigate the relationship between blood glucose level, measured as HbA(1c), and frequency of self-monitoring in patients with type 2 diabetes. Daily self-monitoring is believed to be important for patients treated with insulin or oral agents to detect asymptomatic hypoglycemia and to guide patient and provider behavior toward reaching blood glucose goals. RESEARCH DESIGN AND METHODS: A national sample of patients with type 2 diabetes was studied in the third National Health and Nutrition Examination Survey. Data on therapy for diabetes, frequency of self-monitoring of blood glucose, and HbA(1c) values were obtained by structured questionnaires and by clinical and laboratory assessments. RESULTS: According to the data, 29% of patients treated with insulin, 65% treated with oral agents, and 80% treated with diet alone had never monitored their blood glucose or monitored it less than once per month. Self-monitoring at least once per day was practiced by 39% of those taking insulin and 5-6% of those treated with oral agents or diet alone. For all patients combined, the proportion of patients who tested their blood glucose increased with an increasing HbA(1c) value. However, when examined by diabetes therapy category, there was little relationship between HbA(1c) value and the proportion testing at least once per day or the proportion testing at least once per week. CONCLUSIONS: In this cross-sectional study of patients with type 2 diabetes, the increase in frequency of self-monitoring of blood glucose with increasing HbA(1c) value was associated with the higher proportion of insulin-treated patients in higher HbA(1c) categories. Within diabetes therapy categories, the frequency of self-monitoring was not related to glycemic control, as measured by HbA(1c) level.

Blood Glucose↗

Assessment of oscillometric non-invasive blood pressure monitors using the Dynatech Nevada CuffLink analyser.

The assessment of the functional performance of non-invasive blood pressure (NIBP) monitors using a commercially available NIBP analyser (Dynatech CuffLink) was evaluated. The CuffLink includes facilities for performing a static pressure calibration, and safety cut-out pressure, leak rate and rapid deflate time measurements. Cuff pressure oscillations simulating a range of blood pressures at a range of heart rates enable dynamic tests of NIBP monitors to be performed. By reducing the magnitude of the cuff pressure oscillations the sensitivity of a monitor to weak pulsations can be determined. The CuffLink does not provide facilities for assessing the ability of the monitor to reject movement artifact. The CuffLink tests were performed on 10 different models of NIBP monitor. The results demonstrate the variable nature of systolic, diastolic and mean blood pressure readings from NIBP monitors (even under stable laboratory conditions), reinforcing the importance of not relying on individual readings, but rather to consider the average of a few successive readings. Normative data for two models of NIBP monitor are provided. Applications of the CuffLink are discussed with reference to a protocol for NIBP monitor performance checks.

Artifacts↗

Reduced mortality rate in patients with severe traumatic brain injury treated with brain tissue oxygen monitoring.

OBJECT: An intracranial pressure (ICP) monitor, from which cerebral perfusion pressure (CPP) is estimated, is recommended in the care of severe traumatic brain injury (TBI). Nevertheless, optimal ICP and CPP management may not always prevent cerebral ischemia, which adversely influences patient outcome. The authors therefore determined whether the addition of a brain tissue oxygen tension (PO2) monitor in the treatment of TBI was associated with an improved patient outcome. METHODS: Patients with severe TBI (Glasgow Coma Scale [GCS] score < 8) who had been admitted to a Level I trauma center were evaluated as part of a prospective observational database. Patients treated with ICP and brain tissue PO2 monitoring were compared with historical controls matched for age, pathological features, admission GCS score, and Injury Severity Score who had undergone ICP monitoring alone. Therapy in both patient groups was aimed at maintaining an ICP less than 20 mm Hg and a CPP greater than 60 mm Hg. Among patients whose brain tissue PO2 was monitored, oxygenation was maintained at levels greater than 25 mm Hg. Twenty-five patients with a mean age of 44 +/- 14 years were treated using an ICP monitor alone. Twenty-eight patients with a mean age of 38 +/- 18 years underwent brain tissue PO2-directed care. The mean daily ICP and CPP levels were similar in each group. The mortality rate in patients treated using conventional ICP and CPP management was 44%. Patients who also underwent brain tissue PO2 monitoring had a significantly reduced mortality rate of 25% (p < 0.05). CONCLUSIONS: The use of both ICP and brain tissue PO2 monitors and therapy directed at brain tissue PO2 is associated with reduced patient death following severe TBI.

