Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “DISINFECTANTS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58Linked to original sources

Suitability of a propanolic PVP-iodophor preparation as preoperative skin disinfectant: germicidal activity and chemical stability.

The preparation Solutio Betadini propanolica 3% w/w, used as a pre-operative skin disinfectant was examined for its germicidal activity and its chemical stability. The additive activity of iodine and propanol resulted in a wide range of antimicrobial activity against bacteria, including bacterial spores, and fungi, with a rapid onset and sustained duration of action. The solution is easily manufactured and analyzed, its stability is guaranteed for 6 months. Because of its staining property, there is no need of coloured additives to mark the disinfected area. In addition, no skin irritations by the disinfectant were observed so far. Thus, the preparation fulfills the essential requirements for preoperative skin disinfectants and is suitable for the preparation and the compounding in hospital pharmacies.

Bacteria↗

[Nebacetin and taurolin as intraoperative disinfectant solutions in surgery of the locomotor system (author's transl)].

The anti-infective preventive action of intraoperative disinfection with physiological solution containing antibiotics, appears to be firmly established, judging from numerous publications. Since germs are showing a world-wide increasing resistance, the search for antibiotics which continue to be effective must be kept up, but alternative suggestions are equally necessary. Some publications have already been presented indicating that success similar to that previously obtained with antibiotics is possible by using disinfectants in the prophylaxis and treatment of infections. Hence, a comparative study was conducted using the non-absorbable broad-spectrum antibiotic Nebacetin and the disinfectant Taurolin in a 1% solution with a group of patients subjected to a total of 7699 major and minor surgical operations. Prospectively, early infections during the stay of the patient in the hospital, als well as disturbed wound healing, were included. No significant difference was found in the number of infections and the rate of disturbed wound healing. Indirectly, it is possible to conclude with the help of results from literature that the disinfectant Taurolin is suitable as an addition to intra-operative rinsing in the prophylaxis of infections.

Anti-Infective Agents, Local↗

Conjunctival hyperemia and corneal infiltrates with chemically disinfected soft contact lenses.

For three cosmetic soft contact lens wearers who chemically disinfected their lenses, conjunctival hyperemia and anterior stromal infiltrates of the cornea developed. When the conjunctival hyperemia and corneal infiltrates resolved, two of the three patients were challenged with their chemically disinfected soft contact lenses, with reappearance of the conjunctival and corneal reactions. Bacterial cultures of the conjunctiva, lids, lens cases, lens solutions, and eye cosmetics were not helpful. Conjunctival cultures for adenovirus and chlamytdial titers were negative. Giemsa stain of conjunctival scrapings showed a few mononuclear cells, polymorphonuclear leukocytes, and rare eosinophils but no inclusion bodies. Occlusive patch tests and intradermal tests showed positive delayed hypersensitivity reactions to the chemical disinfectants in all three patients. Occlusive patch tests with thimerosal suggested that this preservative was responsible for the reactions. Delayed hypersensitivity to thimerosal may play a role in the development of the conjunctival hyperemia and corneal infiltrates described in these patients.

Adolescent↗

[Hygienic and dermatologic aspects of hand disinfection and prophylactic skin antisepsis].

Hygienic hand disinfection must be carried out after all patient-care activities associated with contamination risks, as well as when moving from contaminated to clean body sites, after contact with environmental surfaces in the immediate vicinity of patients, after glove removal and before aseptic procedures. Preparatory handwashing (for about 10 seconds) to mechanically remove soil and bacterial spores should be performed at least 10 minutes before surgical hand disinfection. This allows time for the normalization of increased skin hydration, a prerequisite for effective hand disinfection. Depending on the manufacturer's instructions, application times of 1.5, 3 or 5 minutes can be observed. The regular use of skin care and skin protection products can help to prevent toxic skin irritation. For skin antisepsis the recommended exposure times are > or =15 seconds before subcutaneous injections, > or =1 minute before puncture of joints and body cavities as well as preoperatively, and > or =10 minutes on skin areas rich in sebaceous glands. For all 3 indications, alcohol-based formulations are the agents of choice.

Anti-Bacterial Agents↗

Current GI endoscope disinfection and QA practices.

