Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ATMOSPHERIC PRESSURE”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58Linked to original sources

An experimental study of the electrospraying of water in air at atmospheric pressure.

Water solutions with electrical conductivities ranging from that of the deionized water up to 2 S/m have been electrosprayed in air through narrow silica tubes. Results show unambiguously that steady cone jets of water in air without the assistance of glow discharge can be formed for the range of electrical conductivities we have explored. The absence of corona discharge has been proven not only for the good agreement between the experimental results and the scaling laws given in the cone-jet literature but also for the independence of the spray current on the atmosphere (air or CO(2)) in which water was being electrosprayed. Other regimes such as the electric dripping and the assisted glow discharge cone-jet mode that appear in the electrospraying of water in air at room temperature have also been investigated.

Journal Article↗

Quantitative determination of rivastigmine and its major metabolite in human plasma by liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry.

A sensitive, specific, accurate and reproducible LC-MS-MS method was developed and validated for the simultaneous determination of rivastigmine and its major metabolite NAP 226-90 in human plasma according to International Regulatory Requirements. After addition of their respective labelled internal standards, the compounds were extracted from plasma using methyl-tert.-butyl ether at basic pH with a simultaneous derivatization of NAP 226-90 with propionic anhydride, and backextracted into an acidic solution. After re-extraction the compounds were analyzed on a 3-micrometer Purospher Star RP-18 column interfaced with a MDS Sciex API 3000 triple quadrupole mass spectrometer. Positive atmospheric chemical ionization was employed as the ionization source. The analytes and their internal standards were detected by use of multiple reaction monitoring mode. Intra- and inter-day accuracy and precision were found suitable over the range of concentrations between 0.200 and 30.0 ng/ml. The LC-MS-MS method was crossvalidated with a previously developed in-house GC-MS method by the analysis of plasma samples obtained from patients after administration of Exelon((R)) capsules and showed excellent correlation between the methods.

Calibration↗

Characterization of surface roughness in titanium dental implants measured with scanning tunnelling microscopy at atmospheric pressure.

Characterization of the surface topography of implant materials is important for understanding tissue response. We have measured, for the first time, the topography of titanium surfaces used in osseointegrated dental implants. Scanning tunnelling microscopy (STM) which provides 3D real space images was used. In addition to clinical samples, electropolished and anodically oxidized surfaces were also measured. Clinical samples are rather inhomogeneous in character showing grooves and steps with a maximum depth of 0.11 micron. Micropores with an average diameter of about 30 nm are also present. Electropolished samples are rather homogeneous and very smooth, showing steps of 1 to 5 nm in height. The measurements were performed under atmospheric conditions at a resolution in the subnanometer range.

Dental Implantation, Endosseous↗

Identification of tyrosine sulfation in Conus pennaceus conotoxins alpha-PnIA and alpha-PnIB: further investigation of labile sulfo- and phosphopeptides by electrospray, matrix-assisted laser desorption/ionization (MALDI) and atmospheric pressure MALDI mass spectrometry.

Liquid chromatography/electrospray ionization mass spectrometry was used to investigate the peptide composition of the venom of Conus pennaceus, a molluscivorous cone shell from the Red Sea. Based on observed M(r)s, this venom contained all known conotoxins previously isolated and identified from this species. Interestingly, the doubly protonated species of only two of these conotoxins, alpha-PnIA and alpha-PnIB, showed additional related ions at +40 m/z (+80 Da), indicating the presence of either sulfation or phosphorylation in both components. High-performance liquid chromatographic (HPLC) fractions containing these two conotoxins were examined by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry in both positive and negative ion modes, as well as by MALDI high-energy collision-induced dissociation. These experiments established the presence of a single sulfated tyrosine residue within both alpha-PnIA and alpha-PnIB. Hence their post-translationally modified sequences are GCCSLPPCAANNPDY(S)C-NH2 (alpha-PnIA) and GCCSLPPCALSNPDY(S)C-NH2 (alpha-PnIB). This assignment was supported by comparison of their mass spectral behavior with that of known sulfated and phosphorylated peptides. This data clarified further the distinguishing features of the ionization and fragmentation of such modified peptides. Selective disulfide folding of synthetic alpha-PnIB demonstrated that both sulfated and non-sulfated toxins co-elute on reversed-phase HPLC and that alpha-PnIB possesses the same disulfide connectivity as other 'classical' alpha-conotoxins reported previously.