Adult↗

Complications of intracranial pressure monitoring in children with head trauma.

OBJECT: Intracranial pressure (ICP) monitoring has become routine in the management of patients with traumatic brain injury (TBI). Many surgeons prefer to use external ventricular drains (EVDs) over fiberoptic monitors to measure ICP because of the added benefit of cerebrospinal fluid drainage. The purpose of this study was to examine a consecutive series of children with TBI and compare the incidence of complications after placement of an EVD, a fiberoptic intraparencyhmal monitor, or both. METHODS: A retrospective chart review was conducted to identify children with TBI who met the criteria for insertion of an ICP monitor. All patients underwent head CT scanning on admission and after placement of an ICP monitor. During a 5-year period 80 children met the criteria for inclusion in the study. Eighteen children (22.5%) underwent EVD placement only, 18 (22.5%) underwent placement of a fiberoptic device only, and 44 (55%) received both. A total of 62 fiberoptic devices (48%) were inserted, and 68 EVDs (52%) were placed. Overall, there was a fourfold increased risk of complications in children who received an EVD compared with those in whom a fiberoptic monitor was placed (p = 0.004). Hemorrhagic complications were detected in 12 (17.6%) of 62 patients who received an EVD compared with four (6.5%) of 62 patients who received a fiberoptic monitor (p = 0.025). Six (8.8%) of 68 EVDs were malpositioned and required replacement; in three (50%) of these cases a hemorrhagic complication occurred. Only one infection was noted in a patient with an EVD (1.5%). CONCLUSIONS: In this retrospective cohort of pediatric patients with TBI, complication rates were significantly higher in those receiving EVDs than in those in whom fiberoptic monitors were placed. Although the majority of these complications did not entail clinical sequelae, surgeons should be aware of the different complication rates when choosing the most appropriate device for each patient.

Adolescent↗

Issues in data monitoring and interim analysis of trials.

OBJECTIVES: To address issues about data monitoring committees (DMCs) for randomised controlled trials (RCTs). DATA SOURCES: Electronic databases. Handsearching of selected books. Personal contacts with experts in the field. REVIEW METHODS: Systematic literature reviews of DMCs and small group processes in decision-making; sample surveys of: reports of RCTs, recently completed and ongoing RCTs and policies of major organisations involved in RCTs; case studies of four DMCs; and interviews with experienced DMC members. All focused on 23 prestated questions. RESULTS: Although still a minority, RCTs increasingly have DMCs. There is wide agreement that nearly all trials need some form of data monitoring. Central to the role of the DMC is monitoring accumulating evidence related to benefit and toxicity; variation in emphasis has been reflected in the plethora of names. DMCs for trials performed for regulatory purposes should be aware of any special requirements and regulatory consequences. Advantages were identified for both larger and smaller DMCs. There is general agreement that a DMC should be independent and multidisciplinary. Consumer and ethicist membership is controversial. The chair is recognised as being particularly influential, and likely to be most effective if he or she is experienced, understands both statistical and clinical issues, and is facilitating in style and impartial. There is no evidence available to judge suggested approaches to training. The review suggested that costs should be covered, but other rewards must be so minimal as to not affect decision-making. It is usual to have a minimum frequency of DMC meetings, with evidence that face-to-face meetings are preferable. It is common to have open sessions and a closed session. A report to a DMC should cover benefits and risks in a balanced way, summarised in an accessible style, avoiding excessive detail, and be as current as possible. Disadvantages of blinded analyses seem to outweigh advantages. Information about comparable studies should be included, although interaction with the DMCs of similar ongoing trials is controversial. A range of formal statistical approaches can be used, although this is only one of a number of considerations. DMCs usually reach decisions by consensus, but other approaches are sometimes used. The general, but not unanimous, view is that DMCs should be advisory rather than executive on the basis that it is the trial organisers who are ultimately responsible for the conduct of the trial. CONCLUSIONS: Some form of data monitoring should be considered for all RCTs, with reasons given where there is no DMC or when any member is not independent. An early DMC meeting is helpful, determining roles and responsibilities; planned operations can be agreed with investigators and sponsors/funders. A template for a DMC charter is suggested. Competing interests should be declared. DMC size (commonly three to eight people) is chosen to optimise performance. Members are usually independent and drawn from appropriate backgrounds, and some, particularly the chair, are experienced. A minimum frequency of meetings is usually agreed, with flexibility for more if needed. The DMC should understand and agree the statistical approach (and guidelines) chosen, with both the DMC statistician and analysis statistician competent to apply the method. A DMC's primary purpose is to ensure that continuing a trial according to its protocol is ethical, taking account of both individual and collective ethics. A broader remit in respect of wider ethical issues is controversial; arguably, these are primarily the responsibility of research ethics committees, trial steering committees and investigators. The DMC should know the range of recommendations or decisions open to it, in advance. A record should be kept describing the key issues discussed and the rationale for decisions taken. Errors are likely to be reduced if a DMC makes a thorough review of the evidence and has a clear understanding of how it should function, there is active participation by all members, differences are resolved through discussion and there is systematic consideration of the various decision options. DMCs should be encouraged to comment on draft final trial reports. These should include information about the data monitoring process and detail the DMC membership. It is recommended that groups responsible for data monitoring be given the standard name 'Data Monitoring Committee' (DMC). Areas for further research include: widening DMC membership beyond clinicians, trialists and statisticians; initiatives to train DMC members; methods of DMC decision-making; 'open' data monitoring; DMCs covering a portfolio of trials rather than single trials; DMC size and membership, incorporating issues of group dynamics; empirical study of the workings of DMCs and their decision-making, and which trials should or should not have a DMC.