High-level disinfection (HLD) of GI endoscopes is readily achieved when published guidelines are observed. Contamination is linked to breakdowns in accepted procedure. However, there is no recognized method of verifying adequacy of endoscope reprocessing in routine practice and no data regarding current quality assurance (QA) practice. Prior reports have demonstrated a wide variation in routine clinical practice of GI endoscopy HLD. The goal of this study was to determine current practice at regional endoscopy centers with regard to endoscope cleaning and HLD, maintenance, and QA practice. An anonymous multiple-choice questionnaire was mailed to 367 SGNA members in Pennsylvania, Delaware, Virginia, Maryland, and District of Columbia and completed by 230 (63%). The majority of responders were hospital-based and 59% of the units performed over 3000 procedures per year. After use the endoscope was hand-carried or transported in a dry container (97%) to a separate cleaning room (85%) for HLD by technicians (40%). Wide variations existed in manual step procedures including use of disposable (50%) brushes and number of times channel brushed: once (21%), twice (35%), or three to five times (37%). Soaking duration in disinfectant (70% gluteraldehyde) was for <10 min (8%), 10-20 min (35%), 20-30 min (38%), 30-40 min (7%), and >40 min (3%). Sixty-seven percent had an active unit infection control (IC) service and 98% had a QA program. Monitoring of cleaning effectiveness was by visual inspection (50%) and culturing endoscopes (17%). Culture was done weekly (1%) and <biannually (6.5%) and performed by swabing the endoscope end (5%) or rinsing the biopsy channel (8%). If culture positive, most would remove the instrument from clinical use and reevaluate the protocol and personnel for technique lapses. Two respondents were aware of a procedure-related infection. Wide practice variations were noted in manual cleaning and in soaking time during automated HLD in this community. Fewer variations were noted in cleaning personnel and training, location and methods of cleaning, and presence of IC services and QA programs. Endoscope culturing was infrequently done and positive cultures were rare. While most units claim to have ongoing QA programs, few use objective criteria to monitor effective disinfection or lapses in technique. Iatrogenic infection is uncommonly recognized following GI endoscope procedures.

Disinfectants↗

Effect of disinfection of custom tray materials on adhesive properties of several impression material systems.

The effects of impression tray disinfection procedures on the bond strength of impression-material adhesives to two types of resin trays were evaluated with a tensile test. Autopolymerizing acrylic resin and a visible light-curing resin were formed into one-half inch cubes. A screw eye was attached to each cube before polymerization. Perforated trays were fabricated with stops to maintain an even one-eighth inch of impression material over the resin block. Hooks on the opposite side permitted attachment of the metal plate to a mechanical testing machine. Before adhesive was applied, one third of the resin specimens were immersed in a 1:213 iodophor solution; one third in a 10% sodium hypochlorite solution, and one third were kept in the "as fabricated" condition. Polysulfide, polyether, and polyvinyl siloxane impression material-adhesive systems were evaluated. The resin-impression material-metal plate couples were attached to a mechanical testing machine and tensile forces were applied at a separation rate of 5 inches per minute. Mean values for adhesive strength ranged from 3.49 kg/cm2 for the autopolymerizing acrylic resin/iodophor/polyether combination to 10.55 kg/cm2 for the autopolymerizing acrylic resin/untreated/polyvinyl siloxane combination. Differences were detected among materials and disinfecting procedure. Clinically, disinfection of resin trays may adversely affect retention of the impression material to the tray.

Acrylic Resins↗

Comparison of automated systems for the cleaning and disinfection of flexible fibreoptic endoscopes.

A comparison of four cleaning and disinfection machines is described. These varied considerably in design and function and although no single machine possessed all the preferred characteristics, cleaning and disinfection, particularly between patients, was substantially improved. Before purchasing a machine it is recommended that the user ensures that it is convenient to operate, effective in removing soil and bacteria, and adaptable to the range of fibrescopes used within the unit. Infections are often caused by Gram-negative bacilli which are particularly difficult to remove manually from moist narrow channels of the fibrescope and perfusion of all channels including the air channel, is, therefore, recommended. Thorough cleaning and disinfection will not only reduce the likelihood of infection but will also reduce channel blockages and the general deterioration of the fibrescope.

