The dermal-flap canthal lift for lower eyelid support. A technique of value in the surgical treatment of facial palsy.
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Measurements of lower eyelid length were completed to determine if the length of the lower eyelid increased with advancing age. The results support the that the lower eyelid indeed does not get longer with aging. In two groups of 100 patients each, at either end of the adult age spectrum, there were no statistical differences in the lengths of the lower eyelids. Our data support the concept that the lateral canthal tendon stretches with advancing age and allows the lateral canthus to drift medially, thus allowing for shortening of the horizontal palpebral fissure and contributing to the marked laxity of the lower eyelids often seen in older individuals. More attention should be paid to this etiologic factor in the surgical correction of lower eyelid laxity.
Contracture following the successful take of a split-thickness cutaneous graft may be difficult to avoid if a force opposite to the contraction cannot be applied. In this paper, a procedure is described in which a wire-frame buried around the graft maintains it expanded during the contractile period.
Lower lid stability can be affected by many conditions involving the lid directly, e.g. facial palsy, facial clefts, trauma, or tumors. Secondary stretching due to a poorly fitting orbital prosthesis can have the same effect. In 41 such eyelids, stability was obtained by inserting a large cartilage graft sutured to the tarsal plate and the infraorbital rim. Thirteen patients had tarsoconjunctival wedge resections, and 10 had lateral canthopexies performed at the same procedure. One graft was too small and was later replaced. There was one hematoma, which was evacuated. There were no other lid or visual problems. The follow-up is short, 21 months maximum, but so far the results are very satisfactory.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
There are many methods to repair facial skin defects in clinical practice. The desired outcome for the surgeon and the patient is the restoration of facial appearance and function. The temporal region is one of the ideal donor sites for the repair of a facial skin defect, because this area is relatively inconspicuous and the skin quality is similar to that of the face. In the past, the temporal region was always used as the donor site of the local flap for repairing the facial skin defect. Because the blood supply of the skin comes from the subjacent tissue mainly rather than from the contiguous tissue, the pedicles of the local flaps are short, limiting the use of this area as a donor site. From 1993 to 1996, the anatomy of the orbicularis oculi myocutaneous flap in five cadavers was studied; what was learned allowed for the use of this flap to repair skin defects of the face in 13 patients. In this paper, the clinical experiences using the orbicularis oculi myocutaneous flaps to repair skin defects of the face and the surgical anatomy of this myocutaneous flap are discussed.
Lower eyelid retraction is a common complication after cosmetic surgery of the lower eyelids, midface, and the adjacent face. Lower eyelid retraction is defined as the inferior malposition of the lower eyelid margin without eyelid eversion. Lower eyelid retraction presents clinically with scleral show; round, sad-looking eyes; lateral canthal tendon laxity; and symptoms of ocular irritation, including photophobia, excessive tearing, and nocturnal lagophthalmos. These patients frequently require ocular lubricants, including artificial tears and ointments, which often provide only minimal alleviation of their symptoms. The author has observed that lower eyelid retraction is usually accompanied by midface descent. On the basis of surgical observations, the causes of lower eyelid retraction seem to be multifactorial and include scarring between the orbital septum and capsulopalpebral fascia (or lower eyelid retractors), lateral canthal tendon laxity, and midface descent. After describing the causes of lower eyelid retraction, the author presents a system for evaluating patients that can assist the surgeon in choosing the surgical procedure(s) required to correct the lower eyelid malposition. The surgeon must know how to tighten a lax lateral canthal tendon, be familiar with the anatomy of the lower eyelid from conjunctiva to skin side, and know how to surgically elevate the midface. The techniques for correcting lower eyelid retraction are also presented. Appropriate surgery, which is determined on the basis of the preoperative evaluation, has allowed for the correction of these previously difficult-to-treat lower eyelid malpositions with minimal complications.
Explore the source record for details and available documents.
PURPOSE: To evaluate the use of computer-assisted volumetric measurement for the prediction of late enophthalmos and for volume estimation of implant material in the correction of late enophthalmos secondary to orbital blowout fractures (BOF). METHODS: This is a prospective observational study of 16 patients. Computer-assisted orbital volume measurements were made with the use of axial CT scans. Hertel exophthalmometry was used for the measurement of enophthalmos. The Lancaster test was used for measurement of diplopia. Autogenous bone or hydroxyapatite composite material was used for the repair of orbital defects and the correction of orbital volume expansion in 16 patients with enophthalmos caused by BOF. The volume of implant material was calculated from the orbital volume increment. Patients were followed for an average of 8 months after surgery. RESULTS: There is a high correlation between the increment of orbital volume and the degree of enophthalmos; 1 cm3 orbital volume increment causes 0.89 mm of enophthalmos. Before surgery, 10 of the 16 patients had moderate enophthalmos (3 to 4 mm) and 6 patients had severe enophthalmos (> or = 5 mm). Six months after surgical intervention, 13 patients (81%) achieved satisfactory results; 3 patients had no enophthalmos and 10 had mild enophthalmos (1 to 2 mm). Three patients had moderate to severe enophthalmos. CONCLUSIONS: The measurement of orbital volume in patients with BOF can be used to predict the degree of late enophthalmos. Use of the orbital volume increment to determine the amount of implant material can improve the therapeutic outcome in the correction of late enophthalmos caused by BOF.
PURPOSE: To determine the range of plasma leptin levels in patients with floppy eyelid syndrome (FES). METHODS: This was a retrospective, noninterventional case series of 11 patients with FES. Charts were reviewed for patient age, sex, plasma leptin level, body mass index (BMI), presence or absence of obstructive sleep apnea (OSA) and diabetes mellitus, and any treatments for OSA. RESULTS: Charts of 11 patients were reviewed (10 male, 1 female). Plasma leptin levels were elevated in 7 of 11 patients (64%). Mean plasma leptin concentration was 49.5 ng/ml in male patients (range, 5 to 120 ng/ml) compared with a normal range of 1 to 35 ng/ml. Plasma leptin level in the female patient was 180 ng/ml (normal range, 4 to 72 ng/ml). Five patients had a known diagnosis of OSA. Four of these patients received continuous positive airway pressure during leptin level measurement. Plasma leptin levels averaged 110.0 ng/ml in the continuous positive airway pressure group. Average BMI was 37.4 kg/m (range, 24.9 to 57.1 kg/m). All patients with elevated leptin levels had a high BMI. CONCLUSIONS: Patients with FES demonstrate elevated plasma leptin levels, which correlate with BMI. Hyperleptinemia may play a role in the pathogenesis of FES.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.