Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Knee Prosthesis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58Linked to original sources

[Complications from the hinged GUEPAR prosthesis after resection of knee tumor. 102 cases].

PURPOSE: The purpose of this study was to present the complications which occurred in knee replacement with the GUEPAR prosthesis, after bone tumor resection. We tried to point out complications in relation to prosthetic design and surgical technique. MATERIAL AND METHOD: Between 1972 and 1993, 90 patients had a knee resection, for 80 malignant and 10 benign tumors. There were 51 males and 49 females, aged 12 to 75 years (mean age 35). Fifty-six distal femur resections and 34 proximal tibial resections were performed. Length of resection averaged 16 cm (9 to 30). The reconstruction was always achieved with a cemented, custom-made GUEPAR prosthesis. Including revisions, there was a total of 102 prostheses in 90 patients. A patellar resurfacing was performed in 64 cases. An allograft reconstruction was associated in 39 knees. In all tibial resections and in two extra-articular femoral resections, the extensor mechanism had to be reconstructed. Several reconstruction techniques were associated, in which 19 medial gastrocnemius transfers. The prosthesis design was slightly modified with time. Ten patients received radiotherapy, and 55 had chemotherapy. RESULTS: Results and complications were retrospectively assessed, with an average follow-up of 4.3 years (1 to 22). Six patients were lost for follow-up, 62 patients were alive, with no evolutive disease, 13 had an evolutive disease and 10 were deceased from disease. Nineteen patients had distant metastasis and 17 had local recurrences. Apart from intraoperative complications, late mechanical complications included: 13 aseptic loosening, 2 femoral shaft fractures, 18 knee contractures, 5 femoral stem fractures and, 18 intra-articular instabilities related to wear of the hinge-axis. In the 39 allograft-composite prostheses, only 15 had a favorable evolution. There were 15 extensor mechanism failures and 13 knees had persistent infection. There was a total of 94 reoperations in the 90 patients. In 28 cases, the initially implanted prosthesis was removed. There were also 18 revisions, 7 amputations and 3 arthrodeses. Survivorship analysis showed a 60 per cent probability for the initial prosthesis not to be revised at 10 year-follow-up, apart from oncologic complications. DISCUSSION: Results with allograft-composite reconstruction were not better than with massive prosthesis. When needed, soft tissue coverage and patellar tendon augmentation would better be performed with gastrocnemius plasty. Polyethylene and steel bushes were not solution for hinge axis wear.

Actuarial Analysis↗

[The use of total cementless threaded knee Motta-Callea prosthesis].

The paper presents features and operative technique for Motta-Callea knee arthroplasty. Medium-term results in a series of 17 joints with serious osteoarthritis (stage IV and V--classification of Larsen at al) in 14 patients aged 43-75 years (mean 64 years) are presented. Patients were evaluated according to Clinical Rating System (Insall et al.) before and after surgery. The average total score tripled after operation and was 168 of 200 points available. Good results have been achieved in both younger and elderly patients with advanced osteoarthritis and osteoporosis, also with bone plasty for varus or valgus deformity. An improvement was noted in regard of pain, alignment of the knee, its sagittal stability and walking ability, stairs included.

Adult↗

Proven and nonproven facts in knee arthroplasty. Results with the semiconstrained GSB-prosthesis.

The great number of knee-replacement systems makes a comparative study difficult. Even more confusing are the different criteria used for the evaluation of the results. After a critical review of what can be taken as proven facts, our own experience with the semiconstrained GSB-III knee prosthesis is critically analyzed. The survivorship method is used, presenting the cumulative success rate and analyzing the reasons for the failure rates. We feel that all authors presenting results of knee arthroplasty should adopt this method, using the same or at least comparable evaluation sheets (for instance, that of ERASS). Moreover, more attention should be given to bone dynamics in a prospective study using modern technology (CT densitometry). This will help to detect possible factors responsible for the failure of knee arthroplasty and possibly to prevent failure with medication.