Decontamination↗

A laboratory model for testing agents for hygienic hand disinfection: handwashing and chlorhexidine for the removal of klebsiella.

A model for the laboratory assessment of hygienic hand disinfection is described which closely reproduces handwashing in a ward setting. The model uses a clinically relevant test organism and takes into account the natural antibacterial action of the skin. It also provides a means of measuring any residual antibacterial action after hand disinfection. Using an epidemic multiply-resistant strain of Klebsiella aerogenes K21, 0.5% chlorhexidine in iso-propyl alcohol yielded sterile post-disinfection finger washings more often than 4% chlorhexidine digluconate. Both preparations were more effective than soap and water, and with each residual action was demonstrable. The model is applicable to the laboratory evaluation of hygienic hand procedures and for agents of potential use in defined clinical settings.

1-Propanol↗

A test for the assessment of 'hygienic' hand disinfection using rotavirus.

A standardized test procedure is described in which finger tips are inoculated with bovine rotavirus. The level of virus recovered after disinfection of artificially contaminated hands with various disinfectant detergents, alcoholic solutions and alcoholic formulations was determined. The method was found to be easy to perform and reproducible. The most efficient method for removal of virus from fingertips was found to be treatment with alcoholic solutions or products. Soap and water and disinfectant detergents were found to be a much less effective method of removing virus from contaminated hands.

Alcohols↗

Effect of iodine disinfection products on higher plants.

Iodine is used to disinfect potable water on United States spacecraft. Iodinated potable water will likely be used to grow plants in space. Little is known about the effects of iodine disinfection products on plants. Seeds of select higher plants were germinated in water iodinated using the Shuttle Microbial Check Valve, and water to which measured amounts of iodide was added. Percent germination was decreased in seeds of most species germinated in iodinated water. Beans were most affected. Germination rates, determined from germination half-times, were decreased for beans germinated in iodinated water, and water to which iodide was added. Development was retarded and rootlets were conspicuously absent in bean and several other plant species germinated in iodinated water. Iodide alone did not elicit these responses. Clearly iodine disinfection products can affect higher plants. These effects must be carefully considered for plant experimentation and cultivation in space, and in design and testing of closed environmental life support systems.

Brassica↗

Sporicidal activity in liquid chemical products to sterilize or high-level disinfect medical and dental instruments.

BACKGROUND: Various liquid chemical products are commercially available in Mexico under sporicidal label claims. Frequently, information provided on their labels conflicts with published data on active ingredients, use concentrations, or exposure times. OBJECTIVE: To evaluate sporicidal activity in 8 chemical products sold for the sterilization or high-level disinfection of medical and dental instruments. METHODS: Bacillus atrophaeus ATCC 9372 spores were suspended (10 6 spores in 50 mL) in each of 4 glutaraldehyde solutions: a super oxidized solution, a hydrogen peroxide formulation, a quaternary ammonium compound, and an ortho -phthalaldehyde solution. After up to a 10-hour exposure, the solutions were passed through 0.22-mum filters, which were then rinsed with 1% sodium bisulfite, washed, and incubated on tryptic soy agar for 5 days at 37 degrees C. RESULTS: At the use concentrations stipulated on their labels, only 2 of 6 products registered as sterilants showed sporicidal activity when challenged with 6 log 10 : a 2% glutaraldehyde in 10 hours and the hydrogen peroxide solution in 6 hours. Of 2 products registered as high-level disinfectants, only the ortho -phthalaldehyde showed noticeable sporicidal activity after 10-hour exposure. CONCLUSION: The results show that some chemical products, commercially available in Mexico as "Liquid Chemical Sterilants/High-Level Disinfectants" cannot be used reliably to process instruments between patients.

Disinfectants↗

Endoscope disinfection using chlorine dioxide in an automated washer-disinfector.