Clinical Trials Data Monitoring Committees↗

Lipid monitoring in patients with schizophrenia prescribed second-generation antipsychotics.

OBJECTIVES: Treatment with second-generation antipsychotic (SGA) medications has been linked with increased rates of the metabolic syndrome (i.e., dyslipidemia, obesity, and hyperglycemia). Several sets of published recommendations now provide clinicians with guidelines for monitoring metabolic parameters in individuals with schizophrenia treated with SGAs. However, few data are available regarding actual metabolic monitoring practices in this patient population. The objectives of the study were to determine baseline lipid monitoring rates for individuals with schizophrenia prescribed SGAs during the period prior to the publication of monitoring guidelines and to determine whether individuals with abnormal lipid levels received follow-up monitoring sooner than individuals with normal levels. METHOD: Lipid monitoring rates for 408 individuals with schizophrenia who were prescribed SGAs from October 1999 to October 2003 were examined using administrative data from a Veterans Affairs facility. Survival analysis was used to examine time to follow-up lipid measurement and to compare time to follow-up measure for individuals with normal initial lipid levels versus those with elevated initial lipid levels. RESULTS: Eighty-five percent of individuals had at least 1 measurement for total cholesterol or triglycerides in a 4-year period. Abnormal initial measurements predicted significantly earlier follow-up monitoring (p < .005 for total cholesterol, p < .05 for triglycerides, p < .001 for low-density lipoprotein cholesterol). However, median time to follow-up measure was 304 days (approximately 10 months) for individuals with elevated total cholesterol levels, which is too long for optimal clinical follow-up. CONCLUSION: Program managers and clinicians should assess adequacy of monitoring and support quality improvement initiatives in this area.

Antipsychotic Agents↗

[Biological monitoring of exposure to industrial toxic substances. Present-day situation and prospects for development].

Biological monitoring of exposure to an industrial chemical may be defined as the evaluation of the internal dose (internal exposure) by a biological method with the view of assessing the associated health risk. Depending on the biological parameter selected and on the time of sampling, internal dose may mean the amount of chemical recently absorbed, the amount stored in one or several compartments of the organism, or, under ideal conditions, the amount bound to the sites of action. The estimation of the internal dose has usually relied on two categories of tests: those based on the determination of the chemical and/or its metabolites in various biological media (eg, alveolar air, blood, urine) and those based on the quantification of a nonadverse biological effect, the intensity of which is related to the internal dose. Biological tests providing information on the amount of active chemical bound to the critical sites of action (target dose) and noninvasive analytical methods which measure the amount of cumulative toxins stored in certain body compartments (eg, bone, liver, kidney) are currently being developed. The main criteria to be considered in the selection of the most appropriate biological monitoring test of exposure are the specificity of the parameter and its sensitivity with respect to the exposure level, the analytical and biological applicability, the convenience for the workers, the possible risks associated with its application, and, of course, the accuracy of the exposure and/or health risk evaluation. Normally, the biological approach of exposure monitoring is reserved for chemicals which enter the organism and may exert systemic toxic effects. When a biological monitoring test of exposure is applicable, it offers several advantages over ambient air monitoring. A biological parameter reflecting the internal dose is necessarily more closely related to the systemic adverse effect(s) than any environmental measurement. Biological monitoring of exposure integrates the exposure by all routes (pulmonary, oral, and cutaneous) and sources. It may also take into account several factors which determine the uptake and the absorption of the chemical (individual variability, work load, hygiene habits, etc). However, contrary to ambient monitoring, biological monitoring is applicable only when sufficient information has been gathered on the metabolism of the chemical, its toxicity or that of its metabolites, and when some of the relationships between external exposure, internal dose and adverse effects have been assessed.(ABSTRACT TRUNCATED AT 400 WORDS)