Biomechanical Phenomena↗

Improved range of flexion after total knee arthroplasty. The total condylar knee versus the KU knee.

One objective of the modification of the total condylar knee is to increase the range of flexion without compromising the durability of the prosthesis. The KU knee prosthesis was designed to improve postoperative range of motion. This prosthesis has a unique ball-and-socket joint in the center of the posterior portion of the femorotibial articulation. A retrospective comparative study was undertaken to determine whether the KU knee prosthesis had achieved its design objectives. The study was based on the clinical observation of two populations: one (the TC group: 31 joints) with total condylar prostheses and the other (the KU group; 31 joints) with KU knee prostheses. At two years postoperatively, the mean postoperative range of flexion was 94 degrees (range: 60 degrees to 120 degrees) in the TC group and 120 degrees (range: 95 degrees to 150 degrees) in the KU group. The mean postoperative range of flexion was 24 degrees better in the KU group than in the TC group (p < 0.01). The mean functional score was 76 points (range: 61 to 86) in the TC group and 81 points (range: 56 to 92) in the KU group. There were no statistically significant difference in pain, walking ability, deformity, extension lag, and activities of daily living (ADL) score between the two groups. However, a statistically significant difference was detected in the range of motion (ROM) score (p < 0.01). No major complications occurred in either of the two groups. Although the follow-up period was not long enough, the KU knee was thought to be a promising modification of the total condylar knee prosthesis.

Activities of Daily Living↗

The possibility of distal embolization from a femoral-popliteal prosthesis above the knee. A consideration against its routine use in this position.

The preferential use of a synthetic arterial graft in the above-knee femoral-popliteal position is advocated by many surgeons for a variety of reasons. Our recent experience with three cases of substantial deterioration of runoff vessels within a brief period, which may have resulted from embolization from such a conduit, is presented along with other arguments against the routine use of a prosthesis in this position. The procedure with the best possible outcome, namely, one utilizing autogenous vein, should be performed at the outset in all patients except those with a limited life expectancy or those in whom a lengthy procedure would be hazardous.

Adult↗

[Testing the usefulness of a provisional polyester prosthesis for augmentation in reconstructive operations of knee joint ligaments].

Prosthesis from polyester fibres 5 mm wide with loose knitting finished on both ends with teflon handles for fixing bones with a wholly aphid screw made by Tricomed company in Lódź according to its own idea was the subject of the test. The tests were made on 7 piglets. The prosthesis together with an autogenic graft taken from the middle third of a patella ligaments was implanted into the place of the excised front sacral ligament. The implanted prosthesis was characterised with a high biocompatibility, satisfying mechanical resistance and easiness of fixing of the tested graft. We noticed clinically and pertaining to autopsy the possibility of removing the allogenic graft after achieving the full healing of the autogenic graft without the possibility of hurting that last one.

Animals↗

Analysis of a below-knee patellar tendon-bearing prosthesis: a finite element study.

In this study, a finite element (FE) model of a below-knee prosthesis of patellar tendon-bearing (PTB) design, and several altered variations of the model have been constructed. A load of approximately 1.5 times normal body weight (984 N) was applied at the heel of the model to simulate heelstrike conditions. The "base" model was then analyzed and revised iteratively until a model which provided consistency between soft tissue elastic modulus and socket displacement was developed. The interface normal and shear stresses obtained from the analysis of this revised base model were highest (about 961, and 463 KPa, respectively) at the distal anterior tip of the socket/stump. Proximally, higher normal stresses (72-78 KPa) were found medially and posteriorly. Proximal shear stresses were highest posteriorly (79 KPa), although shear stresses medially (51 KPa), and laterally (43 KPa), were also much higher than anteriorly (10 KPa). FE analyses were performed on the altered models to determine the relative effects on socket/stump interface stresses of altering the FE model of the prosthesis. Results of the analysis indicate that fabricating the prosthesis from a material with an elastic modulus ten times lower than that of the revised base model can produce reductions in the maximum pressure of up to 14 percent. Large decreases in maximum pressures (71 percent) resulted from the use of a suction socket rather than a conventional socket. Small changes in stump length (2 cm) caused relatively large pressure changes (16 to 18 percent).