Amino Acid Sequence↗

Confirmation of gentian violet and its metabolite leucogentian violet in catfish muscle using liquid chromatography combined with atmospheric pressure ionization mass spectrometry.

Gentian violet (GV) is a triphenylmethane dye antiseptic with potential for illegal use in livestock production, especially aquaculture where the related malachite green has been widely used. This potential misuse has regulatory importance because of the observed rodent carcinogenicity of GV. This report describes the use of online LC-APCI/MS for confirmation of incurred GV residues, and those of its principal metabolite, LGV, in catfish muscle following treatment of live catfish with GV under putative use conditions. LC with APCI/MS detection provided sensitive analysis of GV and LGV with estimated detection limits of < 1 pg observed for both compounds. Fragmentation of GV and LGV via in-source CID was effected by varying the sampling cone-skimmer voltage. Ion intensity data were collected using a rapid cone voltage switching procedure that permits selected ion acquisition under optimal conditions for the parent molecule and several selected fragment ions. For GV, four ions including the ionized molecule were used and for LGV, six ions including the protonated molecule were used. The levels of GV and LGV in muscle from fish dosed with 10 micrograms/l in aquarium water were determined by LC/VIS to be 0.5 and 44 ppb, respectively. Analysis of these samples yielded ion intensity ratios that agreed precisely between injections (< 5%) and accurately with those generated by a comparable amount of authentic GV and LGV (< 10% deviation). These results show the utility of on-line LC-APCI/MS to do both sensitive confirmatory analyses of incurred drug residues for use in monitoring the food supply.

Animals↗

Atmospheric pressure ion mobility spectrometry of protonated and sodiated peptides.

A number of peptides were studied with electrospray ionization--ion mobility spectrometry/mass spectrometry (ESI-IMS/MS). The ion mobility data were used to calculate the average collision cross sections of the different detected peptide ions in the nitrogen drift gas. By comparing the cross sections of related ions, structural information about the most probable location of the charge and the gas-phase ion conformations was deduced. For bradykinin and kemptide, a significant mobility difference between protonated and sodiated species (where sodium replaced a proton in singly and doubly charged peptides) was demonstrated. Surprisingly, the doubly charged sodiated peptides had a smaller collision cross section than the doubly charged protonated ones leading to the conclusion that the gas-phase conformations of these ions are different with respect to intramolecular interactions.

Angiotensin II↗

Phosphane Sulfide/Octacarbonyldicobalt-Catalyzed Pauson - Khand Reaction Under an Atmospheric Pressure of Carbon Monoxide.

Convenient access to cyclopentenones is provided by catalytic intra- and intermolecular Pauson - Khand reactions in the presence of octacarbonyldicobalt and tributylphosphane sulfide (see scheme). In contrast to other reactions of this type, they proceed under mild conditions (70 degrees C, 1 atm CO), and commercially available [Co(2)(CO)(8)] can be used without further purification.

Journal Article↗

Mass spectrometric characterization of efaproxiral (RSR13) and its implementation into doping controls using liquid chromatography-atmospheric pressure ionization-tandem mass spectrometry.