Humans↗

Audit of transfusion procedures in 660 hospitals. A College of American Pathologists Q-Probes study of patient identification and vital sign monitoring frequencies in 16494 transfusions.

CONTEXT: Hemolytic transfusion reactions are often the result of failure to follow established identification and monitoring procedures. OBJECTIVE: To measure the frequencies with which health care workers completed specific transfusion procedures required for laboratory and blood bank accreditation. DESIGN: In 2 separate studies, participants in the College of American Pathologists Q-Probes laboratory quality improvement program audited nonemergent red blood cell transfusions prospectively and completed questionnaires profiling their institutions' transfusion policies. SETTING AND PARTICIPANTS: A total of 660 institutions, predominantly in the United States, at which transfusion medicine services are provided. MAIN OUTCOMES MEASURES: The percentages of transfusions for which participants completed 4 specific components of patient and blood unit identifications, and for which participants monitored vital signs at 3 specific intervals during transfusions. RESULTS: In the first study, all components of patient identification procedures were performed in 62.3%, and all required patient vital sign monitoring was performed in 81.6% of 12 448 transfusions audited. The median frequencies with which institutions participating in the first study performed all patient identification and monitoring procedures were 69.0% and 90.2%, respectively. In the second study, all components of patient identification were performed in 25.4% and all patient vital sign monitoring was performed in 88.3% of 4046 transfusions audited. The median frequencies with which institutions participating in the second study performed all patient identification and monitoring procedures were 10.0% and 95.0%, respectively. Individual practices and/or institutional policies associated with greater frequencies of patient identification and/or vital sign monitoring included transporting units of blood directly to patient bedsides, having no more than 1 individual handle blood units in route, checking unit labels against physicians' orders, having patients wear identification tags (wristbands), reading identification information aloud when 2 or more transfusionists participated, using written checklists to guide the administration of blood, instructing health care personnel in transfusion practices, and routinely auditing the administration of transfusions. CONCLUSIONS: In many hospitals, the functions of identification and vital sign monitoring of patients receiving blood transfusions do not meet laboratory and blood bank accreditation standards. Differences in hospital transfusion policies influence how well health care workers comply with standard practices. We would expect that efforts designed to perfect transfusion policies might also improve performance in those hospitals in which practice compliance is substandard.

Accreditation↗

Invasive and non-invasive physiological monitoring of blunt trauma patients in the early period after emergency admission.

Pulmonary artery catheterization is usually not available to critically injured patients before admission to the intensive care unit, where action to correct values derived from such monitoring may be too late. Methods allowing hemodynamic monitoring during the early stages after trauma need to be explored. We used non-invasive monitoring systems (bioimpedance cardiac output monitoring, pulse oximetry and transcutaneous oximetry) to evaluate early temporal hemodynamic patterns after blunt trauma, and compared these to invasive PA monitoring. We included prospectively 134 patients monitored shortly after admission to the emergency department. The non-invasive impedance cardiac output estimations under extenuating emergency conditions approximated those of the thermodilution method: r = 0.83, r2 = 0.69, P<0.001; bias and precision were -0.02+/-0.78 l/min/m2. In the intensive care unit, these values improved further to: r = 0.91, r2 = 0.83, P<0.001; bias and precision = 0.36+/-0.59 l/min/m2. Monitoring revealed episodes of hypotension, low cardiac index, arterial hemoglobin desaturation, low transcutaneous oxygen and high transcutaneous carbon dioxide tensions, and low oxygen consumption during initial resuscitation. Low flow and poor tissue perfusion were more pronounced in non-survivors by both methods. Multicomponent non-invasive monitoring systems give continuous on-line, real-time displays of physiological data that allow early recognition of circulatory dysfunction. Such systems provide information similar to that provided by the invasive thermodilution method, and are easier and safer to use.

Adult↗