Although 2% glutaraldehyde is often the first-line agent for endoscopic disinfection, its adverse reactions are common among staff and it is less effective against certain mycobacteria and spore-bearing bacteria. Chlorine dioxide is a possible alternative and an automated washer-disinfector fitted with this agent is currently available. This study was conducted to evaluate the effectiveness of chlorine dioxide in endoscopic disinfection after upper gastrointestinal examination. In vitro microbicidal properties of chlorine dioxide solutions were examined at high (600 ppm) and low (30 ppm) concentrations against various microbes including Pseudomonas aeruginosa, Helicobacter pylori, Mycobacterium avium-intracellulare and Bacillus subtilis in the presence or absence of bovine serum albumin (BSA). Immediately following endoscopic procedures and after application to the automated reprocessor incorporating chlorine dioxide at 30 ppm for 5 min, endoscopic contamination with infectious agents, blood, H. pylori ureA gene DNA and HCV-RNA was assessed by cultivation, sensitive test tape, polymerase chain reaction (PCR) and reverse transcriptase-PCR analysis, respectively. Chlorine dioxide at 30 ppm has equivalent microbicidal activity against most microbes and faster antimicrobial effects on M. avium-intracellulare and B. subtilis compared with 2% glutaraldehyde, but contamination with BSA affected the microbicidal properties of chlorine dioxide. Endoscopic contamination with microbes, blood and bacterial DNA was eliminated after application of the automated reprocessor/chlorine dioxide system. Thus, chlorine dioxide is a potential alternative to glutaraldehyde. The use of automated reprocessors with compatibility to chlorine dioxide, coupled with thorough pre-cleaning, can offer effective, faster and less problematic endoscopic disinfection.

Bacteria↗

Chlorine and ozone disinfection of Encephalitozoon intestinalis spores.

Microsporidia are intracellular eukaryotic parasites which have the potential for zoonotic and environmental, including waterborne, transmission. Encephalitozoon intestinalis is a microsporidian pathogen of humans and animals and has been detected in surface water. It is also on the Contaminant Candidate List of potential emerging waterborne pathogens for the US EPA. We performed disinfection studies using chlorine and ozone on E. intestinalis spores with a cell-culture most-probable-number assay to determine infectivity. Chlorine experiments were performed at 5 degrees C at pH of 6, 7, and 8 with 1mg/L initial chlorine concentrations, while ozone experiments were performed at 5 degrees C and pH 7 with initial ozone doses of 1 and 0.5mg/L, both in buffered water. A derivation of Hom's model for disinfection kinetics under dynamic disinfectant concentrations was used to fit observed data and calculate concentration-time product (C*t) values. Chlorine C*t values varied with pH such that 99% (2-log(10)) C*t ranged from 12.8 at pH 6 to 68.8 at pH 8 (mg min/L). Ozone C*t values were approximately an order of magnitude less at 0.59--0.84 mg min/L, depending on initial concentration.

Animals↗

Antimicrobial activity of environmental surface disinfectants in the absence and presence of bioburden.

Thirty-nine products representing six categories of disinfectants (alcohols, chlorines, dilute glutaraldehydes, iodophors, phenolics, and quaternary ammonium compounds) were first tested in the absence of bioburden, using four test methods with five test organisms. Products that performed best were retested with the same methods and organisms in the presence of both serum and whole blood, using 3- and 10-minute contact times. Only products containing high ethyl alcohol had consistently high antimicrobial activity regardless of the test method, test organism, or contact time used both in the absence and presence of bioburden. Although these specific formulations demonstrated ability to penetrate and inactivate high concentrations of microorganisms within heavy bioburden, optimum disinfection of environmental surfaces is highly formulation dependent. Other products tested showed deficiencies that contraindicate their use as environmental surface disinfectants in clinical dental settings.

Alcohols↗

Removal of chlorine dioxide disinfection by-products by ferrous salts.

Chlorine dioxide when used as an effective disinfectant forms undesirable disinfection by-products, i.e. chlorite and chlorate ions. The aim of this research was to study the removal of these ions by ferrous ions in the presence or absence of oxygen. The efficiency of Fe+2 for ClO2- and ClO3- removal was followed by a determination of their initial and final concentrations, pH and delta Fe+2 consumed/delta ClO2- removed ratios. The optimal weight ratio of delta Fe+2 consumed/delta ClO2- removed for complete ClO2 removal was found to be close to the theoretical calculated value of 3.31. It was proved that ferrous salts can reduce chlorite ions to harmless Cl- ions. This method can be recommended as a part of ClO2 disinfection to ensure safe drinking water, with no harm to water consumers and to the environment.