Efaproxiral (2-[4-[[(3,5-dimethylanilino)carbonyl]methyl]phenoxyl]-2-methylpropionic acid, formerly referred to as RSR13) is prohibited in sports according to the World Anti-Doping Agency (WADA). The drug as well as structurally related compounds and a stable isotope-labeled derivative have been synthesized to elucidate the fragmentation pathway of efaproxiral, using electrospray ionization (ESI) and tandem mass spectrometry by employing a novel linear ion trap--orbitrap hybrid mass spectrometer--in positive and negative ionization modes. The elimination of 2-methyl acrylic acid (-86 u) has been identified as a major fragmentation process in both charge states. Negative ionization and collision-induced dissociation (CID) caused an additional release of carbon dioxide (-44 u), and positive ionization the loss of formic acid (-46 u). Efaproxiral was incorporated into an existing screening procedure for doping controls using solid-phase extraction (SPE) followed by liquid chromatography-tandem mass spectrometry, enabling a limit of detection of 2.5 ng/ml and interday precisions ranging from 7.9 to 13.0%.

Aniline Compounds↗

Quantitative analyses of indoloquinazoline alkaloids in Fructus Evodiae by high-performance liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry.

Fructus Evodiae (Wuzhuyu), the fruits of Evodia rutaecarpa and related varieties, is widely used in traditional Chinese medicine. The bioactive constituents include the indoloquinazoline alkaloids rutaecarpine, evodiamine and dehydroevodiamine. A new assay based on high-performance liquid chromatography/atmospheric pressure chemical ionization tandem mass spectrometry (HPLC/UV/APCI-MS/MS) was developed for the measurement of the indoloquinazoline alkaloids in commercial Fructus Evodiae products. Initially, the MS/MS fragmentation pathways of indoloquinazoline alkaloids were investigated to identify fragment ions that might be useful for the sensitive and selective detection of trace indoloquinazoline alkaloids during LC/MS/MS. Then, quantitative MS analysis of five indoloquinazoline alkaloids in 12 commercial Fructus Evodiae products from different geographical sources was performed. Analyte recovery was in the range of 97.5-105.3% for all with relative standard deviations (RSDs) below 6%, the intra-assay and inter-assay RSDs were less than 7%, and good linear relationships were shown with correlation coefficients for the analytes exceeding 0.999. Therefore, this LC/MS/MS assay facilitated the rapid quantitative analysis of rutaecarpine, evodiamine, evodiamide, 14-formyldihydrorutaecarpine and dehydroevodiamine in 12 commercial Fructus Evodiae products with excellent recovery, repeatability, accuracy and sensitivity. This method is simple and specific and can be used for identification and quality control of this traditional Chinese remedy.

Chromatography, High Pressure Liquid↗

Quantitative determination of perfluorooctanoic acid ammonium salt in human serum by high-performance liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry.

A sensitive, specific, accurate and reproducible analytical method was developed and validated to quantify perfluorooctanoic acid (PFOA) in human serum. After initial extraction with an ion-paring reagent, the procedure for quantifying PFOA is based on high-performance liquid chromatography (HPLC) interfaced to negative ion tandem mass spectrometry, operating in selected ion monitoring mode. The retention times of PFOA and its internal standard (D,L-malic acid) were 5.85 and 1.70 min, respectively. The assay was linear over the range 0-500 ng/mL, with a lower limit of quantification (LOQ) of 25 ng/mL, and with a coefficient of variation (CV) of 7.3%. The lower limit of detection (LOD) was assessed as 10 ng/mL. The overall precision and accuracy were assessed on three different days. The within- and between-day precision was < or =9.7 and 6.8%, respectively, and the accuracy was in the range 96-114%. The mean extracted recovery assessed at three different concentrations (100, 250, and 500 ng/mL) was always more than 85%. With this method no derivatization procedure was needed, thus avoiding possible thermal and chemical decomposition reactions of PFOA. The assay was applied to quantify perfluorooctanoic acid in serum from employees exposed to fluorochemicals commonly used in industrial applications for polymer production. The quantitative results for PFOA blood levels were found to vary between 100 and 982 ng/mL.

Caprylates↗