Amputation, Surgical↗

[Epitheloid osteosarcoma. Differential diagnostic problems].

The case of a 23-year-old female patient suffering from a rare variety of osteosarcoma of the distal femur with epithelial differentiation and only traces of osteoid is reported. The tumour cells reacted strongly to antibodies against vimentin. Metastases were found in the fifth rib and the right kidney. There was no response to chemotherapy. One year after implantation of a tumour prosthesis of the knee a thigh amputation was necessary because of a local failure. The patient died 2.5 years after the tumour had initially been diagnosed. Other reports of this rare type of epitheloid osteosarcoma illustrate the difficulties involved in reaching a correct diagnosis. This tumour can be mistaken for a skeletal metastasis of an epithelial tumour.

Adult↗

[Materials and shapes: the compromise].

The development and fabrication of a prosthesis of the knee which for many years will fulfil the functions of a normal knee result from a very complex compromise between materials and shapes. It is essential to select materials and shapes whose characteristics are complying with the specifications laid down for this particular arthroplasty. Materials ans shapes must in the long term be able to solve all the problems of biomechanics, flow, wear, friction and fixation to the osseous elements, without underestimating the interactions between implant and biological environment which may result in deterioration of the bone-implant interface.

Biocompatible Materials↗

Prosthetic resurfacing of the patella.

Accumulated data from many sources seem to indicate that prosthetic resurfacing of the patella may be an acceptable alternative to patellectomy in the treatment of chondromalacia patellae or patellofemoral arthrosis. A patellar prosthesis which is made of cobalt-chromium alloy is attached to a remnant of the original patella by means of the acrylic cement, polymethyl methacrylate. An analysis fo the results of the use of this prosthesis in 14 knees of 13 patients reveals excellent or good results in 13 cases and one poor result. The longest follow-up period was 2 years and 9 months and the shortest was 6 weeks. Based on current experience and the experience of others, prosthetic resurfacing of the patella may give the patient some years of pain-free patellofemoral function. This is especially true in patients with poor quadriceps reserve in whom the lever-arm distance of the extensor torque should be maiwtained. Until the ideal resurfacing material is developed, the use of presently available patellar prostheses with or without femoral prosthetic components, is recommended for further investigation.

Adolescent↗

Total knee arthroplasty in valgus knees.

One hundred thirty-four total knee arthroplasties in 98 patients with a valgus alignment were analyzed. Knees with a preoperative alignment of 10 degrees or greater anatomic valgus were believed suitable for inclusion. The average follow-up period in these patients was 4.5 years (range, two to ten years). One hundred eighteen knees were implanted with a posterior stabilized prosthesis, eight knees with a constrained implant design, four knees with a total condylar prosthesis, and four knees with a cruciate-retaining design. All components in all knees were cemented. A lateral retinacular release was necessary in 76% of the arthroplasties secondary to intraoperative lateral subluxation of the patella. The ligamentous release for balancing these valgus-deformed knees was done from the femur. There were 95 knees (71%) rated as excellent, 27 knees (20%) as good, eight knees (6%) as fair, and four knees (3%) as poor. Postoperatively, 76% of the knees had a tibiofemoral alignment between 5 degrees and 9 degrees valgus with an overall average of 7 degrees valgus (range, 3 degrees varus to 15 degrees valgus). Total knee arthroplasty is a reliable and durable procedure in the treatment of valgus knee arthritis. However, valgus-deformed knees represent a greater challenge than their varus counterparts to the implant surgeon in terms of the intraoperative balancing required. This may be a function of the greater difficulty in achieving ligamentous equilibrium and the relative rarity of valgus-deformed knees.

Adult↗