Chlorates↗

Evaluation of the bactericidal effect of five products for surgical hand disinfection according to prEN 12054 and prEN 12791.

Surgical hand disinfection (with an alcohol-based hand rub) and surgical handwash (with an antiseptic-based liquid soap) are accepted measures to reduce the risk for surgical site infections. The new European Standards allow a comparison of their antimicrobial efficacy. The bactericidal activity of surgical hand rubs [Sterillium and Softaman, (active ingredient=alcohols)] and handwashes [Derman plus (triclosan), Hibiscrub (chlorhexidine) and Betadine (PVP-iodine)] was tested according to the prEN 12054 suspension test using Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus and Enterococcus hirae, and to prEN 12791 for the effect on resident skin flora in comparison with 1-propanol, 60% (v/v). All five products achieved a reduction of test bacteria within 3 min of >10(5)-fold so fulfilling prEN 12054. However, only Hibiscrub, Sterillium and Softa Man met the requirements of prEN 12791, giving a mean reduction of resident micro-organisms (immediate and sustained effect) which was not significantly lower than the reference alcohol (P>0.1; Wilcoxon matched-pairs signed-rank test). Sterillium was significantly more effective than the reference alcohol (immediate and sustained affect). Products for surgical hand disinfection may have equal antimicrobial activity in suspension tests but show large differences under practical conditions. Healthcare workers should not rely on results from suspension tests when deciding on a product for surgical hand disinfection.

1-Propanol↗

Susceptibility of HIV to inactivation by disinfectants and ultraviolet light.

Assays were developed to assess a variety of conditions and presentations of infectious HIV to potential inactivating sources. A range of commercially available disinfectants with active constituents including glutaraldehyde, chlorine, phenolics, alcohol, iodine and quaternary ammonium compounds was tested. In addition, u.v. light was investigated as a potential inactivating source. All products were assessed against cell-free HIV in culture medium and cell-associated HIV suspended in medium or whole human blood. All products completely inactivated cell-free HIV following a 1 min exposure. However, cell-associated HIV was more resilient, requiring exposure of 5 min or more for some disinfectants. The effectiveness of the disinfectants was further compromised in the presence of blood.

Blood↗

Potential health effects of drinking water disinfection by-products using quantitative structure toxicity relationship.

Disinfection by-products (DBPs) are produced as a result of disinfecting water using various treatment methods. Over the years, chlorine has remained the most popular disinfecting agent due to its ability to kill pathogens. However, in 1974, it was discovered that the superchlorination of drinking water resulted in the production of chloroform and other trihalomethanes. Since then hundreds of additional DBPs have been identified, including haloacetic acids and haloacetonitriles with very little or no toxicological data available, thus necessitating the use of additional methods for hazard estimation. Quantitative Structure Toxicity Relationship (QSTR) is one such method and utilizes a computer-based technology to predict the toxicity of a chemical solely from its molecular attributes. The current research was conducted utilizing the TOPKAT/QSTR software package which is comprised of robust, cross-validated QSTR models for assessing mutagenicity, rodent carcinogenicity (female/male; rat/mouse), developmental toxicity, skin sensitization, lowest-observed-adverse-effect level (LOAEL), fathead minnow LC(50), rat oral LD(50) and Daphia magna EC(50). A total of 252 DBPs were analyzed for the likelihood that they would produce tumors and developmental effects using the carcinogenicity and developmental toxicity submodels of TOPKAT. The model predictions were evaluated to identify generalizations between the functional groups (e.g. alcohols, acids, etc.) and specific toxic endpoints. Developmental toxicity was identified as an endpoint common to the majority of aliphatic mono- and dicarboxylic acids, aliphatic halogenated and non-halogenated ketones, and aliphatic haloacetonitriles. In the case of the carcinogenicity submodels, most aliphatic aldehydes were identified as carcinogens only in the female mouse submodel. The majority of the aliphatic and aromatic dicarboxylic acids were identified as carcinogens in the female rat submodel. All other functional groups examined were largely predicted as non-carcinogens in all the cancer submodels (i.e. male/female rats and mice). The QSTR results should aid in the prioritization for evaluation of toxic endpoints in the absence of in vivo bioassays.

Algorithms↗